Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?
- 1 November 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 474 (11) , 2373-2383
Abstract
Responding decrease in implant strength can potentially reduce the implant's ability to bear physiologic loads. We have previously shown, using a single pore size, that limiting porosity to the surface of PEEK implants preserves strength while supporting in vivo osseointegration. However, additional work is needed to investigate the effect of pore size on both the mechanical properties and cellular response to PEEK. Questions/purposes (1) Can surface porous PEEK (PEEK-SP) microstructure be reliably controlled? (2) What is the effect of pore size on the mechanical properties of PEEK-SP? (3) Do surface porosity and pore size influence the cellular response to PEEK? Methods PEEK-SP was created by extruding PEEK through NaCl crystals of three controlled ranges: 200 to 312, 312 to 425, and 425 to 508 μm. Micro-CT was used to characterize the microstructure of PEEK-SP. Tensile, fatigue, and interfacial shear tests were performed to compare the mechanical properties of PEEK-SP with injection-molded PEEK (PEEK-IM). The cellular response to PEEK-SP, assessed by proliferation, alkaline phosphatase activity, vascular endothelial growth factor production, and calcium content of osteoblast, mesenchymal stem cell, and preosteoblast (MC3T3-E1) cultures, was compared with that of machined smooth PEEK and Ti6Al4V. Results Micro-CT analysis showed that PEEK-SP layers possessed pores that were 284 ± 35 μm, 341 ± 49 μm, and 416 ± 54 μm for each pore size group. Porosity and pore layer depth ranged from 61% to 69% and 303 to 391 μm, respectively. Mechanical testing revealed tensile strengths > 67 MPa and interfacial shear strengths > 20 MPa for all three pore size groups. All PEEK-SP groups exhibited > 50% decrease in ductility compared with PEEK-IM and demonstrated fatigue strength > 38 MPa at one million cycles. All PEEK-SP groups also supported greater proliferation and cell-mediated mineralization compared with smooth PEEK and Ti6Al4V. Conclusions The PEEK-SP formulations evaluated in this study maintained favorable mechanical properties that merit further investigation into their use in load-bearing orthopaedic applications and supported greater in vitro osteogenic differentiation compared with smooth PEEK and Ti6Al4V. These results are independent of pore sizes ranging 200 μm to 508 μm. Clinical Relevance PEEK-SP may provide enhanced osseointegration compared with current implants while maintaining the structural integrity to be considered for several load-bearing orthopaedic applications such as spinal fusion or soft tissue repair....Keywords
Funding Information
- National Science Foundation (2013162284)
- National Center for Advancing Translational Sciences (UL1TR000454)
This publication has 52 references indexed in Scilit:
- A phenotypic comparison of osteoblast cell lines versus human primary osteoblasts for biomaterials testingJournal of Biomedical Materials Research Part A, 2013
- Notch sensitivity of PEEK in monotonic tensionBiomaterials, 2009
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Requirement for both micron- and submicron scale structure for synergistic responses of osteoblasts to substrate surface energy and topographyBiomaterials, 2007
- Does seeding density affect in vitro mineral nodules formation in novel composite scaffolds?Journal of Biomedical Materials Research Part A, 2006
- The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: experimental and finite-element analysisEuropean Spine Journal, 2005
- Direct Three-Dimensional Morphometric Analysis of Human Cancellous Bone: Microstructural Data from Spine, Femur, Iliac Crest, and CalcaneusJournal of Bone and Mineral Research, 1999
- Potential of polyetheretherketone (PEEK) and carbon-fibre-reinforced PEEK in medical applicationsJournal of Materials Science Letters, 1987
- The notch sensitivity of polymeric materialsJournal of Applied Polymer Science, 1976
- Fatigue Behavior of Some Filled PolymersJournal of Composite Materials, 1975