HSHobie D. Summers

Hobie D. Summers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hobie D. Summers has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimal timing for hemodialysis in relation to hip fracture surgery for patients with end-stage renal disease

    by Hanna E. House, Michelle R. Shimizu, Insup Hong Ma, Joseph B. Cohen, Hobie D. Summers, Ashley E. Levack

    Introduction End-stage renal disease (ESRD) is associated with a significantly increased risk of hip fractures and a higher rate of postoperative complications and mortality, particularly in patients on hemodialysis (HD). The timing of HD relative to surgery may influence outcomes by altering acid–base balance, electrolyte levels, and fluid status. This study aimed to evaluate the effect of perioperative HD timing on postoperative complication rates in ESRD patients undergoing hip fracture surgery. Materials and Methods This retrospective cohort study included patients with ESRD on HD who underwent operative treatment for hip fractures at a single Level I academic trauma center. Patient demographics, comorbidities, and perioperative variables were collected. Timing of HD was calculated as the interval in hours from the start of HD to the start of surgery. Disruptions in patients’ routine HD schedules were also recorded. Univariable logistic regression was used to assess associations between HD timing and 90-day postoperative complications. Results Forty-one patients met inclusion criteria; 25 (61.0%) experienced a postoperative complication. The interval between HD and surgery did not significantly predict postoperative outcomes. Disruption of routine HD schedules, observed in 31 patients, was also not associated with increased risk of complications (OR = 0.94, 95% CI = [0.22, 4.00], p = 0.929). Conclusions Neither the timing of preoperative HD nor disruptions in HD scheduling were significantly associated with 90-day postoperative complications in ESRD patients undergoing hip fracture surgery. As the first study to examine this relationship in this population, these findings contribute to the growing body of evidence guiding perioperative management in dialysis-dependent patients. Further research with larger sample sizes is needed to confirm these results.

  • Geriatric femur fractures: Index fracture pattern is associated with the risk of subsequent peri-implant fracture

    by Michael P. Murphy, Madeline S. Tiee, Bailey E. Johnson, Hobie D. Summers, Joseph B. Cohen, William D. Lack


  • Open Access

    Sagittal deformity of Garden type I and II geriatric femoral neck fractures is frequently misclassified by lateral radiographs

    by Madeline S. Tiee, Andrew G. Golz, Andrew Ba Kim, Joseph B. Cohen, Hobie D. Summers, Anup J. Alexander, William D. Lack

    Objectives: The objective of this study was to determine the validity and inter-rater reliability of radiographic assessment of sagittal deformity of femoral neck fractures. Design: This is a retrospective cohort study. Setting: Level 1 trauma center. Patients/Participants: Thirty-one patients 65 years or older who sustained low-energy, Garden type I/II femoral neck fractures imaged with biplanar radiographs and either computed tomography or magnetic resonance imaging were included. Main Outcome Measurements: Preoperative sagittal tilt was measured on lateral radiographs and compared with the tilt identified on advanced imaging. Fractures were defined as “high-risk” if posterior tilt was ≥20 degrees or anterior tilt was >10 degrees. Results: Of 31 Garden type I/II femoral neck fractures, advanced imaging identified 10 high-risk fractures including 8 (25.8%) with posterior tilt ≥20 degrees and 2 (6.5%) with anterior tilt >10 degrees. Overall, there was no significant difference between sagittal tilt measured using lateral radiographs and advanced imaging (P = 0.84), and the 3 raters had good agreement between their measurements of sagittal tilt on lateral radiographs (interclass correlation coefficient 0.79, 95% confidence interval [0.65, 0.88], P < 0.01). However, for high-risk fractures, radiographic measurements from lateral radiographs alone resulted in greater variability and underestimation of tilt by 5.2 degrees (95% confidence interval [−18.68, 8.28]) when compared with computed tomography/magnetic resonance imaging. Owing to this underestimation of sagittal tilt, the raters misclassified high-risk fractures as “low-risk” in most cases (averaging 6.3 of 10, 63%, range 6 − 7) when using lateral radiographs while low-risk fractures were rarely misclassified as high-risk (averaging 1.7 of 21, 7.9%, range 1 − 3, P = 0.01). Conclusions: Lateral radiographs frequently lead surgeons to misclassify high-risk sagittal tilt of low-energy femoral neck fractures as low-risk. Further research is necessary to improve the assessment of sagittal plane deformity for these injuries. Level of Evidence: Level IV diagnostic study.


  • Minimally Invasive Medial Plate Osteosynthesis of High-Energy Pediatric Tibia Fractures

    by Michael Murphy, Cameron Killen, Kyle B.S. Lynch, Joseph Cohen, Hobie Summers, Michael Stover, William Lack

    Objectives: We report on the largest series to date of minimally invasive medial plate osteosynthesis of high-energy tibia fractures in skeletally immature patients. Design: Retrospective. Setting: Level 1 trauma center. Patients: Skeletally immature patients with high-energy tibia fractures treated with minimally invasive medial plate osteosynthesis between 2006 and 2017. We identified 28 fractures in 26 patients. Main Outcome Measure: We reviewed the record for patient, injury, and treatment factors as well as for complications and reoperation. We assessed the relationships between age, implant selection, and implant removal using χ2 and t test analyses. Results: Mean age was 12 years (4–15) with OTA/AO classifications including 42A (18), 42B (6), and 42C (4). There were 10 open fractures (1 type I, 2 type II, and 7 type III). Mean follow-up was 37.6 months (minimum 7). Mean time to full weight-bearing and union was 2 and 3 months, respectively. Plate stock (2.7, 3.5, and 4.5 mm) and length (6–20 holes) varied independent of age, P = 0.19. There were 2 superficial infections, one 15 mm leg length discrepancy, and one case of fasciotomy at the time of plate fixation for trauma-related compartment syndrome. Implant removal was more likely in younger patients (10.9 vs. 13.2 years, P = 0.04) and not associated with plate stock, P = 0.97. There were no neurovascular injuries, losses of reduction, or rotational deformities. Angulation was universally <5 degrees in the coronal plane and <10 degrees in the sagittal plane. Conclusions: Minimally invasive medial plate osteosynthesis of high-energy pediatric tibia fractures may be performed with a low rate of complications and should be considered in this select patient population with multiple injuries, high-energy mechanisms, and significant soft-tissue trauma. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


  • The influence of biplanar reduction and surgeon experience on proximal humerus fractures treated with ORIF

    by Tomas Liskutin, Elizabeth Harkin, Hobie Summers, Joseph Cohen, Mitchell Bernstein, William Lack


  • Compliance With Weight-Bearing Precautions: A Prospective Observational Study

    by Michael Murphy, Bailey Johnson, William Davis, William ['Dimitri'], Hobie Summers, Joseph Cohen, William Lack

    Introduction: Patients are instructed on weight-bearing restrictions after orthopaedic trauma based on historical norms, clinical intuition, and |

  • Evaluation of Common Fractures of the Hip in the Elderly

    by Patrick Strotman, William Lack, Mitchell Bernstein, Michael Stover, Hobie Summers