AMAbeer A. Moneer

Abeer A. Moneer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abeer A. Moneer has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Marine algae-mediated PVDF/ZnO nanocomposite ultrafiltration membranes: superior performance in Cr(VI) removal from aqueous solutions

    by Mohamed Khedawy, Abeer A. Moneer, Azza M. Shaker, Mohamed S. Ramadan, Eman A. Fadl

    Nano-membrane technology continues to expand its role in water purification. However, this technological advancement faces significant challenges, such as potential toxicity issues and membrane fouling, necessitating the development of sustainable and environmentally benign filtration solutions. In the present study, zinc oxide nanoparticles (ZnO NPs) derived from blue-green algae Arthrospira platensis were used in fabrication of polyvinylidene fluoride (PVDF) ultrafiltration (UF) nanocomposite membranes for the removal of Chromium (VI). This approach ensures environmental compatibility while minimizing ecotoxicological concerns often associated with conventionally synthesized materials. The membrane fabrication process employed the phase inversion technique, with subsequent comprehensive characterization utilizing X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), energy-dispersive X-ray analysis (EDX), and water contact angle (WCA) measurements to thoroughly assess their physicochemical properties and structural morphology. The functional performance of these membranes was evaluated through water flux measurements and Chromium (VI) removal efficiency tests. Various concentrations of biosynthesized ZnO nanoparticles (0.5, 1, 2, and 3 wt%) were systematically incorporated into the PVDF matrix, with experimental results demonstrating that the optimized membrane containing 3 wt% ZnO NPs exhibited exceptional performance characteristics, achieving 91.69% removal efficiency for Chromium (VI), an adsorption capacity (qe) of 10.92 µg/cm2, and superior hydrophilicity with a significantly reduced contact angle of 48.9°. Additionally, the water permeability of this optimized nanocomposite membrane demonstrated a substantial 50% enhancement compared to the neat PVDF membrane. Kinetic analyses indicated that the adsorption process followed a pseudo-second-order model, while isotherm studies revealed that the Langmuir model provided the most accurate representation of the adsorption mechanism, suggesting monolayer coverage on homogeneous surface sites. This research not only introduces an environmentally responsible approach to nanocomposite membrane synthesis but also demonstrates the exceptional efficacy of these membranes in heavy metal remediation, offering a sustainable and economically viable solution for industrial wastewater treatment with considerable potential for practical environmental applications and technological scale-up. Graphical Abstract


  • Open Access

    Electrocoagulation process for oily wastewater treatment and optimization using response surface methodology

    by A. A. Moneer, W. M. Thabet, M. Khedawy, M. M. El-Sadaawy, N. A. Shaaban

    Electrocoagulation technique using aluminum electrodes in a batch bi-polar system was investigated to determine the efficiency of removing oil from oily wastewater. The Box–Behnken design was utilized to optimize conditions and the effects of four independent factors, including oil volume (X1), temperature (X2), initial pH (X3), and treatment time (X4),—were examined to investigate turbidity recovery and conductivity changes. The significant independent variables and their interactions were assessed using ANOVA. The optimal operating conditions for turbidity removal were obtained at an oil volume of 10 ml L−1, a temperature of 28 °C, an initial pH of 4, and a coagulation time of 90 min. The results revealed that turbidity removal and conductivity changes are enhanced significantly with increasing treatment time and decreasing oil volume. The application of the treatment process under optimal operating conditions allows promising removal efficiencies of 97.3%, and 73.4% for turbidity and conductivity, respectively. Also, the treated wastewater showed remarkable changes in removal efficiencies of the main oily wastewater pollution loads for COD, NO2, PO4, DO, and BOD. The economic study indicated that oily wastewater treatment by electrocoagulation is a very cost-effective technique.


  • Spatiotemporal distribution of some dissolved salts and minerals in Lake Edku connected to Mediterranean Sea: in relation to different pollutant inputs

    by Ghada F. El-Said, Manal M. El-Sadaawy, Nayrah A. Shaltout, Abeer A. Moneer

    Regarding the generally accepted view of the minerals formed in solving the problem of ecosystem pollution, this research aims to track the role of seasonal minerals in overcoming widespread pollution problems in Lake Edku. At eleven locations inside Lake Edku and three locations in the outside the water inlets, some physical and chemical parameters that affect the formation of minerals and salts were detected seasonally. As a result of human activities from 1972 to 2020, the applied remote sensing technology showed a decrease in the area of Edku Lake by 13.3%. The saturation index (SI) of twelve minerals formed in fifty-six seasonal water samples collected from fourteen locations inside and outside the lake was estimated. The saturation index (SI) of anhydrite (ANH), gypsum (GYP), calcium phosphate (CP), magnesium phosphate (MP), calcite (CAL), aragonite (ARG), dolomite (DOL), magnesite (MGS), fluorapatite (FAP), hydroxyapatite (HAP), octacalcium phosphate (OCP), and carbonate-fluorapatite (CFAP) was calculated. The presented SI values of apatite and phosphate minerals including FAP (SI 30.63–65.65), CFAP (SI 28.14–40.02), HAP (SI 24.83–31.81), Ca3(PO4)2 (SI 23.99–25.95), OCP (SI 19.96–25.47), and Mg3(PO4)2 (SI 15.80–17.46) were high. Palmer-Roger’s diagram and piper ternary diagram models reflected the abundance of NaCl in lake water with 30, 40, 46, and 75% in winter, spring, summer, and autumn, respectively. Using correlation matrix, multiple stepwise regression and cluster analysis for statistical analysis, the relationship between sedimentary minerals and outflow and drainage, as well as the role of sedimentary minerals in reducing pollution in the lake area, was outlined.


  • Desalination using modified configuration of supported liquid membrane with enhancement of mass transfer of NaCl

    by Mona M. Naim, Abeer A. Moneer, Mahmoud M. Elewa, Ahmed A. El-Shafei

    Supported liquid membranes (SLM) suffers from very slow mass transfer of the solute from donor phase (DP) to receptor phase (RP) through liquid membrane (LM). In the present work an attempt was done to accelerate the mass transfer in SLM by creating a modified configuration in which the DP and RP are made to flow either co- or counter-currently to each other. Variables, which could affect the removal of NaCl, were volume ratio of DP to RP, type and quantity of sequestering agent (SA), presence of mobile carrier (MC), type of LM, flow rate of DP and RP. The results showed the higher the flow rate of DP and RP, the higher the mass transfer of NaCl. Quantity and type of SA and type of LM were prime important factors. Remarkably, the time required for transfer of NaCl from DP to RP was reduced from several hours in case of stagnant SLM to several minutes in the present work. The mass transfer of NaCl was analysed based on kinetic laws of two consecutive irreversible first-order reactions. The values achieved establish the process is diffusion-controlled, and the membrane entrance rate constants increase directly with initial concentration (Ci) and inversely with quantity of SA.


  • Open Access

    Removal of copper from simulated wastewater by electrocoagulation/floatation technique

    by Abeer A. Moneer, Ahmed A. El-Shafei, Mahmoud M. Elewa, Mona M. Naim

    Many industries, such as tanning, metal processing, electroplating, etc., include copper in their processes and discharge it in wastewater streams. The permissible limit of copper in wastewater is 1.3 mg/L, accordingly, industries must lower their copper limits to meet their local legal guidelines. This can be done by numerous methods including chemical precipitation, oxidation–reduction, ion exchange, etc. Electrocoagulation (EC)/floatation (ECF) technique, however, is an effective, cheap and simple electrochemical method for treating wastewater containing copper (Cu(II)) ions, which involves generation of coagulants using sacrificial electrodes when a DC voltage is applied; simultaneously generating hydrogen gas at the cathode which can help in the floatation of the formed particles. In the present work, a specially devised and innovated bench-scale EC apparatus was constructed and used in the removal of Cu(II) ions from aqueous solution. Numerous factors were investigated for their effect on the efficiency of removal of Cu(II) ions and those were: initial Cu(II) ion solution concentration, speed of magnetic stirring in the EC cell, number and type of sacrificial electrodes (aluminium (Al) or iron (Fe) electrodes), mixed electrodes, aspect ratio of the EC cell and the addition of a supporting electrolyte. It was found that lower initial concentrations required the minimum time to effect 100% removal of the Cu(II) ions, and that there existed an optimum speed of magnetic stirring in the EC cell, it was found that when C0 was 3 g/L it took only 25 min for complete removal of Cu(II) ions at 300 rpm, whereas, when C0 was 10 g/L it required 45 min at 120 rpm for complete removal, while at medium C0 (6.5 g/L) 30 min were needed to effect 100% removal at 240 rpm, and that Fe electrodes were more efficient in removing Cu(II) ions than Al. Regarding the floatation chamber (FC), it resulted in the production of totally clean water at its outlet and decreased the time required for complete Cu(II) removal to one third its value without FC which proved its importance in effecting good separation.


  • Open Access

    Effect of cell hydrodynamics in desalination of saline water by sweeping air pervaporation technique using innovated membrane

    by Mahmoud M. Elewa, Ahmed A. El-Shafei, Abeer A. Moneer, Mona M. Naim

    Scarcity of potable water nowadays, presents a serious problem all over the world. Environmental changes are taking place at a rapid pace, resulting in greenhouse effects, desertification, and lack of fresh water. Accordingly, scientists are working hard toward inventing new techniques for desalinating sea water, which presents the only alternative solution to this problem. In this regard, desalination techniques are mainly divided into thermal and membrane techniques. However, the latter are superior in that they are modular in shape, and consume less energy. In the present work, desalination by a novel recent membrane separation technique, the so-called sweeping air pervaporation (PV), which has been very sparsely applied to desalination of sea water, has been conducted in our laboratory. The technique is simple, straightforward, cost-effective and does not suffer from limitations as regards low water recovery, such as reverse osmosis. An innovated deacetylated cellulose acetate (CA) membrane was prepared by the phase inversion technique, from a specially formulated casting solution mixture composed of CA, acetone (A), dioxane (D), dimethyl formamide, dimethyl phthalate, and maleic anhydride in definite proportions, and used in all the experiments. Two PV cells of different configuration and aspect ratio (AR) were designed and constructed, in order to investigate the effect of hydrodynamics on membrane performance. Numerous variables were studied for their effect on the pervaporate flux (J) and % salt rejection (%SR), and these were: initial salt solution concentration (Ci), PV temperature (Tpv), and PV cell configuration. It was found that the flux obtained was directly proportional to Tpv, and that the J was almost independent of Ci at low Tpvs, except in the case of Tpv = 80°C for both small and large configurations, where J was inversely proportional to Ci (in the range 15–120 g/l), and that higher fluxes were obtained under the same conditions in case of the PV cell of higher AR. The activation energy (Ea) for permeation through the membrane in both the cells was computed from the Arrhenius equation, and was found to be 20.89–23.06 kJ/mol K at Ci = 120 g/l, for the cell with higher and lower AR, respectively, denoting facile permeation of water through the membrane, for the two cell designs, in particular with higher AR. The results indicate that at all concentrations tested for large cell below 70°C, the product, after a once-through operation, was exceptional potable water with very low salinity (%SR 98.9) even when Ci was 120.8 g/l, and maximum flux obtained was 5 l/m2 h at Tpv = 70°C. The separation factor (α), PV separation index (PSI), overall mass transfer coefficient (Kov), diffusion coefficient (Di), salt diffusivity (Ds), and salt permeability (P), through the membrane were all calculated and their values are stated inside the paper text. Nevertheless, α varied between 5.6 and 853.4, and PSI reached 3494.5 l/m2 h.


  • Open Access

    Kinetics of transport of sodium chloride using supported liquid pertraction

    by Ahmed A. El-Shafei, Abeer A. Moneer, Mahmoud M. Elewa, Mona M. Naim

    In the present work, the removal of NaCl using the present type of supported liquid membrane technique has been investigated. A simple apparatus devised and constructed was used to conduct the experiments. Various factors that would affect the progress of transport were studied and these were initial concentration (Ci) of simulated seawater in donor phase (DP), presence of mobile carrier (MC) in the liquid membrane (LM), concentration of MC in LM, presence of sequestering agent (SA) in the receptor phase (RP), and speed of stirring. The volume ratio of DP to RP was kept constant at 2:1. Type (1,2 dichloroethane (DCE)) and thickness (2 mm) of LM were kept constant. Cellophane constituted the support for the LM. The most important findings emphasized the importance of the presence of a MC in the LM to enhance mass transfer through the LM and that an optimum concentration of MC existed. Also the importance of stirring in promoting mass transfer by minimizing the boundary layer intact to the cellophane support was elucidated. The best conditions arrived at were MC = 0.0538 mol/l (mol of dibenzo-18-crown-6/l of LM), SA = 0.0617 mol/l (mol of soluble starch/l of RP), slow stirring (100 rpm) of DP, and using DCE as LM. The mass transfer of NaCl was analyzed based on kinetic laws of two consecutive irreversible first-order reactions, and kinetic parameters (k1d, k2m, k2r, , tmax, , ) for the transport of NaCl were investigated. The values obtained demonstrate that the process is diffusion-controlled. Results indicate that the membrane entrance and exit rate constants (k1, k2) increase directly with Ci and inversely with quantity of SA.


  • Open Access

    The precipitation of fluoride, calcium and magnesium minerals from Egyptian Mediterranean Sea coast in relation to discharged waters

    by Ghada F. El-Said, Nayrah A. Shaltout, Abeer A. Moneer, Manal M. El-Sadaawy, Amal M.H. Morsy

    The present study focuses on the effect of discharged wastes on the precipitation of some minerals (calcite, aragonite, dolomite, fluorite and sellaïte) as well as the chemical composition of seawater water columns along the eastern Egyptian Mediterranean Sea coast. This coast is subjected to different discharge waters containing agricultural, industrial, sewage and domestic wastes coming from the Nile River, the North Lakes as well as other different outlets. Variable levels of physicochemical parameters including temperature (T; 15.34–23.12°C), salinity (38.50–40.33%), pH (8.05–8.31), bicarbonate (HCO3; 63.73–147.22 mg/l), carbonate (CO3; 10.01–23.34 mg/l), calcium (Ca; 263.68–791.05 mg/l), magnesium (Mg; 799.67–2452.32 mg/l) and fluoride (F; 0.56–4.76 mg/l) were measured. Amongst the mineral production values that were calculated by saturation index (SI), fluorite and sellaïte calculations almost showed values <1, especially in the Rosetta and Damietta sectors which are affected by the Nile River. Marine organisms were influenced by the change in the physicochemical parameters along the investigated coastal area and showed aragonite and high-Mg calcite formation. Obviously, the statistical analyses of correlation matrix, ANOVA: two-factor without replication and stepwise regression of the present data explored the effect of the discharged effluents on the minerals formation and the chemical composition of seawater along the studied area. Additionally, the results showed the possible public health hazard from marine organism’s ingestion and seawater contact along the polluted areas. Accordingly, it seems advisable to reduce the pollution by discharged wastes into the Egyptian coastal ecosystems.


  • Bulk liquid pertraction of NaCl from aqueous solution using carrier-mediated transport

    by M.M. Naim, A.A. El-Shafei, A.A. Moneer, M.M. Elewa, W.G. Kandeel

    In the present work, removal of NaCl using the bulk liquid membrane (BLM) technique has been investigated, using a simple apparatus for conducting the experiments. Variables investigated were volume ratio of donor phase (DP) to receptor phase (RP), presence of sequestering agent (SA) in RP, type of organic liquid membrane (LM), quantity of mobile carrier (MC) in the LM. Stirring speed and volume of LM were kept constant at 100 rpm and 130 ml, respectively. The mass transfer of NaCl was analysed based on kinetic laws of two consecutive irreversible first-order reactions, and kinetic parameters (k1d, k2m, k2r, , tmax, , and ) for the transport of NaCl were investigated. The values obtained demonstrate that the process is diffusionally controlled. Results indicate that the membrane entrance and exit rate constants (k1, k2) increase with decreasing DP:RP ratio and with decrease in quantity of MC, and quantity of SA, and the presence of dichloroethane (DCE) is preferred to chloroform (CF) as LM.