João Neudenir Arioli Filho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
João Neudenir Arioli Filho has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Mariana de Almeida Basílio
Adjunct Professor, Department of Clinical Odontology, School of Dentistry, Federal University of Bahia, Salvador, Bahia, Brazil
3 shared publications Luis Eduardo Butignon
2 shared publications- Amin Sami Rizkalla
Division of Restorative Dentistry, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 3K7, Canada
1 shared publication Francisco de Assis
1 shared publication- Francisco de Assis Mollo
Sao Paulo State University
1 shared publication - Gildo Coelho Santos
Division of Restorative Dentistry, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 5C1, Canada
1 shared publication
Latest Publications
- 12 October 2012
- Vol. 27 (5) , 1061-7
Effectiveness of screw surface coating on the stability of zirconia abutments after cyclic loading.
Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 X 106 cycles was defined. Group means were calculated and compared using analysis of variance and the F test (α = .05). Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P = .021). After cyclic loading, there was no significant difference between them (P = .499). Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload.
- 12 October 2012
- Vol. 27 (5) , 1061-7
Effectiveness of screw surface coating on the stability of zirconia abutments after cyclic loading.
Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 X 106 cycles was defined. Group means were calculated and compared using analysis of variance and the F test (α = .05). Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P = .021). After cyclic loading, there was no significant difference between them (P = .499). Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload.
- Open Access
- 1 June 2011
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 19 (3) , 249-253
Flexural strength of acrylic resin repairs processed by different methods: water bath, microwave energy and chemical polymerization
The aim of this study was to evaluate the flexural strength of acrylic resin repairs processed by different methods: warm water-bath, microwave energy, and chemical polymerization. Sixty rectangular specimens (31x10x2.5 mm) were made with warm water-bath acrylic resin (Lucitone 550) and grouped (15 specimens per group) according to the resin type used to make repair procedure: 1) specimens of warm water-bath resin (Lucitone 550) without repair (control group); 2) specimens of warm water-bath resin repaired with warm water-bath; 3) specimens of warm water-bath resin repaired with microwave resin (Acron MC); 4) specimens of warm water-bath resin repaired with autopolymerized acrylic resin (Simplex). Flexural strength was measured with the three-point bending in a universal testing machine (MTS 810 Material Test System) with load cell of 100 kgf under constant speed of 5 mm/min. Data were analyzed statistically by Kruskal-Wallis test (p<0.05). The control group showed the best result (156.04±1.82 MPa). Significant differences were found among repaired specimens and the results were decreasing as follows: group 3 (43.02±2.25 MPa), group 2 (36.21±1.20 MPa) and group 4 (6.74±0.85 MPa). All repaired specimens demonstrated lower flexural strength than the control group. Repairs with autopolymerized acrylic resin showed the lowest flexural strength.
- 1 June 2011
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 19 (3) , 249-253
Open AccessFlexural strength of acrylic resin repairs processed by different methods: water bath, microwave energy and chemical polymerization
The aim of this study was to evaluate the flexural strength of acrylic resin repairs processed by different methods: warm water-bath, microwave energy, and chemical polymerization. Sixty rectangular specimens (31x10x2.5 mm) were made with warm water-bath acrylic resin (Lucitone 550) and grouped (15 specimens per group) according to the resin type used to make repair procedure: 1) specimens of warm water-bath resin (Lucitone 550) without repair (control group); 2) specimens of warm water-bath resin repaired with warm water-bath; 3) specimens of warm water-bath resin repaired with microwave resin (Acron MC); 4) specimens of warm water-bath resin repaired with autopolymerized acrylic resin (Simplex). Flexural strength was measured with the three-point bending in a universal testing machine (MTS 810 Material Test System) with load cell of 100 kgf under constant speed of 5 mm/min. Data were analyzed statistically by Kruskal-Wallis test (p<0.05). The control group showed the best result (156.04±1.82 MPa). Significant differences were found among repaired specimens and the results were decreasing as follows: group 3 (43.02±2.25 MPa), group 2 (36.21±1.20 MPa) and group 4 (6.74±0.85 MPa). All repaired specimens demonstrated lower flexural strength than the control group. Repairs with autopolymerized acrylic resin showed the lowest flexural strength.
- 14 June 2008
- Vol. 23 (2) , 226-36
Accuracy of impression and pouring techniques for an implant-supported prosthesis.
The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). The mean gap value with the index technique was 27.07 microm. With the conventional pouring technique, the mean gap values were 116.97 microm for the tapered group, 57.84 microm for the squared group, and 73.17 microm for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 microm for the tapered group, 38.03 microm for the squared group, and 82.47 microm for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 microm for the tapered group, 74.19 microm for the squared group, and 104.67 microm for the squared splinted group. No significant difference was detected among Index, square/latex techniques, and master cast (P >.05). The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.
- 14 June 2008
- Vol. 23 (2) , 226-36
Accuracy of impression and pouring techniques for an implant-supported prosthesis.
The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). The mean gap value with the index technique was 27.07 microm. With the conventional pouring technique, the mean gap values were 116.97 microm for the tapered group, 57.84 microm for the squared group, and 73.17 microm for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 microm for the tapered group, 38.03 microm for the squared group, and 82.47 microm for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 microm for the tapered group, 74.19 microm for the squared group, and 104.67 microm for the squared splinted group. No significant difference was detected among Index, square/latex techniques, and master cast (P >.05). The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.