Nicola Zampa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nicola Zampa has a total of 397 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Vacchi
Università degli Studi di Udine
15 shared publications - Gianluigi Zampa
26 INFN Trieste, Padriciano, 99, 34149 Trieste, Italy
14 shared publications - Oscar Adriani
INFN, Sezione di Firenze, via Sansone 1, Sesto Fiorentino, 50019 Italy
9 shared publications - Paolo Papini
INFN, Sezione di Firenze, via Sansone 1, Sesto Fiorentino, 50019 Italy
9 shared publications - Valter Bonvicini
INFN, Sezione di Trieste, I-34149 Trieste, Italy
9 shared publications - Elena Vannuccini
INFN, Sezione di Firenze, via Sansone 1, Sesto Fiorentino, 50019 Italy
8 shared publications
Latest Publications
- Open Access
- 10 August 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1093
Dead-time and pileup correction system for the Advanced X-ray Pixel Detector
- 10 August 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1093
Open AccessDead-time and pileup correction system for the Advanced X-ray Pixel Detector
- Open Access
- 1 April 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (04) , C04010
Functional tests of the detector assembly demonstration model of the eXTP wide field monitor: system description and results
The Wide Field Monitor is one of the 4 state-of-the-art instruments onboard the enhanced X-ray Timing and Polarimetry mission, which will search for and observe neutron stars, magnetars and black holes to study matter under extreme conditions of density, gravity and magnetism. The wide-field cameras of the Wide Field Monitor are based on large-area silicon drift detectors. Such position-sensitive spectroscopic detectors, together with their front-end electronics, must pass a series of functional tests before proceeding with the mass production of the detector assemblies. This paper describes the test system developed to carry out such measurements, as well as reporting the results of the functional tests together with a preliminary characterisation of the performance of the detector assemblies.
- 1 April 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (04) , C04010
Open AccessFunctional tests of the detector assembly demonstration model of the eXTP wide field monitor: system description and results
The Wide Field Monitor is one of the 4 state-of-the-art instruments onboard the enhanced X-ray Timing and Polarimetry mission, which will search for and observe neutron stars, magnetars and black holes to study matter under extreme conditions of density, gravity and magnetism. The wide-field cameras of the Wide Field Monitor are based on large-area silicon drift detectors. Such position-sensitive spectroscopic detectors, together with their front-end electronics, must pass a series of functional tests before proceeding with the mass production of the detector assemblies. This paper describes the test system developed to carry out such measurements, as well as reporting the results of the functional tests together with a preliminary characterisation of the performance of the detector assemblies.
- Open Access
- 1 January 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (01) , P01019
Development of a high-resolution, high-dynamic-range charge detector for ion beam monitoring
We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a custom readout electronics, underwent extensive testing during HERD and AMS beam tests at CERN SPS facilities. Initial testing showcased the detector's exceptional performance, emphasizing both high resolution and a dynamic range capable of measuring nuclei with atomic numbers ranging from 1 to 80. The prototype's compatibility with fast, quasi real-time data analysis qualifies it as an ideal candidate for online applications. This article presents the results from the testing phase of the prototype, highlighting its capabilities and performance. Ongoing detector development, potential applications, and future developments aimed at enhancing the detector's functionality and versatility are also discussed.
- 1 January 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (01) , P01019
Open AccessDevelopment of a high-resolution, high-dynamic-range charge detector for ion beam monitoring
We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a custom readout electronics, underwent extensive testing during HERD and AMS beam tests at CERN SPS facilities. Initial testing showcased the detector's exceptional performance, emphasizing both high resolution and a dynamic range capable of measuring nuclei with atomic numbers ranging from 1 to 80. The prototype's compatibility with fast, quasi real-time data analysis qualifies it as an ideal candidate for online applications. This article presents the results from the testing phase of the prototype, highlighting its capabilities and performance. Ongoing detector development, potential applications, and future developments aimed at enhancing the detector's functionality and versatility are also discussed.
- Open Access
- 22 January 2024
- Published by MDPI AG in Instruments
- Vol. 8 (1) , 5
Double Photodiode Readout System for the Calorimeter of the HERD Experiment: Challenges and New Horizons in Technology for the Direct Detection of High-Energy Cosmic Rays
The HERD experiment is a future experiment for the direct detection of high-energy cosmic rays and is to be installed on the Chinese space station in 2027. The main objectives of HERD are the first direct measurement of the knee of the cosmic ray spectrum, the extension of electron+positron flux measurement up to tens of TeV, gamma ray astronomy, and the search for indirect signals of dark matter. The main component of the HERD detector is an innovative calorimeter composed of about 7500 LYSO scintillating crystals assembled in a spherical shape. Two independent readout systems of the LYSO scintillation light will be installed on each crystal: the wavelength-shifting fibers system developed by IHEP and the double photodiode readout system developed by INFN and CIEMAT. In order to measure protons in the cosmic ray knee region, we must be able to measure energy release of about 250 TeV in a single crystal. In addition, in order to calibrate the system, we need to measure typical releases of minimum ionizing particles that are about 30 MeV. Thus, the readout systems should have a dynamic range of about . In this article, we analyze the development and the performance of the double photodiode readout system. In particular, we show the performance of a prototype readout by the double photodiode system for electromagnetic showers as measured during a beam test carried out at the CERN SPS in October 2021 with high-energy electron beams.- 22 January 2024
- Published by MDPI AG in Instruments
- Vol. 8 (1) , 5
Open AccessDouble Photodiode Readout System for the Calorimeter of the HERD Experiment: Challenges and New Horizons in Technology for the Direct Detection of High-Energy Cosmic Rays
The HERD experiment is a future experiment for the direct detection of high-energy cosmic rays and is to be installed on the Chinese space station in 2027. The main objectives of HERD are the first direct measurement of the knee of the cosmic ray spectrum, the extension of electron+positron flux measurement up to tens of TeV, gamma ray astronomy, and the search for indirect signals of dark matter. The main component of the HERD detector is an innovative calorimeter composed of about 7500 LYSO scintillating crystals assembled in a spherical shape. Two independent readout systems of the LYSO scintillation light will be installed on each crystal: the wavelength-shifting fibers system developed by IHEP and the double photodiode readout system developed by INFN and CIEMAT. In order to measure protons in the cosmic ray knee region, we must be able to measure energy release of about 250 TeV in a single crystal. In addition, in order to calibrate the system, we need to measure typical releases of minimum ionizing particles that are about 30 MeV. Thus, the readout systems should have a dynamic range of about . In this article, we analyze the development and the performance of the double photodiode readout system. In particular, we show the performance of a prototype readout by the double photodiode system for electromagnetic showers as measured during a beam test carried out at the CERN SPS in October 2021 with high-energy electron beams. - 27 October 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1058
New detailed characterization of the residual luminescence emitted by the GAGG:Ce scintillator crystals for the HERMES Pathfinder mission
- 27 October 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1058
New detailed characterization of the residual luminescence emitted by the GAGG:Ce scintillator crystals for the HERMES Pathfinder mission
- Open Access
- 2 September 2022
- Published by MDPI AG in Instruments
- Vol. 6 (3) , 33
Photodiode Read-Out System for the Calorimeter of the Herd Experiment
HERD is a future experiment for the direct detection of high energy cosmic rays. The instrument is based on a calorimeter optimized not only for a good energy resolution but also for a large acceptance. Each crystal composing the calorimeter is equipped with two read-out systems: one based on wavelength-shifting fibers and the other based on two photodiodes with different active areas assembled in a monolithic package. In this paper, we describe the photodiode read-out system, focusing on experimental requirements, design and estimated performances. Finally, we show how these features lead to the flight model project of the photodiode read-out system.
- 2 September 2022
- Published by MDPI AG in Instruments
- Vol. 6 (3) , 33
Open AccessPhotodiode Read-Out System for the Calorimeter of the Herd Experiment
HERD is a future experiment for the direct detection of high energy cosmic rays. The instrument is based on a calorimeter optimized not only for a good energy resolution but also for a large acceptance. Each crystal composing the calorimeter is equipped with two read-out systems: one based on wavelength-shifting fibers and the other based on two photodiodes with different active areas assembled in a monolithic package. In this paper, we describe the photodiode read-out system, focusing on experimental requirements, design and estimated performances. Finally, we show how these features lead to the flight model project of the photodiode read-out system.