GZGianluigi Zampa

Gianluigi Zampa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gianluigi Zampa has a total of 552 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The General Antiparticle Spectrometer (GAPS) Antarctic balloon payload

    by Kazutaka Aoyama, Tsuguo Aramaki, Padrick Beggs, Mirko Boezio, Steven E. Boggs, Valter Bonvicini, Gabriel Bridges, Donatella Campana, Scott Candey, William W. Craig, et al.

  • Open Access

    CubeSats Reach the Millisecond X-Ray Domain: Crab Pulsar Timing with SpIRIT/HERMES

    by Wladimiro Leone, R. Mearns, T. di Salvo, L. Burderi, M. Thomas, M. Trenti, F. Fiore, E. J. Marchesini, R. Campana, G. Baroni, et al.

    The High Energy Rapid Modular Ensemble of Satellites (HERMES) instrument is a compact X-/gamma-ray spectrometer operating on board the 6U (11 kg) Space Industry–Responsive–Intelligent–Thermal (SpIRIT) CubeSat. The payload is particularly well suited for the observation of cosmic transients such as gamma-ray bursts (GRBs) and bright pulsars thanks to its unique broadband sensitivity from a few keV to a few MeV and temporal resolution down to half a microsecond. We report the detection of the ∼33 ms double-peaked pulse profile of the Crab Pulsar, obtained by considering the canonical Crab ephemerides as provided by the Jodrell Bank catalog. We collected approximately 5.7 × 10 4 photons from 730 s of observations in the 3 keV–2 MeV energy band during a single operation, achieving a 5 σ pulse-profile significance in the 3–11.5 keV energy band with millisecond-scale binning. These results demonstrate that SpIRIT/HERMES can achieve millisecond timing accuracy at high energies and, thanks to its wide field of view and broad energy coverage, has the potential to contribute to GRB monitoring in the near future. Such capabilities were previously the domain of flagship observatories, underscoring the performance of the HERMES instrument even with its compact form factor.


  • X-Ray and Particle Detection With the Si(Li) Tracker Module of the GAPS Experiment

    by Massimo Manghisoni, Luca Ghislotti, Paolo Lazzaroni, Valerio Re, Elisa Riceputi, Lodovico Ratti, Lorenzo Fabris, Mirko Boezio, Gianluigi Zampa, Mengjiao Xiao

    This work describes the architecture and the experimental results from the characterization of the lithium-drifted silicon (Si(Li)) detector module, which constitutes the building block of the tracker in the General Antiparticle Spectrometer (GAPS) experiment to search for dark matter. The instrument is designed for the identification of low-energy cosmic antinuclei (antiprotons, antideuterons and antihelium) to be performed during an Antarctic long-duration balloon flight scheduled for late 2025. The GAPS Si(Li) tracker, that is the core of the instrument, is the assembly of 252 modules, each comprised of four Si(Li) detectors and a full custom integrated circuit designed for detector readout and produced in a commercial 180 nm planar CMOS technology. A general overview of the detector module architecture and its components is provided, together with a description of the test setup and the experimental results obtained from the characterization of the low-noise analog readout channel. In order to verify the effective operation of the entire module, results concerning the detection of X-rays from a 241Am source and cosmic muons are also provided.

  • Open Access

    Functional tests of the detector assembly demonstration model of the eXTP wide field monitor: system description and results

    by M. Antonelli, G. Zampa, V. Bonvicini, D. Cirrincione, G. Orzan, A. Rachevski, I. Rashevskaya, N. Zampa, G. Aitink-Kroes, R. de la Rie, et al.

    The Wide Field Monitor is one of the 4 state-of-the-art instruments onboard the enhanced X-ray Timing and Polarimetry mission, which will search for and observe neutron stars, magnetars and black holes to study matter under extreme conditions of density, gravity and magnetism. The wide-field cameras of the Wide Field Monitor are based on large-area silicon drift detectors. Such position-sensitive spectroscopic detectors, together with their front-end electronics, must pass a series of functional tests before proceeding with the mass production of the detector assemblies. This paper describes the test system developed to carry out such measurements, as well as reporting the results of the functional tests together with a preliminary characterisation of the performance of the detector assemblies.

  • Open Access

    Development of a high-resolution, high-dynamic-range charge detector for ion beam monitoring

    by O. Adriani, E. Berti, P. Betti, J. Casaus, R. D'Alessandro, S. Detti, C. Diaz, J. Marin, G. Martinez, N. Mori, et al.

    We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a custom readout electronics, underwent extensive testing during HERD and AMS beam tests at CERN SPS facilities. Initial testing showcased the detector's exceptional performance, emphasizing both high resolution and a dynamic range capable of measuring nuclei with atomic numbers ranging from 1 to 80. The prototype's compatibility with fast, quasi real-time data analysis qualifies it as an ideal candidate for online applications. This article presents the results from the testing phase of the prototype, highlighting its capabilities and performance. Ongoing detector development, potential applications, and future developments aimed at enhancing the detector's functionality and versatility are also discussed.


  • The STROBE-X wide field monitor instrument

    by Ronald A. Remillard, Margarita Hernanz, Jean In’t Zand, Paul S. Ray, Valter Bonvicini, Søren Brandt, Terri Brandt, Alex Carmona, Yuri Evangelista, Daniel Alvarez Franco, et al.

    The wide-field monitor (WFM) is one of the three instruments on the “Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays” (STROBE-X) mission, which was proposed in response to the National Aeronautics and Space Administration’s 2023 call for a probe-class mission. The WFM is a coded-mask camera system that would be the most scientifically capable wide-angle monitor ever flown. The WFM will anchor X-ray time domain astronomy, at the all-sky level, for the 2030s. The field of view covers one-third of the sky, to 50% mask coding, and the energy sensitivity is 2 to 50 keV. The WFM will identify new X-ray transients for rapid observations with the two pointed instruments of STROBE-X. In addition, the WFM will capture spectral/timing changes in known sources with data of unprecedented quality. WFM data will uniquely advance scientific knowledge for diverse classes in high-energy astrophysics, including X-ray bursts that coincide with gravitational wave detections, gamma-ray bursts (GRBs) and their transition from prompt emission to afterglow, subluminous GRBs that may signal shock breakout in supernovae, state transitions in accreting compact objects and their jets, bright flares in fast X-ray transients, accretion onset in transitional pulsars, and coronal flares from many types of active stars.


  • Spectroscopic Time-Resolving Observatory for Broadband Energy X-ray high-energy modular array

    by Anthony L. Hutcheson, Marco Feroci, Andrea Argan, Matias Antonelli, Marco Barbera, Jorg Bayer, Pierluigi Bellutti, Giuseppe Bertuccio, Valter Bonvicini, Franck Cadoux, et al.

    The high-energy modular array (HEMA) is one of three instruments that compose the Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) mission concept. The HEMA is a large-area, high-throughput non-imaging pointed instrument based on the large area detector (LAD) developed as part of the Large Observatory For X-ray Timing (LOFT) mission concept. It is designed for spectral timing measurements of a broad range of sources and provides a transformative increase in sensitivity to X-rays in the energy range of 2 to 30 keV compared with previous instruments, with an effective area of 3.4 m2 at 8.5 keV and an energy resolution of better than 300 at 6 keV in its nominal field of regard.


  • Open Access

    Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays: mission overview

    by Paul S. Ray, Peter W. A. Roming, Andrea Argan, Zaven Arzoumanian, David R. Ballantyne, Slavko Bogdanov, Walter Bonvicini, Terri J. Brandt, Michal Bursa, Edward M. Cackett, et al.

    We give an overview of the science objectives and mission design of the “Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays” observatory, which has been proposed as a NASA probe-class (∼$1.5B) mission in response to the Astro2020 recommendation for an X-ray probe.


  • Front-end application-specific integrated circuits for the Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays High Energy Modular Array and Wide Field Monitor detectors: concept and design

    by Gianluigi De Geronimo, Paul S. Ray, Eric A. Wulf, Colleen A. Wilson-Hodge, Eric Burns, Yuri Evangelista, Anthony Hutcheson, Thomas J. Maccarone, Gianluigi Zampa

    We present the NSX front-end application-specific integrated circuits (ASIC), which has been developed to read charge signals from the High Energy Modular Array and Wide Field Monitor X-ray detectors for the Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays mission. The ASIC reads out signals from up to 64 anodes of linear silicon drift detectors (SDDs). When unloaded, the ASIC channel has a charge resolution, expressed in equivalent noise charge (ENC) of ∼2.8 e−. Once connected to the SDD anode, we anticipate, for the 80-keV energy range, an ENC of ∼10.7 e− at a leakage current of 2 pA, which corresponds to a full width half maximum of ∼145 eV at 6 keV once the Fano-limited statistics from charge generation in Si is included. The acquisition is event-triggered, and for events exceeding the threshold, the ASIC measures the peak amplitude and stores it in an analog memory for subsequent readout. The ASIC can also force the measurement of the sub-threshold channels neighboring the triggered channel, including the ones that belong to neighbor chips using bi-directional differential inter-chip communication. Alternatively, the ASIC can measure the amplitudes of all channels at the time of the first detected peak. Additional features include a high-resolution option, a channel power down and skip function, a low-noise pulse generator, a temperature sensor, and the monitoring of the channel analog output and trimmed threshold. The power consumption of the individual channel is ∼590 μW, and when including all shared circuits, it averages to ∼670 μW/channel.


  • Open Access

    Double Photodiode Readout System for the Calorimeter of the HERD Experiment: Challenges and New Horizons in Technology for the Direct Detection of High-Energy Cosmic Rays

    by Pietro Betti, Oscar Adriani, Matias Antonelli, Yonglin Bai, Xiaohong Bai, Tianwei Bao, Eugenio Berti, Lorenzo Bonechi, Massimo Bongi, Valter Bonvicini, et al.

    The HERD experiment is a future experiment for the direct detection of high-energy cosmic rays and is to be installed on the Chinese space station in 2027. The main objectives of HERD are the first direct measurement of the knee of the cosmic ray spectrum, the extension of electron+positron flux measurement up to tens of TeV, gamma ray astronomy, and the search for indirect signals of dark matter. The main component of the HERD detector is an innovative calorimeter composed of about 7500 LYSO scintillating crystals assembled in a spherical shape. Two independent readout systems of the LYSO scintillation light will be installed on each crystal: the wavelength-shifting fibers system developed by IHEP and the double photodiode readout system developed by INFN and CIEMAT. In order to measure protons in the cosmic ray knee region, we must be able to measure energy release of about 250 TeV in a single crystal. In addition, in order to calibrate the system, we need to measure typical releases of minimum ionizing particles that are about 30 MeV. Thus, the readout systems should have a dynamic range of about 107. In this article, we analyze the development and the performance of the double photodiode readout system. In particular, we show the performance of a prototype readout by the double photodiode system for electromagnetic showers as measured during a beam test carried out at the CERN SPS in October 2021 with high-energy electron beams.