John G. Person
Research Subjects
Research Interests
John G. Person has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Barry Wylant
School of Architecture, Planning, and Landscape, University of Calgary, Calgary, AB T2N 1N4, Canada
2 shared publications - Carolyn Anglin
Biomedical Engineering, University of Calgary, Calgary, AB, Canada McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada Department of Civil Engineering, University of Calgary, Calgary, AB, Canada
2 shared publications - Cinzia Gaudelli
Section of Orthopaedic Surgery, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada
2 shared publications - Emmanuel M. Illical
Department of Orthopedic Surgery, Einstein Healthcare Network, 5501 Old York Road, WCB4, Philadelphia, PA, 19141, USA.
2 shared publications - Erica L. Rex
Biomedical Engineering and McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB T2N 1N4, Canada
2 shared publications - Karen C. T. Arlt
Biomedical Engineering and McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB T2N 1N4, Canada
1 shared publication
Latest Publications
- Open Access
- 10 May 2018
- Published by MDPI AG in Bioengineering
- Vol. 5 (2) , 38
Guiding Device for the Patellar Cut in Total Knee Arthroplasty: Design and Validation
An incorrect cut of the patella (kneecap) during total knee arthroplasty, affects the thickness in different quadrants of the patella, leading to pain and poor function. Because of the disadvantages of existing devices, many surgeons choose to perform the cut freehand. Given this mistrust of existing devices, a quick, but accurate, method is needed that guides the cut, without constraining the surgeon. A novel device is described that allows the surgeon to mark a line at the desired cutting plane parallel to the front (anterior) surface using a cautery tool, remove the device, and then align the saw guide, reamer, or freehand saw with the marked line to cut the patella. The device was tested on 36 artificial patellae, custom-molded from two shapes considered easier and harder to resect accurately, and eight paired cadaveric specimens, each in comparison to the conventional saw guide technique. The mediolateral angle, superoinferior angle, difference from intended thickness, and time were comparable or better for the new device. Addressing the remaining outliers should be possible through additional design changes. Use of this guidance device has the potential to improve patellar resection accuracy, as well as provide training to residents and a double-check and feedback tool for expert surgeons.
- 10 May 2018
- Published by MDPI AG in Bioengineering
- Vol. 5 (2) , 38
Open AccessGuiding Device for the Patellar Cut in Total Knee Arthroplasty: Design and Validation
An incorrect cut of the patella (kneecap) during total knee arthroplasty, affects the thickness in different quadrants of the patella, leading to pain and poor function. Because of the disadvantages of existing devices, many surgeons choose to perform the cut freehand. Given this mistrust of existing devices, a quick, but accurate, method is needed that guides the cut, without constraining the surgeon. A novel device is described that allows the surgeon to mark a line at the desired cutting plane parallel to the front (anterior) surface using a cautery tool, remove the device, and then align the saw guide, reamer, or freehand saw with the marked line to cut the patella. The device was tested on 36 artificial patellae, custom-molded from two shapes considered easier and harder to resect accurately, and eight paired cadaveric specimens, each in comparison to the conventional saw guide technique. The mediolateral angle, superoinferior angle, difference from intended thickness, and time were comparable or better for the new device. Addressing the remaining outliers should be possible through additional design changes. Use of this guidance device has the potential to improve patellar resection accuracy, as well as provide training to residents and a double-check and feedback tool for expert surgeons.
- 12 May 2016
- Published by ASME International in Journal of Medical Devices
- Vol. 10 (2) , 024502
Device for Verifying the Patellar Cut During Knee Replacement Surgery
Cutting the kneecap (patella) in knee replacement surgery is challenging and can lead to pain and reduced function when done incorrectly. The presented device allows the surgeon to check the three-dimensional symmetry and thickness of the bone remnant before the operation is complete. Observations and measurements made on 36 resected artificial patellae and 16 resected cadaveric patellae matched well with computed tomography (CT) scans of the patellae with few exceptions; the exceptions should be addressable by changes in design and use. Average time to apply the device was 1 min.
- 12 May 2016
- Published by ASME International in Journal of Medical Devices
- Vol. 10 (2) , 024502
Device for Verifying the Patellar Cut During Knee Replacement Surgery
Cutting the kneecap (patella) in knee replacement surgery is challenging and can lead to pain and reduced function when done incorrectly. The presented device allows the surgeon to check the three-dimensional symmetry and thickness of the bone remnant before the operation is complete. Observations and measurements made on 36 resected artificial patellae and 16 resected cadaveric patellae matched well with computed tomography (CT) scans of the patellae with few exceptions; the exceptions should be addressable by changes in design and use. Average time to apply the device was 1 min.