Mohd Zahri Abdul Aziz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mohd Zahri Abdul Aziz has a total of 148 co-authors. Here are the top co-authors by number of shared publications:
- Noor Diyana Osman
Universiti Sains Malaysia
15 shared publications Ibrahim Lutfi Shuaib
11 shared publicationsHafiz M. Zin
10 shared publications- Rafidah Zainon
Department of Biomedical Imaging, Advanced Medical and Dental Institute, Universiti Sains Malaysia, SAINS@BERTAM, 13200 Kepala Batas, Pulau Pinang, Malaysia
8 shared publications - Reduan Abdullah
Hospital Universiti Sains Malaysia
6 shared publications - Suffian Mohamad Tajudin
Faculty of Health Sciences, Sultan Zainal Abidin University, Kuala Terengganu, Malaysia
6 shared publications
Latest Publications
- Open Access
- 9 February 2026
- Published by Elsevier in SSRN Electronic Journal
Morphological Irregularities and Attenuation Properties of PVAc-GOAgSn Polymer Nanocomposites
This study investigates the morphological irregularities of PVAc-based nanocomposites and their effect on photon radiation shielding. Nanocomposites were prepared using polyvinyl acetate (PVAc) with graphene oxide (GO), silver (Ag), and tin (Sn) fillers at selected ratios. GO was synthesized using a modified Hummer method, while Ag nanoparticles were produced via microwave irradiation. Sn powder was reduced in size using ball milling, and all fillers were dispersed in PVAc through probe sonication for uniform mixing. UV-Vis and FTIR analyses verified the successful synthesis of GO and Ag. FESEM observations revealed that Sn particles were not fully nanosized due to milling limitations and showed their distribution within the PVAc matrix. Photon attenuation tests were performed under medium- and high-energy photon and electron conditions to measure mass attenuation coefficient (MAC), linear attenuation coefficient (LAC), half-value layer (HVL), mean free path (MFP), and radiation protection efficiency (RPE). At 0.364 MeV, PVAc:GO:Ag:Sn achieved a MAC of 4.34 cm²/g, LAC of 10.06 cm⁻¹, HVL of 0.27 cm, TVL of 0.89 cm, MFP of 0.39 cm, and RPE of 56.87%. Under high-energy conditions, only the 6 MV photon beam showed positive shielding, suggesting selective performance. Further optimization of Sn particle size is recommended.
- 9 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMorphological Irregularities and Attenuation Properties of PVAc-GOAgSn Polymer Nanocomposites
This study investigates the morphological irregularities of PVAc-based nanocomposites and their effect on photon radiation shielding. Nanocomposites were prepared using polyvinyl acetate (PVAc) with graphene oxide (GO), silver (Ag), and tin (Sn) fillers at selected ratios. GO was synthesized using a modified Hummer method, while Ag nanoparticles were produced via microwave irradiation. Sn powder was reduced in size using ball milling, and all fillers were dispersed in PVAc through probe sonication for uniform mixing. UV-Vis and FTIR analyses verified the successful synthesis of GO and Ag. FESEM observations revealed that Sn particles were not fully nanosized due to milling limitations and showed their distribution within the PVAc matrix. Photon attenuation tests were performed under medium- and high-energy photon and electron conditions to measure mass attenuation coefficient (MAC), linear attenuation coefficient (LAC), half-value layer (HVL), mean free path (MFP), and radiation protection efficiency (RPE). At 0.364 MeV, PVAc:GO:Ag:Sn achieved a MAC of 4.34 cm²/g, LAC of 10.06 cm⁻¹, HVL of 0.27 cm, TVL of 0.89 cm, MFP of 0.39 cm, and RPE of 56.87%. Under high-energy conditions, only the 6 MV photon beam showed positive shielding, suggesting selective performance. Further optimization of Sn particle size is recommended.
- Open Access
- 22 January 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (5)
Enhancing quality control in radiography systems through automated algorithms
- 22 January 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (5)
Open AccessEnhancing quality control in radiography systems through automated algorithms
- 21 June 2025
- Published by Springer Nature in Health and Technology
- Vol. 15 (4) , 691-701
Efficacy of different high dose rate interstitial brachytherapy for tongue cancer: a systematic review
- 21 June 2025
- Published by Springer Nature in Health and Technology
- Vol. 15 (4) , 691-701
Efficacy of different high dose rate interstitial brachytherapy for tongue cancer: a systematic review
- 15 May 2025
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 29 (3) , 104626
Sole high dose-rate interstitial brachytherapy for early-stage tongue cancer: A systematic review
- 15 May 2025
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 29 (3) , 104626
Sole high dose-rate interstitial brachytherapy for early-stage tongue cancer: A systematic review
- Open Access
- 1 January 2025
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 17 (1) , 28-32
Diaphragm and lung dose in liver high-dose-rate interstitial brachytherapy: A dosimetry and toxicity report
Purpose: The aim of this study was to retrospectively analyze and report on dose-volume and clinical toxicity of liver high-dose-rate interstitial brachytherapy (HDR-IBT) used in diaphragm and lung tissue. Material and methods: Computed tomography (CT)-based liver HDR-IBT using Oncentra...
- 1 January 2025
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 17 (1) , 28-32
Open AccessDiaphragm and lung dose in liver high-dose-rate interstitial brachytherapy: A dosimetry and toxicity report
Purpose: The aim of this study was to retrospectively analyze and report on dose-volume and clinical toxicity of liver high-dose-rate interstitial brachytherapy (HDR-IBT) used in diaphragm and lung tissue. Material and methods: Computed tomography (CT)-based liver HDR-IBT using Oncentra...
- Open Access
- 6 October 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (1) , 301-308
Radiation attenuation and elemental composition of locally available ceramic tiles as potential radiation shielding materials for diagnostic X-ray rooms
- 6 October 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (1) , 301-308
Open AccessRadiation attenuation and elemental composition of locally available ceramic tiles as potential radiation shielding materials for diagnostic X-ray rooms
- Open Access
Dosimetric Characterization of DSF/NaOH/IA-PAE/R. spp. Phantom Material for Radiation Therapy
Background: Different compositions of DSF/NaOH/IA-PAE/R. spp. composite particleboard phantoms were constructed. Methods: Photon attenuation characteristics were ascertained using gamma rays from 137Cs and 60Co. Absorbed doses at the location of an ionization chamber and Gafchromic EBT3 radiochromic films were calculated for high-energy photons (6 and 10 MV) and electrons (6, 9, 12, and 15 MeV). Results: The calculated TPR20,10 values indicate that the percentage discrepancy for 6 and 10 MV was in the range of 0.29–0.72% and 0.26–0.65%. It was also found that the relative difference in the to water and solid water phantoms was between 1.08–1.28% and 5.42–6.70%. The discrepancies in the determination of PDD curves with 6, 9, 12, and 15 MeV, and those of water and solid water phantoms, ranged from 2.40–4.84%. Comparable results were found using the EBT3 films with variations of 2.0–7.0% for 6 and 10 MV photons. Likewise, the discrepancies for 6, 9, 12, and 15 MeV electrons were within an acceptable range of 2.0–4.5%. Conclusions: On the basis of these findings, the DSF/NaOH/IA-PAE/R. spp. particleboard phantoms with 15 wt% IA-PAE addition level can be effectively used as alternative tissue-equivalent phantom material for radiation therapy applications.Open AccessDosimetric Characterization of DSF/NaOH/IA-PAE/R. spp. Phantom Material for Radiation Therapy
Background: Different compositions of DSF/NaOH/IA-PAE/R. spp. composite particleboard phantoms were constructed. Methods: Photon attenuation characteristics were ascertained using gamma rays from 137Cs and 60Co. Absorbed doses at the location of an ionization chamber and Gafchromic EBT3 radiochromic films were calculated for high-energy photons (6 and 10 MV) and electrons (6, 9, 12, and 15 MeV). Results: The calculated TPR20,10 values indicate that the percentage discrepancy for 6 and 10 MV was in the range of 0.29–0.72% and 0.26–0.65%. It was also found that the relative difference in the to water and solid water phantoms was between 1.08–1.28% and 5.42–6.70%. The discrepancies in the determination of PDD curves with 6, 9, 12, and 15 MeV, and those of water and solid water phantoms, ranged from 2.40–4.84%. Comparable results were found using the EBT3 films with variations of 2.0–7.0% for 6 and 10 MV photons. Likewise, the discrepancies for 6, 9, 12, and 15 MeV electrons were within an acceptable range of 2.0–4.5%. Conclusions: On the basis of these findings, the DSF/NaOH/IA-PAE/R. spp. particleboard phantoms with 15 wt% IA-PAE addition level can be effectively used as alternative tissue-equivalent phantom material for radiation therapy applications. - Open Access
- 27 September 2022
- Published by Taylor & Francis in Hepatic Oncology
- Vol. 9 (3) , HEP44
Pathological complete Response with Immunotherapy and Brachytherapy to 15 Metastatic Liver Lesions in a Single Patient
Materials & methods: High dose rate interstitial brachytherapy (HDR-IBT) treatment plan for 15 metastatic liver lesions in a patient with pancreatic cancer was retrieved and analyzed for liver dose...
- 27 September 2022
- Published by Taylor & Francis in Hepatic Oncology
- Vol. 9 (3) , HEP44
Open AccessPathological complete Response with Immunotherapy and Brachytherapy to 15 Metastatic Liver Lesions in a Single Patient