Maki Izawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maki Izawa has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Iwawaki
Division of Forensic Odontology, Department of Diagnostic and Therapeutic Sciences, Meikai University School of Dentistry, Saitama, Japan
2 shared publications - Hideki Saka
Forensic Odontology Center, Meikai University School of Dentistry , 1-1 Keyakidai, Sakado, Saitama 350-0283 , Japan
2 shared publications Nobutoshi Takahashi
Division of Dental Radiology , Department of Diagnostic and Therapeutic Sciences 1-1 Keyakidai, Sakado, Saitama 350-0283 , Japan
2 shared publicationsNoriyoshi Shiba
Division of Dental Radiology , Department of Diagnostic and Therapeutic Sciences 1-1 Keyakidai, Sakado, Saitama 350-0283 , Japan
2 shared publications- Shinji Kito
Division of Dental Radiology , Department of Diagnostic and Therapeutic Sciences 1-1 Keyakidai, Sakado, Saitama 350-0283 , Japan
2 shared publications - Takeru Ishii
Division of Forensic Odontology , Department of Diagnostic and Therapeutic Sciences 1-1 Keyakidai, Sakado, Saitama 350-0283 , Japan
2 shared publications
Latest Publications
- 31 August 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (19) , 2349-2355
Stray radiation dose reduction using a backscatter shield and a rectangular collimator for a handheld intraoral X-ray unit
The objective of this study was to study the dose reduction effect on occupational exposure of operators and public exposure other than operators when a backscatter shield and a rectangular collimator are used in conjunction with a handheld intraoral X-ray unit. The occupational exposure was reduced to 40% when the backscatter shield was attached to the cone-tip, to 13% when the rectangular collimator was attached and to 7.7% when the backscatter shield and rectangular collimator were used together. On the other hand, the public exposure was reduced to 20% when the rectangular collimator was attached, but the backscatter shield was not effective in reducing the public exposure. Attaching a backscatter shield is effective in reducing the occupational exposure, and a rectangular aperture is effective in reducing the occupational exposure, as well as the public exposure.
- 31 August 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (19) , 2349-2355
Stray radiation dose reduction using a backscatter shield and a rectangular collimator for a handheld intraoral X-ray unit
The objective of this study was to study the dose reduction effect on occupational exposure of operators and public exposure other than operators when a backscatter shield and a rectangular collimator are used in conjunction with a handheld intraoral X-ray unit. The occupational exposure was reduced to 40% when the backscatter shield was attached to the cone-tip, to 13% when the rectangular collimator was attached and to 7.7% when the backscatter shield and rectangular collimator were used together. On the other hand, the public exposure was reduced to 20% when the rectangular collimator was attached, but the backscatter shield was not effective in reducing the public exposure. Attaching a backscatter shield is effective in reducing the occupational exposure, and a rectangular aperture is effective in reducing the occupational exposure, as well as the public exposure.
- Open Access
- 3 July 2023
- Published by International Institute of Anticancer Research in In Vivo
- Vol. 37 (4) , 1540-1551
Comprehensive Study of Anti-UVC Activity and Cytotoxicity of Hot-water Soluble Herb Extracts
Background/Aim: COVID-19 pandemic caused the rapid dissemination of ultraviolet C (UVC) sterilization apparatuses. Prolonged exposure to UVC, however, may exert harmful effects on the human body. The aim of the present study was to comprehensively investigate the anti-UVC activity of a total of 108 hot-water soluble herb extracts, using human dermal fibroblast and melanoma cell lines, for the future development of skin care products. Materials and Methods: Exposure time to UVC was set to 3 min, and cell viability was determined using the MTT assay. Anti-UVC activity was determined using the selective index (SI), a ratio of 50% cytotoxic concentration for unirradiated cells to 50% effective concentration that restored half of the UVC-induced decrease of viability. Results: Dermal fibroblasts at any population doubling level were more resistant to UVC irradiation than melanoma cells. Both 49 herb extracts recommended by Japan Medical Herb Association (JAMHA) and 59 additional herb extracts showed comparable anti-UVC activity. SI values of selected herbs (Butterbur, Cloves, Curry Tree, Evening Primrose, Rooibos, Stevia, Willow) were several-fold lower than those of vitamin C and vanillin. Their potent anti-UVC activity was maintained for at least 6 h post irradiation, but declined thereafter to the basal level, possibly due to cytotoxic ingredients. Conclusion: UVC sensitivity may be related to the growth potential of target cells. Removal of cytotoxic ingredients of herb extracts may further potentiate and prolong their anti-UVC activity.
- 3 July 2023
- Published by International Institute of Anticancer Research in In Vivo
- Vol. 37 (4) , 1540-1551
Open AccessComprehensive Study of Anti-UVC Activity and Cytotoxicity of Hot-water Soluble Herb Extracts
Background/Aim: COVID-19 pandemic caused the rapid dissemination of ultraviolet C (UVC) sterilization apparatuses. Prolonged exposure to UVC, however, may exert harmful effects on the human body. The aim of the present study was to comprehensively investigate the anti-UVC activity of a total of 108 hot-water soluble herb extracts, using human dermal fibroblast and melanoma cell lines, for the future development of skin care products. Materials and Methods: Exposure time to UVC was set to 3 min, and cell viability was determined using the MTT assay. Anti-UVC activity was determined using the selective index (SI), a ratio of 50% cytotoxic concentration for unirradiated cells to 50% effective concentration that restored half of the UVC-induced decrease of viability. Results: Dermal fibroblasts at any population doubling level were more resistant to UVC irradiation than melanoma cells. Both 49 herb extracts recommended by Japan Medical Herb Association (JAMHA) and 59 additional herb extracts showed comparable anti-UVC activity. SI values of selected herbs (Butterbur, Cloves, Curry Tree, Evening Primrose, Rooibos, Stevia, Willow) were several-fold lower than those of vitamin C and vanillin. Their potent anti-UVC activity was maintained for at least 6 h post irradiation, but declined thereafter to the basal level, possibly due to cytotoxic ingredients. Conclusion: UVC sensitivity may be related to the growth potential of target cells. Removal of cytotoxic ingredients of herb extracts may further potentiate and prolong their anti-UVC activity.
- 30 June 2020
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 13 (3) , 312-320
Reduction of operator exposure by rectangular collimation in portable intraoral radiography
Portable intraoral X-ray units are frequently used for home-visit dental treatment and personal dental identification. Therefore, the reduction of operator exposure is crucial. Rectangular collimation is effective at reducing patient exposure and operator exposure; however, its effects are not known. We investigated the reduction of operator exposure through rectangular collimation by measuring the backscattered dose in relation to the operator exposure dose. Using a portable intraoral X-ray unit, a head phantom for CT dose measurement as the object, a dosimeter, and stainless-steel rectangular collimator, a 1-cm ambient dose equivalent was measured in intervals of 15° in horizontal and vertical planes with the radii of 50 and 100 cm. The backscattered dose decreased to approximately one-third when a rectangular collimator was attached to the cone tip. This may have been due to the reduction of the volume of scattered X-rays generated in the phantom by rectangular collimation. We clarified that rectangular collimation is effective at reducing the operator exposure and is useful for protecting the operators of portable intraoral X-ray units during home-visit dental treatment and personal dental identification.
- 30 June 2020
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 13 (3) , 312-320
Reduction of operator exposure by rectangular collimation in portable intraoral radiography
Portable intraoral X-ray units are frequently used for home-visit dental treatment and personal dental identification. Therefore, the reduction of operator exposure is crucial. Rectangular collimation is effective at reducing patient exposure and operator exposure; however, its effects are not known. We investigated the reduction of operator exposure through rectangular collimation by measuring the backscattered dose in relation to the operator exposure dose. Using a portable intraoral X-ray unit, a head phantom for CT dose measurement as the object, a dosimeter, and stainless-steel rectangular collimator, a 1-cm ambient dose equivalent was measured in intervals of 15° in horizontal and vertical planes with the radii of 50 and 100 cm. The backscattered dose decreased to approximately one-third when a rectangular collimator was attached to the cone tip. This may have been due to the reduction of the volume of scattered X-rays generated in the phantom by rectangular collimation. We clarified that rectangular collimation is effective at reducing the operator exposure and is useful for protecting the operators of portable intraoral X-ray units during home-visit dental treatment and personal dental identification.
- Open Access
- 3 May 2016
- Published by Springer Nature in Oral Radiology
- Vol. 33 (1) , 38-44
Establishment of local diagnostic reference levels for quality control in intraoral radiography
To investigate the dosage and imaging conditions for patients undergoing intraoral radiography at Meikai University Hospital and establish assurance and quality control data.
- 3 May 2016
- Published by Springer Nature in Oral Radiology
- Vol. 33 (1) , 38-44
Open AccessEstablishment of local diagnostic reference levels for quality control in intraoral radiography
To investigate the dosage and imaging conditions for patients undergoing intraoral radiography at Meikai University Hospital and establish assurance and quality control data.