Mona M. Naim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mona M. Naim has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Mahmoud M. Elewa
Arab Academy for Science, Technology and Maritime Transport, Alexandria P.O. Box 1029, Egypt
5 shared publications - Ahmed El-Shafei
Department of Agricultural Engineering, College of Food and Agriculture Sciences, King Saud University, Riyadh 11451, Saudi Arabia
3 shared publications - Abeer A. Moneer
Marine Pollution Department, Marine Environmental Division, National Institute of Oceanography and Fisheries, Alexandria, Egypt
2 shared publications - Mervette El Batouti
Chemistry Department, Faculty of Science, Alexandria University, Alexandria, Egypt
2 shared publications - Nouf F. Al Harby
Department of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia
2 shared publications A. A. Moneer
National Institute of Oceanography and Fisheries, Alexandria, Egypt
1 shared publication
Latest Publications
- Open Access
An Investigation into a Miniature Saltless Solar Pond
A simple, miniature saltless Solar Pond (SP) was designed and constructed in the present work. It consisted of a Plexiglas container with a square cross-section, within which cruciform baffles were suspended in the upper half of the pond, and copper coil tubing was fitted in the middle of the lower zone to function as a heat exchanger without disturbing the pond’s inertia. Different variables’ effect on the water’s temperature rise at various vertical locations within the pond were investigated. These variables included the presence of the cruciform baffles, the inclination of a mirror fixed to the top rim of the pond, a glass transparent cover (GC), and the presence or absence of a gel thickening material to increase the water viscosity inside the SP, the climatic conditions, and the presence of glass wool (GW) in the lower section of the SP. For an experiment, an estimated energy balance was performed, and the thermal storage efficiency was calculated. The best obtained thermal storage efficiency was 32.58% in the presence of the cruciform baffles, a 45° inclination of a mirror fixed to the top rim of the SP, at an ambient temperature of 30 °C on a calm, sunny day with a wind speed of 7 km/h.
Open AccessAn Investigation into a Miniature Saltless Solar Pond
A simple, miniature saltless Solar Pond (SP) was designed and constructed in the present work. It consisted of a Plexiglas container with a square cross-section, within which cruciform baffles were suspended in the upper half of the pond, and copper coil tubing was fitted in the middle of the lower zone to function as a heat exchanger without disturbing the pond’s inertia. Different variables’ effect on the water’s temperature rise at various vertical locations within the pond were investigated. These variables included the presence of the cruciform baffles, the inclination of a mirror fixed to the top rim of the pond, a glass transparent cover (GC), and the presence or absence of a gel thickening material to increase the water viscosity inside the SP, the climatic conditions, and the presence of glass wool (GW) in the lower section of the SP. For an experiment, an estimated energy balance was performed, and the thermal storage efficiency was calculated. The best obtained thermal storage efficiency was 32.58% in the presence of the cruciform baffles, a 45° inclination of a mirror fixed to the top rim of the SP, at an ambient temperature of 30 °C on a calm, sunny day with a wind speed of 7 km/h.
- Open Access
Macro-Reticular Ion Exchange Resins for Recovery of Direct Dyes from Spent Dyeing and Soaping Liquors
Dyes are a major class of organic pollutants that are well-known for their harmful impact on aquatic life and humans. Several new strategies for removing colours from industrial and residential effluents have recently emerged, with adsorption being the best option. The current study looked at the recovery of direct dyes from aqueous streams for reuse using macro-reticular ion exchange resins (IERs). The investigation includes dyeing single jersey cotton grey textiles with direct dyes from the Isma dye Company in Kafr El Dawar, Egypt. After centrifuging and separating the supernatant liquid, solutions from thirteen different dyes, produced at an average concentration between the wasted and soaping liquor concentrations, were calculated spectrophotometrically from the first dyeing trials. Kinetic data were well fitted with pseudo-second-order rate kinetics. The amounts of dye retained by the anion exchangers increased with a rise in temperature in the case of Strong Base Resin (SBR) and vice versa for Weak Base Resin (WBR). Batch adsorption experiments with SBR and WBR were conducted for each dye, and both Freundlich and Langmuir isotherms were constructed. It was found that adsorption obeyed both isotherms, that monolayer adsorption took place, and that the dye molecular weight, structure, and solubility, as well as the type of anionic resin used, had varying effects on the extent of absorption. The monolayer sorption capacities Q0 determined from the Langmuir isotherm model for the strongly and weakly basic anion exchangers were found to be 537.6 and 692 mg/g for Direct Yellow RL, respectively. As a result, Yellow RL exhibited the greatest adsorption on both SBR and WBR. Orange GRLL, Blue 3B, and Congo Red, on the other hand, were the poorest colours absorbed by the IERs, whereas Blue RL demonstrated good adsorption by SBR and accelerated adsorption by WBR. Most of the dyes may be recovered and reused in this manner.
Open AccessMacro-Reticular Ion Exchange Resins for Recovery of Direct Dyes from Spent Dyeing and Soaping Liquors
Dyes are a major class of organic pollutants that are well-known for their harmful impact on aquatic life and humans. Several new strategies for removing colours from industrial and residential effluents have recently emerged, with adsorption being the best option. The current study looked at the recovery of direct dyes from aqueous streams for reuse using macro-reticular ion exchange resins (IERs). The investigation includes dyeing single jersey cotton grey textiles with direct dyes from the Isma dye Company in Kafr El Dawar, Egypt. After centrifuging and separating the supernatant liquid, solutions from thirteen different dyes, produced at an average concentration between the wasted and soaping liquor concentrations, were calculated spectrophotometrically from the first dyeing trials. Kinetic data were well fitted with pseudo-second-order rate kinetics. The amounts of dye retained by the anion exchangers increased with a rise in temperature in the case of Strong Base Resin (SBR) and vice versa for Weak Base Resin (WBR). Batch adsorption experiments with SBR and WBR were conducted for each dye, and both Freundlich and Langmuir isotherms were constructed. It was found that adsorption obeyed both isotherms, that monolayer adsorption took place, and that the dye molecular weight, structure, and solubility, as well as the type of anionic resin used, had varying effects on the extent of absorption. The monolayer sorption capacities Q0 determined from the Langmuir isotherm model for the strongly and weakly basic anion exchangers were found to be 537.6 and 692 mg/g for Direct Yellow RL, respectively. As a result, Yellow RL exhibited the greatest adsorption on both SBR and WBR. Orange GRLL, Blue 3B, and Congo Red, on the other hand, were the poorest colours absorbed by the IERs, whereas Blue RL demonstrated good adsorption by SBR and accelerated adsorption by WBR. Most of the dyes may be recovered and reused in this manner.
- Open Access
- 1 October 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (48-49) , 22824-22834
Removal of copper from simulated wastewater by electrocoagulation/floatation technique
Many industries, such as tanning, metal processing, electroplating, etc., include copper in their processes and discharge it in wastewater streams. The permissible limit of copper in wastewater is 1.3 mg/L, accordingly, industries must lower their copper limits to meet their local legal guidelines. This can be done by numerous methods including chemical precipitation, oxidation–reduction, ion exchange, etc. Electrocoagulation (EC)/floatation (ECF) technique, however, is an effective, cheap and simple electrochemical method for treating wastewater containing copper (Cu(II)) ions, which involves generation of coagulants using sacrificial electrodes when a DC voltage is applied; simultaneously generating hydrogen gas at the cathode which can help in the floatation of the formed particles. In the present work, a specially devised and innovated bench-scale EC apparatus was constructed and used in the removal of Cu(II) ions from aqueous solution. Numerous factors were investigated for their effect on the efficiency of removal of Cu(II) ions and those were: initial Cu(II) ion solution concentration, speed of magnetic stirring in the EC cell, number and type of sacrificial electrodes (aluminium (Al) or iron (Fe) electrodes), mixed electrodes, aspect ratio of the EC cell and the addition of a supporting electrolyte. It was found that lower initial concentrations required the minimum time to effect 100% removal of the Cu(II) ions, and that there existed an optimum speed of magnetic stirring in the EC cell, it was found that when C0 was 3 g/L it took only 25 min for complete removal of Cu(II) ions at 300 rpm, whereas, when C0 was 10 g/L it required 45 min at 120 rpm for complete removal, while at medium C0 (6.5 g/L) 30 min were needed to effect 100% removal at 240 rpm, and that Fe electrodes were more efficient in removing Cu(II) ions than Al. Regarding the floatation chamber (FC), it resulted in the production of totally clean water at its outlet and decreased the time required for complete Cu(II) removal to one third its value without FC which proved its importance in effecting good separation.
- 1 October 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (48-49) , 22824-22834
Open AccessRemoval of copper from simulated wastewater by electrocoagulation/floatation technique
Many industries, such as tanning, metal processing, electroplating, etc., include copper in their processes and discharge it in wastewater streams. The permissible limit of copper in wastewater is 1.3 mg/L, accordingly, industries must lower their copper limits to meet their local legal guidelines. This can be done by numerous methods including chemical precipitation, oxidation–reduction, ion exchange, etc. Electrocoagulation (EC)/floatation (ECF) technique, however, is an effective, cheap and simple electrochemical method for treating wastewater containing copper (Cu(II)) ions, which involves generation of coagulants using sacrificial electrodes when a DC voltage is applied; simultaneously generating hydrogen gas at the cathode which can help in the floatation of the formed particles. In the present work, a specially devised and innovated bench-scale EC apparatus was constructed and used in the removal of Cu(II) ions from aqueous solution. Numerous factors were investigated for their effect on the efficiency of removal of Cu(II) ions and those were: initial Cu(II) ion solution concentration, speed of magnetic stirring in the EC cell, number and type of sacrificial electrodes (aluminium (Al) or iron (Fe) electrodes), mixed electrodes, aspect ratio of the EC cell and the addition of a supporting electrolyte. It was found that lower initial concentrations required the minimum time to effect 100% removal of the Cu(II) ions, and that there existed an optimum speed of magnetic stirring in the EC cell, it was found that when C0 was 3 g/L it took only 25 min for complete removal of Cu(II) ions at 300 rpm, whereas, when C0 was 10 g/L it required 45 min at 120 rpm for complete removal, while at medium C0 (6.5 g/L) 30 min were needed to effect 100% removal at 240 rpm, and that Fe electrodes were more efficient in removing Cu(II) ions than Al. Regarding the floatation chamber (FC), it resulted in the production of totally clean water at its outlet and decreased the time required for complete Cu(II) removal to one third its value without FC which proved its importance in effecting good separation.
- Open Access
- 5 January 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (48-49) , 23280-23292
Kinetics of transport of sodium chloride using supported liquid pertraction
In the present work, the removal of NaCl using the present type of supported liquid membrane technique has been investigated. A simple apparatus devised and constructed was used to conduct the experiments. Various factors that would affect the progress of transport were studied and these were initial concentration (Ci) of simulated seawater in donor phase (DP), presence of mobile carrier (MC) in the liquid membrane (LM), concentration of MC in LM, presence of sequestering agent (SA) in the receptor phase (RP), and speed of stirring. The volume ratio of DP to RP was kept constant at 2:1. Type (1,2 dichloroethane (DCE)) and thickness (2 mm) of LM were kept constant. Cellophane constituted the support for the LM. The most important findings emphasized the importance of the presence of a MC in the LM to enhance mass transfer through the LM and that an optimum concentration of MC existed. Also the importance of stirring in promoting mass transfer by minimizing the boundary layer intact to the cellophane support was elucidated. The best conditions arrived at were MC = 0.0538 mol/l (mol of dibenzo-18-crown-6/l of LM), SA = 0.0617 mol/l (mol of soluble starch/l of RP), slow stirring (100 rpm) of DP, and using DCE as LM. The mass transfer of NaCl was analyzed based on kinetic laws of two consecutive irreversible first-order reactions, and kinetic parameters (k1d, k2m, k2r, , tmax, , ) for the transport of NaCl were investigated. The values obtained demonstrate that the process is diffusion-controlled. Results indicate that the membrane entrance and exit rate constants (k1, k2) increase directly with Ci and inversely with quantity of SA.
- 5 January 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (48-49) , 23280-23292
Open AccessKinetics of transport of sodium chloride using supported liquid pertraction
In the present work, the removal of NaCl using the present type of supported liquid membrane technique has been investigated. A simple apparatus devised and constructed was used to conduct the experiments. Various factors that would affect the progress of transport were studied and these were initial concentration (Ci) of simulated seawater in donor phase (DP), presence of mobile carrier (MC) in the liquid membrane (LM), concentration of MC in LM, presence of sequestering agent (SA) in the receptor phase (RP), and speed of stirring. The volume ratio of DP to RP was kept constant at 2:1. Type (1,2 dichloroethane (DCE)) and thickness (2 mm) of LM were kept constant. Cellophane constituted the support for the LM. The most important findings emphasized the importance of the presence of a MC in the LM to enhance mass transfer through the LM and that an optimum concentration of MC existed. Also the importance of stirring in promoting mass transfer by minimizing the boundary layer intact to the cellophane support was elucidated. The best conditions arrived at were MC = 0.0538 mol/l (mol of dibenzo-18-crown-6/l of LM), SA = 0.0617 mol/l (mol of soluble starch/l of RP), slow stirring (100 rpm) of DP, and using DCE as LM. The mass transfer of NaCl was analyzed based on kinetic laws of two consecutive irreversible first-order reactions, and kinetic parameters (k1d, k2m, k2r, , tmax, , ) for the transport of NaCl were investigated. The values obtained demonstrate that the process is diffusion-controlled. Results indicate that the membrane entrance and exit rate constants (k1, k2) increase directly with Ci and inversely with quantity of SA.
- 1 June 2015
- Published by IWA Publishing in Water Practice & Technology
- Vol. 10 (2) , 337-346
Ultrafiltration by a super-hydrophilic regenerated cellulose membrane
- 1 June 2015
- Published by IWA Publishing in Water Practice & Technology
- Vol. 10 (2) , 337-346
Ultrafiltration by a super-hydrophilic regenerated cellulose membrane