Mohd Fahmi Mohd Yusof
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohd Fahmi Mohd Yusof has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Puteri Nor Khatijah Abd Hamid
School of Physics, Universiti Sains Malaysia, 11800 Penang, Malaysia
4 shared publications- Rokiah Hashim
Universiti Sains Malaysia
4 shared publications Abd Aziz Tajuddin
Univ Sains Malaysia, Sch Phys, George Town 11800, Malaysia
3 shared publications- Mohd Zahri Abdul Aziz
Advanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia
3 shared publications Rokiah Hashim
3 shared publicationsA A Tajuddin
School of Physics, Universiti Sains Malaysia, 11800 Penang, Malaysia
2 shared publications
Latest Publications
- Open Access
Dosimetric Characterization of DSF/NaOH/IA-PAE/R. spp. Phantom Material for Radiation Therapy
Background: Different compositions of DSF/NaOH/IA-PAE/R. spp. composite particleboard phantoms were constructed. Methods: Photon attenuation characteristics were ascertained using gamma rays from 137Cs and 60Co. Absorbed doses at the location of an ionization chamber and Gafchromic EBT3 radiochromic films were calculated for high-energy photons (6 and 10 MV) and electrons (6, 9, 12, and 15 MeV). Results: The calculated TPR20,10 values indicate that the percentage discrepancy for 6 and 10 MV was in the range of 0.29–0.72% and 0.26–0.65%. It was also found that the relative difference in the to water and solid water phantoms was between 1.08–1.28% and 5.42–6.70%. The discrepancies in the determination of PDD curves with 6, 9, 12, and 15 MeV, and those of water and solid water phantoms, ranged from 2.40–4.84%. Comparable results were found using the EBT3 films with variations of 2.0–7.0% for 6 and 10 MV photons. Likewise, the discrepancies for 6, 9, 12, and 15 MeV electrons were within an acceptable range of 2.0–4.5%. Conclusions: On the basis of these findings, the DSF/NaOH/IA-PAE/R. spp. particleboard phantoms with 15 wt% IA-PAE addition level can be effectively used as alternative tissue-equivalent phantom material for radiation therapy applications.Open AccessDosimetric Characterization of DSF/NaOH/IA-PAE/R. spp. Phantom Material for Radiation Therapy
Background: Different compositions of DSF/NaOH/IA-PAE/R. spp. composite particleboard phantoms were constructed. Methods: Photon attenuation characteristics were ascertained using gamma rays from 137Cs and 60Co. Absorbed doses at the location of an ionization chamber and Gafchromic EBT3 radiochromic films were calculated for high-energy photons (6 and 10 MV) and electrons (6, 9, 12, and 15 MeV). Results: The calculated TPR20,10 values indicate that the percentage discrepancy for 6 and 10 MV was in the range of 0.29–0.72% and 0.26–0.65%. It was also found that the relative difference in the to water and solid water phantoms was between 1.08–1.28% and 5.42–6.70%. The discrepancies in the determination of PDD curves with 6, 9, 12, and 15 MeV, and those of water and solid water phantoms, ranged from 2.40–4.84%. Comparable results were found using the EBT3 films with variations of 2.0–7.0% for 6 and 10 MV photons. Likewise, the discrepancies for 6, 9, 12, and 15 MeV electrons were within an acceptable range of 2.0–4.5%. Conclusions: On the basis of these findings, the DSF/NaOH/IA-PAE/R. spp. particleboard phantoms with 15 wt% IA-PAE addition level can be effectively used as alternative tissue-equivalent phantom material for radiation therapy applications. - Open Access
- 1 February 2022
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1231 (1) , 012018
Small beam dosimetry by using Al2O3 optically stimulated luminescent (OSL) dosimeters at high energy photons and electrons
The study focused on the measurements of depth dose for small beam in the high energy photons and electrons. The percentage depth dose (PDD) was measured in 6 and 10 MV photons and 9 and 12 MeV electrons at 3 × 3 cm field sizes by using the Al2O3 optically stimulated luminescent (OSL) dosimeters. The PDD in OSL dosimeters were compared to those in ionization chamber and Gafchromic EBT3 film dosimeter. The results showed that the PDD in OSL dosimeters in lower photon and electron energies were in good agreement within 4% to ionization chamber and film. The PDD in 10 MV photons however showed gradual increase of deviation up to 10% beyond the depth of maximum dose (dmax). The surface doses in OSL dosimeters were significantly higher compared to those in ionization chamber and film dosimeter. The overall results suggested the suitability of OSL dosimeters to be used as indirect dosimetry works in high energy photons and electrons.
- 1 February 2022
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1231 (1) , 012018
Open AccessSmall beam dosimetry by using Al2O3 optically stimulated luminescent (OSL) dosimeters at high energy photons and electrons
The study focused on the measurements of depth dose for small beam in the high energy photons and electrons. The percentage depth dose (PDD) was measured in 6 and 10 MV photons and 9 and 12 MeV electrons at 3 × 3 cm field sizes by using the Al2O3 optically stimulated luminescent (OSL) dosimeters. The PDD in OSL dosimeters were compared to those in ionization chamber and Gafchromic EBT3 film dosimeter. The results showed that the PDD in OSL dosimeters in lower photon and electron energies were in good agreement within 4% to ionization chamber and film. The PDD in 10 MV photons however showed gradual increase of deviation up to 10% beyond the depth of maximum dose (dmax). The surface doses in OSL dosimeters were significantly higher compared to those in ionization chamber and film dosimeter. The overall results suggested the suitability of OSL dosimeters to be used as indirect dosimetry works in high energy photons and electrons.
- Open Access
- 1 February 2022
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1231 (1) , 012008
Physical properties of polyvinyl alcohol (PVAL) gel materials as phantoms for mammography
This study evaluates the possibility of using polyvinyl alcohol (PVAL) composites as phantom material to simulate different densities of breast tissue for mammography based on their elastic properties. Three categories of PVAL gels were prepared by freezing and thawing 10 % water based PVAL (PVAL), ethanol and water based PVAL (PVAL/E) and a blend of PVAL with graphite powder (PVAL/G) solutions to mimic various breast densities. Young’s modulus (YM) of all samples was evaluated by puncture test using the texture analyser. The results recorded ranged from 0.93 to 4.79 kPa for all samples. The results indicate that the PVAL based phantoms examined could be used to simulate fatty and dense breast tissues based on the values of their densities and YM.
- 1 February 2022
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1231 (1) , 012008
Open AccessPhysical properties of polyvinyl alcohol (PVAL) gel materials as phantoms for mammography
This study evaluates the possibility of using polyvinyl alcohol (PVAL) composites as phantom material to simulate different densities of breast tissue for mammography based on their elastic properties. Three categories of PVAL gels were prepared by freezing and thawing 10 % water based PVAL (PVAL), ethanol and water based PVAL (PVAL/E) and a blend of PVAL with graphite powder (PVAL/G) solutions to mimic various breast densities. Young’s modulus (YM) of all samples was evaluated by puncture test using the texture analyser. The results recorded ranged from 0.93 to 4.79 kPa for all samples. The results indicate that the PVAL based phantoms examined could be used to simulate fatty and dense breast tissues based on the values of their densities and YM.
- 31 January 2022
- Published by Penerbit UMT, Universiti Malaysia Terengganu in Journal of Sustainability Science and Management
- Vol. 17 (1) , 236-258
INVESTIGATING THE GEOCHEMICAL CONTENT OF ANCIENT LATERITE BRICKS FROM BUKIT CHORAS ARCHAEOLOGICAL SITE USING X-RAY DIFFRACTION (XRD) AND X-RAY FLUORESCENCE (XRF)
- 31 January 2022
- Published by Penerbit UMT, Universiti Malaysia Terengganu in Journal of Sustainability Science and Management
- Vol. 17 (1) , 236-258
INVESTIGATING THE GEOCHEMICAL CONTENT OF ANCIENT LATERITE BRICKS FROM BUKIT CHORAS ARCHAEOLOGICAL SITE USING X-RAY DIFFRACTION (XRD) AND X-RAY FLUORESCENCE (XRF)
- 1 December 2021
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 189
Rhizophora spp. as potential phantom material in medical physics applications – A review
- 1 December 2021
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 189
Rhizophora spp. as potential phantom material in medical physics applications – A review
- Open Access
Influence of Different Percentages of Binders on the Physico-Mechanical Properties of Rhizophora spp. Particleboard as Natural-Based Tissue-Equivalent Phantom for Radiation Dosimetry Applications
Rhizophora spp. particleboard with the incorporation of lignin and soy flour as binders were fabricated and the influence of different percentages of lignin and soy flour (0%, 6% and 12%) on the physico-mechanical properties of the particleboard were studied. The samples were characterised by Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), X-ray fluorescence (XRF) and internal bonding. The results stipulated that the addition of binders in the fabrication of the particleboard did not change the functional groups according to the FTIR spectrum. For XRD, addition of binders did not reveal any major transformation within the composites. SEM and EDX analyses for all percentages of binders added showed no apparent disparity; however, it is important to note that the incorporation of binders allows better bonding between the molecules. In XRF analysis, lower percentage of chlorine in the adhesive-bonded samples may be advantageous in maintaining the natural properties of the particleboard. In internal bonding, increased internal bond strength in samples with binders may indicate better structural integrity and physico-mechanical strength. In conclusion, the incorporation of lignin and soy flour as binders may potentially strengthen and fortify the particleboard, thus, can be a reliable phantom in radiation dosimetry applications.
Open AccessInfluence of Different Percentages of Binders on the Physico-Mechanical Properties of Rhizophora spp. Particleboard as Natural-Based Tissue-Equivalent Phantom for Radiation Dosimetry Applications
Rhizophora spp. particleboard with the incorporation of lignin and soy flour as binders were fabricated and the influence of different percentages of lignin and soy flour (0%, 6% and 12%) on the physico-mechanical properties of the particleboard were studied. The samples were characterised by Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), X-ray fluorescence (XRF) and internal bonding. The results stipulated that the addition of binders in the fabrication of the particleboard did not change the functional groups according to the FTIR spectrum. For XRD, addition of binders did not reveal any major transformation within the composites. SEM and EDX analyses for all percentages of binders added showed no apparent disparity; however, it is important to note that the incorporation of binders allows better bonding between the molecules. In XRF analysis, lower percentage of chlorine in the adhesive-bonded samples may be advantageous in maintaining the natural properties of the particleboard. In internal bonding, increased internal bond strength in samples with binders may indicate better structural integrity and physico-mechanical strength. In conclusion, the incorporation of lignin and soy flour as binders may potentially strengthen and fortify the particleboard, thus, can be a reliable phantom in radiation dosimetry applications.
- 14 March 2021
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 32 (3) , 1-19
Low-energy X-ray attenuation characteristics of Rhizophora spp. composites
- 14 March 2021
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 32 (3) , 1-19
Low-energy X-ray attenuation characteristics of Rhizophora spp. composites
- Open Access
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1106 (1) , 012015
Evaluation of nuclear medicine planar images based on partial volume effects and recovery coefficients at different activity levels of radionuclides and matrix sizes
The partial volume effect evaluations had been effectively used as method for the evaluation of SPECT images in nuclear medicine. The study focused on the use of partial volume effect method and the evaluation of recovery coefficient in the 2D planar images in nuclear medicine. The planar images were obtained by using a modified Jaszczak phantom that contains radionuclide volume of differents diameter sizes and three activity levels. The planar images were also taken at three different matrix sizes of gamma camera set up at 128 x 128, 256 x 256 and 512 x 512. The results showed that the contrast values increased exponentially at larger diameter sizes of radionuclide. The contrast also significantly increased when higher matrix sizes were used. The recovery coefficient evaluation of the planar images were singnificantly decreased when larger matrix sizes were used. There were no significant differences between the recovery coefficients between planar images obtained with and without background counts. The overall results indicated the suitability of using the partical volume efffect method to evaluate the planar images of nuclear medicine.
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1106 (1) , 012015
Open AccessEvaluation of nuclear medicine planar images based on partial volume effects and recovery coefficients at different activity levels of radionuclides and matrix sizes
The partial volume effect evaluations had been effectively used as method for the evaluation of SPECT images in nuclear medicine. The study focused on the use of partial volume effect method and the evaluation of recovery coefficient in the 2D planar images in nuclear medicine. The planar images were obtained by using a modified Jaszczak phantom that contains radionuclide volume of differents diameter sizes and three activity levels. The planar images were also taken at three different matrix sizes of gamma camera set up at 128 x 128, 256 x 256 and 512 x 512. The results showed that the contrast values increased exponentially at larger diameter sizes of radionuclide. The contrast also significantly increased when higher matrix sizes were used. The recovery coefficient evaluation of the planar images were singnificantly decreased when larger matrix sizes were used. There were no significant differences between the recovery coefficients between planar images obtained with and without background counts. The overall results indicated the suitability of using the partical volume efffect method to evaluate the planar images of nuclear medicine.
- Open Access
- 25 November 2019
- Published by Penerbit Universiti Sains Malaysia in Journal of Physical Science
- Vol. 30 (3) , 131-155
Fabrication and Characterisations of Rhizophora spp. Particleboards Bonded with Corn Starch as Water Equivalent Phantoms for Diagnostic Photon Energy Ranges
Studies had been carried out to look for new phantom materials in medical physics that can provide better dose accuracy in comparison to water. This study focused on the fabrication and characterisations and of particleboards made of Rhizophora spp. as phantom for low and diagnostic photon energies. Rhizophora spp. particleboards were fabricated at different...
- 25 November 2019
- Published by Penerbit Universiti Sains Malaysia in Journal of Physical Science
- Vol. 30 (3) , 131-155
Open AccessFabrication and Characterisations of Rhizophora spp. Particleboards Bonded with Corn Starch as Water Equivalent Phantoms for Diagnostic Photon Energy Ranges
Studies had been carried out to look for new phantom materials in medical physics that can provide better dose accuracy in comparison to water. This study focused on the fabrication and characterisations and of particleboards made of Rhizophora spp. as phantom for low and diagnostic photon energies. Rhizophora spp. particleboards were fabricated at different...
- Open Access
- 1 January 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 298 (1) , 012023
Dosimetry of Al2O3optically stimulated luminescent dosimeter at high energy photons and electrons
The linearity of Al2O3 OSL dosimeters (OSLD) were evaluated for dosimetry works in clinical photons and electrons. The measurements were made at a reference depth of Zref according to IAEA TRS 398:2000 codes of practice at 6 and 10 MV photons and 6 and 9 MeV electrons. The measured dose was compared to the thermoluminescence dosimeters (TLD) and ionization chamber commonly used for dosimetry works for higher energy photons and electrons. The results showed that the measured dose in OSL dosimeters were in good agreement with the reported by the ionization chamber in both high energy photons and electrons. A reproducibility test also reported excellent consistency of readings with the OSL at similar energy levels. The overall results confirmed the suitability of OSL dosimeters for dosimetry works involving high energy photons and electrons in radiotherapy.
- 1 January 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 298 (1) , 012023
Open AccessDosimetry of Al2O3optically stimulated luminescent dosimeter at high energy photons and electrons
The linearity of Al2O3 OSL dosimeters (OSLD) were evaluated for dosimetry works in clinical photons and electrons. The measurements were made at a reference depth of Zref according to IAEA TRS 398:2000 codes of practice at 6 and 10 MV photons and 6 and 9 MeV electrons. The measured dose was compared to the thermoluminescence dosimeters (TLD) and ionization chamber commonly used for dosimetry works for higher energy photons and electrons. The results showed that the measured dose in OSL dosimeters were in good agreement with the reported by the ionization chamber in both high energy photons and electrons. A reproducibility test also reported excellent consistency of readings with the OSL at similar energy levels. The overall results confirmed the suitability of OSL dosimeters for dosimetry works involving high energy photons and electrons in radiotherapy.