VMVoichita Maxim

Voichita Maxim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Voichita Maxim has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    CoReSi: a GPU-based software for Compton camera reconstruction and simulation in collimator-free SPECT

    by Vincent Lequertier, Étienne Testa, Voichiţa Maxim

    Objective. Compton cameras (CCs) are imaging devices that may improve observation of sources of γ photons. The images are obtained by solving a difficult inverse problem. We present CoReSi, a Compton reconstruction and simulation software implemented in Python and powered by PyTorch to leverage multi-threading and to easily interface with image processing and deep learning algorithms. The code is mainly dedicated to medical imaging and near-field experiments where images are reconstructed in 3D. Approach. The code was developed over several years in C++, with the initial version being proprietary. We have since redesigned and translated it into Python, adding new features to improve its adaptability and performances. This paper reviews the literature on CC mathematical models, explains the implementation strategies we have adopted and presents the features of CoReSi. Main results. The code includes state-of-the-art mathematical models from the literature, from the simplest, which allow limited knowledge of the sources, to more sophisticated ones with a finer description of the physics involved. It offers flexibility in defining the geometry of the CC and the detector materials. Several identical cameras can be considered at arbitrary positions in space. The main functions of the code are dedicated to the computation of the system matrix, leading to the forward and backward projector operators. These are the cornerstones of any image reconstruction algorithm. A simplified Monte Carlo data simulation function is provided to facilitate code development and fast prototyping. Significance. As far as we know, there is no open source code for CC reconstruction, except for MEGAlib, which is mainly dedicated to astronomy applications. This code aims to facilitate research as more and more teams from different communities such as applied mathematics, electrical engineering, physics, medical physics get involved in CC studies. Implementation with PyTorch will also facilitate interfacing with deep learning algorithms.


  • Open Access

    Bimodal PET/MRI generative reconstruction based on VAE architectures

    by V Gautier, A Bousse, F Sureau, C Comtat, V Maxim, B Sixou

    Objective. In this study, we explore positron emission tomography (PET)/magnetic resonance imaging (MRI) joint reconstruction within a deep learning framework, introducing a novel synergistic method. Approach. We propose a new approach based on a variational autoencoder (VAE) constraint combined with the alternating direction method of multipliers (ADMM) optimization technique. We explore three VAE architectures, joint VAE, product of experts-VAE and multimodal JS divergence (MMJSD), to determine the optimal latent representation for the two modalities. We then trained and evaluated the architectures on a brain PET/MRI dataset. Main results. We showed that our approach takes advantage of each modality sharing information to each other, which results in improved peak signal-to-noise ratio and structural similarity as compared with traditional reconstruction, particularly for short acquisition times. We find that the one particular architecture, MMJSD, is the most effective for our methodology. Significance. The proposed method outperforms conventional approaches especially in noisy and undersampled conditions by making use of the two modalities together to compensate for the missing information.


  • Iterative tomographic reconstruction with TV prior for low-dose CBCT dental imaging

    by Louise Friot--Giroux, Françoise Peyrin, Voichita Maxim

    Objective. Cone-beam computed tomography is becoming more and more popular in applications such as 3D dental imaging. Iterative methods compared to the standard Feldkamp algorithm have shown improvements in image quality of reconstruction of low-dose acquired data despite their long computing time. An interesting aspect of iterative methods is their ability to include prior information such as sparsity-constraint. While a large panel of optimization algorithms along with their adaptation to tomographic problems are available, they are mainly studied on 2D parallel or fan-beam data. The issues raised by 3D CBCT and moreover by truncated projections are still poorly understood. Approach. We compare different carefully designed optimization schemes in the context of realistic 3D dental imaging. Besides some known algorithms, SIRT-TV and MLEM, we investigate the primal-dual hybrid gradient (PDHG) approach and a newly proposed MLEM-TV optimizer. The last one is alternating EM steps and TV-denoising, combination not yet investigated for CBCT. Experiments are performed on both simulated data from a 3D jaw phantom and data acquired with a dental clinical scanner. Main results. With some adaptations to the specificities of CBCT operators, PDHG and MLEM-TV algorithms provide the best reconstruction quality. These results were obtained by comparing the full-dose image with a low-dose image and an ultra low-dose image. Significance. The convergence speed of the original iterative methods is hampered by the conical geometry and significantly reduced compared to parallel geometries. We promote the pre-conditioned version of PDHG and we propose a pre-conditioned version of the MLEM-TV algorithm. To the best of our knowledge, this is the first time PDHG and convergent MLEM-TV algorithms are evaluated on experimental dental CBCT data, where constraints such as projection truncation and presence of metal have to be jointly overcome.


  • Imaging of polychromatic sources through Compton spectral reconstruction

    by Enrique Muñoz, Ane Etxebeste, Denis Dauvergne, Jean Michel Létang, David Sarrut, Voichita Maxim, Etienne Testa

    Objective. Study the performance of a spectral reconstruction method for Compton imaging of polychromatic sources and compare it to standard Compton reconstruction based on the selection of photopeak events. Approach. The proposed spectral and the standard photopeak reconstruction methods are used to reconstruct images from simulated sources emitting simultaneously photons of 140, 245, 364 and 511 keV. Data are simulated with perfect and realistic energy resolutions and including Doppler broadening. We compare photopeak and spectral reconstructed images both qualitatively and quantitatively by means of activity recovery coefficient and spatial resolution. Main results. The presented method allows improving the images of polychromatic sources with respect to standard reconstruction methods. The main reasons for this improvement are the increase of available statistics and the reduction of contamination from higher initial photon energies. The reconstructed images present lower noise, higher activity recovery coefficient and better spatial resolution. The improvements become more sensible as the energy resolution of the detectors decreases. Significance. Compton cameras have been studied for their capability of imaging polychromatic sources, thus allowing simultaneous imaging of multiple radiotracers. In such scenarios, Compton images are conventionally reconstructed for each emission energy independently, selecting only those measured events depositing a total energy within a fixed window around the known emission lines. We propose to employ a spectral image reconstruction method for polychromatic sources, which allows increasing the available statistics by using the information from events with partial energy deposition. The detector energy resolution influences the energy window used to select photopeak events and therefore the level of contamination by higher energies. The spectral method is expected to have a more important impact as the detector resolution worsens. In this paper we focus on energy ranges from nuclear medical imaging and we consider realistic energy resolutions.


  • Influence of Doppler broadening model accuracy in Compton camera list-mode MLEM reconstruction

    by Yuemeng Feng, Jean Michel Létang, David Sarrut, Voichia Maxim

    The Compton camera is a gamma ray imaging device expected to provide clinically relevant images in the SPECT applications where collimated cameras are sub-optimal. Its imaging performances depend not only on the design of the detection system but also on choices related to tomographic reconstruction. The aim of this work is to show that the accuracy in modelling the acquisition largely influences the quality of the images. For this purpose, we restrict here to Doppler broadening models in conjunction with the list-mode maximum likelihood expectation maximization (LM-MLEM) algorithm. The study was carried out with Monte-Carlo simulation. We show that the reconstructed point spread function is location-dependent when the model is not accurate, and the usual elongation artefacts well-known in Compton camera imaging will appear. The model we propose allows us to reconstruct isolated point sources and more complex non-uniform sources with improved resolution even in the direction orthogonal to the camera.


  • 3-D Reconstruction Benchmark of a Compton Camera Against a Parallel-Hole Gamma Camera on Ideal Data

    by Yuemeng Feng, Ane Etxebeste, David Sarrut, Jean Michel Letang, Voichita Maxim

    Compton cameras and collimated gamma cameras are competing devices suitable for prompt gamma detection in range verification of particle therapy. In this study, we evaluate the first approach from the point of view of the tomographic reconstruction step by comparing it to the second. We clear any technological constraints by considering a simple geometry, ideal detecting stages, a mono-energetic synthetic phantom. To this end, both analytic (filtered back-projection) and iterative (list-mode maximum likelihood expectation maximization) algorithms are applied in conjunction with total variation denoising. It was shown in previous studies that compared to the mechanically collimated camera, the Compton camera has a higher efficiency. Factors between ten and one hundred were reported. Meanwhile, for each detected event the emission position of the original photon lies on a conical surface for Compton cameras, instead of a line for collimated cameras. This leads to a supplementary degree of freedom that logically calls during image reconstruction for a larger data set and may cancel out the benefits of the superior efficiency. We consider here a static Compton camera and a rotating collimated camera with similar angular coverage. We show empirically that reconstruction from conical projections requires ten times more detected events to obtain at least the same image quality. In some experiments, the Compton camera allows to avoid severe artefacts produced by the limited-angle geometry of the collimated camera. In addition, the Compton camera should be better suited for imaging high-energy and poly-energetic sources.


  • Monitoring Ion Beam Therapy With a Compton Camera: Simulation Studies of the Clinical Feasibility

    by M. Fontana, J.-L. Ley, D. Dauvergne, N. Freud, J. Krimmer, J. M. Letang, V. Maxim, M.-H. Richard, I. Rinaldi, E. Testa

    As more and more particle therapy centers are being built world-wide, there is increasing need in treatment monitoring methods, ideally in real-time. The present work investigates the clinical applicability of a Compton camera design by means of Monte Carlo simulations. The Compton camera performance has been studied with the simulation of point-like source and beam irradiation of a PMMA phantom. The system absolute photon detection efficiency, measured via source irradiation, varies in the range 1,4 ×10-4 with energy variations in the prompt gamma energy range and source position shifts with respect to the center of the camera. With proton and carbon beams impinging on a PMMA cylindrical phantom, the number of detected prompt-gamma coincidences related to various beam time structure has been studied. Finally, the accuracy of the camera in identifying the dose profile fall-off position has been estimated and two different event reconstruction methods have been compared for this purpose; one based on analytical calculation with a line-cone technique, the second relying on an iterative MLEM algorithm. Both methods showed the possibility to reconstruct the beam depth-dose profile and to retrieve the dose fall-off with millimeter precision on a spot basis.


  • Enhancement of Compton camera images reconstructed by inversion of a conical Radon transform

    by Voichiţa Maxim

    We present a new inversion formula for a weighted conical Radon transform modelling Compton camera data. The formula exploits a large proportion of the acquired events and is easy to implement into fast algorithms. We give for it two equivalent formulations relying on known properties of the two-dimensional Radon transform and we test a semi-iterative algorithm for one of them. From a practical point of view, methods robust to measurement noise and to low number of events are required. We show that adding a constraint on the total variation of the final image strongly improves the results. We illustrate our arguments with Monte-Carlo simulated data in both low and realistic noise configurations.


  • Open Access

    Image deconvolution for fast Tomography in Environmental Transmission Electron Microscopy

    by Yue‐Meng Feng, Khanh Tran, Siddardha Koneti, Lucian Roiban, Anne‐Sophie Gay, Cyril Langlois, Thierry Epicier, Thomas Grenier, Voichita Maxim