SNShamim Nemati

Shamim Nemati

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shamim Nemati has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Discovering shared cardiovascular dynamics within a patient cohort

    by Shamim Nemati, Li-Wei H. Lehman, Ryan P. Adams, Atul Malhotra

    Cardiovascular variables such as heart rate (HR) and blood pressure (BP) are robustly regulated by an underlying control system. Time series of HR and BP exhibit distinct dynamical patterns of interaction in response to perturbations (e.g., drugs or exercise) as well as in pathological states (e.g., excessive sympathetic activation). A question of interest is whether “similar” dynamical patterns can be identified across a heterogeneous patient cohort. In this work, we present a technique based on switching linear dynamical systems for identification of shared dynamical patterns in the time series of HR and BP recorded from a patient cohort. The technique uses a mixture of linear dynamical systems, the components of which are shared across all patients, to capture both nonlinear dynamics and non-Gaussian perturbations. We present exploratory results based on a simulation study of the cardiovascular system, and real recordings from 10 healthy subjects undergoing a tilt-table test. These results demonstrate the ability of the proposed technique to identify similar dynamical patterns present across multiple time series.


  • Open Access

    Transfer Entropy Estimation and Directional Coupling Change Detection in Biomedical Time Series

    by Joon Lee, Shamim Nemati, Ikaro Silva, Bradley A Edwards, James P Butler, Atul Malhotra

    The detection of change in magnitude of directional coupling between two non-linear time series is a common subject of interest in the biomedical domain, including studies involving the respiratory chemoreflex system. Although transfer entropy is a useful tool in this avenue, no study to date has investigated how different transfer entropy estimation methods perform in typical biomedical applications featuring small sample size and presence of outliers. With respect to detection of increased coupling strength, we compared three transfer entropy estimation techniques using both simulated time series and respiratory recordings from lambs. The following estimation methods were analyzed: fixed-binning with ranking, kernel density estimation (KDE), and the Darbellay-Vajda (D-V) adaptive partitioning algorithm extended to three dimensions. In the simulated experiment, sample size was varied from 50 to 200, while coupling strength was increased. In order to introduce outliers, the heavy-tailed Laplace distribution was utilized. In the lamb experiment, the objective was to detect increased respiratory-related chemosensitivity to O 2 and CO 2 induced by a drug, domperidone. Specifically, the separate influence of end-tidal PO 2 and PCO 2 on minute ventilation ( V ˙ E ) before and after administration of domperidone was analyzed. In the simulation, KDE detected increased coupling strength at the lowest SNR among the three methods. In the lamb experiment, D-V partitioning resulted in the statistically strongest increase in transfer entropy post-domperidone for P O 2 → V ˙ E . In addition, D-V partitioning was the only method that could detect an increase in transfer entropy for P C O 2 → V ˙ E , in agreement with experimental findings. Transfer entropy is capable of detecting directional coupling changes in non-linear biomedical time series analysis featuring a small number of observations and presence of outliers. The results of this study suggest that fixed-binning, even with ranking, is too primitive, and although there is no clear winner between KDE and D-V partitioning, the reader should note that KDE requires more computational time and extensive parameter selection than D-V partitioning. We hope this study provides a guideline for selection of an appropriate transfer entropy estimation method.


  • Model-based characterization of ventilatory stability using spontaneous breathing

    by Shamim Nemati, Bradley A. Edwards, Scott A. Sands, Philip J. Berger, Andrew Wellman, George C. Verghese, Atul Malhotra, James P. Butler

    Cyclic ventilatory instabilities are widely attributed to an increase in the sensitivity or loop gain of the chemoreflex feedback loop controlling ventilation. A major limitation in the conventional characterization of this feedback loop is the need for labor-intensive methodologies. To overcome this limitation, we developed a method based on trivariate autoregressive modeling using ventilation, end-tidal Pco2and Po2; this method provides for estimation of the overall “loop gain” of the respiratory control system and its components, chemoreflex gain and plant gain. Our method was applied to recordings of spontaneous breathing in 15 anesthetized, tracheostomized, newborn lambs before and after administration of domperidone (a dopamine D2-receptor antagonist that increases carotid body sensitivity). We quantified the known increase in hypoxic ventilatory sensitivity in response to domperidone; controller gain for O2increased from 0.06 (0.03, 0.09) l·min−1·mmHg−1to 0.09 (0.08, 0.13) l·min−1·mmHg−1; median (interquartile-range). We also report that domperidone increased the loop gain of the control system more than twofold [0.14 (0.12, 0.22) to 0.40 (0.15, 0.57)]. We observed no significant changes in CO2controller gain, or plant gains for O2and CO2. Furthermore, our estimate of the cycle duration of periodic breathing compared favorably with that observed experimentally [measured: 7.5 (7.2, 9.1) vs. predicted: 7.9 (7.0, 9.2) breaths]. Our results demonstrate that model-based analysis of spontaneous breathing can 1) characterize the dynamics of the respiratory control system, and 2) provide a simple tool for elucidating an individual's propensity for ventilatory instability, in turn allowing potential therapies to be directed at the underlying mechanisms.


  • Open Access

    Data Fusion for Improved Respiration Rate Estimation

    by Shamim Nemati, Atul Malhotra, Gari D. Clifford

    We present an application of a modified Kalman-Filter (KF) framework for data fusion to the estimation of respiratory rate from multiple physiological sources which is robust to background noise. A novel index of the underlying signal quality of respiratory signals is presented and then used to modify the noise covariance matrix of the KF which discounts the effect of noisy data. The signal quality index, together with the KF innovation sequence, is also used to weight multiple independent estimates of the respiratory rate from independent KFs. The approach is evaluated both on a realistic artificial ECG model (with real additive noise) and on real data taken from 30 subjects with overnight polysomnograms, containing ECG, respiration, and peripheral tonometry waveforms from which respiration rates were estimated. Results indicate that our automated voting system can out-perform any individual respiration rate estimation technique at all levels of noise and respiration rates exhibited in our data. We also demonstrate that even the addition of a noisier extra signal leads to an improved estimate using our framework. Moreover, our simulations demonstrate that different ECG respiration extraction techniques have different error profiles with respect to the respiration rate, and therefore a respiration rate-related modification of any fusion algorithm may be appropriate.


  • A Nonparametric Surrogate-Based Test of Significance for T-Wave Alternans Detection

    by Shamim Nemati, Omar Abdala, Violeta Monasterio, Susie Yim-Yeh, Atul Malhotra, Gari D. Clifford

    We present a nonparametric adaptive surrogate test that allows for the differentiation of statistically significant T-wave alternans (TWA) from alternating patterns that can be solely explained by the statistics of noise. The proposed test is based on estimating the distribution of noise-induced alternating patterns in a beat sequence from a set of surrogate data derived from repeated reshuffling of the original beat sequence. Thus, in assessing the significance of the observed alternating patterns in the data, no assumptions are made about the underlying noise distribution. In addition, since the distribution of noise-induced alternans magnitudes is calculated separately for each sequence of beats within the analysis window, the method is robust to data nonstationarities in both noise and TWA. The proposed surrogate method for rejecting noise was compared to the standard noise-rejection methods used with the spectral method (SM) and the modified moving average (MMA) techniques. Using a previously described realistic multilead model of TWA and real physiological noise, we demonstrate the proposed approach that reduces false TWA detections while maintaining a lower missed TWA detection, compared with all the other methods tested. A simple averaging-based TWA estimation algorithm was coupled with the surrogate significance testing and was evaluated on three public databases: the Normal Sinus Rhythm Database, the Chronic Heart Failure Database, and the Sudden Cardiac Death Database. Differences in TWA amplitudes between each database were evaluated at matched heart rate (HR) intervals from 40 to 120 beats per minute (BPM). Using the two-sample Kolmogorov-Smirnov test, we found that significant differences in TWA levels exist between each patient group at all decades of HRs. The most-marked difference was generally found at higher HRs, and the new technique resulted in a larger margin of separability between patient populations than when the SM or MMA were applied to the same data.


  • An artificial vector model for generating abnormal electrocardiographic rhythms

    by Gari D Clifford, Shamim Nemati, Reza Sameni

    We present generalizations of our previously published artificial models for generating multi-channel ECG to provide simulations of abnormal cardiac rhythms. Using a three-dimensional vectorcardiogram (VCG) formulation, we generate the normal cardiac dipole for a patient using a sum of Gaussian kernels, fitted to real VCG recordings. Abnormal beats are specified either as perturbations to the normal dipole or as new dipole trajectories. Switching between normal and abnormal beat types is achieved using a first-order Markov chain. Probability transitions can be learned from real data or modeled by coupling to heart rate and sympathovagal balance. Natural morphology changes from beat-to-beat are incorporated by varying the angular frequency of the dipole as a function of the inter-beat (RR) interval. The RR interval time series is generated using our previously described model whereby time- and frequency-domain heart rate (HR) and heart rate variability characteristics can be specified. QT-HR hysteresis is simulated by coupling the Gaussian kernels associated with the T-wave in the model with a nonlinear factor related to the local HR (determined from the last n RR intervals). Morphology changes due to respiration are simulated by introducing a rotation matrix couple to the respiratory frequency. We demonstrate an example of the use of this model by simulating HR-dependent T-wave alternans (TWA) with and without phase-switching due to ectopy. Application of our model also reveals previously unreported effects of common TWA estimation methods.