Hideki Saka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hideki Saka has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Iwawaki
Division of Forensic Odontology, Department of Diagnostic and Therapeutic Sciences, Meikai University School of Dentistry, Saitama, Japan
2 shared publications - Maki Izawa
Division of Dental Radiology, Department of Diagnostic and Therapeutic Sciences, Meikai University School of Dentistry, Saitama, Japan
2 shared publications - Shinji Kito
Division of Dental Radiology , Department of Diagnostic and Therapeutic Sciences 1-1 Keyakidai, Sakado, Saitama 350-0283 , Japan
2 shared publications - Takeru Ishii
Division of Forensic Odontology , Department of Diagnostic and Therapeutic Sciences 1-1 Keyakidai, Sakado, Saitama 350-0283 , Japan
2 shared publications - Yasuo Harata
Division of Dental Radiology , Department of Diagnostic and Therapeutic Sciences 1-1 Keyakidai, Sakado, Saitama 350-0283 , Japan
2 shared publications - Yusei Otaka
Division of Dental Radiology, Department of Diagnostic and Therapeutic Sciences, Meikai University School of Dentistry, Saitama, Japan; Forensic Odontology Center, Meikai University School of Dentistry, Saitama, Japan
2 shared publications
Latest Publications
- 31 August 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (19) , 2349-2355
Stray radiation dose reduction using a backscatter shield and a rectangular collimator for a handheld intraoral X-ray unit
The objective of this study was to study the dose reduction effect on occupational exposure of operators and public exposure other than operators when a backscatter shield and a rectangular collimator are used in conjunction with a handheld intraoral X-ray unit. The occupational exposure was reduced to 40% when the backscatter shield was attached to the cone-tip, to 13% when the rectangular collimator was attached and to 7.7% when the backscatter shield and rectangular collimator were used together. On the other hand, the public exposure was reduced to 20% when the rectangular collimator was attached, but the backscatter shield was not effective in reducing the public exposure. Attaching a backscatter shield is effective in reducing the occupational exposure, and a rectangular aperture is effective in reducing the occupational exposure, as well as the public exposure.
- 31 August 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (19) , 2349-2355
Stray radiation dose reduction using a backscatter shield and a rectangular collimator for a handheld intraoral X-ray unit
The objective of this study was to study the dose reduction effect on occupational exposure of operators and public exposure other than operators when a backscatter shield and a rectangular collimator are used in conjunction with a handheld intraoral X-ray unit. The occupational exposure was reduced to 40% when the backscatter shield was attached to the cone-tip, to 13% when the rectangular collimator was attached and to 7.7% when the backscatter shield and rectangular collimator were used together. On the other hand, the public exposure was reduced to 20% when the rectangular collimator was attached, but the backscatter shield was not effective in reducing the public exposure. Attaching a backscatter shield is effective in reducing the occupational exposure, and a rectangular aperture is effective in reducing the occupational exposure, as well as the public exposure.
- 30 June 2020
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 13 (3) , 312-320
Reduction of operator exposure by rectangular collimation in portable intraoral radiography
Portable intraoral X-ray units are frequently used for home-visit dental treatment and personal dental identification. Therefore, the reduction of operator exposure is crucial. Rectangular collimation is effective at reducing patient exposure and operator exposure; however, its effects are not known. We investigated the reduction of operator exposure through rectangular collimation by measuring the backscattered dose in relation to the operator exposure dose. Using a portable intraoral X-ray unit, a head phantom for CT dose measurement as the object, a dosimeter, and stainless-steel rectangular collimator, a 1-cm ambient dose equivalent was measured in intervals of 15° in horizontal and vertical planes with the radii of 50 and 100 cm. The backscattered dose decreased to approximately one-third when a rectangular collimator was attached to the cone tip. This may have been due to the reduction of the volume of scattered X-rays generated in the phantom by rectangular collimation. We clarified that rectangular collimation is effective at reducing the operator exposure and is useful for protecting the operators of portable intraoral X-ray units during home-visit dental treatment and personal dental identification.
- 30 June 2020
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 13 (3) , 312-320
Reduction of operator exposure by rectangular collimation in portable intraoral radiography
Portable intraoral X-ray units are frequently used for home-visit dental treatment and personal dental identification. Therefore, the reduction of operator exposure is crucial. Rectangular collimation is effective at reducing patient exposure and operator exposure; however, its effects are not known. We investigated the reduction of operator exposure through rectangular collimation by measuring the backscattered dose in relation to the operator exposure dose. Using a portable intraoral X-ray unit, a head phantom for CT dose measurement as the object, a dosimeter, and stainless-steel rectangular collimator, a 1-cm ambient dose equivalent was measured in intervals of 15° in horizontal and vertical planes with the radii of 50 and 100 cm. The backscattered dose decreased to approximately one-third when a rectangular collimator was attached to the cone tip. This may have been due to the reduction of the volume of scattered X-rays generated in the phantom by rectangular collimation. We clarified that rectangular collimation is effective at reducing the operator exposure and is useful for protecting the operators of portable intraoral X-ray units during home-visit dental treatment and personal dental identification.