JGJacob A. George

Jacob A. George

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jacob A. George has a total of 136 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intensity Discrimination of Electrocutaneous Haptic Feedback Is Enhanced at Low Frequencies and with Repeated Exposure

    by A.R. Citterman, R.J. Urban, L.M. Nygard, A.E. Stewart, M. Teramoto, M.R. Brinton, J.A. George

    Electrocutaneous (EC) stimulation is a promising modality for noninvasive tactile feedback. Increasing the pulse frequency of EC stimulation has been shown to increase the perceived intensity in a nonlinear way. However, it is unclear why the relationship is nonlinear and how the nonlinearity impacts the theoretical number of discriminable sensory gradations that can be evoked by EC stimulation, as would be necessary to effectively convey the magnitude of tactile interactions. To address this, we systematically quantify just-noticeable differences (JNDs) and corresponding Weber fractions (WFs) through three psychophysical experiments in healthy adults to elucidate the perceptual resolution and mechanisms for frequency-based sensory encoding. First, we quantify the JNDs and WFs at 25-, 50-, 75-, and 100-Hz reference points and provide quantitative data supporting prior work that suggested intensity discrimination is worse at higher pulse frequencies. Second, we demonstrate that perceptual learning is frequency dependent; intensity discrimination at 50 Hz improved with greater exposure through additional JND experiments, whereas no improvement was observed with repeated exposure at 100 Hz. Third, by isolating frequency discrimination from intensity cues using pseudo-randomized pulse amplitudes, we show that temporal discrimination is impossible at higher frequencies. This suggests that temporal cues present at lower EC pulse frequencies contribute to enhanced perceptual sensitivity at lower frequencies. These findings serve as a quantitative benchmark for intensity discrimination across the working range of EC pulse frequencies, and provide new evidence that enhanced perceptual sensitivity at lower frequencies is likely due to the learnability of supplemental temporal cues. These findings highlight the importance of documenting the experience level of participants when reporting discriminability and may be used to optimize EC haptic feedback systems.

  • Open Access

    The Electronic Grip Gauge (EGG): Automated Assessment of Sensorimotor Hand Function Using an Instrumented Fragile Object

    by Michael D. Adkins, Tyler J. Gourley, Tyler S. Davis, Nate Toth, Monika K. Buczak, Masaru Teramoto, Steven R. Edgley, Lorie G. Richards, Marta M. Iversen, Jacob A. George

    Hand dexterity assessments play a crucial role in informing the rehabilitative care of individuals with upper-limb hemiparesis. However, current assessments often struggle to evaluate the hand's ability to precisely control grip force, a skill vital for daily activities like handling fragile objects. Here we describe the design of the Electronic Grip Gauge (EGG), an adjustable-weight, instrumented “fragile” object that measures grip force, load force, acceleration, orientation, and relative position. Embedded sensors enable automatic segmentation and analysis of EGG transfers in various modes. In “Non-Fragile” mode, there is no break threshold; the EGG serves as an automated variant of the Box-and-Blocks test. In “Fragile” mode, the EGG simulates fragility by playing a “break” noise if grip force exceeds a set threshold, requiring grip control to prevent breaks. In “Fragile-Feedback” mode, audio-visual feedback is provided proportional to applied grip force to supplement potentially impaired tactile feedback. Demonstrating functionality, we evaluated sensorimotor differences between 26 hemiparetic and 26 age-matched healthy participants. In “Fragile” mode, paretic hands were significantly slower, applied excessive force, and broke the EGG more frequently than contralateral and healthy control hands. In “Fragile-Feedback” mode, a subset of paretic hands improved, transferring the EGG faster and/or with less force. This work demonstrates the EGG's utility in automatically quantifying sensorimotor deficits and that, for a subset of hemiparetic patients, audiovisual feedback could potentially coach and rehabilitate hand function. Collectively, this work showcases the EGG's potential as both an assessment and rehabilitation device for grip force control – a critical skill in hand therapy.

  • Open Access

    An Intuitive, Bidirectional, and Adaptive Functional Electrical Stimulation System for Hand Rehabilitation

    by Marshall A. Trout, Clay T. Stanley, Kristen M. Saad, Abigail T. Harrison, Mingxi Liu, Jacob A. George

    After a neuromotor injury, such as a stroke or spinal cord injury, patients are faced with decreased independence and quality of life due to limited hand function. Functional electrical stimulation (FES) therapy can improve patients’ recovery. However, this technology is underutilized in clinics due to complex and long setup times, and there is a distinct lack of commercially available FES systems for hand therapy. In this work, we present a closed-loop, bidirectional FES system specifically designed for grasping rehabilitation. The proposed FES system leverages a first-order, adapting local model of muscle activation dynamics to control grip force by modulating the FES amplitude. We demonstrate with 12 healthy participants that the adaptive controller provides more accurate control than an autotuned PID controller. We also validate that the FES system works with a C5 spinal cord injury (SCI) participant exhibiting a typical upper motor neuron pattern of spasticity. Each participant also completed a longer-duration fatiguing experiment, and we observed that not only does the controller adapt to accurately control contractions as the activated muscles fatigue, but the model parameters are strongly correlated with fatigue and could be used to measure fatigue in real time. Finally, we show that a previously untrained user can set up the FES system in under 5 minutes. These results demonstrate the benefits of using adaptive models for FES control and can be used as a guide to design effective, translatable FES systems.


  • Open Access

    Preliminary Investigation of Myoelectric Control of an Assistive Neck Exoskeleton by Individuals With Amyotrophic Lateral Sclerosis

    by Monika K. Buczak, Joseph Brignone, W. Caden Hamrick, Kiley M. Cole, Mark B. Bromberg, Haohan Zhang, Jacob A. George

    Neck weakness limits head control and quality of life for individuals with Amyotrophic Lateral Sclerosis (ALS). The Utah Neck Exoskeleton can restore neck motion, but current control methods-joystick and gaze tracking-have limited accessibility and reliability. These preliminary offline analyses investigate neck electromyography (EMG) as an alternative control modality from ALS patients. EMG signals were recorded from four male participants with ALS while performing neck flexion/extension, axial rotation, and lateral deviation. The resulting dataset was used to train convolutional neural networks (CNNs) per patient to classify either head position or movement direction from EMG features offline. Position classification significantly outperformed direction classification, with a mean accuracy of 82.5% ± 0.010 across participants. Performance was consistent when controlling one, two, or all three neck degrees of freedom. A subset of participants with sufficient residual motor function also completed neck movements while talking or chewing. Classification accuracy decreased during talking and chewing, although these effects were not statistically significant. Importantly however, training CNNs with diverse data that included periods of talking and chewing improved algorithm robustness across all conditions. These findings suggest that neck EMG signals can reliably predict intended head movements in ALS, even in the presence of weak and often confounding muscle activity. Offline accuracy and real-time computational speed suggest the approach is feasible for future online user-in-the-loop studies. Altogether, this pilot work advances EMG-based assistive technology for individuals with severe motor impairments, laying the groundwork for clinically viable, intuitive control systems.

  • Open Access

    Shared human-machine control of an intelligent bionic hand improves grasping and decreases cognitive burden for transradial amputees

    by Marshall A. Trout, Fredi R. Mino, Connor D. Olsen, Taylor C. Hansen, Masaru Teramoto, David J. Warren, Jacob L. Segil, Jacob A. George

    Bionic hands can replicate many movements of the human hand, but our ability to intuitively control these bionic hands is limited. Humans' manual dexterity is partly due to control loops driven by sensory feedback. Here, we describe the integration of proximity and pressure sensors into a commercial prosthesis to enable autonomous grasping and show that continuously sharing control between the autonomous hand and the user improves dexterity and user experience. Artificial intelligence moved each finger to the point of contact while the user controlled the grasp with surface electromyography. A bioinspired dynamically weighted sum merged machine and user intent. Shared control resulted in greater grip security, greater grip precision, and less cognitive burden. Demonstrations include intact and amputee participants using the modified prosthesis to perform real-world tasks with different grip patterns. Thus, granting some autonomy to bionic hands presents a translatable and generalizable approach towards more dexterous and intuitive control.


  • Open Access

    Training Movement Velocity Significantly Affects the Performance of Myoelectric Control

    by Troy N. Tully, Amelia E. Nelson, Jacob A. George

    Our native hands are uniquely capable of operating across a wide range of speeds and forces. In contrast, most commercial myoelectric prostheses typically provide limited speed and force output. One approach to endow myoelectric prostheses with variable speed and/or force output is to use continuous kinematic positions of the prosthesis based on electromyography (EMG). Within the field of machine learning, it is well established that homogeneous training data can lead to bias that negatively impacts the run-time performance of the algorithm. Yet, most continuous decoders are trained on a homogeneous dataset involving only a single kinematic speed. To this end, we systematically investigated how different training speeds influence myoelectric control with two common continuous decoders on multiple performance metrics. We compared a Kalman filter (KF) and Convolutional Long Short-Term Memory (C-LSTM) neural network trained on slow, medium, fast, and mixed-speed datasets, evaluating their performance in offline analyses and in two real-time online tasks with the user actively in the loop. We found that training speed significantly affected algorithm performance, but effects were often algorithm dependent. Linear algorithms, like the KF, are likely to exhibit lower unintended movement errors and smoother control when trained on slow-speed data but will also struggle to generalize to higher movement speeds. In contrast, nonlinear algorithms like the C-LSTM can likely provide greater adaptability, with mixed-speed training leading to improved accuracy and task success rates across conditions. Although an often-overlooked implicit parameter, these findings explicitly demonstrate that a lack of diverse training speeds in existing myoelectric control training paradigms leads to worse decoder performance. By incorporating a range of movement speeds into training protocols or decoder design, myoelectric continuous decoders could achieve more dexterous and robust control, potentially improving prosthetic usability and retention.


  • Open Access

    Improved Prediction of Activities of Daily Living from Wrist Electromyography Using Intermediate Gesture Classification

    by W. Caden Hamrick, Tyler J. King, Connor D. Olsen, Amelia E. Nelson, Melissa Mauchley, Bethany C. Curd, Christine Cliatt Brown, Nicholas A. Frost, Marta M. Iversen, Jacob A. George

    The long-term goal of this research is to automatically, remotely, and noninvasively identify Activities of Daily Living (ADLs) using muscle activity at the wrist. Alzheimer’s Dementia is a widespread condition affecting patients’ memory and ability to care for themselves. A wrist-worn device capable of monitoring precise ADLs could increase patient independence and provide caretakers with detailed information regarding the patient’s wellbeing. Here, we investigate the use of an intermediate hand gesture classifying algorithm to predict ADLs using wrist electromyography (EMG). We show that predicted gestures are well-represented within the span of ADLs, and that the repertoire of predicted gestures appears distinct among ADLs. Importantly, we show that a simple linear discriminant analysis of predicted gestures provides better and more efficient classification accuracy relative to a state-of-the-art neural network that predicts ADLs directly from EMG. Accurate and efficient classification of ADLs from a wrist-worn device can provide a foundation for remote monitoring of patients in a socially acceptable formfactor. More broadly, a better understanding of human behavior via ADL tracking can enable new assistive technologies that improve quality of life.Clinical Relevance—Monitoring activities of daily living with an electromyographic smart watch can provide insights into patient behavior and wellbeing.

  • Open Access

    Multi-Channel Functional Electrical Stimulation to Improve Specificity of Hand Extension

    by Clay T. Stanley, Marshall A. Trout, Kristen M. Saad, Fredi R. Mino, Amelia E. Nelson, Troy N. Tully, Tyler S. Davis, Jacob A. George

    The long-term goal of this research is to improve the functionality of non-invasive transcutaneous functional electrical stimulation (FES) by improving specificity in upper extremity paralysis. Spinal cord injuries result in an estimated 10,000 new cases of upper extremity paralysis yearly. FES has been used extensively to assist and rehabilitate individuals with lower-limb paralysis, but it has not been widely adopted for upper-limb paralysis. This is in part due to the complex setup necessary to target the right combination of small muscles densely packed in the forearm to create a desired hand gesture. To address this challenge, here we introduce a new multichannel FES system that enables complex current steering with a high compliance voltage to selectively recruit small extrinsic hand muscles in isolation or in combination. Using this system with real-time motion capture data of the hand, we stimulated unique electrode configurations each second to rapidly identify a rich repertoire of hand gestures. Additionally, as an initial demonstration of the unique current steering capabilities, we show that FES involving three active electrodes, instead of the traditional 2-electrode setup, provides greater specificity and redundancy, which in turn could support more therapeutic motions and interleaved stimulation to reduce fatigue Thus, this work constitutes an important step towards more efficient, dexterous, and robust upper-limb FES to improve neurorehabilitation outcomes for people with spinal cord injuries.Clinical Relevance— A new multichannel FES system can rapidly configure FES stimulation to evoke a variety of single-digit and multi-digit hand gestures.

  • Open Access

    Quantifying the Cognitive Demand of Controlling a Prosthesis with a Secondary Detection Response Task

    by Mingchuan Cheng, Connor D. Olsen, Masaru Teramoto, Marta M. Iversen, Jacob A. George

    Up to 44% of upper-limb amputees abandon their prosthesis due to difficulty with control. More intuitive control is needed, but innovation is difficult without a valid and reliable way to measure intuitiveness. Here, we validate a secondary detection-response task (DRT) as a method to objectively measure the cognitive load of using a prosthesis. The DRT is a simple, yet sensitive measure of cognitive resource allocation based on response rate and reaction time to vibratory stimuli. Participants completed a primary task involving moving objects with varying fragility over a barrier without breaking them with their intact hand and with a prosthetic hand controlled by electromyography. While completing the primary task, participants also completed the secondary DRT in which they responded to randomly delivered vibratory stimuli as quickly as possible by pushing a button with their contralateral limb. Participants also completed the NASA Task Load Index, a survey commonly used to assess subjective workload. Results showed that response time and rate were reliable indicators of cognitive load, suggesting that the DRT can objectively measure cognitive load in prosthesis use, thereby guiding future innovation for more intuitive prosthetic control.Clinical Relevance— This research establishes the use of a secondary detection response task as a valid and reliable assessment of cognitive load during prosthesis use.


  • Open Access

    Functional and Structural Neural Plasticity Following sEMG Control of a Virtual Prosthetic Hand in an Individual with Bilateral Upper-Limb Congenital Amputation

    by Daniel A. Feldman, Davi F. Cavinatto, Connor D. Olsen, W. Caden Hamrick, Michael D. Paskett, Tyler S. Davis, Chris Baschuk, Chris C. Duncan, Jace B. King, Gregory A. Clark, et al.

    Here we document cortical neural connectivity changes associated with several weeks of prosthetic use in an individual with bilateral upper-limb congenital amputation. Secondly, we explore how those changes relate to prosthetic performance over time. Previous research in unilateral aplasia has shown that functional brain connectivity and activations can be disrupted in the missing hand area, and that prosthetic use can normalize those abnormalities. Functional connectivity and prosthetic use related brain changes in individuals with bilateral congenital upper limb amputations have not been defined. Here, we describe functional and structural connectivity changes measured with MRI after 10-weeks’ unilateral use of an sEMG-controlled virtual prosthetic in an individual with aplasia born without either arm. We find that both functional connectivity and structural connectivity change with sEMG prosthetic use. Specifically, functional connectivity of motor regions tends to lateralize and become more hemisphere specific. Additionally, structural connectivity of motor cortico-spinal white matter projections and interhemispheric commissural projections increase after sEMG prosthetic use. These functional connectivity changes are different from those previously reported for one-handed congenital amputees, where prosthetic use normalized, not lateralized, imbalanced interhemispheric motor connectivity. Alongside these neural changes, sEMG virtual prosthetic performance both increased and decreased over time, depending on the action performed. Our results suggest that neural representations of bilateral congenital amputation and subsequent neural adaptions with unilateral prosthetic use may be distinct from those of unilateral congenital and traumatic upper-limb amputees. Consideration of condition-specific neurobiology may be critical in developing effective neuro-prostheses.Clinical Relevance— This describes the neural changes induced by sEMG prosthetic control in a congenital bilateral amputee.