PBPhilipp Blanke

Philipp Blanke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Philipp Blanke has a total of 177 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of the coronary artery calcium score for identifying coronary artery plaque in patients clinically referred for preventive screening with non-typical symptoms stratified by age and sex

    by Ruurt A. Jukema, Nima Nasibi, Anna Mueller, Seunghwan Kim, Edgar Argulian, John K. Khoo, Abdulaziz A. Bin Zaid, Henry Rigby, Bahram Pashaee, Ibrahim Danad, et al.


  • Open Access

    Novel Magnetic Resonance Imaging Tools for Hypertrophic Cardiomyopathy Risk Stratification

    by Fahad Alajmi, Mehima Kang, James Dundas, Alexander Haenel, Jeremy Parker, Philipp Blanke, Fionn Coghlan, John King Khoo, Abdulaziz A. Bin Zaid, Amrit Singh, et al.

    Hypertrophic cardiomyopathy (HCM) is a common genetic disorder with a well described risk of sudden cardiac death; however, risk stratification has remained a challenge. Recently, novel parameters in cardiac magnetic resonance imaging (CMR) have shown promise in helping to improve upon current risk stratification paradigms. In this manuscript, we have reviewed novel CMR risk markers and their utility in HCM. The results of the review showed that T1, extracellular volume, CMR feature tracking, and other miscellaneous novel CMR variables have the potential to improve sudden death risk stratification and may have additional roles in diagnosis and prognosis. The strengths and weaknesses of these imaging techniques, and their potential utility and implementation in HCM risk stratification are discussed.


  • Open Access

    Feasibility of Coronary Access Following Redo-TAVR for Evolut Failure: A Computed Tomography Simulation Study

    by Gilbert H.L. Tang, Julianne Spencer, Toby Rogers, Kendra J. Grubb, Patrick Gleason, Hemal Gada, Paul Mahoney, Harold L. Dauerman, John K. Forrest, Michael J. Reardon, et al.

    BACKGROUND: Coronary accessibility following redo–transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 ( P P P P <0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02701283.


  • TAVR in TAVR: Where Are We in 2023 for Management of Failed TAVR Valves?

    by David Meier, Georgios Tzimas, Mariama Akodad, Stephane Fournier, Jonathon A. Leipsic, Philipp Blanke, David A. Wood, Stephanie L. Sellers, John G. Webb, Janarthanan Sathananthan

    Purpose of Review As TAVR is increasingly performed on younger patients with a longer life expectancy, the number of redo-TAVR procedures is likely to increase in the coming years. Limited data is currently available on this sometimes challenging procedure. We provide a summary of currently published literature on management of patients with a failed transcatheter aortic valve. Recent Findings Recent registry data have increased the clinical knowledge on redo-TAVR. Additionally, numerous bench studies have provided valuable insights into the technical aspects of redo-TAVR with various combinations of valve types. Summary Redo-TAVR can be performed safely in selected cases with a high procedural success and good short-term outcomes. However, at present, the procedure remains relatively infrequent and many patients are not eligible. Bench testing can be useful to understand important concepts such as valve expansion, neoskirt, leaflet overhang, and leaflet deflection as well as their potential clinical implications.


  • Update on Transcatheter Treatment of Mitral and Tricuspid Valve Regurgitation

    by David Meier, Mariama Akodad, Georgios Tzimas, Olivier Muller, Anson Cheung, David A. Wood, Philipp Blanke, Janarthanan Sathananthan, Fabien Praz, Robert H. Boone, et al.

    Purpose of Review Mitral and tricuspid regurgitation represents a clinical challenge. They are associated with a poor prognosis, and many patients are not eligible for conventional surgery. Transcatheter therapies have been the focus of numerous studies and devices over the past decade. Here, we provide a summary of current options for transcatheter treatment of these 2 entities. Recent Findings Recent studies have demonstrated the benefits of edge-to-edge repair for increasing numbers of patients. Encouraging early results with transcatheter valve replacement are also becoming available. Summary To date, transcatheter edge-to-edge repair is currently the first-line transcatheter treatment for both mitral and tricuspid regurgitation for many patients who are not candidates for surgery. A number of transcatheter replacement devices are under development and clinical investigation but, for the most part, their current use is limited to compassionate cases or clinical trials.


  • Predicted vs Observed Valve to Coronary Distance in Valve-in-Valve TAVR

    by Georgios Tzimas, Mariama Akodad, David Meier, Jade Duchscherer, Kelsey Kalk, Russell J. Everett, Oliver Haidari, Ming-Yu A. Chuang, Stephanie L. Sellers, Danny Dvir, et al.


  • Quantification of Commissural Alignment of Balloon-Expandable THV on Fluoroscopy

    by Mariama Akodad, Georgios Tzimas, David Meier, Delaney Haugan, Hannah Gibson, Justin Ringhofer, Russell J. Everett, Janarthanan Sathananthan, David A. Wood, John G. Webb, et al.


  • Open Access

    TAVR for All? The Surgical Perspective

    by Xiling Zhang, Thomas Puehler, Derk Frank, Janarthanan Sathananthan, Stephanie Sellers, David Meier, Marcus Both, Philipp Blanke, Hatim Seoudy, Mohammed Saad, et al.

    In spite of the noninferiority of transcatheter aortic valve replacement (TAVR) in high- and intermediate-risk patients, there are still obstacles that need to be overcome before the procedure is further expanded and clinically integrated. The lack of evidence on the long-term durability of the bioprostheses used for TAVR remains of particular concern. In addition, surgery may be preferred over TAVR in patients with bicuspid aortic valve (BAV) or with concomitant pathologies such as other valve diseases (mitral regurgitation/tricuspid regurgitation), aortopathy, and coronary artery disease. In this review, we discuss and summarize relevant data from clinical trials, current trends, and remaining obstacles, and provide our perspective on the indications for the expansion of TAVR.


  • Computed tomography reference dimensions for identification of stented surgical mitral bioprostheses valve size

    by Georgios Tzimas, Delaney Haugan, Mariama Akodad, Janarthanan Sathananthan, David Meier, Salah Dine Qanadli, John G. Webb, Philipp Blanke


  • Open Access

    Performance of Computed Tomography Angiography (CTA) for the Diagnosis of Hypo-Attenuated Leaflet Thickening (HALT)

    by Manuel Hein, Philipp Breitbart, Jan Minners, Philipp Blanke, Simon Schoechlin, Christopher Schlett, Tobias Krauss, Martin Soschynski, Franz-Josef Neumann, Philipp Ruile

    (1) Background: Early hypo-attenuated leaflet thickening (HALT) is diagnosed by computed tomography angiography (CTA) in approximately 15% of patients undergoing transcatheter aortic valve replacement (TAVR). We sought to investigate the diagnostic performance of CTA for the diagnosis of HALT, focusing on timing data assessment within the cardiac cycle. (2) Methods: The study enrolled 50 patients with and 50 without HALT with available post-TAVR-CTA. The primary objective was to compare the diagnostic performance of CTA readings at specific intervals and time points during the cardiac cycle (entire systole, entire diastole, end-systole, and mid-diastole) versus gold standard (consensus reading by two observers based on multiphase full cardiac cycle data sets). (3) Results: 100 CTAs were independently analysed by two observers blinded to clinical characteristics of the study population and the results from the gold standard reading. Sensitivity and specificity for the diagnosis of HALT were 84%/94% in systole, 87%/92% in diastole, 78%/95% at end-systole, and 80%/94% at mid-diastole. End-systole had the highest positive predictive value (0.88) and positive likelihood ratio (36). Cohen’s kappa for interobserver reliability was 0.715 in systole, 0.578 in diastole, 0.650 at end-systole, and 0.517 at mid-diastole. (4) Conclusion: Limiting CTA reading to distinct intervals or time points during the cardiac cycle has good specificity but lowers sensitivity. For a reliable diagnosis of HALT, data sets from a multiphase CTA covering the entire cardiac cycle should be analysed. A double reader approach would be desirable in further studies investigating HALT.