F. Brennan Torstrick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
F. Brennan Torstrick has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- David L. Safranski
MedShape, Inc., 1575 Northside Drive, NW, Suite 440, Atlanta, GA 30318, United States
2 shared publications - Nathan T. Evans
School of Materials Science and Engineering, Georgia Institute of Technology, 771 Ferst Drive, J. Erskine Love Building, Atlanta, GA 30332, United States
2 shared publications - Angela S.P. Lin
George W. Woodruff School of Mechanical Engineering, 801 Ferst Drive, Georgia Institute of Technology, Atlanta, GA 30332, USA; Parker H. Petit Institute for Bioengineering and Bioscience, 315 Ferst Drive, Georgia Institute of Technology, Atlanta, GA 30332, USA
1 shared publication - Annie E. Macedo
Wallace H. Coulter Department of Biomedical Engineering, 313 Ferst Drive, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
1 shared publication - Christopher S.D. Lee
Vertera, Inc., 311 Ferst Drive NW Suite L1328, Atlanta, GA 30332, USA
1 shared publication - Daniel C. Whittingslow
Wallace H. Coulter Department of Biomedical Engineering, 313 Ferst Drive, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
1 shared publication
Latest Publications
- 1 January 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 65, 522-532
Local deformation behavior of surface porous polyether-ether-ketone
- 1 January 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 65, 522-532
Local deformation behavior of surface porous polyether-ether-ketone
- 1 November 2016
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 474 (11) , 2373-2383
Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?
Responding decrease in implant strength can potentially reduce the implant's ability to bear physiologic loads. We have previously shown, using a single pore size, that limiting porosity to the surface of PEEK implants preserves strength while supporting in vivo osseointegration. However, additional work is needed to investigate the effect of pore size on both the mechanical properties and cellular response to PEEK. Questions/purposes (1) Can surface porous PEEK (PEEK-SP) microstructure be reliably controlled? (2) What is the effect of pore size on the mechanical properties of PEEK-SP? (3) Do surface porosity and pore size influence the cellular response to PEEK? Methods PEEK-SP was created by extruding PEEK through NaCl crystals of three controlled ranges: 200 to 312, 312 to 425, and 425 to 508 μm. Micro-CT was used to characterize the microstructure of PEEK-SP. Tensile, fatigue, and interfacial shear tests were performed to compare the mechanical properties of PEEK-SP with injection-molded PEEK (PEEK-IM). The cellular response to PEEK-SP, assessed by proliferation, alkaline phosphatase activity, vascular endothelial growth factor production, and calcium content of osteoblast, mesenchymal stem cell, and preosteoblast (MC3T3-E1) cultures, was compared with that of machined smooth PEEK and Ti6Al4V. Results Micro-CT analysis showed that PEEK-SP layers possessed pores that were 284 ± 35 μm, 341 ± 49 μm, and 416 ± 54 μm for each pore size group. Porosity and pore layer depth ranged from 61% to 69% and 303 to 391 μm, respectively. Mechanical testing revealed tensile strengths > 67 MPa and interfacial shear strengths > 20 MPa for all three pore size groups. All PEEK-SP groups exhibited > 50% decrease in ductility compared with PEEK-IM and demonstrated fatigue strength > 38 MPa at one million cycles. All PEEK-SP groups also supported greater proliferation and cell-mediated mineralization compared with smooth PEEK and Ti6Al4V. Conclusions The PEEK-SP formulations evaluated in this study maintained favorable mechanical properties that merit further investigation into their use in load-bearing orthopaedic applications and supported greater in vitro osteogenic differentiation compared with smooth PEEK and Ti6Al4V. These results are independent of pore sizes ranging 200 μm to 508 μm. Clinical Relevance PEEK-SP may provide enhanced osseointegration compared with current implants while maintaining the structural integrity to be considered for several load-bearing orthopaedic applications such as spinal fusion or soft tissue repair....
- 1 November 2016
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 474 (11) , 2373-2383
Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?
Responding decrease in implant strength can potentially reduce the implant's ability to bear physiologic loads. We have previously shown, using a single pore size, that limiting porosity to the surface of PEEK implants preserves strength while supporting in vivo osseointegration. However, additional work is needed to investigate the effect of pore size on both the mechanical properties and cellular response to PEEK. Questions/purposes (1) Can surface porous PEEK (PEEK-SP) microstructure be reliably controlled? (2) What is the effect of pore size on the mechanical properties of PEEK-SP? (3) Do surface porosity and pore size influence the cellular response to PEEK? Methods PEEK-SP was created by extruding PEEK through NaCl crystals of three controlled ranges: 200 to 312, 312 to 425, and 425 to 508 μm. Micro-CT was used to characterize the microstructure of PEEK-SP. Tensile, fatigue, and interfacial shear tests were performed to compare the mechanical properties of PEEK-SP with injection-molded PEEK (PEEK-IM). The cellular response to PEEK-SP, assessed by proliferation, alkaline phosphatase activity, vascular endothelial growth factor production, and calcium content of osteoblast, mesenchymal stem cell, and preosteoblast (MC3T3-E1) cultures, was compared with that of machined smooth PEEK and Ti6Al4V. Results Micro-CT analysis showed that PEEK-SP layers possessed pores that were 284 ± 35 μm, 341 ± 49 μm, and 416 ± 54 μm for each pore size group. Porosity and pore layer depth ranged from 61% to 69% and 303 to 391 μm, respectively. Mechanical testing revealed tensile strengths > 67 MPa and interfacial shear strengths > 20 MPa for all three pore size groups. All PEEK-SP groups exhibited > 50% decrease in ductility compared with PEEK-IM and demonstrated fatigue strength > 38 MPa at one million cycles. All PEEK-SP groups also supported greater proliferation and cell-mediated mineralization compared with smooth PEEK and Ti6Al4V. Conclusions The PEEK-SP formulations evaluated in this study maintained favorable mechanical properties that merit further investigation into their use in load-bearing orthopaedic applications and supported greater in vitro osteogenic differentiation compared with smooth PEEK and Ti6Al4V. These results are independent of pore sizes ranging 200 μm to 508 μm. Clinical Relevance PEEK-SP may provide enhanced osseointegration compared with current implants while maintaining the structural integrity to be considered for several load-bearing orthopaedic applications such as spinal fusion or soft tissue repair....
- 1 February 2015
- Published by Elsevier in Acta Biomaterialia
- Vol. 13, 159-167
High-strength, surface-porous polyether-ether-ketone for load-bearing orthopedic implants
- 1 February 2015
- Published by Elsevier in Acta Biomaterialia
- Vol. 13, 159-167
High-strength, surface-porous polyether-ether-ketone for load-bearing orthopedic implants