VNVinod Narayanan

Vinod Narayanan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vinod Narayanan has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental characterization of an additively manufactured supercritical carbon dioxide recuperator

    by Sreedev Das, Erfan Rasouli, Tiago A. Moreira, Nicholas Lamprinakos, Junwon Seo, Anthony Rollett, Mark Anderson, Vinod Narayanan


  • Open Access

    Assessment of the relative impacts of feature accuracy and surface roughness on fluid flow across additively manufactured pin arrays

    by Ines-Noelly Tano, Erfan Rasouli, Junwon Seo, Subbarao Raikar, Owen Hildreth, Anthony Rollett, Vinod Narayanan


  • Open Access

    Additively Manufactured Molten Salt to Supercritical Carbon Dioxide Heat Exchanger

    by Vinod Narayanan, Erfan Rasouli, Anthony D Rollett, Parth Vaishnav, Owen Hildreth, Ines-Noelly Tano, Nicholas Lamprinakos, Junwon Seo, Youyang Zhao, Tracey L Ziev, et al.

    Design, fabrication, and experimental characterization of the performance of a molten salt (MS)-to-supercritical carbon dioxide (sCO2) heat exchanger (HE) for concentrating solar power (CSP) applications using laser powder bed fusion (LPBF) additive manufacturing (AM) of nickel-based superalloys is presented in this report. The hypothesis is that such additively manufactured HEs will result in a monolithic, compact, low-pressure drop HE that is durable under cyclic operation at high temperature and high pressure in a corrosive salt environment. Two nickel-based superalloys were considered in the project- Haynes 230 (H230) and Haynes 282 (H282). Process windows for LPBF AM were established to provide dense low porosity parts for both alloys. Creep tests results on heat treated AM H230 and H282 samples showed that the AM fabricated specimens were as robust as the wrought specimens and showed no deficit in creep strength at high temperatures. Haynes 282 was down selected for the HE fabrication based on better dimensional tolerance, better corrosion resistance to chloride salt, and higher creep strength. The HE was designed for an inlet temperature of 720 °C on the chloride salt side and 500 °C on the sCO2 side. The design system pressure on the sCO2 side was 200 bar, with a pressure drop less than 2% of line pressure on the sCO2 side. To reduce parasitic losses in the MS loop, it was desired to have a low exit temperature on the MS exit. Two designs (generation 1 and 2) of the HE were developed by a co-design effort considering mechanical stresses, thermal and fluidic performance, and AM fabrication constraints such as overhangs, powder removal and build dimensions. The HE core designs consist of a pin array on the sCO2 side and either straight or 3D periodic lattice on the MS side. Additional design considerations included creep, fatigue and thermal stresses. A key concern for use of chloride salts in CSP pertains to the high corrosion rate. To assess whether AM printed specimens would have different corrosion rates than wrought samples, corrosion tests on printed H230 and H282 specimens were performed in purified chloride salt with baseline wrought samples as reference. AM H282 was superior to AM H230 with a best corrosion rate of around 110 µm/year compared with heat treated H230 corrosion rate of 268.3 ± 28.8 µm/year. One of the key issues with LPBF is the roughness and feature accuracy of the geometry, both of which can cause excessive pressure drop. Two methods of smoothening the internal flow passages of the HE were explored- a physical method of abrasive liquid slurry flow, and a novel iodine-based chemical treatment. The pressure drop through the pin array is reduced by 15-30% with the liquid abrasive slurry treatment, with varying reductions depending on the extent of the treatment, geometry of the pin array, and mass flow rate. The iodine-based is a Self-Terminating Etching Process (STEP) to uniformly remove material from all fluid-accessible surfaces while preserving the intricate geometrical features. Pressure drop reductions of up to 21% were measured between the baseline and chemically treated pin array. A simplified thermo-fluidic sectional model, based on correlations for pin arrays in open literature, was developed for design and analysis of the HE performance. With account for the larger flow frontal area caused due to the down-skin on the pins, it is possible to get reasonable predictions for heat transfer using the Rasouli et al. (2018) correlation for the designs experimentally characterized in this study. The Prasher et al. (2007) correlation provided the best fit to experimental pressure drop data. A process-based cost model (PBCM) that included powder, LPBF print time, and post processing steps was developed to estimate the cost of the HE. The PBCM was used to assess the impact of design changes, process parameters, and innovations in LPBF technology on the cost of the HE. To experimentally demonstrate the performance of the HE, a 20 pair unit was fabricated and characterized. Heated air was used as a surrogate to the chloride salt on the hot side and sCO2 in the 100-200 bar range was used on the cold side. The results of exit temperatures and heat transfer rate were compared against the model. The model was able to predict experimental results to within 0.8% percent for heat transfer rate, 0.97% percent for exit sCO2 temperature, and 1.5% percent for exit air temperature. Preliminary work on potential to scale up the HE was undertaken through demonstration of taller builds in the LPBF machine. The validated HE model was used to determine the performance of a scaled-up design. With a 20 cm tall build that covers 24 cm x 24 cm of the build plate, a 166 kW HE can be built in a single laser machine with a bed size of 25 cm x 25 cm. The impact of system-level variations in inlet temperature on the performance of this HE was established. In summary, it was demonstrated in this project that it is feasible to design and fabricate, using metal AM, compact primary HEs that meet the performance targets at the stringent operating conditions encountered in the liquid pathway for Gen3 CSP power plants, and established cost metrics.

  • Micro-laminated pin array solar receivers for high flux heating of supercritical carbon dioxide part 2: On-sun performance

    by Erfan Rasouli, Caton W. Mande, Brian M. Fronk, Vinod Narayanan, Ömer N. Doğan, Kyle A. Rozman, Matthew A. Carl


  • Micro-laminated pin array solar receivers for high flux heating of supercritical carbon dioxide part 1: Design and fabrication methods

    by Brian M. Fronk, Bryan J. Siefering, Brian K. Paul, W. Hank Pratte, Ömer N. Doğan, Kyle A. Rozman, Erfan Rasouli, Vinod Narayanan


  • A Scalable Compact Additively Manufactured Molten Salt to Supercritical Carbon Dioxide Heat Exchanger for Solar Thermal Application

    by Ines-Noelly Tano, Erfan Rasouli, Tracey Ziev, Junwon Seo, Nicholas Lamprinakos, Parth Vaishnav, Anthony Rollett, Ziheng Wu, Vinod Narayanan

    Design of an additively manufactured molten salt (MS) to supercritical carbon dioxide (sCO2) primary heat exchanger (PHE) for solar thermal power generation is presented. The PHE is designed to handle temperatures up to 720 °C on the MS side and an internal pressure of 200 bar on the sCO2 side. In the core, MS flows through a three-dimensional periodic lattice network, while sCO2 flows within pin arrays. The design includes integrated sCO2 headers located within the MS flow, allowing for a counter flow design of the PHE. The sCO2 headers are configured to enable uniform flow distribution into each sCO2 plate while withstanding an internal pressure of 200 bar and minimizing obstruction to the flow of MS around it. The structural integrity of the design is verified on AM 316 stainless steel printed sub-scale specimens. An experimentally-validated, correlation-based sectional PHE core thermofluidic model is developed to study the impact of flow and geometrical parameters on the PHE performance, with varied parameters including the mass flow rate, surface roughness, and PHE dimensions. A process-based cost model is used to determine the impact of parameter variation on build cost. The model results show that a heat exchanger with a power density of 18.6 MW/m3 (including sCO2 header volume) and effectiveness of 0.88 can be achieved at a heat capacity rate ratio of 0.8. The impact of design and AM machine parameters on the cost of the PHE are assessed.


  • Open Access

    An additively-manufactured molten salt-to-supercritical carbon di-oxide primary heat exchanger for solar thermal power generation – Design and techno-economic performance

    by Ines-Noelly Tano, Erfan Rasouli, Tracey Ziev, Ziheng Wu, Nicholas Lamprinakos, Junwon Seo, Lukas Schulze Balhorn, Parth Vaishnav, Anthony Rollett, Vinod Narayanan


  • Open Access

    High efficiency 3-D printed microchannel polymer heat exchangers for air conditioning applications

    by Erfan Rasouli, Emily Fricke, Vinod Narayanan

    The design, fabrication, and experimental characterization of a counterflow Micro-pin array Polymer Heat eXchanger (MPHX) for HVAC applications is described. The design consists of water flow through microscale pin array plates, and airflow paths in a counterflow direction through adjacent rectangular channels. When compared to a Finned Tube Heat eXchanger (FTHX), the water plates take the place of fins and the crossflow tube bank is eliminated. The MPHX is fabricated by 3 D printing using a digital light synthesis method. A correlation-based model is developed and used to explore the parametric space to arrive at a baseline MPHX core geometry. Mechanical and fluidic simulations are performed on the baseline geometry to further develop the design. A sub-scale MPHX with a nominal cross duct area of 10.1 cm × 20.3 cm is designed and fabricated. Its thermal performance over a range of air and water flow rates corresponding to heat capacity rate ratios in the range of 0.25–1 is investigated. Results show that the effectiveness varies from 0.65 to 0.95 corresponding to a Cṙ  of 1 to 0.25. The experimental data are used to validate a correlation-based thermo-fluidic model of the MPHX. The validated model is further used to compare the performance advantages of the MPHX design over a FTHX. For a given heat exchanger volume and thermo-fluidic conditions, the MPHX transfers 55% more thermal energy when compared to a FTHX at comparable air-side pressure drops.


  • Open Access

    A mechanistic thermal balance model of dairy cattle

    by Jinghui Li, Vinod Narayanan, Ermias Kebreab, Serdal Dikmen, James G. Fadel


  • Asymmetric Sawtooth Microstructure-Induced Vapor Mobility for Suppressed Buoyancy Conditions: Terrestrial Experiment and Design for ISS Experiments

    by Karthekeyan Sridhar, Vinod Narayanan, Sushil H. Bhavnani

    The lack of buoyancy forces in microgravity stagnates vapor bubbles on heated electronic surfaces, raising local surface temperatures above device operating limits. Though flow boiling can help dissipate higher heat fluxes, the addition of pumps and regulated flow loops increases design complexity for electronic systems. Passive directional motion of the fluid using an asymmetric sawtooth microstructure has demonstrated motion along the surface due to viscous forces. The current study explores the sawtooth microstructure in the nucleate boiling regime for a horizontal upward- and downward-facing orientation with varying sawtooth profiles (60°–30° and 75°–15°) in terrestrial gravity conditions as a precursor to the International Space Station (ISS) experiments. A laser powder bed fusion metal additive manufacturing technique was used to fabricate the test surfaces with 250- $\mu \text{m}$ nucleation sites located on the long slopes. For the test surface with cavities spaced 2-mm apart, the wall superheat was ~4 K lower compared to cavities spaced 1 mm apart in the upward-facing orientation. The downward-facing surface induced passive vapor mobility in the direction of the long slope, and a thin liquid film was observed between the vapor mass and microstructure. This liquid film thickness was predicted using a simplified force balance model modified from a prior parabolic flight experiment. The model predicted a uniform liquid film thickness of $49~\mu \text{m}$ for a vapor slug moving at 13.7 mm/s with the input heat flux at 1.25 W/cm 2 . These terrestrial tests in the adverse orientation suggest that the sawtooth microstructure will successfully induce vapor mobility in upcoming ISS microgravity experiments. Elements of the final flight ampoule, including the cooling zone, the two-stage pressure relief system, and the high-speed imagery setup, are discussed.