Ibraheem Fahad Alshiddi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ibraheem Fahad Alshiddi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Abdulaziz S. Alqahtani
Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
2 shared publications - Eman Mohammed AlHamdan
Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, P.O.Box 21069, Riyadh 11475, Saudi Arabia
2 shared publications - Fahim Vohra
Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, 11545, Saudi Arabia
2 shared publications - Samar Al-Saleh
Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
2 shared publications - Tariq Abduljabbar
Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, 11545, Saudi Arabia
2 shared publications A M Al-Zaid
1 shared publication
Latest Publications
- Open Access
Application of β-Tricalcium Phosphate in Adhesive Dentin Bonding
The study aimed at synthesizing β-tricalcium phosphate (β-TCP) nanoparticles and comparing the mechanical properties and dentin interaction of two adhesives: experimental adhesive (EA) and EA with 5 wt.% β-TCP nanoparticles (β-TCP-5%). These filler nanoparticles were synthesized and then characterized with scanning electron microscopy (SEM) and micro-Raman spectroscopy. The β-TCP nanoparticles were incorporated in the adhesives to form two groups: gp-1: EA (control) and gp-2: β-TCP-5%. These adhesives were characterized by SEM, energy-dispersive X-ray (EDX) spectroscopy and were also assessed for their micro-tensile bond strength (μTBS) with (TC) and without thermocycling (NTC). Fourier Transform Infrared (FTIR) spectroscopy was performed to evaluate the degree of conversion (DC) of two adhesives. The β-TCP filler was seen as irregularly shaped agglomerates on SEM. The micro-Raman spectra revealed characteristic peaks associated with β-TCP nanoparticles. Both adhesives presented suitable dentin interaction, which was demonstrated by the formation of resin tags of variable depths. The EDX analysis verified the existence of calcium (Ca) and phosphate (P) for the β-TCP-5% group. The greatest μTBS values were shown by β-TCP-5% group samples when they were non-thermocycled (NTC) (β-TCP-5%-NTC: 34.11 ± 3.46) followed by the thermocycled (TC) samples of the same group (β-TCP-5%-TC: 30.38 ± 3.66), compared with the EA group. Although the DC presented by β-TCP-5% group was comparable to the EA group, it was still lower. The addition of β-TCP nanoparticles in the adhesive improved its μTBS and resulted in a suitable dentin interaction, seen in the form of hybrid layer and resin tag formation. Nonetheless, a decreased DC was observed for the β-TCP-5% adhesive. Future studies probing the effect of different filler concentrations on various properties of the adhesive are warranted.
Open AccessApplication of β-Tricalcium Phosphate in Adhesive Dentin Bonding
The study aimed at synthesizing β-tricalcium phosphate (β-TCP) nanoparticles and comparing the mechanical properties and dentin interaction of two adhesives: experimental adhesive (EA) and EA with 5 wt.% β-TCP nanoparticles (β-TCP-5%). These filler nanoparticles were synthesized and then characterized with scanning electron microscopy (SEM) and micro-Raman spectroscopy. The β-TCP nanoparticles were incorporated in the adhesives to form two groups: gp-1: EA (control) and gp-2: β-TCP-5%. These adhesives were characterized by SEM, energy-dispersive X-ray (EDX) spectroscopy and were also assessed for their micro-tensile bond strength (μTBS) with (TC) and without thermocycling (NTC). Fourier Transform Infrared (FTIR) spectroscopy was performed to evaluate the degree of conversion (DC) of two adhesives. The β-TCP filler was seen as irregularly shaped agglomerates on SEM. The micro-Raman spectra revealed characteristic peaks associated with β-TCP nanoparticles. Both adhesives presented suitable dentin interaction, which was demonstrated by the formation of resin tags of variable depths. The EDX analysis verified the existence of calcium (Ca) and phosphate (P) for the β-TCP-5% group. The greatest μTBS values were shown by β-TCP-5% group samples when they were non-thermocycled (NTC) (β-TCP-5%-NTC: 34.11 ± 3.46) followed by the thermocycled (TC) samples of the same group (β-TCP-5%-TC: 30.38 ± 3.66), compared with the EA group. Although the DC presented by β-TCP-5% group was comparable to the EA group, it was still lower. The addition of β-TCP nanoparticles in the adhesive improved its μTBS and resulted in a suitable dentin interaction, seen in the form of hybrid layer and resin tag formation. Nonetheless, a decreased DC was observed for the β-TCP-5% adhesive. Future studies probing the effect of different filler concentrations on various properties of the adhesive are warranted.
- Open Access
Fracture Load of CAD/CAM Fabricated Cantilever Implant-Supported Zirconia Framework: An In Vitro Study
The fracture resistance of computer-aided designing and computer-aided manufacturing CAD/CAM fabricated implant-supported cantilever zirconia frameworks (ISCZFs) is affected by the size/dimension and the micro cracks produced from diamond burs during the milling process. The present in vitro study investigated the fracture load for different cross-sectional dimensions of connector sites of implant-supported cantilever zirconia frameworks (ISCZFs) with different cantilever lengths (load point). A total of 48 ISCZFs (Cercon, Degudent; Dentsply, Deutschland, Germany) were fabricated by CAD/CAM and divided into four groups based on cantilever length and reinforcement of distal-abutment: Group A: 9 mm cantilever; Group B: 9 mm cantilever with reinforced distal-abutment; Group C: 12 mm cantilever; Group D: 12 mm cantilever with reinforced distal-abutment (n = 12). The ISCZFs were loaded using a universal testing machine for recording the fracture load. Descriptive statistics, ANOVA, and Tukey’s test were used for the statistical analysis (p < 0.05). Significant variations were found between the fracture loads of the four ISCZFs (p = 0.000); Group-C and B were found with the weakest and the strongest distal cantilever frameworks with fracture load of 670.39 ± 130.96 N and 1137.86 ± 127.85 N, respectively. The mean difference of the fracture load between groups A (810.49 + 137.579 N) and B (1137.86 ± 127.85 N) and between C (670.39 ± 130.96 N) and D (914.58 + 149.635 N) was statistically significant (p = 0.000). Significant variations in the fracture load between the ISCZFs with different cantilever lengths and thicknesses of the distal abutments were found. Increasing the thickness of the distal abutment only by 0.5 mm reinforces the distal abutments by significantly increasing the fracture load of the ISCZFs. Therefore, an increase in the thickness of the distal abutments is recommended in patients seeking implant-supported distal cantilever fixed prostheses.
Open AccessFracture Load of CAD/CAM Fabricated Cantilever Implant-Supported Zirconia Framework: An In Vitro Study
The fracture resistance of computer-aided designing and computer-aided manufacturing CAD/CAM fabricated implant-supported cantilever zirconia frameworks (ISCZFs) is affected by the size/dimension and the micro cracks produced from diamond burs during the milling process. The present in vitro study investigated the fracture load for different cross-sectional dimensions of connector sites of implant-supported cantilever zirconia frameworks (ISCZFs) with different cantilever lengths (load point). A total of 48 ISCZFs (Cercon, Degudent; Dentsply, Deutschland, Germany) were fabricated by CAD/CAM and divided into four groups based on cantilever length and reinforcement of distal-abutment: Group A: 9 mm cantilever; Group B: 9 mm cantilever with reinforced distal-abutment; Group C: 12 mm cantilever; Group D: 12 mm cantilever with reinforced distal-abutment (n = 12). The ISCZFs were loaded using a universal testing machine for recording the fracture load. Descriptive statistics, ANOVA, and Tukey’s test were used for the statistical analysis (p < 0.05). Significant variations were found between the fracture loads of the four ISCZFs (p = 0.000); Group-C and B were found with the weakest and the strongest distal cantilever frameworks with fracture load of 670.39 ± 130.96 N and 1137.86 ± 127.85 N, respectively. The mean difference of the fracture load between groups A (810.49 + 137.579 N) and B (1137.86 ± 127.85 N) and between C (670.39 ± 130.96 N) and D (914.58 + 149.635 N) was statistically significant (p = 0.000). Significant variations in the fracture load between the ISCZFs with different cantilever lengths and thicknesses of the distal abutments were found. Increasing the thickness of the distal abutment only by 0.5 mm reinforces the distal abutments by significantly increasing the fracture load of the ISCZFs. Therefore, an increase in the thickness of the distal abutments is recommended in patients seeking implant-supported distal cantilever fixed prostheses.
- Open Access
- 1 January 2016
- Published by Springer Nature in The Saudi Dental Journal
- Vol. 28 (1) , 49-55
Fracture resistance of endodontically treated teeth restored with indirect composite inlay and onlay restorations – An in vitro study
The purpose of this in vitro study was to evaluate and compare the fracture resistance and fracture mode of extensive indirect inlay and onlay composite resin restorations performed for endodontically treated premolars. A total of 55 extracted maxillary premolars were randomly divided into four groups. The first group (n = 15) remained untreated to serve as a positive control; the second group (n = 15) was endodontically treated with inlay cavities prepared and restored with indirect composite inlay restorations; the third group (n = 15) was also endodontically treated with onlay cavities prepared and restored with indirect composite onlay restorations; and the fourth group (n = 10) was endodontically treated with mesio-occlusodistal (MOD) cavities prepared and left unrestored to serve as negative controls. Dual cure indirect composite resin was used to fabricate the inlay and onlay restorations performed for the second and third groups, respectively. All teeth were subjected to compressive axial loading test using a metal ball (6 mm in diameter) in a universal testing machine (Instron 1195) with a cross-head speed of 0.5 mm/min until a fracture occurred. Statistical analysis of fracture resistance and fracture mode were performed with analysis of variance (ANOVA) (α = 0.05) and Kruskal-Wallis (α = 0.05) tests, respectively. For the four treatment groups, the mean fracture resistance values were 1326.9 N, 1500.1 N, 1006.1 N, and 702.7 N, respectively. Statistical analyses showed no significant differences between the mean fracture resistance of the intact tooth group and the inlay restoration group (p > 0.05), while significant differences were observed between the mean fracture resistance of all the other groups (p < 0.05). The Kruskal-Wallis test showed statistically significant differences between the fracture modes of the four groups. Within the limitations of this study, endodontically treated teeth were successfully restored with indirect composite inlay and onlay restorations. However, the fractures that accompanied the inlay restorations were more severe and were unable to be restored.
- 1 January 2016
- Published by Springer Nature in The Saudi Dental Journal
- Vol. 28 (1) , 49-55
Open AccessFracture resistance of endodontically treated teeth restored with indirect composite inlay and onlay restorations – An in vitro study
The purpose of this in vitro study was to evaluate and compare the fracture resistance and fracture mode of extensive indirect inlay and onlay composite resin restorations performed for endodontically treated premolars. A total of 55 extracted maxillary premolars were randomly divided into four groups. The first group (n = 15) remained untreated to serve as a positive control; the second group (n = 15) was endodontically treated with inlay cavities prepared and restored with indirect composite inlay restorations; the third group (n = 15) was also endodontically treated with onlay cavities prepared and restored with indirect composite onlay restorations; and the fourth group (n = 10) was endodontically treated with mesio-occlusodistal (MOD) cavities prepared and left unrestored to serve as negative controls. Dual cure indirect composite resin was used to fabricate the inlay and onlay restorations performed for the second and third groups, respectively. All teeth were subjected to compressive axial loading test using a metal ball (6 mm in diameter) in a universal testing machine (Instron 1195) with a cross-head speed of 0.5 mm/min until a fracture occurred. Statistical analysis of fracture resistance and fracture mode were performed with analysis of variance (ANOVA) (α = 0.05) and Kruskal-Wallis (α = 0.05) tests, respectively. For the four treatment groups, the mean fracture resistance values were 1326.9 N, 1500.1 N, 1006.1 N, and 702.7 N, respectively. Statistical analyses showed no significant differences between the mean fracture resistance of the intact tooth group and the inlay restoration group (p > 0.05), while significant differences were observed between the mean fracture resistance of all the other groups (p < 0.05). The Kruskal-Wallis test showed statistically significant differences between the fracture modes of the four groups. Within the limitations of this study, endodontically treated teeth were successfully restored with indirect composite inlay and onlay restorations. However, the fractures that accompanied the inlay restorations were more severe and were unable to be restored.
- Open Access
- 1 January 2015
- Published by Open Access Text Pvt, Ltd. in Dental, Oral and Craniofacial Research
- Vol. 1 (4)
Attitude and awareness of dental students and interns toward infection control measures in prosthodontic clinics
OA Text is an independent open-access scientific publisher showcases innovative research and ideas aimed at improving health by linking research and practice to the benefit of society.
- 1 January 2015
- Published by Open Access Text Pvt, Ltd. in Dental, Oral and Craniofacial Research
- Vol. 1 (4)
Open AccessAttitude and awareness of dental students and interns toward infection control measures in prosthodontic clinics
OA Text is an independent open-access scientific publisher showcases innovative research and ideas aimed at improving health by linking research and practice to the benefit of society.
- Open Access
- 1 January 2015
- Published by Medknow in Contemporary Clinical Dentistry
- Vol. 6 (5) , 122-5
Accurate registration of peri-implant soft tissues to create an optimal emergence profile
One of the challenges in restoring anterior space with implant restoration is maintaining the natural looking of peri-implant area. This case report presents a clinical procedure to create the soft tissue emergence profile for anterior maxillary teeth. A 49-year-old male presented with missing right maxillary lateral incisor. A provisional restoration was inserted 1 week after implant placement. Area of the provisional restoration related to the gingival tissue (transmucosal area) was adjusted to create an optimum emergence profile. Two months later, an indirect method was used to accurately transfer the soft peri-implant tissues to the master cast. This clinical technique minimizes surgical procedure and avoids the possibility of soft tissue collapsing that may occur during the impression procedure.
- 1 January 2015
- Published by Medknow in Contemporary Clinical Dentistry
- Vol. 6 (5) , 122-5
Open AccessAccurate registration of peri-implant soft tissues to create an optimal emergence profile
One of the challenges in restoring anterior space with implant restoration is maintaining the natural looking of peri-implant area. This case report presents a clinical procedure to create the soft tissue emergence profile for anterior maxillary teeth. A 49-year-old male presented with missing right maxillary lateral incisor. A provisional restoration was inserted 1 week after implant placement. Area of the provisional restoration related to the gingival tissue (transmucosal area) was adjusted to create an optimum emergence profile. Two months later, an indirect method was used to accurately transfer the soft peri-implant tissues to the master cast. This clinical technique minimizes surgical procedure and avoids the possibility of soft tissue collapsing that may occur during the impression procedure.
- 1 September 2014
- Vol. 13 (3) , 707-11
Comparing government (school) vs. private (non-school) dental laboratories in marginal adaptation of single porcelain-fused-to-metal crowns.
The purpose of this study was to compare school and non-school dental laboratories in marginal adaptation of single Porcelain-Fused-to-Metal (PFM) crowns. Six dental laboratories (three school- and three non-school laboratories) participated in this study. Each dental laboratory was requested to fabricate PFM crowns for three different ivorine teeth on different typodont jaw models (n=18). The crowns received from the laboratories and fitted in their abutments using fit-checker under uniform pressure. We examined 162 sites viewed under a scanning electron microscope to measure the vertical and horizontal marginal discrepancy. The mean vertical marginal discrepancy for school dental laboratories was 208.9 µm, while for non-school dental laboratories was 182.8 µm. For the horizontal marginal discrepancy, the median values were 48.5 µm for school dental laboratories and 50 µm for non-school dental laboratories. There was no statistically significant difference in the mean vertical and median horizontal values between school and non-school dental laboratories. However, a significant difference was observed within the non-school laboratories.
- 1 September 2014
- Vol. 13 (3) , 707-11
Comparing government (school) vs. private (non-school) dental laboratories in marginal adaptation of single porcelain-fused-to-metal crowns.
The purpose of this study was to compare school and non-school dental laboratories in marginal adaptation of single Porcelain-Fused-to-Metal (PFM) crowns. Six dental laboratories (three school- and three non-school laboratories) participated in this study. Each dental laboratory was requested to fabricate PFM crowns for three different ivorine teeth on different typodont jaw models (n=18). The crowns received from the laboratories and fitted in their abutments using fit-checker under uniform pressure. We examined 162 sites viewed under a scanning electron microscope to measure the vertical and horizontal marginal discrepancy. The mean vertical marginal discrepancy for school dental laboratories was 208.9 µm, while for non-school dental laboratories was 182.8 µm. For the horizontal marginal discrepancy, the median values were 48.5 µm for school dental laboratories and 50 µm for non-school dental laboratories. There was no statistically significant difference in the mean vertical and median horizontal values between school and non-school dental laboratories. However, a significant difference was observed within the non-school laboratories.