YOYoshito Otake

Yoshito Otake

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yoshito Otake has a total of 163 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • CT-based assessment of skeletal deterioration after high-dose denosumab discontinuation in metastatic breast cancer

    by Suguru Yokoo, Keisuke Uemura, Shinichiro Kubo, Masahiko Ikeda, Tetsumasa Yamashita, Kumiko Yoshikawa, Yoshito Otake, Chuji Terada

  • Open Access

    Validity of Bone Mineral Density Measurements Using SONIALVISION G4: A Quantitative CT-based Evaluation

    by Junichiro Morita, Keisuke Uemura, Sotaro Kono, Yi Gu, Yuto Nishioka, Tomoki Asano, Ryo Higuchi, Hirokazu Mae, Makoto Iwasa, Tetsuro Tani, et al.

    Introduction: SONIALVISION G4 is a fluoroscopic imaging system equipped with a bone densitometry function calibrated against GE Healthcare dual-energy X-ray absorptiometry (DXA) measurements. However, evidence supporting the validity of in vivo bone mineral density (BMD) measurements remains limited. This study compared BMD measurements obtained using SONIALVISION G4 with GE DXA reference data and evaluated their validity using quantitative computed tomography (CT). Materials and Methods: A total of 887 BMD examinations performed with SONIALVISION G4 in women aged ≥45 years were compared with published Japanese reference data obtained using GE DXA. CT-derived BMD was quantified using a validated deep learning–based method and compared with measurements obtained using SONIALVISION G4 in 30 patients. To validate the CT method against GE DXA, 697 patients from four additional institutions underwent GE DXA and CT. Analyses were conducted for both the femoral neck and total hip. Results: Femoral neck BMD generally showed small differences from the reference values, whereas total hip BMD was consistently higher in women aged ≥55 years. CT-derived BMD correlated with SONIALVISION G4 measurements (r = 0.762 and 0.842 for the femoral neck and total hip, respectively), with median absolute differences of 0.022 and 0.133 g/cm 2 . In contrast, CT-derived BMD showed very strong correlations with GE DXA (r = 0.913 and 0.959) and smaller absolute differences (0.043 and 0.033 g/cm 2 ). Conclusion: SONIALVISION G4 showed small differences in femoral neck BMD measurements compared with CT-derived measurements but may systematically overestimate total hip BMD. Further validation studies are warranted.

  • Learning Quantitative Calibration of Computed Tomography for Bone Mineral Density Estimation Using Multi-Center Data

    by Job H. J. Schöller, Yi Gu, Keisuke Uemura, Masaki Takao, Seiji Okada, Nobuhiko Sugano, Yoshinobu Sato, Yoshito Otake

  • Automated framework for volumetric musculoskeletal segmentation and assessment of torso CT images in large-scale databases

    by Sanaa Amina Gourine, Mazen Soufi, Yoshito Otake, Yuto Masaki, Yoko Murakami, Yukihiro Nagatani, Yoshiyuki Watanabe, Keisuke Uemura, Kohei Kono, Masaki Takao, et al.

  • Feasibility and accuracy of low-angle, non-orthogonal biplane fluoroscopic 2D–3D registration for dynamic analysis of the thumb carpometacarpal joint

    by Ryoya Shiode, Satoshi Miyamura, Tasuku Miyake, Hiroki Kondo, Toru Iwahashi, Hiroyuki Tanaka, Yoshito Otake, Yoshinobu Sato, Tsuyoshi Murase, Seiji Okada, et al.

    Background. Accurate three-dimensional dynamic assessment of the thumb carpometacarpal (CMC) joint is important for understanding the pathomechanics of CMC osteoarthritis and evaluating treatment outcomes. Intensity-based biplane 2D–3D registration is a promising approach for dynamic bone motion analysis; however, conventional orthogonal biplane configurations are often difficult to implement for small-joint imaging in clinical settings. Methods. We validated the accuracy of intensity-based biplane 2D–3D registration for thumb CMC joint kinematic analysis using a phantom model under a low-angle, non-orthogonal biplane fluoroscopic configuration (53°). Registration-derived bone poses were compared with radiostereometric analysis-derived ground truth across 252 biplane fluoroscopic image pairs during palmar and radial abduction tasks. Translational and rotational errors were calculated for the thumb proximal phalanx, first metacarpal, trapezium, and second metacarpal. Results. The method achieved submillimeter mean overall component-wise translational errors for all evaluated bones (range: 0.11–0.31 mm). Mean overall component-wise rotational errors were below 3° for all bones (range: 0.44–2.64°). Larger axis-specific rotational root mean square errors were observed for the trapezium and thumb proximal phalanx, reflecting bone- and axis-dependent error patterns. Conclusion. Intensity-based biplane 2D–3D registration can provide sufficient accuracy for dynamic analysis of the thumb CMC joint using a low-angle, non-orthogonal biplane configuration. This approach may serve as a clinically feasible platform for assessing small-joint kinematics in settings where conventional orthogonal biplane systems are difficult to implement, supporting future in vivo studies of dynamic thumb CMC joint motion.

  • Open Access

    Left-right relationship-aware 3D volume classification method

    by Masahiro Oda, Yuichiro Hayashi, Yoshito Otake, Masahiro Hashimoto, Toshiaki Akashi, Shigeki Aoki, Kensaku Mori

    Purpose: This paper proposes a left-right (LR) relationship-aware classification model for 3D volumetric images (3D volume). Bilateral symmetry (LR relationship) is an essential property of the human body that can be used to detect abnormalities and understand anatomical structures. Checking the difference and similarity between the left and right anatomical structures is very important in diagnosis. We propose an LR relationship-aware classification model of 3D volume. Methods: The proposed model employs an image feature extraction process from LR symmetric positions of human anatomy from 3D volume. Due to variations in body position and individual anatomical structure, small positional gaps among LR corresponding anatomical structures can be observed in medical images. We developed a multi-shift symmetric feature extraction module to accommodate such positional gaps. Results: The model was applied to 3D volume classification tasks of the lung and brain. From experimental results, the proposed model achieved superior performances both in the lung and brain classification tasks compared to the previous models. The result indicates that the proposed model has generalized performance in classifying anatomical structures with bilateral symmetric or semi-symmetric structures. Conclusion: We proposed the LR relationship-aware classification model of 3D volume. The proposed model effectively extracts image features from LR symmetric positions. The multi-shift symmetric feature extraction module was employed to accommodate small positional gaps among LR corresponding positions. The experimental results of 3D volume classification tasks of the lung and brain showed that the proposed method achieved superior performances compared to the previous models. Our code is available at https://github.com/modafone/lr3dvolumeclassification .

  • Open Access

    Four-dimensional analysis of swallowing based on hyoid bone kinematics using deep learning-based automatic segmentation

    by Rika Sano, Yuko Shigeta, Tomoko Ikawa, Takuya Kihara, Shuji Shigemoto, Takahiro Kikuchi, Yukihiro Michiwaki, Yoshinobu Sato, Yoshito Otake, Takumi Ogawa

    Purpose: Swallowing is a complex biomechanical process requiring coordinated action of multiple anatomical structures. Traditional analyses classify swallowing into four functional phases based on bolus transit, but lack precise structural correlations. This study aimed to evaluate swallowing dynamics by redefining phase classification according to hyoid bone kinematics and visualizing coordinated motion of swallowing-related organs using four-dimensional computed tomography (4D-CT) and deep learning-based segmentation.Methods: Ten healthy adults (aged 26-66 years) underwent 4D-CT scanning during mastication and swallowing of contrast-enhanced gummy jellies. A deep learning model based on the nnU-Net framework automatically segmented nine anatomical structures, including the hyoid bone, tongue, and soft palate. Swallowing phases were redefined using four static hyoid positions (SP1-SP4) and their corresponding dynamic intervals (SS1-SS4).Results: The 4D-CT analysis successfully visualized dynamic movements of the hyoid bone, epiglottis, and other soft tissues across all stages. In most subjects, velopharyngeal closure by soft palate elevation was observed during SP2, and subsequently, the food bolus entered the pharynx during anterior hyoid translation (SP3). In elderly subjects wearing removable complete dentures and in those with posterior tooth loss, premature or delayed pharyngeal entry suggested altered coordination due to oral condition.Conclusion: This study presents a hyoid-based classification framework for swallowing analysis. The approach, integrating 4D-CT with deep learning, provides higher structural and temporal resolution than conventional videofluoroscopy, yielding new insight into velopharyngeal timing and enhancing understanding of age-related and pathological swallowing variations, with potential applications in prosthodontics and oral rehabilitation.

  • Lower-limb muscle mass quantification and whole-body muscle loss detection using preoperative computed tomography images in patients with hip disease

    by Kono Sotaro, Keisuke Uemura, Mazen Soufi, Ryosuke Nishimura, Takuma Miyamoto, Ryo Higuchi, Hirokazu Mae, Kazuma Takashima, Yoshito Otake, Yasuhito Tanaka, et al.

    Purpose This study developed a method for assessing lower-limb lean mass measured by dual-energy X-ray absorptiometry (DXA-LMleg), using lower-limb muscle mass derived from computed tomography images (CT-MM). Further, the diagnostic performance of the model in detecting whole-body muscle mass (MM) loss, a key component in the assessment of sarcopenia, was evaluated using CT-MM to facilitate the timely initiation of treatment as needed. Methods This retrospective study enrolled 227 patients who underwent hip surgery at two institutions. A deep neural network (DNN)-based method was employed in segmenting lower-limb CT images taken for surgical planning, and the CT-MM was calculated using two different density conversion methods: CT-MM1 (CT-MM calculated using the conventional method) and CT-MM2 (CT-MM calculated using the method by Aubrey et al.). Both CT-MMs were correlated with DXA-LMleg, and receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic accuracy of CT-MMs in detecting whole-body MM loss. Results In 222 cases that were successfully automatically analyzed, strong correlations were observed between CT-MM1 and DXA-LMleg (rs = 0.92–0.96) and between CT-MM2 and DXA-LMleg (rs = 0.86–0.92). ROC curve analysis revealed high diagnostic accuracy for whole-body MM loss (CT-MM1, area under the curve (AUC) = 0.96–0.97; CT-MM2, AUC = 0.91–0.93), with CT-MM1 demonstrating significantly better performance. Conclusion CT-MMs were strongly correlated with DXA-LMleg and had a high diagnostic performance (AUC > 0.9) in detecting whole-body MM loss, supporting sarcopenia screening and preoperative clinical decision-making using routine CT scan.


  • Estimating Bone Mineral Density and Muscle Mass from EOS Low Dose X-Ray Imaging System

    by Kazuki Suehara, Yi Gu, Yoshito Otake, Keisuke Uemura, Masashi Okamoto, Kunihiko Tokunaga, Hugues Talbot, Yoshinobu Sato