GCGregory A. Clark

Gregory A. Clark

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gregory A. Clark has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhancing neuroprosthesis calibration: the advantage of integrating prior training over exclusive use of new data

    by Caleb J Thomson, Troy N Tully, Eric S Stone, Christian B Morrell, Erik J Scheme, David J Warren, Douglas T Hutchinson, Gregory A Clark, Jacob A George

    Objective. Neuroprostheses typically operate under supervised learning, in which a machine-learning algorithm is trained to correlate neural or myoelectric activity with an individual’s motor intent. Due to the stochastic nature of neuromyoelectric signals, algorithm performance decays over time. This decay is accelerated when attempting to regress proportional control of multiple joints in parallel, compared with the more typical classification-based pattern recognition control. To overcome this degradation, neuroprostheses and commercial myoelectric prostheses are often recalibrated and retrained frequently so that only the most recent, up-to-date data influences the algorithm performance. Here, we introduce and validate an alternative training paradigm in which training data from past calibrations is aggregated and reused in future calibrations for regression control. Approach. Using a cohort of four transradial amputees implanted with intramuscular electromyographic recording leads, we demonstrate that aggregating prior datasets improves prosthetic regression-based control in offline analyses and an online human-in-the-loop task. In offline analyses, we compared the performance of a convolutional neural network (CNN) and a modified Kalman filter (MKF) to simultaneously regress the kinematics of an eight-degree-of-freedom prosthesis. Both algorithms were trained under the traditional paradigm using a single dataset, as well as under the new paradigm using aggregated datasets from the past five or ten trainings. Main results. Dataset aggregation reduced the root-mean-squared error (RMSE) of algorithm estimates for both the CNN and MKF, although the CNN saw a greater reduction in error. Further offline analyses revealed that dataset aggregation improved CNN robustness when reusing the same algorithm on subsequent test days, as indicated by a smaller increase in RMSE per day. Finally, data from an online virtual-target-touching task with one amputee showed significantly better real-time prosthetic control when using aggregated training data from just two prior datasets. Significance. Altogether, these results demonstrate that training data from past calibrations should not be discarded but, rather, should be reused in an aggregated training dataset such that the increased amount and diversity of data improve algorithm performance. More broadly, this work supports a paradigm shift for the field of neuroprostheses away from daily data recalibration for linear classification models and towards daily data aggregation for non-linear regression models.


  • Open Access

    Validity and Impact of Methods for Collecting Training Data for Myoelectric Prosthetic Control Algorithms

    by Troy N. Tully, Caleb J. Thomson, Gregory A. Clark, Jacob A. George

    Intuitive regression control of prostheses relies on training algorithms to correlate biological recordings to motor intent. The quality of the training dataset is critical to run-time regression performance, but accurately labeling intended hand kinematics after hand amputation is challenging. In this study, we quantified the accuracy and precision of labeling hand kinematics using two common training paradigms: 1) mimic training, where participants mimic predetermined motions of a prosthesis, and 2) mirror training, where participants mirror their contralateral intact hand during synchronized bilateral movements. We first explored this question in healthy non-amputee individuals where the ground-truth kinematics could be readily determined using motion capture. Kinematic data showed that mimic training fails to account for biomechanical coupling and temporal changes in hand posture. Additionally, mirror training exhibited significantly higher accuracy and precision in labeling hand kinematics. These findings suggest that the mirror training approach generates a more faithful, albeit more complex, dataset. Accordingly, mirror training resulted in significantly better offline regression performance when using a large amount of training data and a non-linear neural network. Next, we explored these different training paradigms online, with a cohort of unilateral transradial amputees actively controlling a prosthesis in real-time to complete a functional task. Overall, we found that mirror training resulted in significantly faster task completion speeds and similar subjective workload. These results demonstrate that mirror training can potentially provide more dexterous control through the utilization of task-specific, user-selected training data. Consequently, these findings serve as a valuable guide for the next generation of myoelectric and neuroprostheses leveraging machine learning to provide more dexterous and intuitive control.


  • A Recurrent Neural Network Provides Stable Across-Day Prosthetic Control for a Human Amputee with Implanted Intramuscular Electromyographic Recording Leads

    by Caleb J. Thomson, Gregory A. Clark, Jacob A. George

    Upper-limb prosthetic control is often challenging and non-intuitive, leading to up to 50% of prostheses users abandoning their prostheses. Convolutional neural networks (CNN) and recurrent long short-term memory (LSTM) networks have shown promise in extracting high-degree-of-freedom motor intent from myoelectric signals, thereby providing more intuitive and dexterous prosthetic control. An important next consideration for these algorithms is if performance remains stable over multiple days. Here we introduce a new LSTM network and compare its performance to previously established state-of-the-art algorithms–a CNN and a modified Kalman filter (MKF)–in offline analyses using 76 days of intramuscular recordings from one amputee participant collected over 425 calendar days. Specifically, we assessed the robustness of each algorithm over time by training on data from the first (one, five, ten, 30, or 60) days and then testing on myoelectric signals on the last 16 days. Results indicate that training on additional datasets from prior days generally decreases the Root Mean Squared Error (RMSE) of intended and unintended movements for all algorithms. Across all algorithms trained with 60 days of data, the lowest RMSE for unintended movements was achieved with the LSTM. The LSTM also showed less across-day variance in RMSE of unintended movements relative to the other algorithms. Altogether this work suggests that the LSTM algorithm introduced here can provide more intuitive and dexterous control for prosthetic users, and that training on multiple days of data improves overall performance on subsequent days, at least for offline analyses.


  • Open Access

    Discriminability of multiple cutaneous and proprioceptive hand percepts evoked by intraneural stimulation with Utah slanted electrode arrays in human amputees

    by David M. Page, Jacob A. George, Suzanne M. Wendelken, Tyler S. Davis, David T. Kluger, Douglas T. Hutchinson, Gregory A. Clark

    Background: Electrical stimulation of residual afferent nerve fibers can evoke sensations from a missing limb after amputation, and bionic arms endowed with artificial sensory feedback have been shown to confer functional and psychological benefits. Here we explore the extent to which artificial sensations can be discriminated based on location, quality, and intensity. Methods: We implanted Utah Slanted Electrode Arrays (USEAs) in the arm nerves of three transradial amputees and delivered electrical stimulation via different electrodes and frequencies to produce sensations on the missing hand with various locations, qualities, and intensities. Participants performed blind discrimination trials to discriminate among these artificial sensations. Results: Participants successfully discriminated cutaneous and proprioceptive sensations ranging in location, quality and intensity. Performance was significantly greater than chance for all discrimination tasks, including discrimination among up to ten different cutaneous location-intensity combinations (15/30 successes, p < 0.0001) and seven different proprioceptive location-intensity combinations (21/40 successes, p < 0.0001). Variations in the site of stimulation within the nerve, via electrode selection, enabled discrimination among up to five locations and qualities (35/35 successes, p < 0.0001). Variations in the stimulation frequency enabled discrimination among four different intensities at the same location (13/20 successes, p < 0.0005). One participant also discriminated among individual stimulation of two different USEA electrodes, simultaneous stimulation on both electrodes, and interleaved stimulation on both electrodes (20/24 successes, p < 0.0001). Conclusion: Electrode location, stimulation frequency, and stimulation pattern can be modulated to evoke functionally discriminable sensations with a range of locations, qualities, and intensities. This rich source of artificial sensory feedback may enhance functional performance and embodiment of bionic arms endowed with a sense of touch.


  • Que sait une population suisse fragilisée de la bronchopneumopathie chronique obstructive ?

    by Gregory Clark, Dominique Monnin, Marc Marechal

    La bronchopneumopathie chronique obstructive (BPCO) atteint près de 400 000 personnes en Suisse. Elle reste sous-diagnostiquée et les patients la connai...

  • Open Access

    Activities of Daily Living with Bionic Arm Improved by Combination Training and Latching Filter in Prosthesis Control Comparison

    by Michael D. Paskett, Mark R. Brinton, Taylor C. Hansen, Jacob A. George, Tyler S. Davis, Christopher C. Duncan, Gregory A. Clark

    Background Advanced prostheses can restore function and improve quality of life for individuals with amputations. Unfortunately, most commercial control strategies do not utilize the rich control information from residual nerves and musculature. Continuous decoders can provide more intuitive prosthesis control from multi-channel neural or electromyographic recordings. Three components influence continuous decoder performance: the data used to train the algorithm, the algorithm, and smoothing filters on the algorithm’s output. As individual groups often focus on a single decoder, very few studies compare different decoders using otherwise similar experimental conditions. Additionally, control improvements are generally demonstrated with offline data or in virtual settings, which do not necessarily translate to real-world performance. Methods We completed a two-phase head-to-head comparison of 12 continuous decoders using activities of daily living. In phase one, we compared two training types and a smoothing filter with three algorithms (modified Kalman filter, multi-layer perceptron, and convolutional neural network) in a clothespin relocation task. We compared training types that included data with only individual digit and wrist movements vs. combination movements (e.g., simultaneous grasp and wrist flexion). We also compared raw vs. nonlinearly smoothed algorithm outputs. In phase two, we compared the three algorithms in fragile egg, zipping, pouring, and folding tasks using the combination training and smoothing found beneficial in phase one. In both phases, we collected objective, performance-based (e.g., success rate) and subjective, user-focused (e.g., preference) measures. Results Phase one showed that combination training improved prosthesis control accuracy and speed, and that the nonlinear smoothing improved accuracy but generally reduced speed. In phase two, user-focused metrics favored the convolutional neural network and modified Kalman filter, while performance-based metrics were generally similar among all algorithms. Conclusions These results confirm that state-of-the-art algorithms, whether linear or nonlinear in nature, functionally benefit from training on more complex data, and demonstrate that smoothing the output improves control. These studies will be used to select a decoder for a long-term take-home trial with implanted neuromyoelectric devices. Overall, clinical considerations may favor the mKF as it is similar in performance, faster to train, and computationally less expensive than neural networks.

  • Open Access

    Intuitive neuromyoelectric control of a dexterous bionic arm using a modified Kalman filter

    by Jacob A. George, Tyler S. Davis, Mark R. Brinton, Gregory A. Clark


  • Open Access

    An Adaptable Prosthetic Wrist Reduces Subjective Workload

    by Nathaniel R. Olsen, Jacob A. George, Mark R. Brinton, Michael D. Paskett, David T. Kluger, Troy N. Tully, Christopher C. Duncan, Gregory A. Clark

    Many presently available prostheses lack a functional wrist. To fill this niche and to better understand the impact a wrist has in prosthetic functionality, we designed a low-cost, adaptable, 3D-printable prosthetic wrist that can be adapted to various prosthetic hands and sockets. The wrist utilizes inexpensive but powerful servo motors to provide simultaneous and proportional control of two degrees of freedom: pronation/supination and flexion/extension or radial/ulnar deviation. Participants used both our wrist and a commercially available wrist (DEKA “LUKE” Arm) to complete a modified version of the clothespin relocation task with and without the wrists enabled. Through use of the NASA Task Load Index we found that both wrists significantly reduced the subjective workload associated with clothespin relocation task ( p < 0.05). However, we found no significant difference in task completion speed, presumably due to compensation strategies. This inexpensive and adaptable prosthetic wrist can be used by amputees to reduce task workload, or by researchers to further explore the importance of wrist function.


  • Open Access

    Intuitive Neuromyoelectric Control of a Dexterous Bionic Arm Using a Modified Kalman Filter

    by Jacob A. George, Tyler S. Davis, Mark R. Brinton, Gregory A. Clark

    Background: Multi-articulate prostheses are capable of performing dexterous hand movements. However, clinically available control strategies fail to provide users with intuitive, independent and proportional control over multiple degrees of freedom (DOFs) in real-time. New Method: We detail the use of a modified Kalman filter (MKF) to provide intuitive, independent and proportional control over six-DOF prostheses such as the DEKA "LUKE" Arm. Input features include neural firing rates recorded from Utah Slanted Electrode Arrays and mean absolute value of intramuscular electromyographic (EMG) recordings. Ad-hoc modifications include thresholds and non-unity gains on the output of a Kalman filter. Results: We demonstrate that both neural and EMG data can be combined effectively. We also highlight that modifications can be optimized to significantly improve performance relative to an unmodified Kalman filter. Thresholds significantly reduced unintended movement and promoted more independent control of the different DOFs. Gain were significantly greater than one and served to amplify participant effort. Optimal modifications can be determined quickly offline and translate to functional improvements online. Using a portable take-home system, participants performed various activities of daily living. Comparison with Existing Methods: In contrast to pattern recognition, the MKF allows users to continuously modulate their force output, which is critical for fine dexterity. The MKF is also computationally efficient and can be trained in less than five minutes. Conclusions: The MKF can be used to explore the functional and psychological benefits associated with long-term, at-home control of dexterous prosthetic hands.

  • Top Cited Papers

    Biomimetic sensory feedback through peripheral nerve stimulation improves dexterous use of a bionic hand

    by J. A. George, D. T. Kluger, T. S. Davis, S. M. Wendelken, E. V. Okorokova, Q. He, C. C. Duncan, D. T. Hutchinson, Z. C. Thumser, D. T. Beckler, et al.

    Sensory feedback improves dexterous use of a bionic arm, and sensory signals that mimic natural ones are more intuitive and useful.