Karen C. T. Arlt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Karen C. T. Arlt has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Barry Wylant
School of Architecture, Planning, and Landscape, University of Calgary, Calgary, AB T2N 1N4, Canada
1 shared publication - Carolyn Anglin
Biomedical Engineering, University of Calgary, Calgary, AB, Canada McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada Department of Civil Engineering, University of Calgary, Calgary, AB, Canada
1 shared publication - Cinzia Gaudelli
Section of Orthopaedic Surgery, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada
1 shared publication - Emmanuel M. Illical
Department of Orthopedic Surgery, Einstein Healthcare Network, 5501 Old York Road, WCB4, Philadelphia, PA, 19141, USA.
1 shared publication - Erica L. Rex
Biomedical Engineering and McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB T2N 1N4, Canada
1 shared publication - John G. Person
Box 13 Engineering, Calgary, AB T3L 2P5, Canada
1 shared publication
Latest Publications
- Open Access
- 10 May 2018
- Published by MDPI AG in Bioengineering
- Vol. 5 (2) , 38
Guiding Device for the Patellar Cut in Total Knee Arthroplasty: Design and Validation
An incorrect cut of the patella (kneecap) during total knee arthroplasty, affects the thickness in different quadrants of the patella, leading to pain and poor function. Because of the disadvantages of existing devices, many surgeons choose to perform the cut freehand. Given this mistrust of existing devices, a quick, but accurate, method is needed that guides the cut, without constraining the surgeon. A novel device is described that allows the surgeon to mark a line at the desired cutting plane parallel to the front (anterior) surface using a cautery tool, remove the device, and then align the saw guide, reamer, or freehand saw with the marked line to cut the patella. The device was tested on 36 artificial patellae, custom-molded from two shapes considered easier and harder to resect accurately, and eight paired cadaveric specimens, each in comparison to the conventional saw guide technique. The mediolateral angle, superoinferior angle, difference from intended thickness, and time were comparable or better for the new device. Addressing the remaining outliers should be possible through additional design changes. Use of this guidance device has the potential to improve patellar resection accuracy, as well as provide training to residents and a double-check and feedback tool for expert surgeons.
- 10 May 2018
- Published by MDPI AG in Bioengineering
- Vol. 5 (2) , 38
Open AccessGuiding Device for the Patellar Cut in Total Knee Arthroplasty: Design and Validation
An incorrect cut of the patella (kneecap) during total knee arthroplasty, affects the thickness in different quadrants of the patella, leading to pain and poor function. Because of the disadvantages of existing devices, many surgeons choose to perform the cut freehand. Given this mistrust of existing devices, a quick, but accurate, method is needed that guides the cut, without constraining the surgeon. A novel device is described that allows the surgeon to mark a line at the desired cutting plane parallel to the front (anterior) surface using a cautery tool, remove the device, and then align the saw guide, reamer, or freehand saw with the marked line to cut the patella. The device was tested on 36 artificial patellae, custom-molded from two shapes considered easier and harder to resect accurately, and eight paired cadaveric specimens, each in comparison to the conventional saw guide technique. The mediolateral angle, superoinferior angle, difference from intended thickness, and time were comparable or better for the new device. Addressing the remaining outliers should be possible through additional design changes. Use of this guidance device has the potential to improve patellar resection accuracy, as well as provide training to residents and a double-check and feedback tool for expert surgeons.