Gerard B. Essink
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gerard B. Essink has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Hermie J. Hermens
Biomedical Signals and Systems Group, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, Netherlands
1 shared publication - Lex van Velsen
Roessingh Research and Development
1 shared publication - Simone T. Boerema
GGD Twente
1 shared publication - Thijs M. Tönis
Telemedicine Group, Roessingh Research and Development, P.O. Box 310, 7500 AH, Enschede, The Netherlands
1 shared publication
Latest Publications
- Open Access
Sedentary Behaviour Profiling of Office Workers: A Sensitivity Analysis of Sedentary Cut-Points
Measuring sedentary behaviour and physical activity with wearable sensors provides detailed information on activity patterns and can serve health interventions. At the basis of activity analysis stands the ability to distinguish sedentary from active time. As there is no consensus regarding the optimal cut-point for classifying sedentary behaviour, we studied the consequences of using different cut-points for this type of analysis. We conducted a battery of sitting and walking activities with 14 office workers, wearing the Promove 3D activity sensor to determine the optimal cut-point (in counts per minute (m·s−2)) for classifying sedentary behaviour. Then, 27 office workers wore the sensor for five days. We evaluated the sensitivity of five sedentary pattern measures for various sedentary cut-points and found an optimal cut-point for sedentary behaviour of 1660 × 10−3 m·s−2. Total sedentary time was not sensitive to cut-point changes within ±10% of this optimal cut-point; other sedentary pattern measures were not sensitive to changes within the ±20% interval. The results from studies analyzing sedentary patterns, using different cut-points, can be compared within these boundaries. Furthermore, commercial, hip-worn activity trackers can implement feedback and interventions on sedentary behaviour patterns, using these cut-points.
Open AccessSedentary Behaviour Profiling of Office Workers: A Sensitivity Analysis of Sedentary Cut-Points
Measuring sedentary behaviour and physical activity with wearable sensors provides detailed information on activity patterns and can serve health interventions. At the basis of activity analysis stands the ability to distinguish sedentary from active time. As there is no consensus regarding the optimal cut-point for classifying sedentary behaviour, we studied the consequences of using different cut-points for this type of analysis. We conducted a battery of sitting and walking activities with 14 office workers, wearing the Promove 3D activity sensor to determine the optimal cut-point (in counts per minute (m·s−2)) for classifying sedentary behaviour. Then, 27 office workers wore the sensor for five days. We evaluated the sensitivity of five sedentary pattern measures for various sedentary cut-points and found an optimal cut-point for sedentary behaviour of 1660 × 10−3 m·s−2. Total sedentary time was not sensitive to cut-point changes within ±10% of this optimal cut-point; other sedentary pattern measures were not sensitive to changes within the ±20% interval. The results from studies analyzing sedentary patterns, using different cut-points, can be compared within these boundaries. Furthermore, commercial, hip-worn activity trackers can implement feedback and interventions on sedentary behaviour patterns, using these cut-points.