Adel Pourmand
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Adel Pourmand has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Amir Kiyoumarsioskouei
Faculty of Mechanical Engineering, Sahand University of Technology, Tabriz, Iran
2 shared publications Ali Mirvakili
Department of Electrical Engineering Yazd University Yazd Iran
1 shared publication- Asal Alimohammadi
Faculty of Electrical Engineering, Sahand University of Technology, Sahand New Town, Tabriz, Iran
1 shared publication Asma Molaie
Faculty of Electrical Engineering, Sahand University of Technology, Sahand New Town, Tabriz, Iran
1 shared publicationFarhang Abbasi
Institute for Polymer Materials Sahand University of Technology Tabriz Iran
1 shared publicationHabib Badri Ghavifekr
Faculty of Electrical Engineering Sahand University of Technology Tabriz Iran
1 shared publication
Latest Publications
- 13 November 2025
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (11) , 115007
Plug-and-play 3D-printed modular microchannel heat sinks for efficient microelectronic chip cooling
The increasing thermal loads in modern microelectronic devices necessitate the development of compact and efficient cooling solutions. This study introduces an innovative design and fabrication method for modular microchannel heat sinks that eliminates the need for conductive pastes, utilizing conventional 3D printing technology. Two geometrical configurations, U-turn mini-channels with straight and wavy arm designs, were developed on transparent PMMA substrates, sealed with a 60 μ m TPU membrane to ensure thermal reliability and prevent direct fluid contact with the chip surface. The modular design allows for easy replacement, low-cost production, and adaptability to various thermal scenarios. Thermal and hydraulic performance were experimentally evaluated using water as the working fluid under laminar flow conditions with different volumetric flow rates (200–1000 µ l min −1 ). Key performance metrics included pressure drop, outlet fluid temperature, average Nusselt number, thermal resistance, and performance factor. Results showed that the straight arm design consistently outperformed the wavy arm design in terms of thermal resistance and heat transfer efficiency, with up to a 31% reduction in thermal resistance at higher flow rates. The straight configuration also maintained a higher Nusselt number and performance factor ( η > 1), indicating superior thermo-hydraulic performance. In contrast, the wavy arm design, while enhancing mixing, suffers from higher pressure drops and lower overall efficiency ( η < 1).
- 13 November 2025
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (11) , 115007
Plug-and-play 3D-printed modular microchannel heat sinks for efficient microelectronic chip cooling
The increasing thermal loads in modern microelectronic devices necessitate the development of compact and efficient cooling solutions. This study introduces an innovative design and fabrication method for modular microchannel heat sinks that eliminates the need for conductive pastes, utilizing conventional 3D printing technology. Two geometrical configurations, U-turn mini-channels with straight and wavy arm designs, were developed on transparent PMMA substrates, sealed with a 60 μ m TPU membrane to ensure thermal reliability and prevent direct fluid contact with the chip surface. The modular design allows for easy replacement, low-cost production, and adaptability to various thermal scenarios. Thermal and hydraulic performance were experimentally evaluated using water as the working fluid under laminar flow conditions with different volumetric flow rates (200–1000 µ l min −1 ). Key performance metrics included pressure drop, outlet fluid temperature, average Nusselt number, thermal resistance, and performance factor. Results showed that the straight arm design consistently outperformed the wavy arm design in terms of thermal resistance and heat transfer efficiency, with up to a 31% reduction in thermal resistance at higher flow rates. The straight configuration also maintained a higher Nusselt number and performance factor ( η > 1), indicating superior thermo-hydraulic performance. In contrast, the wavy arm design, while enhancing mixing, suffers from higher pressure drops and lower overall efficiency ( η < 1).
- 9 April 2025
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (4) , 045013
A low-cost 3D-printing based rapid fabrication procedure for modular microfluidic platform
This paper introduces a low-cost, rapid, and simple method for fabricating 3D-printed microfluidic chips, inspired by LEGO® bricks, to accommodate modular microfluidic platforms. A fused filament fabrication (FFF) 3D printer was operated and modified to print a single 400 μm layer of thermoplastic material onto a polymethyl methacrylate substrate, resulting in a very smooth and transparent microchannel by minimizing the limitations of this additive manufacturing. Specific male/female chip-to-world and chip-to-chip connectors have been developed to implement the device’s modularity. In addition, various post-processing procedures were considered because of the inherent surface roughness of the FFF method. Several microfluidic components were designed and fabricated, including T-shaped and cross-shaped microchannels, zig-zag pattern micromixers, and four oval-shaped parallel microchannels. The chips’ validity was examined by injecting food dye into a group of modules to observe the chips’ leakage and fluid circulation behavior. At last, a fluorescent test was implemented to observe the mixing efficiency of the micromixer chip. The proposed fabrication method, from materials’ cost, accessibility, and commercialized perspectives, offers a high throughput process. In other words, it could be fabricated and implemented in most lab environments with limited facilities and budget without expensive equipment. All microfluidic chips in this work have been designed using a modular concept. This relatively new approach allows users to reconfigure connections and microfluidic components to obtain the desired system.
- 9 April 2025
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (4) , 045013
A low-cost 3D-printing based rapid fabrication procedure for modular microfluidic platform
This paper introduces a low-cost, rapid, and simple method for fabricating 3D-printed microfluidic chips, inspired by LEGO® bricks, to accommodate modular microfluidic platforms. A fused filament fabrication (FFF) 3D printer was operated and modified to print a single 400 μm layer of thermoplastic material onto a polymethyl methacrylate substrate, resulting in a very smooth and transparent microchannel by minimizing the limitations of this additive manufacturing. Specific male/female chip-to-world and chip-to-chip connectors have been developed to implement the device’s modularity. In addition, various post-processing procedures were considered because of the inherent surface roughness of the FFF method. Several microfluidic components were designed and fabricated, including T-shaped and cross-shaped microchannels, zig-zag pattern micromixers, and four oval-shaped parallel microchannels. The chips’ validity was examined by injecting food dye into a group of modules to observe the chips’ leakage and fluid circulation behavior. At last, a fluorescent test was implemented to observe the mixing efficiency of the micromixer chip. The proposed fabrication method, from materials’ cost, accessibility, and commercialized perspectives, offers a high throughput process. In other words, it could be fabricated and implemented in most lab environments with limited facilities and budget without expensive equipment. All microfluidic chips in this work have been designed using a modular concept. This relatively new approach allows users to reconfigure connections and microfluidic components to obtain the desired system.
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 19 (1)
A Low‐Cost Paper‐Based Microfluidic POCT Device for In Vitro Glucose Sensing Using Near‐Infrared Detection
This study presents a low‐cost Near Infrared (NIR)‐based optical microfluidic POCT device for in vitro glucose detection on a paper‐based microfluidic platform. The device is made using a UV‐curable resin that has been widely used in the publishing industry, which is proposed as a low‐cost alternative to the expensive SU‐8 photoresist normally used in photolithography. A 940 nm NIR LED–photodiode system was incorporated to non‐invasively measure glucose levels. Glucose concentrations ranging from 62.5 to 1000 mg/dL were tested using only 3 µL of sample. To evaluate the effect of light intensity, three different LED currents (0.5, 0.75 and 1 mA) were applied. Output voltage ranged from approximately 570 to 700 mV and decreased with increasing glucose concentration, following Beer‐Lambert's law. Regression models yielded R 2 values above 97%, confirming the device's accuracy and its potential for real‐time, disposable, paper‐based microfluidic glucose monitoring in point‐of‐care settings.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 19 (1)
Open AccessA Low‐Cost Paper‐Based Microfluidic POCT Device for In Vitro Glucose Sensing Using Near‐Infrared Detection
This study presents a low‐cost Near Infrared (NIR)‐based optical microfluidic POCT device for in vitro glucose detection on a paper‐based microfluidic platform. The device is made using a UV‐curable resin that has been widely used in the publishing industry, which is proposed as a low‐cost alternative to the expensive SU‐8 photoresist normally used in photolithography. A 940 nm NIR LED–photodiode system was incorporated to non‐invasively measure glucose levels. Glucose concentrations ranging from 62.5 to 1000 mg/dL were tested using only 3 µL of sample. To evaluate the effect of light intensity, three different LED currents (0.5, 0.75 and 1 mA) were applied. Output voltage ranged from approximately 570 to 700 mV and decreased with increasing glucose concentration, following Beer‐Lambert's law. Regression models yielded R 2 values above 97%, confirming the device's accuracy and its potential for real‐time, disposable, paper‐based microfluidic glucose monitoring in point‐of‐care settings.
- 17 January 2024
- Published by Wiley in ETRI Journal
- Vol. 46 (4) , 581-594
Design and simulation of a rectangular planar printed circuit board coil for nuclear magnetic resonance, radio frequency energy harvesting, and wireless power transfer devices
In this study, a planar printed circuit board (PCB) coil with FR4 substrate was designed and simulated using the finite element method, and the results were analyzed in the frequency domain. This coil can be used in wireless power transfer (WPT) as a transmitter or receiver, eliminating wires. It can also be used as the receiver in radio frequency energy‐harvesting (RF‐EH) systems by optimizing the planar PCB coil to convert radio‐wave energy into electricity, and it can be employed as an excitation (transmitter) or receiver coil in nuclear magnetic resonance (NMR) spectroscopy. This PCB coil can replace the conventional coil, yielding a reduced occupied volume, a fine‐tuned design, reduced weight, and increased efficiency. Based on the calculated gain, power, and electromagnetic and electric field results, this planar PCB coil can be implemented in WPT, NMR spectroscopy, and RF‐EH devices with minor changes. In applications such as NMR spectroscopy, it can be used as a transceiver planar PCB coil. In this design, at frequencies of 915 MHz and 40 MHz with 5 mm between coils, we received powers of 287.3 W and 480 W, respectively, which are suitable for an NMR coil or RF‐EH system.
- 17 January 2024
- Published by Wiley in ETRI Journal
- Vol. 46 (4) , 581-594
Design and simulation of a rectangular planar printed circuit board coil for nuclear magnetic resonance, radio frequency energy harvesting, and wireless power transfer devices
In this study, a planar printed circuit board (PCB) coil with FR4 substrate was designed and simulated using the finite element method, and the results were analyzed in the frequency domain. This coil can be used in wireless power transfer (WPT) as a transmitter or receiver, eliminating wires. It can also be used as the receiver in radio frequency energy‐harvesting (RF‐EH) systems by optimizing the planar PCB coil to convert radio‐wave energy into electricity, and it can be employed as an excitation (transmitter) or receiver coil in nuclear magnetic resonance (NMR) spectroscopy. This PCB coil can replace the conventional coil, yielding a reduced occupied volume, a fine‐tuned design, reduced weight, and increased efficiency. Based on the calculated gain, power, and electromagnetic and electric field results, this planar PCB coil can be implemented in WPT, NMR spectroscopy, and RF‐EH devices with minor changes. In applications such as NMR spectroscopy, it can be used as a transceiver planar PCB coil. In this design, at frequencies of 915 MHz and 40 MHz with 5 mm between coils, we received powers of 287.3 W and 480 W, respectively, which are suitable for an NMR coil or RF‐EH system.
- 26 December 2015
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (5) , 1351-1360
Design and simulation of a MEMS based cell separator utilizing 3D travelling-wave dielectrophoresis
- 26 December 2015
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (5) , 1351-1360
Design and simulation of a MEMS based cell separator utilizing 3D travelling-wave dielectrophoresis