Vesna Arnautovski-Toseva
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vesna Arnautovski-Toseva has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Blagoja Markovski
Faculty of Electrical Engineering and Information Technologies, Ss. Cyril and Methodius University in Skopje, Skopje, Macedonia
4 shared publications Leonid Grcev
University SS Cyril and Methodius University, Faculty of Electrical Engineering and Information Technologies, Skopje, Macedonia
4 shared publications- Leonid Grcev
Macedonian Academy of Sciences and Arts, Skopje, Macedonia
4 shared publications - Andrijana Kuhar
Institute of Electronics, Faculty of Electrical Engineering and Information Technologies, “Ss. Cyril and Methodius” University in Skopje, 1000 Skopje, North Macedonia
2 shared publications El Drissi
Lasmea, University Blaise Pascal, Aubière, Clermont-Ferrand, France
1 shared publication- Khamlichi Drissi Khalil El
University Blaise Pascal, LASMEA, Aubière, France
1 shared publication
Latest Publications
- 10 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 598-606
Fast and Accurate Transient Analysis of Large Grounding Systems in Multilayer Soil
One of the most accurate approaches to the lightning-related transient analysis of grounding systems in layered soil is based on the method of moments solution of the integral form of Maxwell equations. The practical application of this rigorous model to large systems is hindered by a great amount of computer time required for numerical integration of oscillatory and slowly convergent Sommerfeld integrals (SI). As a result, approximate methods that avoid the solution of SI, e.g. image theory-based methods, are often used for computation of the response of large grounding systems. In this paper, we extend the application of the rigorous model for large grounding systems in multilayered soil by applying a procedure that minimizes the number of direct computations of SI using interpolation over a grid of a small number of sample points. We implement three-dimensional interpolation scheme that adapts to the problem to minimize the interpolation grid, maintaining the accuracy of the rigorous approach. The developed model is applied for the analysis of transient voltages that might couple to secondary cables and disrupt the operation of connected equipment in case of lightning. Analysis shows that there are cases when the image theory-based models might underestimate possibly harmful transient voltages.
- 10 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 598-606
Fast and Accurate Transient Analysis of Large Grounding Systems in Multilayer Soil
One of the most accurate approaches to the lightning-related transient analysis of grounding systems in layered soil is based on the method of moments solution of the integral form of Maxwell equations. The practical application of this rigorous model to large systems is hindered by a great amount of computer time required for numerical integration of oscillatory and slowly convergent Sommerfeld integrals (SI). As a result, approximate methods that avoid the solution of SI, e.g. image theory-based methods, are often used for computation of the response of large grounding systems. In this paper, we extend the application of the rigorous model for large grounding systems in multilayered soil by applying a procedure that minimizes the number of direct computations of SI using interpolation over a grid of a small number of sample points. We implement three-dimensional interpolation scheme that adapts to the problem to minimize the interpolation grid, maintaining the accuracy of the rigorous approach. The developed model is applied for the analysis of transient voltages that might couple to secondary cables and disrupt the operation of connected equipment in case of lightning. Analysis shows that there are cases when the image theory-based models might underestimate possibly harmful transient voltages.
- 1 January 2020
- Published by Óbuda University in Acta Polytechnica Hungarica
- Vol. 17 (10) , 13-25
Accurate Low-Frequency Approximation for Wires within a Two-Layered Earth
- 1 January 2020
- Published by Óbuda University in Acta Polytechnica Hungarica
- Vol. 17 (10) , 13-25
Accurate Low-Frequency Approximation for Wires within a Two-Layered Earth
- 7 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 61 (4) , 1082-1090
Generalized Network Model for Energization of Grounding Electrodes
The main difference between the application of the method of moments (MoM) to grounding system and antenna analysis is the shunt energization by the injection of current. There is no consensus on the modeling of such energization, which is also crucial for the definition of quantities that characterize grounding system time and frequency behavior. The contributions of this paper are as follows: The presentation of a simple and unified approach to model all important cases of energization based on a generalized network representation of the grounding electrodes; the demonstration that the mesh current method, whose matrix equation is identical to that of the MoM, leads to straightforward procedures in the analysis of all cases of energization; and the approach enables the computation of uniquely defined impedances to ground and transfer impedances at arbitrary points at the grounding electrodes (required for N-port representation) by simple matrix manipulations. The proposed approach is general since it allows for a rigorous full-wave and an approximate quasi-static modeling, depending on the choice of Green's functions.
- 7 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 61 (4) , 1082-1090
Generalized Network Model for Energization of Grounding Electrodes
The main difference between the application of the method of moments (MoM) to grounding system and antenna analysis is the shunt energization by the injection of current. There is no consensus on the modeling of such energization, which is also crucial for the definition of quantities that characterize grounding system time and frequency behavior. The contributions of this paper are as follows: The presentation of a simple and unified approach to model all important cases of energization based on a generalized network representation of the grounding electrodes; the demonstration that the mesh current method, whose matrix equation is identical to that of the MoM, leads to straightforward procedures in the analysis of all cases of energization; and the approach enables the computation of uniquely defined impedances to ground and transfer impedances at arbitrary points at the grounding electrodes (required for N-port representation) by simple matrix manipulations. The proposed approach is general since it allows for a rigorous full-wave and an approximate quasi-static modeling, depending on the choice of Green's functions.
- 3 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (1) , 272-275
Accurate Low-Frequency Approximation for Wires Within a Conducting Half-Space
The most popular approximate models for the analysis of vertical and horizontal wires within a conducting half-space are based on image theory. However, their accuracy is often confined within some low-frequency (LF) range. Such models are often based on the integral equation technique with the so-called “traditional” choice of potentials. In this letter, a new LF approximation is derived from an alternative choice of potentials, i.e., “formulation B.” The accuracy of the proposed approximation and the traditional image approximations is evaluated by comparison with the electromagnetic simulation software FEKO for different wire geometries and different values of earth resistivity in a frequency range up to 10 MHz. It is shown that the new LF approximation is consistently more accurate in all analyzed cases, which widens its applicable frequency range in relation to the image approximations based on the traditional choice of potentials.
- 3 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (1) , 272-275
Accurate Low-Frequency Approximation for Wires Within a Conducting Half-Space
The most popular approximate models for the analysis of vertical and horizontal wires within a conducting half-space are based on image theory. However, their accuracy is often confined within some low-frequency (LF) range. Such models are often based on the integral equation technique with the so-called “traditional” choice of potentials. In this letter, a new LF approximation is derived from an alternative choice of potentials, i.e., “formulation B.” The accuracy of the proposed approximation and the traditional image approximations is evaluated by comparison with the electromagnetic simulation software FEKO for different wire geometries and different values of earth resistivity in a frequency range up to 10 MHz. It is shown that the new LF approximation is consistently more accurate in all analyzed cases, which widens its applicable frequency range in relation to the image approximations based on the traditional choice of potentials.
- Open Access
- 1 January 2018
- Published by National Library of Serbia in Facta universitatis - series: Electronics and Energetics
- Vol. 31 (3) , 487-500
Electromagnetic analysis of single/multiple grounding rods
This paper presents electromagnetic modeling of multiple driven grounding rods in homogeneous/two-layer soil. The mathematical model is formulated by mixed potential integral equation (MPIE) on the basis of Sommerfield integrals. Several configurations of multiple driven rods located in homogeneous or two-layer soil are analyzed. The authors are focused on the calculation of the current density along the rods in wide frequency range from 100Hz to 1MHz.
- 1 January 2018
- Published by National Library of Serbia in Facta universitatis - series: Electronics and Energetics
- Vol. 31 (3) , 487-500
Open AccessElectromagnetic analysis of single/multiple grounding rods
This paper presents electromagnetic modeling of multiple driven grounding rods in homogeneous/two-layer soil. The mathematical model is formulated by mixed potential integral equation (MPIE) on the basis of Sommerfield integrals. Several configurations of multiple driven rods located in homogeneous or two-layer soil are analyzed. The authors are focused on the calculation of the current density along the rods in wide frequency range from 100Hz to 1MHz.
- Open Access
- 1 January 2008
- Published by National Library of Serbia in Serbian Journal of Electrical Engineering
- Vol. 5 (1) , 1-10
Equivalent circuit model of electromagnetic behaviour of wire objects by the matrix pencil method
The electromagnetic behaviour of thin-wire objects is an important engineering problem. A general analysis of such objects is done according to the moment method approach within an antenna-based electromagnetic model. This paper concerns possible extraction of parameters that would enable determination of an equivalent circuit model of such wire-structure objects. As an example, the authors focused on the electromagnetic behaviour of high frequency power converters and grounding conductors.
- 1 January 2008
- Published by National Library of Serbia in Serbian Journal of Electrical Engineering
- Vol. 5 (1) , 1-10
Open AccessEquivalent circuit model of electromagnetic behaviour of wire objects by the matrix pencil method
The electromagnetic behaviour of thin-wire objects is an important engineering problem. A general analysis of such objects is done according to the moment method approach within an antenna-based electromagnetic model. This paper concerns possible extraction of parameters that would enable determination of an equivalent circuit model of such wire-structure objects. As an example, the authors focused on the electromagnetic behaviour of high frequency power converters and grounding conductors.
- Open Access
- 1 January 2007
- Published by National Library of Serbia in Facta universitatis - series: Electronics and Energetics
- Vol. 20 (1) , 1-8
Computation and measurement of low frequency magnetic field near thin-wire structures
Magnetic fields in residential and occupational environments attract attention due to concerns of health risks. This paper describes comparison of two simple numerical procedures for computation of magnetic fields due to sources typical for residential environment which can be also used for teaching purposes. The methods are confirmed with the results obtained by analytical closed form solution and experimental laboratory measurements.
- 1 January 2007
- Published by National Library of Serbia in Facta universitatis - series: Electronics and Energetics
- Vol. 20 (1) , 1-8
Open AccessComputation and measurement of low frequency magnetic field near thin-wire structures
Magnetic fields in residential and occupational environments attract attention due to concerns of health risks. This paper describes comparison of two simple numerical procedures for computation of magnetic fields due to sources typical for residential environment which can be also used for teaching purposes. The methods are confirmed with the results obtained by analytical closed form solution and experimental laboratory measurements.
- Open Access
- 1 January 2005
- Published by National Library of Serbia in Serbian Journal of Electrical Engineering
- Vol. 2 (2) , 117-124
Radiated EMI from power converters
With the continuous increase of switching frequency together with the ongoing trend to higher complexity and functionality, power converters as a part of electronic systems have raised more and more electromagnetic energy pollution to the local system environment. In the same time, stringent demands are imposed on the designers of new circuits that electromagnetic interference (EMI) has to be suppressed at its source before it is allowed to propagate into other circuits and systems. In this paper, the authors present a full-wave numerical method for calculation and simulation of electromagnetic field radiated by power converter circuitry. The main objective is to analyze the layout geometry in order to obtain competitive PCB layout that will enable suitably attenuated level of the radiated electric field to safe level. By this it would be possible to ensure reliable operation of the sensitive electronic components in the proximity.
- 1 January 2005
- Published by National Library of Serbia in Serbian Journal of Electrical Engineering
- Vol. 2 (2) , 117-124
Open AccessRadiated EMI from power converters
With the continuous increase of switching frequency together with the ongoing trend to higher complexity and functionality, power converters as a part of electronic systems have raised more and more electromagnetic energy pollution to the local system environment. In the same time, stringent demands are imposed on the designers of new circuits that electromagnetic interference (EMI) has to be suppressed at its source before it is allowed to propagate into other circuits and systems. In this paper, the authors present a full-wave numerical method for calculation and simulation of electromagnetic field radiated by power converter circuitry. The main objective is to analyze the layout geometry in order to obtain competitive PCB layout that will enable suitably attenuated level of the radiated electric field to safe level. By this it would be possible to ensure reliable operation of the sensitive electronic components in the proximity.