  • A Prospective, Randomized Study Evaluating Clinical and Radiographic Efficacy of Lumbar Interbody Fusion Performed Using a Truss Technology–Based Interbody Fusion Device With Homologous Bone or Bone Marrow Aspirate

    by Benjamin Chatterjee, Michael Rauschmann, Christoph Fleege, Mohammad Arabmotlagh, Sven Schmidt, Kimberly Martin, Marcus Rickert

    Background Our group used vertebral bone marrow aspirate (BMA) with an anterior truss-based interbody implant to promote fusion. This implant has biomechanical characteristics that may enhance bone on-growth and through-growth and allow for the use of BMA clot alone. The primary end point was comparison of the proportion of patients who achieved fusion with the implant packed with either crushed cancellous homologous bone chips (CCB) alone or with BMA clot alone. Methods Patients were randomized to receive either BMA clot or CCB in the implant. Both groups also had supplemental fixation. Clinical assessments were performed preoperatively and postoperatively at 3, 6, and 12 months, including for the Oswestry Disability Index, leg and back visual analog scale, EQ5-D, reoperations, complications, and adverse events. Radiographs were obtained prior to discharge and at 3, 6, and 12 months postoperatively. A computed tomography scan was performed 3 months postoperatively. Radiographs were assessed by an independent radiologist to determine fusion status and evidence of subsidence. Results Between January 2015 and February 2016, 42 consecutive patients were randomized into 1 of the 2 study groups. There were significant postoperative changes within both groups in pain improvement across all outcome scales. There were no significant differences between groups in change scores from preoperative to assessments at any follow-up time point, with the exception of the change in EQ-5D and visual analog scale at 6 months; however, there was no difference at 3 or 12 months. There were no device-related adverse events in either group. All patients achieved grade II fusion at 3 months postoperatively. There was no significant difference in implant subsidence between groups or smokers versus nonsmokers. Conclusions The clinical outcomes of this study suggest that reliable fusion can be obtained using an anterior truss-based implant with either CCB or BMA alone. Level of Evidence 2.


  • Quantifying inadvertent thermal bowel injury from the monopolar instrument

    by Kimberly E. Martin, Camille M. Moore, Robert Tucker, Pascal Fuchshuber, Thomas Robinson

    Background Insulation defects are observed in 3–39 % of laparoscopic instruments. Electrosurgical injuries due to insulation defects or capacitive coupling remain an issue in laparoscopic surgery with a prevalence of 0.6–5 per thousand cases. Shielded instruments with active electrode monitoring (AEM) have been postulated to prevent these injuries. The benefit of these instruments has not been quantified. Most bowel injuries are unrecognized intra-operatively. Injury is revealed only after the patient exhibits peritonitis symptoms and surgical intervention to repair the bowel is required. These injuries may result in devastating and costly complications or mortality. The extent of bowel injury possible with commonly used generator settings and associated energy output has never been histologically defined. Our objectives in this experimental study were: quantify and compare the energy released through insulation defects or capacitive coupling with standard unshielded monopolar versus shielded instruments with (AEM), determine energy required to cause a visible burn, and relate the histological burn depth to a given amount of energy. Methods Ex vivo porcine jejunum was used for tissue testing. An oscilloscope measured energy output from three common electrosurgical generators at recommended power settings with standard or AEM instruments with insulation defects and in capacitive coupling scenarios. Presence of a visible burn was noted, and depth of tissue damage for a given amount of energy was measured histologically. Results All samples that received ≥3.8 J of energy had visible burns. As little as 10 J caused full wall thickness burns. 3.8 J was exceeded at the 30- and 50-W power settings in every experimental scenario using standard monopolar instruments; AEM instruments never approached this much energy. Conclusions Serious burn injury results from small amounts of energy leaked from standard instruments. AEM instruments appeared protective and did not leak sufficient energy to cause burn injuries to the bowel.


  • The impact of atherosclerosis and vascular collagen on energy-based vessel sealing

    by Kimberly Martin, Kimberly Krugman, Cassandra Latimer, Camille Moore