William Lack
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
William Lack has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Hobie D. Summers
Loyola University Medical Center, Maywood, United States
2 shared publications - Cameron J. Killen
Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, 2160 S. First Avenue,Maguire Suite 1700, Maywood, IL 60153, USA
1 shared publication - Joseph B. Cohen
Loyola University Medical Center, Maywood, United States
1 shared publication - Kyle B.S. Lynch
Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, 2160 S. First Avenue, Maguire Suite 1700, Maywood, IL 60153, Fax: 708-216-9348, Phone: 708-216-4992,
1 shared publication - Michael D. Stover
Feinberg School of Medicine, Northwestern University
1 shared publication - Michael P. Murphy
Department of Orthopaedic Surgery and Rehabilitation, Loyola University Medical Center, Maywood, IL, USA
1 shared publication
Latest Publications
- 21 February 2020
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 34 (8) , e272-e281
Minimally Invasive Medial Plate Osteosynthesis of High-Energy Pediatric Tibia Fractures
Objectives: We report on the largest series to date of minimally invasive medial plate osteosynthesis of high-energy tibia fractures in skeletally immature patients. Design: Retrospective. Setting: Level 1 trauma center. Patients: Skeletally immature patients with high-energy tibia fractures treated with minimally invasive medial plate osteosynthesis between 2006 and 2017. We identified 28 fractures in 26 patients. Main Outcome Measure: We reviewed the record for patient, injury, and treatment factors as well as for complications and reoperation. We assessed the relationships between age, implant selection, and implant removal using χ2 and t test analyses. Results: Mean age was 12 years (4–15) with OTA/AO classifications including 42A (18), 42B (6), and 42C (4). There were 10 open fractures (1 type I, 2 type II, and 7 type III). Mean follow-up was 37.6 months (minimum 7). Mean time to full weight-bearing and union was 2 and 3 months, respectively. Plate stock (2.7, 3.5, and 4.5 mm) and length (6–20 holes) varied independent of age, P = 0.19. There were 2 superficial infections, one 15 mm leg length discrepancy, and one case of fasciotomy at the time of plate fixation for trauma-related compartment syndrome. Implant removal was more likely in younger patients (10.9 vs. 13.2 years, P = 0.04) and not associated with plate stock, P = 0.97. There were no neurovascular injuries, losses of reduction, or rotational deformities. Angulation was universally <5 degrees in the coronal plane and <10 degrees in the sagittal plane. Conclusions: Minimally invasive medial plate osteosynthesis of high-energy pediatric tibia fractures may be performed with a low rate of complications and should be considered in this select patient population with multiple injuries, high-energy mechanisms, and significant soft-tissue trauma. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 21 February 2020
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 34 (8) , e272-e281
Minimally Invasive Medial Plate Osteosynthesis of High-Energy Pediatric Tibia Fractures
Objectives: We report on the largest series to date of minimally invasive medial plate osteosynthesis of high-energy tibia fractures in skeletally immature patients. Design: Retrospective. Setting: Level 1 trauma center. Patients: Skeletally immature patients with high-energy tibia fractures treated with minimally invasive medial plate osteosynthesis between 2006 and 2017. We identified 28 fractures in 26 patients. Main Outcome Measure: We reviewed the record for patient, injury, and treatment factors as well as for complications and reoperation. We assessed the relationships between age, implant selection, and implant removal using χ2 and t test analyses. Results: Mean age was 12 years (4–15) with OTA/AO classifications including 42A (18), 42B (6), and 42C (4). There were 10 open fractures (1 type I, 2 type II, and 7 type III). Mean follow-up was 37.6 months (minimum 7). Mean time to full weight-bearing and union was 2 and 3 months, respectively. Plate stock (2.7, 3.5, and 4.5 mm) and length (6–20 holes) varied independent of age, P = 0.19. There were 2 superficial infections, one 15 mm leg length discrepancy, and one case of fasciotomy at the time of plate fixation for trauma-related compartment syndrome. Implant removal was more likely in younger patients (10.9 vs. 13.2 years, P = 0.04) and not associated with plate stock, P = 0.97. There were no neurovascular injuries, losses of reduction, or rotational deformities. Angulation was universally <5 degrees in the coronal plane and <10 degrees in the sagittal plane. Conclusions: Minimally invasive medial plate osteosynthesis of high-energy pediatric tibia fractures may be performed with a low rate of complications and should be considered in this select patient population with multiple injuries, high-energy mechanisms, and significant soft-tissue trauma. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 5 February 2016
- Published by Springer Nature in Current Geriatrics Reports
- Vol. 5 (1) , 38-43
Evaluation of Common Fractures of the Hip in the Elderly
- 5 February 2016
- Published by Springer Nature in Current Geriatrics Reports
- Vol. 5 (1) , 38-43
Evaluation of Common Fractures of the Hip in the Elderly