Blagoja Markovski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Blagoja Markovski has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Leonid Grcev
Macedonian Academy of Sciences and Arts, Skopje, Macedonia
12 shared publications - Mirko Todorovski
Faculty of Electrical Engineering and Information Technologies, Ss. Cyril and Methodius University in Skopje, Skopje, Macedonia
5 shared publications - Vesna Arnautovski-Toseva
Faculty of Electrical Engineering, University of Skopje, Skopje Macedonia, The Former Yugoslav Republic of
4 shared publications Andrijana Kuhar
3 shared publications- Andrijana Kuhar
Institute of Electronics, Faculty of Electrical Engineering and Information Technologies, “Ss. Cyril and Methodius” University in Skopje, 1000 Skopje, North Macedonia
2 shared publications Leonid Grcev
2 shared publications
Latest Publications
- 18 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 67 (1) , 328-331
On Communication Tower Grounding Under Lightning Currents
The recommended typical grounding of a communication tower comprises a ring with radial counterpoises. However, guidance on determining the size and layout for actual practical situations is lacking. This letter presents simple formulas for grounding resistance, impulse impedance, and effective length of the radial counterpoises, which can help analyze optimal grounding configurations for lightning protection.
- 18 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 67 (1) , 328-331
On Communication Tower Grounding Under Lightning Currents
The recommended typical grounding of a communication tower comprises a ring with radial counterpoises. However, guidance on determining the size and layout for actual practical situations is lacking. This letter presents simple formulas for grounding resistance, impulse impedance, and effective length of the radial counterpoises, which can help analyze optimal grounding configurations for lightning protection.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (6) , 1998-2005
An Image Method for Evaluating Partial Inductance in Conducting Half-Space
Partial inductances are required in the circuit-based models of wire-like structures within a conducting half-space. Different approaches were used to calculate partial inductances, which mainly varied between applying or not applying the mirror image theory. The mirror image theory is applied to the electric field; however, the rigorous analysis in this article shows that it does not hold for the magnetic field in the general case. This article introduces an accurate image method developed for the magnetic field in a conducting half-space suitable for practical computations. New closed-form formulas for partial inductances were derived for some typical cases, but for the general case with conductors in arbitrary positions, it is more efficient to use numerical integration. For such a purpose, a MATLAB script is provided. It has been shown that frequently used approximations can lead to significant errors.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (6) , 1998-2005
An Image Method for Evaluating Partial Inductance in Conducting Half-Space
Partial inductances are required in the circuit-based models of wire-like structures within a conducting half-space. Different approaches were used to calculate partial inductances, which mainly varied between applying or not applying the mirror image theory. The mirror image theory is applied to the electric field; however, the rigorous analysis in this article shows that it does not hold for the magnetic field in the general case. This article introduces an accurate image method developed for the magnetic field in a conducting half-space suitable for practical computations. New closed-form formulas for partial inductances were derived for some typical cases, but for the general case with conductors in arbitrary positions, it is more efficient to use numerical integration. For such a purpose, a MATLAB script is provided. It has been shown that frequently used approximations can lead to significant errors.
- 28 July 2023
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (7) , 225-228
Parametric Analysis of Conductive Coupling of Transmission Line Tower Grounding and Pipeline in Multilayer Soil
Faults in electric power system may give rise of coating stress voltages on nearby pipelines due to mutual electromagnetic coupling. To prevent hazardous situations, accurate modelling of the electromagnetic interactions between such systems is required. In this paper, we perform parametric analysis of the effects of multilayer soil and of the effectiveness of different mitigation techniques in reducing coating stress voltages on a short pipeline section due to conductive coupling. Analyses are performed using full-wave electromagnetic model, based on the method of moments.
- 28 July 2023
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (7) , 225-228
Parametric Analysis of Conductive Coupling of Transmission Line Tower Grounding and Pipeline in Multilayer Soil
Faults in electric power system may give rise of coating stress voltages on nearby pipelines due to mutual electromagnetic coupling. To prevent hazardous situations, accurate modelling of the electromagnetic interactions between such systems is required. In this paper, we perform parametric analysis of the effects of multilayer soil and of the effectiveness of different mitigation techniques in reducing coating stress voltages on a short pipeline section due to conductive coupling. Analyses are performed using full-wave electromagnetic model, based on the method of moments.
- 22 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (2) , 877-888
Lightning Efficient Counterpoise Configurations for Transmission Line Grounding
Different configurations of counterpoises are often used to reduce the resistance and impulse impedance of the transmission line grounding. However, there are no general rules for an actual design. This paper analyses the performance of several configurations of counterpoises under typical lightning current impulses. The basis is a parametric analysis derived from time responses of 11,386 test cases for each configuration with parameters in broad ranges computed using a rigorous electromagnetic model based on the method of moments. The contributions of the paper are: Simple formulas for the resistance, impulse impedance, and effective length of counterpoise configurations are derived from and verified by the simulation results; a configuration with an 8-leg counterpoise bent parallel to the line is proposed, which extends the effective length and is efficient in high resistivity soil; and the method does not depend on the different lightning current impulse waveform representations based on Heidler, CIGRE, and double-exponential formulas, since the results can be easily converted. A simple procedure is provided to compare the capabilities and limitations of counterpoise configurations. New formulas and procedures make up a general and straightforward method for analyzing the optimal design, considering the cost-effective and best protection against lightning.
- 22 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (2) , 877-888
Lightning Efficient Counterpoise Configurations for Transmission Line Grounding
Different configurations of counterpoises are often used to reduce the resistance and impulse impedance of the transmission line grounding. However, there are no general rules for an actual design. This paper analyses the performance of several configurations of counterpoises under typical lightning current impulses. The basis is a parametric analysis derived from time responses of 11,386 test cases for each configuration with parameters in broad ranges computed using a rigorous electromagnetic model based on the method of moments. The contributions of the paper are: Simple formulas for the resistance, impulse impedance, and effective length of counterpoise configurations are derived from and verified by the simulation results; a configuration with an 8-leg counterpoise bent parallel to the line is proposed, which extends the effective length and is efficient in high resistivity soil; and the method does not depend on the different lightning current impulse waveform representations based on Heidler, CIGRE, and double-exponential formulas, since the results can be easily converted. A simple procedure is provided to compare the capabilities and limitations of counterpoise configurations. New formulas and procedures make up a general and straightforward method for analyzing the optimal design, considering the cost-effective and best protection against lightning.
- 21 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3782-3791
Lightning Performance of Multiple Horizontal, Vertical and Inclined Grounding Electrodes
Single horizontal and vertical grounding electrodes are often used for an earth connection of the lightning protection system. However, there are many practical situations when such electrodes have to be enhanced for better efficiency and replaced by multiple horizontal, vertical and/or inclined electrodes. This paper presents a systematic approach to evaluating and comparing the lightning performance of such grounding arrangements based on simple formulas. The contributions of this paper are: It is shown that impulse impedance Z may be derived from known formulas for low-frequency grounding resistance R ; a new definition of effective length is introduced that allows for such a derivation; a collection of accurate formulas for R of all considered grounding electrode arrangements is presented; and a new concept of “effective volume” is described that enables a simple procedure to increase electrodes’ effective length. The new formulas for R , Z , and effective length of the different electrode arrangements allow an analysis that might help search for a choice of cost-effective configuration and dimensions of the grounding systems in the early design stage.
- 21 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3782-3791
Lightning Performance of Multiple Horizontal, Vertical and Inclined Grounding Electrodes
Single horizontal and vertical grounding electrodes are often used for an earth connection of the lightning protection system. However, there are many practical situations when such electrodes have to be enhanced for better efficiency and replaced by multiple horizontal, vertical and/or inclined electrodes. This paper presents a systematic approach to evaluating and comparing the lightning performance of such grounding arrangements based on simple formulas. The contributions of this paper are: It is shown that impulse impedance Z may be derived from known formulas for low-frequency grounding resistance R ; a new definition of effective length is introduced that allows for such a derivation; a collection of accurate formulas for R of all considered grounding electrode arrangements is presented; and a new concept of “effective volume” is described that enables a simple procedure to increase electrodes’ effective length. The new formulas for R , Z , and effective length of the different electrode arrangements allow an analysis that might help search for a choice of cost-effective configuration and dimensions of the grounding systems in the early design stage.
- 13 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (4) , 2245-2248
General Formulas for Lightning Impulse Impedance of Horizontal and Vertical Grounding Electrodes
Voltage drop developed between the grounding electrode under lightning current and distant neutral ground determines the protection efficiency. The peak value of such voltage can be computed from known impulse impedance and current peak value. For the first time, in this paper, general formulas are de-rived for impulse impedance of horizontal and vertical electrodes valid for any length up to 100 m, soil's resistivity of 30 to 1000 m, and current impulse front time of 0.2 to 10 s. Waveforms of typical lightning impulses given in IEC standards are used, but it is shown that results are also relevant for other impulse waveforms. Soil ionization effects are taken into account, and the accuracy of the formulas is investigated. New formulas enable an estimate of lightning protection grounding's surge efficiency in a wide range of practical situations.
- 13 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (4) , 2245-2248
General Formulas for Lightning Impulse Impedance of Horizontal and Vertical Grounding Electrodes
Voltage drop developed between the grounding electrode under lightning current and distant neutral ground determines the protection efficiency. The peak value of such voltage can be computed from known impulse impedance and current peak value. For the first time, in this paper, general formulas are de-rived for impulse impedance of horizontal and vertical electrodes valid for any length up to 100 m, soil's resistivity of 30 to 1000 m, and current impulse front time of 0.2 to 10 s. Waveforms of typical lightning impulses given in IEC standards are used, but it is shown that results are also relevant for other impulse waveforms. Soil ionization effects are taken into account, and the accuracy of the formulas is investigated. New formulas enable an estimate of lightning protection grounding's surge efficiency in a wide range of practical situations.
- 18 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 1183-1192
Impulse Impedance and Effective Area of Grounding Grids
High values and uneven distribution of the transient ground potential rise (TGPR) at the grounding grid conductors in some cases of lightning can disrupt system safety and reliability. To assess the transient performance of grounding grids under lightning currents, a parametric analysis was performed with a computer simulation of 13,978 cases of time-domain responses with parameters in broad ranges. From this study, graphs of impulse impedance and a new formula for the effective area have been developed. The graphs are general; they are for grids of any shape and size and depend on three parameters: the grid conductor spacing, the resistivity of earth, and the zero-to-peak time of the lightning current pulse. In this paper, they are used in a simple procedure to estimate the effectiveness of a mitigation measure to reduce TGPR by increasing the grounding grid mesh density in a limited area around current injection points. Although the parametric analysis was based on a uniform soil model, the graphs can also be used for the two-layer soil model. The procedure is compared with experimental results and its application and limitations are illustrated in examples of large grounding grids.
- 18 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 1183-1192
Impulse Impedance and Effective Area of Grounding Grids
High values and uneven distribution of the transient ground potential rise (TGPR) at the grounding grid conductors in some cases of lightning can disrupt system safety and reliability. To assess the transient performance of grounding grids under lightning currents, a parametric analysis was performed with a computer simulation of 13,978 cases of time-domain responses with parameters in broad ranges. From this study, graphs of impulse impedance and a new formula for the effective area have been developed. The graphs are general; they are for grids of any shape and size and depend on three parameters: the grid conductor spacing, the resistivity of earth, and the zero-to-peak time of the lightning current pulse. In this paper, they are used in a simple procedure to estimate the effectiveness of a mitigation measure to reduce TGPR by increasing the grounding grid mesh density in a limited area around current injection points. Although the parametric analysis was based on a uniform soil model, the graphs can also be used for the two-layer soil model. The procedure is compared with experimental results and its application and limitations are illustrated in examples of large grounding grids.
- 10 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 598-606
Fast and Accurate Transient Analysis of Large Grounding Systems in Multilayer Soil
One of the most accurate approaches to the lightning-related transient analysis of grounding systems in layered soil is based on the method of moments solution of the integral form of Maxwell equations. The practical application of this rigorous model to large systems is hindered by a great amount of computer time required for numerical integration of oscillatory and slowly convergent Sommerfeld integrals (SI). As a result, approximate methods that avoid the solution of SI, e.g. image theory-based methods, are often used for computation of the response of large grounding systems. In this paper, we extend the application of the rigorous model for large grounding systems in multilayered soil by applying a procedure that minimizes the number of direct computations of SI using interpolation over a grid of a small number of sample points. We implement three-dimensional interpolation scheme that adapts to the problem to minimize the interpolation grid, maintaining the accuracy of the rigorous approach. The developed model is applied for the analysis of transient voltages that might couple to secondary cables and disrupt the operation of connected equipment in case of lightning. Analysis shows that there are cases when the image theory-based models might underestimate possibly harmful transient voltages.
- 10 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 598-606
Fast and Accurate Transient Analysis of Large Grounding Systems in Multilayer Soil
One of the most accurate approaches to the lightning-related transient analysis of grounding systems in layered soil is based on the method of moments solution of the integral form of Maxwell equations. The practical application of this rigorous model to large systems is hindered by a great amount of computer time required for numerical integration of oscillatory and slowly convergent Sommerfeld integrals (SI). As a result, approximate methods that avoid the solution of SI, e.g. image theory-based methods, are often used for computation of the response of large grounding systems. In this paper, we extend the application of the rigorous model for large grounding systems in multilayered soil by applying a procedure that minimizes the number of direct computations of SI using interpolation over a grid of a small number of sample points. We implement three-dimensional interpolation scheme that adapts to the problem to minimize the interpolation grid, maintaining the accuracy of the rigorous approach. The developed model is applied for the analysis of transient voltages that might couple to secondary cables and disrupt the operation of connected equipment in case of lightning. Analysis shows that there are cases when the image theory-based models might underestimate possibly harmful transient voltages.
- 1 January 2020
- Published by Óbuda University in Acta Polytechnica Hungarica
- Vol. 17 (10) , 13-25
Accurate Low-Frequency Approximation for Wires within a Two-Layered Earth
- 1 January 2020
- Published by Óbuda University in Acta Polytechnica Hungarica
- Vol. 17 (10) , 13-25
Accurate Low-Frequency Approximation for Wires within a Two-Layered Earth
- 5 May 2019
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (5) , 11-15
Improving Efficiency of Full-Wave Electromagnetic Analysis of Grounding Systems Within Homogeneous Earth
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 May 2019
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (5) , 11-15
Improving Efficiency of Full-Wave Electromagnetic Analysis of Grounding Systems Within Homogeneous Earth
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.