Yuemeng Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yuemeng Feng has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Hamid Sabet
Massachusetts General Hospital
6 shared publications - Voichita Maxim
CREATIS, INSA de Lyon, Bâtiment Blaise Pascal, 7 Avenue Jean Capelle, Villeurbanne, 69621 Cedex , FRANCE
3 shared publications - William Worstell
PicoRad Imaging LLC, PicoRad Imaging LLC, MA, Wayland, US 01778, UNITED STATES
3 shared publications - David Sarrut
Centre Léon Bérard, CREATIS, 28 rue Laënnec, LYON, 69373, FRANCE
2 shared publications - Georges El Fakhri
Yale University
2 shared publications - Jean Michel Létang
CREATIS, 69621 Villeurbanne cedex, Villeurbanne, 69621, France
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (8) , 1289-1308
Evaluation of a Compton Camera System for Whole-Body Imaging of Ac-225: A Simulation Study
In this study, we introduce a Compton camera system design for whole-body imaging of Actinium-225 (225Ac), one of the trending radionuclides for targeted alpha therapy (TAT). The system enables multi-energy gamma photon detection with higher efficiency compared to mechanically collimated SPECT. This design consists of two detectors made of Cadmium zinc telluride (CZT), providing a field of view (FOV) adequate for whole-body imaging, while achieving high sensitivity and clinically usable imaging resolution within a reasonable scanning time. This work focuses on the system design and evaluation using the Monte Carlo simulation toolkit GATE. The imaging performance is evaluated at two energy peaks (218 keV, 440 keV) by applying the energy windows of 211-225 keV and 430-450 keV, representing the major detectable gamma energies generated from 225Ac. We explore the possibility of using the Compton camera system for treatment response monitoring in TAT. The full decay chain of 225Ac is simulated. Results demonstrate an image resolution of 1.0 cm using a NEMA IQ phantom with 5.7 MBq of 225Ac simulated in a cold background. An image resolution of 1.3 cm can be achieved with a hot-to-background ratio of 30:1, and a resolution of 3.7 cm can be achieved with an activity ratio of 12:1. The best achievable sensitivity at a 10 cm distance from the detector is 0.5% at 218 keV and 0.45% at 440 keV as calculated using a pure gamma source in the simulation. The proposed system may serve as an alternative imaging tool for TAT scanning in clinical settings.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (8) , 1289-1308
Evaluation of a Compton Camera System for Whole-Body Imaging of Ac-225: A Simulation Study
In this study, we introduce a Compton camera system design for whole-body imaging of Actinium-225 (225Ac), one of the trending radionuclides for targeted alpha therapy (TAT). The system enables multi-energy gamma photon detection with higher efficiency compared to mechanically collimated SPECT. This design consists of two detectors made of Cadmium zinc telluride (CZT), providing a field of view (FOV) adequate for whole-body imaging, while achieving high sensitivity and clinically usable imaging resolution within a reasonable scanning time. This work focuses on the system design and evaluation using the Monte Carlo simulation toolkit GATE. The imaging performance is evaluated at two energy peaks (218 keV, 440 keV) by applying the energy windows of 211-225 keV and 430-450 keV, representing the major detectable gamma energies generated from 225Ac. We explore the possibility of using the Compton camera system for treatment response monitoring in TAT. The full decay chain of 225Ac is simulated. Results demonstrate an image resolution of 1.0 cm using a NEMA IQ phantom with 5.7 MBq of 225Ac simulated in a cold background. An image resolution of 1.3 cm can be achieved with a hot-to-background ratio of 30:1, and a resolution of 3.7 cm can be achieved with an activity ratio of 12:1. The best achievable sensitivity at a 10 cm distance from the detector is 0.5% at 218 keV and 0.45% at 440 keV as calculated using a pure gamma source in the simulation. The proposed system may serve as an alternative imaging tool for TAT scanning in clinical settings.
- 31 December 2025
- Published by Index Copernicus in Bio-Algorithms and Med-Systems
- Vol. 21 (1) , 1-16
Limited-angle TOF-PET for intraoperative surgical applications: a simulation study
Objectives: We present simulation results of a limited-angle TOF-PET system designed for intraoperative surgical applications. The purpose of this study is to show effects of various detector parameters on the resolution of reconstructed images. Methods: All simulated system configurations, and parameters were performed in GATE Monte Carlo package. In our simulation setup, detector modules typically used in whole-body PET imaging were arranged in two parallel planes: one positioned above the patient's body and the other beneath the patient/surgery bed. We simulated a phantom consisting of a cold sphere with a diameter of 15 mm and four hot sphere regions with sphere diameters of 8 mm, 6 mm, 4 mm, and 2 mm. Several parameters are simulated, including depth-of-interaction (DOI), full width at half maximum (FWHM) of the coincidence time resolution (CTR), crystal thickness, pixel size, uptake ratio and background water depth. To assess image resolution, we employed Simple Back Projection (SBP) reconstruction due to its fast speed compared to list-mode Maximum Likelihood Expectation Maximization (MLEM). We evaluated the quality of the reconstructed images using contrast-to-noise ratio (CNR), contrast recovery coefficient (CRC), and signal-to-noise ratio (SNR) metrics. The data acquisition length was set to 1 minute. Results and conclusions: Different parameters are simulated and impacts on the reconstructed image resolution are evaluated. Using detectors with 100 ps CTR, it is possible to detect 4 mm spheres with a 12 cm thickness of warm background, even with a low uptake ratio (5:1). Additionally, in the same thickness, 2 mm spheres with a larger uptake ratio (10:1) can be resolved with a 50 ps CTR. Our results indicate that with 1 minute acquisition and high timing resolution, use of intraoperative imaging with high resolution is achievable.
- 31 December 2025
- Published by Index Copernicus in Bio-Algorithms and Med-Systems
- Vol. 21 (1) , 1-16
Limited-angle TOF-PET for intraoperative surgical applications: a simulation study
Objectives: We present simulation results of a limited-angle TOF-PET system designed for intraoperative surgical applications. The purpose of this study is to show effects of various detector parameters on the resolution of reconstructed images. Methods: All simulated system configurations, and parameters were performed in GATE Monte Carlo package. In our simulation setup, detector modules typically used in whole-body PET imaging were arranged in two parallel planes: one positioned above the patient's body and the other beneath the patient/surgery bed. We simulated a phantom consisting of a cold sphere with a diameter of 15 mm and four hot sphere regions with sphere diameters of 8 mm, 6 mm, 4 mm, and 2 mm. Several parameters are simulated, including depth-of-interaction (DOI), full width at half maximum (FWHM) of the coincidence time resolution (CTR), crystal thickness, pixel size, uptake ratio and background water depth. To assess image resolution, we employed Simple Back Projection (SBP) reconstruction due to its fast speed compared to list-mode Maximum Likelihood Expectation Maximization (MLEM). We evaluated the quality of the reconstructed images using contrast-to-noise ratio (CNR), contrast recovery coefficient (CRC), and signal-to-noise ratio (SNR) metrics. The data acquisition length was set to 1 minute. Results and conclusions: Different parameters are simulated and impacts on the reconstructed image resolution are evaluated. Using detectors with 100 ps CTR, it is possible to detect 4 mm spheres with a 12 cm thickness of warm background, even with a low uptake ratio (5:1). Additionally, in the same thickness, 2 mm spheres with a larger uptake ratio (10:1) can be resolved with a 50 ps CTR. Our results indicate that with 1 minute acquisition and high timing resolution, use of intraoperative imaging with high resolution is achievable.
- 18 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 145031
Analytical methods for system matrix calculation and spatial resolution evaluation of DC-SPECT system
Objective. To develop and evaluate an analytical method for calculating the system matrix of a dynamic cardiac single photon emission computed tomography (DC-SPECT) system, eliminating the need for computationally intensive Monte Carlo (MC) simulations. Approach. An analytical model was proposed for system matrix generation, incorporating solid angle calculations adapted for square-shaped pinhole collimators. The resulting sensitivity maps were validated against MC simulation results. Image reconstructions using the proposed analytical model were compared to those using an MC-simulated system matrix. Additionally, the overall system performance, including sensitivity and spatial resolution, was assessed using MC simulations. Main results. The analytical sensitivity map showed good agreement with MC-based results. Reconstructed images using the analytical model preserved key features but showed reduced performance compared to MC-based reconstructions. MC simulations of DC-SPECT demonstrated a spatial resolution of 5.5 mm for hot regions and 6.0 mm for cold regions, with an overall system sensitivity of 0.07% over a 15 cm diameter spherical field of view. Significance. The proposed analytical method offers a fast and practical alternative to MC-based system matrix generation, enabling efficient system design and prototyping. While its use in clinical image reconstruction requires further evaluation, the model provides a promising tool for accelerating the development of next-generation DC-SPECT systems.
- 18 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 145031
Analytical methods for system matrix calculation and spatial resolution evaluation of DC-SPECT system
Objective. To develop and evaluate an analytical method for calculating the system matrix of a dynamic cardiac single photon emission computed tomography (DC-SPECT) system, eliminating the need for computationally intensive Monte Carlo (MC) simulations. Approach. An analytical model was proposed for system matrix generation, incorporating solid angle calculations adapted for square-shaped pinhole collimators. The resulting sensitivity maps were validated against MC simulation results. Image reconstructions using the proposed analytical model were compared to those using an MC-simulated system matrix. Additionally, the overall system performance, including sensitivity and spatial resolution, was assessed using MC simulations. Main results. The analytical sensitivity map showed good agreement with MC-based results. Reconstructed images using the analytical model preserved key features but showed reduced performance compared to MC-based reconstructions. MC simulations of DC-SPECT demonstrated a spatial resolution of 5.5 mm for hot regions and 6.0 mm for cold regions, with an overall system sensitivity of 0.07% over a 15 cm diameter spherical field of view. Significance. The proposed analytical method offers a fast and practical alternative to MC-based system matrix generation, enabling efficient system design and prototyping. While its use in clinical image reconstruction requires further evaluation, the model provides a promising tool for accelerating the development of next-generation DC-SPECT systems.
- Open Access
- 5 December 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (1) , 015009
Resolution recovery on list mode MLEM reconstruction for dynamic cardiac SPECT system
The Dynamic Cardiac SPECT (DC-SPECT) system is being developed at the Massachusetts General Hospital, featuring a static cardio focus asymmetrical geometry enabling simultaneous high-resolution and high-sensitivity imaging. Among 14 design iterations of the DC-SPECT with varying number of detector heads, system sensitivity and resolution, the current version under development features 10 mm FWHM geometrical resolution (without resolution recovery) and 0.07% sensitivity at the center of the FOV, this is 1.5× resolution gain and 7× sensitivity gain compared to a conventional dual head gamma camera (0.01% sensitivity and 15-mm resolution). This work presents improvement in imaging resolution by implementing a spatially variant point spread function (SV-PSF) with list mode MLEM reconstruction. A resolution recovery method by PSF deconvolution is validated on list mode MLEM reconstruction for the DC-SPECT. A spatial invariant PSF is included as an additional test to show the influence of the PSF modelling accuracy on reconstructed image quality. We compare the MLEM reconstruction with and without PSF deconvolution; an analytic model is used for the calculation of system response, and the results are compared to the reconstruction with system modelling using Monte Carlo (MC) based methods. Results show that with PSF modelling applied, the quality of the reconstructed image is improved, and the DC-SPECT system can achieve a 4.5 mm central spatial resolution with average 795 counts/Mbq. Both the SV-PSF and the spatial-invariant PSF improve the image quality, and the reconstruction with SV-PSF generates line profiles closer to the ground truth. The results show substantial improvement over the GE Discovery 570c performance (7 mm spatial resolution with an average 460 counts/MBq, 5.8 mm resolution at the FOV center). The impact of PSF deconvolution is significant, improvement of the reconstructed image quality is evident in comparison to MC simulated system matrix with the same sampling size in the simulation.
- 5 December 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (1) , 015009
Open AccessResolution recovery on list mode MLEM reconstruction for dynamic cardiac SPECT system
The Dynamic Cardiac SPECT (DC-SPECT) system is being developed at the Massachusetts General Hospital, featuring a static cardio focus asymmetrical geometry enabling simultaneous high-resolution and high-sensitivity imaging. Among 14 design iterations of the DC-SPECT with varying number of detector heads, system sensitivity and resolution, the current version under development features 10 mm FWHM geometrical resolution (without resolution recovery) and 0.07% sensitivity at the center of the FOV, this is 1.5× resolution gain and 7× sensitivity gain compared to a conventional dual head gamma camera (0.01% sensitivity and 15-mm resolution). This work presents improvement in imaging resolution by implementing a spatially variant point spread function (SV-PSF) with list mode MLEM reconstruction. A resolution recovery method by PSF deconvolution is validated on list mode MLEM reconstruction for the DC-SPECT. A spatial invariant PSF is included as an additional test to show the influence of the PSF modelling accuracy on reconstructed image quality. We compare the MLEM reconstruction with and without PSF deconvolution; an analytic model is used for the calculation of system response, and the results are compared to the reconstruction with system modelling using Monte Carlo (MC) based methods. Results show that with PSF modelling applied, the quality of the reconstructed image is improved, and the DC-SPECT system can achieve a 4.5 mm central spatial resolution with average 795 counts/Mbq. Both the SV-PSF and the spatial-invariant PSF improve the image quality, and the reconstruction with SV-PSF generates line profiles closer to the ground truth. The results show substantial improvement over the GE Discovery 570c performance (7 mm spatial resolution with an average 460 counts/MBq, 5.8 mm resolution at the FOV center). The impact of PSF deconvolution is significant, improvement of the reconstructed image quality is evident in comparison to MC simulated system matrix with the same sampling size in the simulation.
- 4 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
VPG4, Versatile Parallelizable Geant4 Interface: A Novel Platform for Modeling Complex Nuclear Medicine Imaging Scanners
In this work, we present a new Geant4-based simulation modeling platform for complex nuclear medicine imaging scanners that uses computer-aided design (CAD) tools and parallelization on both CPU and GPU to accelerate the Monte Carlo simulation and reduce computational cost. The application combines the newly developed open-source GDML package and the new version of open-source Opticks code to create simulation models for complex structures. We demonstrate that the application is suitable for imaging scanners with complex structures, and we show that the computational cost is significantly decreased. Our results show the computational efficiency enhanced over two orders of magnitudes using both GPU and CPU. Our application has the potential to make the simulation of complex imaging systems more accessible and efficient for new users of nuclear Monte Carlo codes. Also, we plan to extend this work to include other modalities and to examine the performance of more complex structures.
- 4 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
VPG4, Versatile Parallelizable Geant4 Interface: A Novel Platform for Modeling Complex Nuclear Medicine Imaging Scanners
In this work, we present a new Geant4-based simulation modeling platform for complex nuclear medicine imaging scanners that uses computer-aided design (CAD) tools and parallelization on both CPU and GPU to accelerate the Monte Carlo simulation and reduce computational cost. The application combines the newly developed open-source GDML package and the new version of open-source Opticks code to create simulation models for complex structures. We demonstrate that the application is suitable for imaging scanners with complex structures, and we show that the computational cost is significantly decreased. Our results show the computational efficiency enhanced over two orders of magnitudes using both GPU and CPU. Our application has the potential to make the simulation of complex imaging systems more accessible and efficient for new users of nuclear Monte Carlo codes. Also, we plan to extend this work to include other modalities and to examine the performance of more complex structures.
- 8 June 2023
- Published by Springer Nature in Numerical Algorithms
- Vol. 94 (2) , 701-731
Tomographic reconstruction from Poisson distributed data: a fast and convergent EM-TV dual approach
- 8 June 2023
- Published by Springer Nature in Numerical Algorithms
- Vol. 94 (2) , 701-731
Tomographic reconstruction from Poisson distributed data: a fast and convergent EM-TV dual approach
- 12 December 2021
- Published by Taylor & Francis in Inverse Problems in Science and Engineering
- Vol. 29 (13) , 3509-3529
Influence of Doppler broadening model accuracy in Compton camera list-mode MLEM reconstruction
The Compton camera is a gamma ray imaging device expected to provide clinically relevant images in the SPECT applications where collimated cameras are sub-optimal. Its imaging performances depend not only on the design of the detection system but also on choices related to tomographic reconstruction. The aim of this work is to show that the accuracy in modelling the acquisition largely influences the quality of the images. For this purpose, we restrict here to Doppler broadening models in conjunction with the list-mode maximum likelihood expectation maximization (LM-MLEM) algorithm. The study was carried out with Monte-Carlo simulation. We show that the reconstructed point spread function is location-dependent when the model is not accurate, and the usual elongation artefacts well-known in Compton camera imaging will appear. The model we propose allows us to reconstruct isolated point sources and more complex non-uniform sources with improved resolution even in the direction orthogonal to the camera.
- 12 December 2021
- Published by Taylor & Francis in Inverse Problems in Science and Engineering
- Vol. 29 (13) , 3509-3529
Influence of Doppler broadening model accuracy in Compton camera list-mode MLEM reconstruction
The Compton camera is a gamma ray imaging device expected to provide clinically relevant images in the SPECT applications where collimated cameras are sub-optimal. Its imaging performances depend not only on the design of the detection system but also on choices related to tomographic reconstruction. The aim of this work is to show that the accuracy in modelling the acquisition largely influences the quality of the images. For this purpose, we restrict here to Doppler broadening models in conjunction with the list-mode maximum likelihood expectation maximization (LM-MLEM) algorithm. The study was carried out with Monte-Carlo simulation. We show that the reconstructed point spread function is location-dependent when the model is not accurate, and the usual elongation artefacts well-known in Compton camera imaging will appear. The model we propose allows us to reconstruct isolated point sources and more complex non-uniform sources with improved resolution even in the direction orthogonal to the camera.
- 16 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
First Investigation of List mode MLEM Reconstruction for Fast DC-SPECT System Design Optimization
A Dynamic Cardiac SPECT (DC-SPECT) system is being developed at the Massachusetts General Hospital, Harvard, featuring a cardio focus asymmetrical geometry to enable simultaneous high resolution and high sensitivity. We have generated 14 design iterations of the DC-SPECT with varying number of detector heads, system sensitivity, and system resolution. In such asymmetrical geometry the life cycle of design optimization from mechanical drawing to Monte Carlo implementation to image reconstruction and evaluation is long and labor intensive. This work presents a first implementation of List Mode Maximum Likelihood Expectation Maximization (LM-MLEM) reconstruction for the DC-SPECT system to enable fast design optimization using analytical method. We investigate the DC-SPECT system imaging resolution by applying a simple system modeling while implementing LM-MLEM. Results show that without any correction of scattering or attenuation effects, LM-MLEM reconstruction can achieve a 5 mm FWHM spatial resolution. The results agree with the expected performance of the DC-SPECT. Specifically, we show the advantages of analytic based system matrix model over Monte-Carlo (MC) based models. A comparison between images reconstructed by analytic modeling and MC methods is presented.
- 16 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
First Investigation of List mode MLEM Reconstruction for Fast DC-SPECT System Design Optimization
A Dynamic Cardiac SPECT (DC-SPECT) system is being developed at the Massachusetts General Hospital, Harvard, featuring a cardio focus asymmetrical geometry to enable simultaneous high resolution and high sensitivity. We have generated 14 design iterations of the DC-SPECT with varying number of detector heads, system sensitivity, and system resolution. In such asymmetrical geometry the life cycle of design optimization from mechanical drawing to Monte Carlo implementation to image reconstruction and evaluation is long and labor intensive. This work presents a first implementation of List Mode Maximum Likelihood Expectation Maximization (LM-MLEM) reconstruction for the DC-SPECT system to enable fast design optimization using analytical method. We investigate the DC-SPECT system imaging resolution by applying a simple system modeling while implementing LM-MLEM. Results show that without any correction of scattering or attenuation effects, LM-MLEM reconstruction can achieve a 5 mm FWHM spatial resolution. The results agree with the expected performance of the DC-SPECT. Specifically, we show the advantages of analytic based system matrix model over Monte-Carlo (MC) based models. A comparison between images reconstructed by analytic modeling and MC methods is presented.
- 12 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (5) , 651-661
Measurement of the Parametrized Single-Photon Response Function of a Large Area Picosecond Photodetector for Time-of-Flight PET Applications
We have used a sub-picosecond laser with an output trigger synched to a 4GHz oscilloscope sampling at 25 GSa/s to characterize the temporally resolved response of a Large Area Picosecond Photo-Detector (LAPPD) to single photons/photoelectrons. The LAPPD is a large area (20cm x 20cm) photosensor with a nanosecond-width time response arising from its underlying Multi-Channel Plate Photomultiplier Tube (MCP-PMT) structure. We used optical filters to attenuate the laser pulse intensity to single photon level. LAPPD pulses are nearly identical in shape, particularly for pulses whose peak amplitude is a large multiple of our system’s 0.6 mV rms baseline electronic noise. Three waveform timing algorithms were compared in their measurements of the transit time spread (TTS) Gaussian fitted to the distribution of measured Single Photoelectron (SPE) pulse times under zero-width laser excitation: 1) a Constant Fraction algorithm, 2) a Pulse Centroid Timing algorithm, and 3) a Pulse Model Fitting algorithm. The measured SPE values with the three algorithms are: 79 ± 17, 67 ± 15, and 82 ± 20 ps Gaussian sigma, respectively. The LAPPD provides independent voltage control for its photocathode, and at the entry and entry faces of its Chevron Pair of MCPs. We found no or minimal change in TTS with photocathode voltage for pulses >15mV.
- 12 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (5) , 651-661
Measurement of the Parametrized Single-Photon Response Function of a Large Area Picosecond Photodetector for Time-of-Flight PET Applications
We have used a sub-picosecond laser with an output trigger synched to a 4GHz oscilloscope sampling at 25 GSa/s to characterize the temporally resolved response of a Large Area Picosecond Photo-Detector (LAPPD) to single photons/photoelectrons. The LAPPD is a large area (20cm x 20cm) photosensor with a nanosecond-width time response arising from its underlying Multi-Channel Plate Photomultiplier Tube (MCP-PMT) structure. We used optical filters to attenuate the laser pulse intensity to single photon level. LAPPD pulses are nearly identical in shape, particularly for pulses whose peak amplitude is a large multiple of our system’s 0.6 mV rms baseline electronic noise. Three waveform timing algorithms were compared in their measurements of the transit time spread (TTS) Gaussian fitted to the distribution of measured Single Photoelectron (SPE) pulse times under zero-width laser excitation: 1) a Constant Fraction algorithm, 2) a Pulse Centroid Timing algorithm, and 3) a Pulse Model Fitting algorithm. The measured SPE values with the three algorithms are: 79 ± 17, 67 ± 15, and 82 ± 20 ps Gaussian sigma, respectively. The LAPPD provides independent voltage control for its photocathode, and at the entry and entry faces of its Chevron Pair of MCPs. We found no or minimal change in TTS with photocathode voltage for pulses >15mV.
- 26 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 4 (4) , 479-488
3-D Reconstruction Benchmark of a Compton Camera Against a Parallel-Hole Gamma Camera on Ideal Data
Compton cameras and collimated gamma cameras are competing devices suitable for prompt gamma detection in range verification of particle therapy. In this study, we evaluate the first approach from the point of view of the tomographic reconstruction step by comparing it to the second. We clear any technological constraints by considering a simple geometry, ideal detecting stages, a mono-energetic synthetic phantom. To this end, both analytic (filtered back-projection) and iterative (list-mode maximum likelihood expectation maximization) algorithms are applied in conjunction with total variation denoising. It was shown in previous studies that compared to the mechanically collimated camera, the Compton camera has a higher efficiency. Factors between ten and one hundred were reported. Meanwhile, for each detected event the emission position of the original photon lies on a conical surface for Compton cameras, instead of a line for collimated cameras. This leads to a supplementary degree of freedom that logically calls during image reconstruction for a larger data set and may cancel out the benefits of the superior efficiency. We consider here a static Compton camera and a rotating collimated camera with similar angular coverage. We show empirically that reconstruction from conical projections requires ten times more detected events to obtain at least the same image quality. In some experiments, the Compton camera allows to avoid severe artefacts produced by the limited-angle geometry of the collimated camera. In addition, the Compton camera should be better suited for imaging high-energy and poly-energetic sources.
- 26 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 4 (4) , 479-488
3-D Reconstruction Benchmark of a Compton Camera Against a Parallel-Hole Gamma Camera on Ideal Data
Compton cameras and collimated gamma cameras are competing devices suitable for prompt gamma detection in range verification of particle therapy. In this study, we evaluate the first approach from the point of view of the tomographic reconstruction step by comparing it to the second. We clear any technological constraints by considering a simple geometry, ideal detecting stages, a mono-energetic synthetic phantom. To this end, both analytic (filtered back-projection) and iterative (list-mode maximum likelihood expectation maximization) algorithms are applied in conjunction with total variation denoising. It was shown in previous studies that compared to the mechanically collimated camera, the Compton camera has a higher efficiency. Factors between ten and one hundred were reported. Meanwhile, for each detected event the emission position of the original photon lies on a conical surface for Compton cameras, instead of a line for collimated cameras. This leads to a supplementary degree of freedom that logically calls during image reconstruction for a larger data set and may cancel out the benefits of the superior efficiency. We consider here a static Compton camera and a rotating collimated camera with similar angular coverage. We show empirically that reconstruction from conical projections requires ten times more detected events to obtain at least the same image quality. In some experiments, the Compton camera allows to avoid severe artefacts produced by the limited-angle geometry of the collimated camera. In addition, the Compton camera should be better suited for imaging high-energy and poly-energetic sources.