Songxiong Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Songxiong Ding has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Binbin Li
College of Materials Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
2 shared publications - Arild Saasen
University of Stavanger
1 shared publication - Haidar Hosamo
Department of Built Environment, Oslo Metropolitan University (OsloMet), 0130 Oslo, Norway
1 shared publication - Haihong Fan
College of Materials Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication - Haihong Fan
College of Science, Northwest A & F University, Yangling, P. R. China
1 shared publication - Iyad Sliteen
Department of Civil Engineering, University of Tishreen, SY02 Latakia, Syria
1 shared publication
Latest Publications
- Open Access
Influence of Temperature on Characteristics of Particulate Matter and Ecological Risk Assessment of Heavy Metals during Sewage Sludge Pyrolysis
The formation process of Particulate Matter (PM) during sludge pyrolysis at different temperatures (300–700 °C) and the ecological risks of heavy metals were studied. The results showed that the particulate matter is mainly condensed on the quartz film in a carbon-based organic matter when the pyrolysis temperature was between 200–500 °C in a volatilization process. Inorganic particles was found in the particulate matter when the temperature was raised to 500–700 °C in a decomposition stage. Heavy metals were enriched in particulate matter with increase in pyrolysis temperature. When the temperature reached 700 °C, the concentration of Pb and Cd in the particulate matter significantly increased. The ecological risk assessment showed that heavy metals in the sewage sludge had considerable ecological toxicity. When the pyrolysis temperature reached 700 °C, the ecological toxicity of those heavy metals enriched in the particulate matter decreased considerably.
Open AccessInfluence of Temperature on Characteristics of Particulate Matter and Ecological Risk Assessment of Heavy Metals during Sewage Sludge Pyrolysis
The formation process of Particulate Matter (PM) during sludge pyrolysis at different temperatures (300–700 °C) and the ecological risks of heavy metals were studied. The results showed that the particulate matter is mainly condensed on the quartz film in a carbon-based organic matter when the pyrolysis temperature was between 200–500 °C in a volatilization process. Inorganic particles was found in the particulate matter when the temperature was raised to 500–700 °C in a decomposition stage. Heavy metals were enriched in particulate matter with increase in pyrolysis temperature. When the temperature reached 700 °C, the concentration of Pb and Cd in the particulate matter significantly increased. The ecological risk assessment showed that heavy metals in the sewage sludge had considerable ecological toxicity. When the pyrolysis temperature reached 700 °C, the ecological toxicity of those heavy metals enriched in the particulate matter decreased considerably.
- Open Access
Numerical Analysis of Bearing Capacity of a Ring Footing on Geogrid Reinforced Sand
A ring footing is found to be of practical importance in supporting symmetrical constructions for example silos, oil storage container etc. In the present paper, numerical analysis was carried out with explicit code FLAC3D 7.0 to investigate bearing capacity of a ring footing on geogrid reinforced sand. Effects of the ratio n of its inner/outer diameter (Di/D) of a ring footing, an optimum depth to lay the geogrid layer were examined. It was found that an intersection zone was developed in soil under inner-side (aisle) of ring footing, contributing to its bearing capacity. Substantial increase of bearing capacities could be realized if ratio n of a ring footing was around 0.6. Numerical results also showed that, bearing capacity of a ring footing could increase significantly if a single-layer geogrid was laid at a proper depth under the footing. Similar contribution was found if a double-layer geogrid was implemented. However, such increases appeared to be rather limited if a triple-layer geogrid or a four-layer geogrid was used. A double-layer geogrid was recommended to increase the bearing capacity of a ring footing; the depth to lay this double-layer geogrid was also discussed.
Open AccessNumerical Analysis of Bearing Capacity of a Ring Footing on Geogrid Reinforced Sand
A ring footing is found to be of practical importance in supporting symmetrical constructions for example silos, oil storage container etc. In the present paper, numerical analysis was carried out with explicit code FLAC3D 7.0 to investigate bearing capacity of a ring footing on geogrid reinforced sand. Effects of the ratio n of its inner/outer diameter (Di/D) of a ring footing, an optimum depth to lay the geogrid layer were examined. It was found that an intersection zone was developed in soil under inner-side (aisle) of ring footing, contributing to its bearing capacity. Substantial increase of bearing capacities could be realized if ratio n of a ring footing was around 0.6. Numerical results also showed that, bearing capacity of a ring footing could increase significantly if a single-layer geogrid was laid at a proper depth under the footing. Similar contribution was found if a double-layer geogrid was implemented. However, such increases appeared to be rather limited if a triple-layer geogrid or a four-layer geogrid was used. A double-layer geogrid was recommended to increase the bearing capacity of a ring footing; the depth to lay this double-layer geogrid was also discussed.
- Open Access
Experimental Investigation into the Effect of Pyrolysis on Chemical Forms of Heavy Metals in Sewage Sludge Biochar (SSB), with Brief Ecological Risk Assessment
Experimental investigations were carried out to study the effect of pyrolysis temperature on the characteristics, structure and total heavy metal contents of sewage sludge biochar (SSB). The changes in chemical forms of the heavy metals (Zn, Cu, Cr, Ni, Pb and Cd) caused by pyrolysis were analyzed, and the potential ecological risk of heavy metals in biochar (SSB) was evaluated. The conversion of sewage sludge into biochar by pyrolysis reduced the H/C and O/C ratios considerably, resulting in stronger carbonization and a higher degree of aromatic condensation in biochar. Measurement results showed that the pH and specific surface area of biochar increased as the pyrolysis temperature increased. It was found that elements Zn, Cu, Cr and Ni were enriched and confined in biochar SSB with increasing pyrolysis temperature from 300–700 °C; however, the residual rates of Pb and Cd in biochar SSB decreased significantly when the temperature was increased from 600 °C to 700 °C. Measurement with the BCR sequential extraction method revealed that the pyrolysis of sewage sludge at a suitable temperature transferred its bioavailable/degradable heavy metals into a more stable oxidizable/residual form in biochar SSB. Toxicity of heavy metals in biochar SSB could be reduced about four times if sewage sludge was pyrolyzed at a proper temperature; heavy metals confined in sludge SSB pyrolyzed at about 600 °C could be assessed as being low in ecological toxicity.
Open AccessExperimental Investigation into the Effect of Pyrolysis on Chemical Forms of Heavy Metals in Sewage Sludge Biochar (SSB), with Brief Ecological Risk Assessment
Experimental investigations were carried out to study the effect of pyrolysis temperature on the characteristics, structure and total heavy metal contents of sewage sludge biochar (SSB). The changes in chemical forms of the heavy metals (Zn, Cu, Cr, Ni, Pb and Cd) caused by pyrolysis were analyzed, and the potential ecological risk of heavy metals in biochar (SSB) was evaluated. The conversion of sewage sludge into biochar by pyrolysis reduced the H/C and O/C ratios considerably, resulting in stronger carbonization and a higher degree of aromatic condensation in biochar. Measurement results showed that the pH and specific surface area of biochar increased as the pyrolysis temperature increased. It was found that elements Zn, Cu, Cr and Ni were enriched and confined in biochar SSB with increasing pyrolysis temperature from 300–700 °C; however, the residual rates of Pb and Cd in biochar SSB decreased significantly when the temperature was increased from 600 °C to 700 °C. Measurement with the BCR sequential extraction method revealed that the pyrolysis of sewage sludge at a suitable temperature transferred its bioavailable/degradable heavy metals into a more stable oxidizable/residual form in biochar SSB. Toxicity of heavy metals in biochar SSB could be reduced about four times if sewage sludge was pyrolyzed at a proper temperature; heavy metals confined in sludge SSB pyrolyzed at about 600 °C could be assessed as being low in ecological toxicity.
- Open Access
Modeling of the Thermal Efficiency of a Whole Cement Clinker Calcination System and Its Application on a 5000 MT/D Production Line
This paper proposes that the scope of research should be extended to the whole clinker calcination system from its single device or specific process (i.e., its functional subunits) as conventionally conducted. Mass/heat flow and effective heat were first analyzed to obtain the thermal efficiencies of its subunits (φi); a thermal efficiency model of the whole system φQY was thus established by correlating the relationship between φi and φQY. The thermal efficiency model of the whole system showed that φi had a positive linear correlation with φQY; it was found that the thermal efficiency of the decomposition and clinker calcination unit (φDC) had the greatest weight on φQY, where a 1% increase in φDC led to a 1.73% increase in φQY—improving φDC was shown to be the most effective way to improve φQY. In this paper, the developed thermal efficiency model was applied to one 5000 MT/D production line. It was found that its φQY was only 61.70%—about 2.35% lower than a representative line; such decrease was caused by its low φDC and φP which, as disclosed by model, were derived from the low decomposition rate of calcium carbonate in preheated meal put into a calciner and the high excess air coefficient of secondary air. Controlled parameter optimization of this 5000 MT/D production line was then carried out. As a result, the φDC and φP of the production line were increased from 30.03% and 64.61% to 30.69% and 65.69%, respectively; the φQY increased from 61.70% to 62.55%; the clinker output of the production line increased from 5799 MT/D to 5968 MT/D; the heat consumption of clinker was reduced from 3286.98 kJ/kg·cl to 3252.41 kJ/kg·cl.
Open AccessModeling of the Thermal Efficiency of a Whole Cement Clinker Calcination System and Its Application on a 5000 MT/D Production Line
This paper proposes that the scope of research should be extended to the whole clinker calcination system from its single device or specific process (i.e., its functional subunits) as conventionally conducted. Mass/heat flow and effective heat were first analyzed to obtain the thermal efficiencies of its subunits (φi); a thermal efficiency model of the whole system φQY was thus established by correlating the relationship between φi and φQY. The thermal efficiency model of the whole system showed that φi had a positive linear correlation with φQY; it was found that the thermal efficiency of the decomposition and clinker calcination unit (φDC) had the greatest weight on φQY, where a 1% increase in φDC led to a 1.73% increase in φQY—improving φDC was shown to be the most effective way to improve φQY. In this paper, the developed thermal efficiency model was applied to one 5000 MT/D production line. It was found that its φQY was only 61.70%—about 2.35% lower than a representative line; such decrease was caused by its low φDC and φP which, as disclosed by model, were derived from the low decomposition rate of calcium carbonate in preheated meal put into a calciner and the high excess air coefficient of secondary air. Controlled parameter optimization of this 5000 MT/D production line was then carried out. As a result, the φDC and φP of the production line were increased from 30.03% and 64.61% to 30.69% and 65.69%, respectively; the φQY increased from 61.70% to 62.55%; the clinker output of the production line increased from 5799 MT/D to 5968 MT/D; the heat consumption of clinker was reduced from 3286.98 kJ/kg·cl to 3252.41 kJ/kg·cl.
- 12 May 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 138 (5) , 052907
The Shielding Effect of Drilling Fluids on Measurement While Drilling Tool Downhole Compasses—The Effect of Drilling Fluid Composition, Contaminants, and Rheology
Materials such as added clays, weight materials, drill solids, and metallic wear products in the drilling fluid are known to distort the geomagnetic field at the location of the measurement while drilling (MWD) tool magnetometers that are used to measure the direction of well path. This distortion contributes to substantial errors in determination of azimuth while drilling deviated wells. These errors may result in missing the target of a long deviated 12 ¼ in. section in the range of 1–200 m, representing a significant cost to be mitigated. The error becomes even more pronounced if drilling occurs in arctic regions close to the magnetic north pole (or south pole). The effect on the magnetometer readings is obviously linked to the kinds and amounts of magnetic materials in the drilling fluid. The problem has recently been studied by laboratory experiments and analyses of downhole survey data. A series of experiments has been carried out to understand how some drilling fluid additives relate to the magnetic distortion. Experiments with free iron ions show that presence of iron ions does not contribute to magnetic distortion, while experiments with bentonite-based fluids show a strong effect of bentonite on magnetic shielding. Albeit earlier measurements showing a strong dependency of the content of organophilic clay, clean laboratory prepared oil-based drilling fluids show no increased shielding when adding organophilic hectorite clays. The anticipated difference between these two cases is outlined in the paper. When eroded steel from an offshore drilling site is added into the oil-based drilling fluid, it is found that these swarf and steel fines significantly increase the magnetic shielding of the drilling fluid. The paper outlines how the drilling direction may be distorted by the presence of these additives and contaminants and how this relates to the rheological properties of the drilling fluid.
- 12 May 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 138 (5) , 052907
The Shielding Effect of Drilling Fluids on Measurement While Drilling Tool Downhole Compasses—The Effect of Drilling Fluid Composition, Contaminants, and Rheology
Materials such as added clays, weight materials, drill solids, and metallic wear products in the drilling fluid are known to distort the geomagnetic field at the location of the measurement while drilling (MWD) tool magnetometers that are used to measure the direction of well path. This distortion contributes to substantial errors in determination of azimuth while drilling deviated wells. These errors may result in missing the target of a long deviated 12 ¼ in. section in the range of 1–200 m, representing a significant cost to be mitigated. The error becomes even more pronounced if drilling occurs in arctic regions close to the magnetic north pole (or south pole). The effect on the magnetometer readings is obviously linked to the kinds and amounts of magnetic materials in the drilling fluid. The problem has recently been studied by laboratory experiments and analyses of downhole survey data. A series of experiments has been carried out to understand how some drilling fluid additives relate to the magnetic distortion. Experiments with free iron ions show that presence of iron ions does not contribute to magnetic distortion, while experiments with bentonite-based fluids show a strong effect of bentonite on magnetic shielding. Albeit earlier measurements showing a strong dependency of the content of organophilic clay, clean laboratory prepared oil-based drilling fluids show no increased shielding when adding organophilic hectorite clays. The anticipated difference between these two cases is outlined in the paper. When eroded steel from an offshore drilling site is added into the oil-based drilling fluid, it is found that these swarf and steel fines significantly increase the magnetic shielding of the drilling fluid. The paper outlines how the drilling direction may be distorted by the presence of these additives and contaminants and how this relates to the rheological properties of the drilling fluid.