Mahdi Shariati
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mahdi Shariati has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Nor Hafizah Ramli Sulong
Group of Sustainable Engineered Construction Materials, School of Civil & Environmental Engineering, Faculty of Engineering, Queensland University of Technology, 2 George St., Brisbane, QLD 4000, Australia
2 shared publications Shervin Maleki
Department of Civil Engineering, Sharif University of Technology, Tehran, Iran
2 shared publicationsFarzad Tahmasbi
Department of Civil Engineering, Sharif University of Technology, Tehran, Iran
1 shared publicationKoosha Khorramian
Department of Civil Engineering, Sharif University of Technology, Tehran, Iran
1 shared publicationM M Tahir
UTM Construction Research Centre, Faculty of Civil Engineering, Institute for Smart Infrastructure and Innovative Construction, UTM, 81310, Johor Bahru, Johor, Malaysia
1 shared publication
Latest Publications
- Open Access
- 1 August 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (8) , e0156989
Shear Capacity of C-Shaped and L-Shaped Angle Shear Connectors
This paper investigates the behaviour of C-shaped and L-shaped angle shear connectors embedded in solid concrete slabs. An effective finite element model is proposed to simulate the push out tests of these shear connectors that encompass nonlinear material behaviour, large displacement and damage plasticity. The finite element models are validated against test results. Parametric studies using this nonlinear model are performed to investigate the variations in concrete strength and connector dimensions. The finite element analyses also confirm the test results that increasing the length of shear connector increases their shear strength proportionately. It is observed that the maximum stress in L-shaped angle connectors takes place in the weld attachment to the beam, whereas in the C-shaped angle connectors, it is in the attached leg. The location of maximum concrete compressive damage is rendered in each case. Finally, a new equation for prediction of the shear capacity of C-shaped angle connectors is proposed.
- 1 August 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (8) , e0156989
Open AccessShear Capacity of C-Shaped and L-Shaped Angle Shear Connectors
This paper investigates the behaviour of C-shaped and L-shaped angle shear connectors embedded in solid concrete slabs. An effective finite element model is proposed to simulate the push out tests of these shear connectors that encompass nonlinear material behaviour, large displacement and damage plasticity. The finite element models are validated against test results. Parametric studies using this nonlinear model are performed to investigate the variations in concrete strength and connector dimensions. The finite element analyses also confirm the test results that increasing the length of shear connector increases their shear strength proportionately. It is observed that the maximum stress in L-shaped angle connectors takes place in the weld attachment to the beam, whereas in the C-shaped angle connectors, it is in the attached leg. The location of maximum concrete compressive damage is rendered in each case. Finally, a new equation for prediction of the shear capacity of C-shaped angle connectors is proposed.
- Open Access
- 7 December 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (12) , e0144288
Behavior of Tilted Angle Shear Connectors
According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle shear connectors under monotonic loading using experimental push out tests. Eight push-out specimens are tested to investigate the effects of different angle parameters on the ultimate load capacity of connectors. Two different tilted angles of 112.5 and 135 degrees between the angle leg and steel beam are considered. In addition, angle sizes and lengths are varied. Two different failure modes were observed consisting of concrete crushing-splitting and connector fracture. By increasing the size of connector, the maximum load increased for most cases. In general, the 135 degrees tilted angle shear connectors have a higher strength and stiffness than the 112.5 degrees type.
- 7 December 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (12) , e0144288
Open AccessBehavior of Tilted Angle Shear Connectors
According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle shear connectors under monotonic loading using experimental push out tests. Eight push-out specimens are tested to investigate the effects of different angle parameters on the ultimate load capacity of connectors. Two different tilted angles of 112.5 and 135 degrees between the angle leg and steel beam are considered. In addition, angle sizes and lengths are varied. Two different failure modes were observed consisting of concrete crushing-splitting and connector fracture. By increasing the size of connector, the maximum load increased for most cases. In general, the 135 degrees tilted angle shear connectors have a higher strength and stiffness than the 112.5 degrees type.