Mariana de Almeida Basílio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mariana de Almeida Basílio has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- João Neudenir Arioli Filho
UNESP - University Estadual Paulista, Araraquara School of Dentistry, Department of Dental Materials and Prosthodontics, 1680, Araraquara 14801-903, SP, Brazil
3 shared publications Luis Eduardo Butignon
3 shared publicationsJoão Neudenir Arioli Filho
Adjunct Professor. Department of Dental Materials and Prosthodontics, São Paulo State University, Araraquara School of Dentistry, São Paulo, Brazil
2 shared publicationsAmin Sami Rizkalla
Associate Professor, Department of Medical Biophysics, Western University, Schulich School of Medicine & Dentistry, London, Ontario, Canada
1 shared publication- Amin Sami Rizkalla
Division of Restorative Dentistry, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 3K7, Canada
1 shared publication Filipe de Oliveira Abi‐Rached
Department of Dental Materials and Prosthodontics, UNESP-Univ Estadual Paulista, Araraquara School of Dentistry, Araraquara, São Paulo, Brazil
1 shared publication
Latest Publications
- Open Access
- 7 May 2021
- Published by Open Source Publications in Journal of Clinical Images and Medical Case Reports
- Vol. 1 (3)
The socket-shield technique and early implant placement for tooth rehabilitation: A case report
For a long time, different approaches to minimize the dimensional ridge alteration following tooth extraction have been described even though none of them was capable to avoid alveolar bone loss. The Socket-Shield Technique (SST) seems to be an alternative for alveolar bone preservation in dental extraction planning. This technique conventionally uses a flapless approach and the buccal root portion retention to prevent bone loss. This case report describes the SST with an early implant placement in a patient who presented the nonrestorable tooth # 15 due to the extensive cavity. After six months of the implant placement a porcelain-fused-to-metal crown was fabricated and screwed into the implant with a satisfactory esthetic and functional result. The SST is a non-invasive and effective approach to tooth extraction and rehabilitation, especially in the aesthetic zone. Approximately two-year follow-up shows a satisfactory aesthetic maintenance.
- 7 May 2021
- Published by Open Source Publications in Journal of Clinical Images and Medical Case Reports
- Vol. 1 (3)
Open AccessThe socket-shield technique and early implant placement for tooth rehabilitation: A case report
For a long time, different approaches to minimize the dimensional ridge alteration following tooth extraction have been described even though none of them was capable to avoid alveolar bone loss. The Socket-Shield Technique (SST) seems to be an alternative for alveolar bone preservation in dental extraction planning. This technique conventionally uses a flapless approach and the buccal root portion retention to prevent bone loss. This case report describes the SST with an early implant placement in a patient who presented the nonrestorable tooth # 15 due to the extensive cavity. After six months of the implant placement a porcelain-fused-to-metal crown was fabricated and screwed into the implant with a satisfactory esthetic and functional result. The SST is a non-invasive and effective approach to tooth extraction and rehabilitation, especially in the aesthetic zone. Approximately two-year follow-up shows a satisfactory aesthetic maintenance.
- 1 September 2016
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 31 (5) , 1017-1022
Vertical Misfit of Single-Implant Abutments Made from Different Materials Under Cyclic Loading
Luis Eduardo Butignon, DDS, MSc, PhD/Mariana de Almeida Bas?lio, DDS, MSc/Julia Sgavioli Santo/Jo?o Neudenir Arioli Filho, DDS, MSc, PhD: Purpose: Little information is available in the literature regarding the accuracy of marginal fit of abutments made from different materials. The aim of this study was to compare the level of vertical misfit in abutments made from different materials before and after cyclic loading. Materials and Methods: Thirty external hexagon implants, 3.75-mm diameter and 13-mm length, were embedded in epoxy resin and divided into three groups according to abutment type (n = 10): (1) machined titanium (Ti) abutments; (2) premachined gold-alloy (Au) abutments; and (3) machined zirconia (Zr) abutments. The abutments were attached to their respective implants by titanium alloy screws at the manufacturer?s recommended torque. A cyclic loading (0.5 ? 106 cycles; 15 Hz) between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants. Implant-abutment vertical misfits (μm) were measured at four predetermined points before and after loading with a stereomicroscope at 60? magnification. The group means were compared using a three-way repeated-measure analysis of variance (ANOVA) and Tukey test (α = .05). Results: The results from the ANOVA identified significant effects of the abutment type (P < .001). However, there were no significant effects of cyclic loading (P = .978) or measured surfaces (P = .955). When the abutment groups were compared regardless of cyclic loading and measured surfaces, the Au group showed the highest value of vertical misfit (14.93 ? 0.78), followed by the Ti group (8.53 ? 0.44) and the Zr group (5.64 ? 0.73), with statistically significant differences among them (P < .05). Conclusion: The abutment groups showed statistically significant differences in vertical misfit. Zr abutments showed the highest accuracy in terms of marginal fit, and Au abutments showed the lowest. Cyclic loading did not significantly change the level of vertical misfit. All experimental groups presented acceptable values of marginal misfit.
- 1 September 2016
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 31 (5) , 1017-1022
Vertical Misfit of Single-Implant Abutments Made from Different Materials Under Cyclic Loading
Luis Eduardo Butignon, DDS, MSc, PhD/Mariana de Almeida Bas?lio, DDS, MSc/Julia Sgavioli Santo/Jo?o Neudenir Arioli Filho, DDS, MSc, PhD: Purpose: Little information is available in the literature regarding the accuracy of marginal fit of abutments made from different materials. The aim of this study was to compare the level of vertical misfit in abutments made from different materials before and after cyclic loading. Materials and Methods: Thirty external hexagon implants, 3.75-mm diameter and 13-mm length, were embedded in epoxy resin and divided into three groups according to abutment type (n = 10): (1) machined titanium (Ti) abutments; (2) premachined gold-alloy (Au) abutments; and (3) machined zirconia (Zr) abutments. The abutments were attached to their respective implants by titanium alloy screws at the manufacturer?s recommended torque. A cyclic loading (0.5 ? 106 cycles; 15 Hz) between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants. Implant-abutment vertical misfits (μm) were measured at four predetermined points before and after loading with a stereomicroscope at 60? magnification. The group means were compared using a three-way repeated-measure analysis of variance (ANOVA) and Tukey test (α = .05). Results: The results from the ANOVA identified significant effects of the abutment type (P < .001). However, there were no significant effects of cyclic loading (P = .978) or measured surfaces (P = .955). When the abutment groups were compared regardless of cyclic loading and measured surfaces, the Au group showed the highest value of vertical misfit (14.93 ? 0.78), followed by the Ti group (8.53 ? 0.44) and the Zr group (5.64 ? 0.73), with statistically significant differences among them (P < .05). Conclusion: The abutment groups showed statistically significant differences in vertical misfit. Zr abutments showed the highest accuracy in terms of marginal fit, and Au abutments showed the lowest. Cyclic loading did not significantly change the level of vertical misfit. All experimental groups presented acceptable values of marginal misfit.
- 1 August 2016
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 116 (2) , 277-285
Effects of artificial aging conditions on yttria-stabilized zirconia implant abutments
- 1 August 2016
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 116 (2) , 277-285
Effects of artificial aging conditions on yttria-stabilized zirconia implant abutments
- 8 February 2016
- Published by Wiley in Journal of Prosthodontics
- Vol. 26 (8) , 656-658
Influence of Liquid Lubrication on the Screw‐Joint Stability of Y‐TZP Implant Abutment Systems
Purpose: To evaluate the effectiveness of abutment screws coated with liquid Vaseline on the screw‐joint stability of yttria‐stabilized tetragonal zirconia (Y‐TZP) abutment systems.Materials and Methods: Forty Y‐TZP prefabricated abutments, 20 Neodent and 20 Bionnovation, were tightened to 20 Ncm on their respective external hexagon implants, and divided into four groups (n = 10) according to the screws: coated with Vaseline or uncoated. The removal torque (RT) value of the abutment screw was measured before and after loading. A cyclic loading (0.5 × 106 cycles; 15 Hz) between 11 and 211 N was applied. Means were compared using a repeated‐measures ANOVA (α = 0.05).Results: There was no significant difference between coated and uncoated screws (p = 0.822). Significant differences were found between the abutment systems (p < 0.001). There was a significant effect of cyclic loading (p < 0.001).Conclusions: Coated and uncoated screws presented similar effectiveness in maintaining preload.Clinical Relevance: The liquid lubricant used in this study does not influence the stability of Y‐TZP single‐implant restorations.
- 8 February 2016
- Published by Wiley in Journal of Prosthodontics
- Vol. 26 (8) , 656-658
Influence of Liquid Lubrication on the Screw‐Joint Stability of Y‐TZP Implant Abutment Systems
Purpose: To evaluate the effectiveness of abutment screws coated with liquid Vaseline on the screw‐joint stability of yttria‐stabilized tetragonal zirconia (Y‐TZP) abutment systems.Materials and Methods: Forty Y‐TZP prefabricated abutments, 20 Neodent and 20 Bionnovation, were tightened to 20 Ncm on their respective external hexagon implants, and divided into four groups (n = 10) according to the screws: coated with Vaseline or uncoated. The removal torque (RT) value of the abutment screw was measured before and after loading. A cyclic loading (0.5 × 106 cycles; 15 Hz) between 11 and 211 N was applied. Means were compared using a repeated‐measures ANOVA (α = 0.05).Results: There was no significant difference between coated and uncoated screws (p = 0.822). Significant differences were found between the abutment systems (p < 0.001). There was a significant effect of cyclic loading (p < 0.001).Conclusions: Coated and uncoated screws presented similar effectiveness in maintaining preload.Clinical Relevance: The liquid lubricant used in this study does not influence the stability of Y‐TZP single‐implant restorations.
- 1 January 2013
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 28 (3) , e161-e170
Influence of Three Types of Abutments on Preload Values Before and After Cyclic Loading with Structural Analysis by Scanning Electron Microscopy
Luis Eduardo Butignon, DDS, MSc/Mariana de Almeida Bas?lio, DDS, MSc/Rodrigo de Paula Pereira, DDS, MSc/Jo?o Neudenir Arioli Filho, DDS, MSc, PhD: Purpose: To evaluate the effectiveness of three types of abutments in the maintenance of screw joint preload before and after cyclic loading as well as to observe possible microdamage in the structure of the components using a scanning electron microscope (SEM). Materials and Methods: Forty-five external-hex implants were embedded in epoxy resin, received their respective abutments, and were randomly divided into three experimental groups (n = 15): (1) machined titanium (Ti) abutments; (2) pre-machined gold (Au) abutments; and (3) machined zirconia (ZrO2) abutments. The abutment screws were tightened according to the manufacturer?s recommended torque. Initially, a static bending test was performed using five specimens of each group to determine the load applied in the cyclic loading test. Thus, 10 specimens of each group were used to measure the reverse torque value (preload) of the abutment screw before and after loading. A cyclic loading (0.5 ? 106 cycles; 15 Hz) between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants. The group means were compared using analysis of variance and the Tukey test (α = .05). Results: The reverse torque analysis before cyclic loading showed no significant difference among the groups (P > .05). After cyclic loading, all preload means decreased significantly. The lowest decrease in preload was observed in the Ti group, whereas the highest decrease was observed in the ZrO2 group, with a significant difference noted between them (P = .010). The Au group presented an intermediate decrease, with no significant difference compared to the other groups (P > .05). SEM images showed structural changes in the mating surfaces of the abutments after cyclic loading. Conclusion: The load application reduced the preload means significantly in all groups, and more significantly in the ZrO2 group. Int J Oral Maxillofac Implants 2013;28:e161?e170. doi: 10.11607/jomi.2481
- 1 January 2013
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 28 (3) , e161-e170
Influence of Three Types of Abutments on Preload Values Before and After Cyclic Loading with Structural Analysis by Scanning Electron Microscopy
Luis Eduardo Butignon, DDS, MSc/Mariana de Almeida Bas?lio, DDS, MSc/Rodrigo de Paula Pereira, DDS, MSc/Jo?o Neudenir Arioli Filho, DDS, MSc, PhD: Purpose: To evaluate the effectiveness of three types of abutments in the maintenance of screw joint preload before and after cyclic loading as well as to observe possible microdamage in the structure of the components using a scanning electron microscope (SEM). Materials and Methods: Forty-five external-hex implants were embedded in epoxy resin, received their respective abutments, and were randomly divided into three experimental groups (n = 15): (1) machined titanium (Ti) abutments; (2) pre-machined gold (Au) abutments; and (3) machined zirconia (ZrO2) abutments. The abutment screws were tightened according to the manufacturer?s recommended torque. Initially, a static bending test was performed using five specimens of each group to determine the load applied in the cyclic loading test. Thus, 10 specimens of each group were used to measure the reverse torque value (preload) of the abutment screw before and after loading. A cyclic loading (0.5 ? 106 cycles; 15 Hz) between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants. The group means were compared using analysis of variance and the Tukey test (α = .05). Results: The reverse torque analysis before cyclic loading showed no significant difference among the groups (P > .05). After cyclic loading, all preload means decreased significantly. The lowest decrease in preload was observed in the Ti group, whereas the highest decrease was observed in the ZrO2 group, with a significant difference noted between them (P = .010). The Au group presented an intermediate decrease, with no significant difference compared to the other groups (P > .05). SEM images showed structural changes in the mating surfaces of the abutments after cyclic loading. Conclusion: The load application reduced the preload means significantly in all groups, and more significantly in the ZrO2 group. Int J Oral Maxillofac Implants 2013;28:e161?e170. doi: 10.11607/jomi.2481
- 12 October 2012
- Vol. 27 (5) , 1061-7
Effectiveness of screw surface coating on the stability of zirconia abutments after cyclic loading.
Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 X 106 cycles was defined. Group means were calculated and compared using analysis of variance and the F test (α = .05). Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P = .021). After cyclic loading, there was no significant difference between them (P = .499). Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload.
- 12 October 2012
- Vol. 27 (5) , 1061-7
Effectiveness of screw surface coating on the stability of zirconia abutments after cyclic loading.
Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 X 106 cycles was defined. Group means were calculated and compared using analysis of variance and the F test (α = .05). Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P = .021). After cyclic loading, there was no significant difference between them (P = .499). Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload.