HCHonggang Chang

Honggang Chang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Honggang Chang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Chongrong Wen

    Natural Gas Research Institute of Southwest Oil & Gas Field Company, PetroChina, Chengdu, Sichuan 610213, China

    1 shared publication
  • Gang Xiong

    Research Institute of Natural Gas Technology, PetroChina Southwest Oil & Gasfield Company, Chengdu 610213, China

    1 shared publication
  • Jinjin Li

    Research Institute of Natural Gas Technology, PetroChina Southwest Oil&Gasfield Company, Chengdu, China

    1 shared publication
  • Jinlong He

    Natural Gas Research Institute of Southwest Oil & Gas Field Company, PetroChina, Chengdu, Sichuan 610213, China

    1 shared publication
  • Jinlong He

    Research Institute of Natural Gas Technology, PetroChina Southwest Oil & Gasfield Company, Chengdu 610213, China

    1 shared publication
  • Ke Liu

    Research Institute of Natural Gas Technology, PetroChina Southwest Oil & Gasfield Company, Chengdu 610213, China

    1 shared publication

Latest Publications

  • Open Access

    Modeling CO2, H2S, COS, and CH3SH Simultaneous Removal Using Aqueous Sulfolane–MDEA Solution

    by Ke Liu, Honggang Chang, Gang Xiong, Jinlong He, Qisong Liu, Jinjin Li

    In this study, a rate-based absorption model coupled with an improved thermodynamic model was developed to characterize the removal of acid components (CO2 and H2S) and organic sulfur (COS and CH3SH) from natural gas with an aqueous sulfolane–MDEA solution. First, the accuracy of the thermodynamic model was validated by comparing the calculated partial pressure of CO2, H2S, and CH3SH with those of the experimental data reported in the literature. Then, the industrial test data were employed to validate the absorption model and the simulation results agreed well with the experimental data. The average relative errors of the removal rates of CO2, COS, and CH3SH are 3.3%, 3.0%, 4.1%, respectively. Based on the validated coupled model, the total mass transfer coefficient and mass transfer resistance of each solute component at different column positions were analyzed. The effects of the gas–liquid ratio, overflow weir height, and absorption pressure on the absorption performance of each component were studied, and the influence of the acid component concentration in the feed gas on the removal efficiency of methyl mercaptan (CH3SH) was also discussed. It is found that the improved absorption model can better characterize the absorption performance and be conducive to the optimal design of the absorber column.


  • Open Access

    Development and industrial application of catalyzer for low-temperature hydrogenation hydrolysis of Claus tail gas

    by Honggang Chang, Ronghai Zhu, Zongshe Liu, Jinlong He, Chongrong Wen, Sujuan Zhang, Yang Li