Bakir Babic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Bakir Babic has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
C. Schönenberger
5 shared publicationsJan Herrmann
Nanometrology, National Measurement Institute Australia, PO Box 264, Lindfield, NSW 2070, Lindfield, New South Wales, 2070, AUSTRALIA
5 shared publications- Victoria Anne Coleman
Nanometrology Section, National Measurement Institute Australia, Lindfield, NSW, Australia
4 shared publications - Christian Schönenberger
Department of Physics, University of Basel, Basel, Switzerland
2 shared publications - Rajesh Ghai
The University of Queensland, Institute for Molecular Bioscience, Queensland, 4072, Australia
2 shared publications A. J. Kulik
Institute of Physics of Complex Matter, EPFL, CH-1015 Lausanne, Switzerland
1 shared publication
Latest Publications
- 16 April 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (7) , 075007
Immersive visualisation for a large metrological data set
A purpose of scientific visualisation is to facilitate the extraction of information within underlying data. Visualisation of a large data set requires an appropriate visualisation method where, instead of focusing on expected features, all acquired data are treated on an equal footing. Here, we identify critical differences between raw and processed data acquired from displacement measurements at the nanoscale. We illustrate the strength of immersive data visualisation in rapidly and intuitively identifying non-obvious data trends, supported by correlation with the associated measurement uncertainties. These insights can be directly leveraged for optimisation of instrumentation and measurement protocols, application of appropriate measurement corrections, and iterative experimental design changes.
- 16 April 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (7) , 075007
Immersive visualisation for a large metrological data set
A purpose of scientific visualisation is to facilitate the extraction of information within underlying data. Visualisation of a large data set requires an appropriate visualisation method where, instead of focusing on expected features, all acquired data are treated on an equal footing. Here, we identify critical differences between raw and processed data acquired from displacement measurements at the nanoscale. We illustrate the strength of immersive data visualisation in rapidly and intuitively identifying non-obvious data trends, supported by correlation with the associated measurement uncertainties. These insights can be directly leveraged for optimisation of instrumentation and measurement protocols, application of appropriate measurement corrections, and iterative experimental design changes.
- Open Access
- 16 March 2023
- Published by IOP Publishing in Nanotechnology
- Vol. 34 (22) , 225702
Thickness measurements of graphene oxide flakes using atomic force microscopy: results of an international interlaboratory comparison
Flake thickness is one of the defining properties of graphene-related 2D materials (GR2Ms), and therefore requires reliable, accurate, and reproducible measurements with well-understood uncertainties. This is needed regardless of the production method or manufacturer because it is important for all GR2M products to be globally comparable. An international interlaboratory comparison on thickness measurements of graphene oxide flakes using atomic force microscopy has been completed in technical working area 41 of versailles project on advanced materials and standards. Twelve laboratories participated in the comparison project, led by NIM, China, to improve the equivalence of thickness measurement for two-dimensional flakes. The measurement methods, uncertainty evaluation and a comparison of the results and analysis are reported in this manuscript. The data and results of this project will be directly used to support the development of an ISO standard.
- 16 March 2023
- Published by IOP Publishing in Nanotechnology
- Vol. 34 (22) , 225702
Open AccessThickness measurements of graphene oxide flakes using atomic force microscopy: results of an international interlaboratory comparison
Flake thickness is one of the defining properties of graphene-related 2D materials (GR2Ms), and therefore requires reliable, accurate, and reproducible measurements with well-understood uncertainties. This is needed regardless of the production method or manufacturer because it is important for all GR2M products to be globally comparable. An international interlaboratory comparison on thickness measurements of graphene oxide flakes using atomic force microscopy has been completed in technical working area 41 of versailles project on advanced materials and standards. Twelve laboratories participated in the comparison project, led by NIM, China, to improve the equivalence of thickness measurement for two-dimensional flakes. The measurement methods, uncertainty evaluation and a comparison of the results and analysis are reported in this manuscript. The data and results of this project will be directly used to support the development of an ISO standard.
- 6 February 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (5) , 054006
Local geometric error corrections for a metrological scanning probe microscope
A local geometric error correction method is developed for a metrological scanning probe microscope. The method corrects geometric errors in stage displacements using the interferometric measurements of angular position and known geometric offsets. Local and global error correction methods are considered and general scaling dependences on the number of measured steps or points are derived and compared. For the local method, the total uncertainty scales the same or decreases with a sufficient number of measurement steps compared with the global method. Implementation of the local geometric error correction method is demonstrated on measurements of a three-dimensional height standard artefact. The applied error correction method reduces the contribution of geometric errors to the uncertainty budget by two orders of magnitude. The presented approach can be extended to any scanning technique where a measurement translation mechanism can be identified and accurately quantified by relating the measured values with a measurand.
- 6 February 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (5) , 054006
Local geometric error corrections for a metrological scanning probe microscope
A local geometric error correction method is developed for a metrological scanning probe microscope. The method corrects geometric errors in stage displacements using the interferometric measurements of angular position and known geometric offsets. Local and global error correction methods are considered and general scaling dependences on the number of measured steps or points are derived and compared. For the local method, the total uncertainty scales the same or decreases with a sufficient number of measurement steps compared with the global method. Implementation of the local geometric error correction method is demonstrated on measurements of a three-dimensional height standard artefact. The applied error correction method reduces the contribution of geometric errors to the uncertainty budget by two orders of magnitude. The presented approach can be extended to any scanning technique where a measurement translation mechanism can be identified and accurately quantified by relating the measured values with a measurand.
- 6 June 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (21) , 214307
Minimising the effect of nanoparticle deformation in intermittent contact amplitude modulation atomic force microscopy measurements
The results of systematic height measurements of polystyrene (PS) nanoparticles using intermittent contact amplitude modulation atomic force microscopy (IC-AM-AFM) are presented. The experimental findings demonstrate that PS nanoparticles deform during AFM imaging, as indicated by a reduction in the measured particle height. This deformation depends on the IC-AM-AFM imaging parameters, material composition, and dimensional properties of the nanoparticles. A model for nanoparticle deformation occurring during IC-AM-AFM imaging is developed as a function of the peak force which can be calculated for a particular set of experimental conditions. The undeformed nanoparticle height can be estimated from the model by extrapolation to zero peak force. A procedure is proposed to quantify and minimise nanoparticle deformation during IC-AM-AFM imaging, based on appropriate adjustments of the experimental control parameters.
- 6 June 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (21) , 214307
Minimising the effect of nanoparticle deformation in intermittent contact amplitude modulation atomic force microscopy measurements
The results of systematic height measurements of polystyrene (PS) nanoparticles using intermittent contact amplitude modulation atomic force microscopy (IC-AM-AFM) are presented. The experimental findings demonstrate that PS nanoparticles deform during AFM imaging, as indicated by a reduction in the measured particle height. This deformation depends on the IC-AM-AFM imaging parameters, material composition, and dimensional properties of the nanoparticles. A model for nanoparticle deformation occurring during IC-AM-AFM imaging is developed as a function of the peak force which can be calculated for a particular set of experimental conditions. The undeformed nanoparticle height can be estimated from the model by extrapolation to zero peak force. A procedure is proposed to quantify and minimise nanoparticle deformation during IC-AM-AFM imaging, based on appropriate adjustments of the experimental control parameters.
- 1 March 2015
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 223, 167-173
Mechanical and electrical characterization of quartz tuning fork force sensors
- 1 March 2015
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 223, 167-173
Mechanical and electrical characterization of quartz tuning fork force sensors
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 908-911
Development of a metrological scanning probe microscope incorporating a quartz tuning fork sensor and heterodyne laser interferometry
We present an overview of the design of the metrological scanning probe microscope (mSPM) currently under development at the National Measurement Institute Australia (NMIA) and report on preliminary results on the characterization of key components. The mSPM is being developed as part of the nanometrology program at NMIA and will provide dimensional measurements made at the nanometer scale that are traceable to the realization of the SI meter at NMIA. The instrument will provide an addressable measurement volume of 100 μm × 100 μm × 25 μm with a target uncertainty of 1 nm for the position measurement. It incorporates a quartz tuning fork (QTF) detector and a high-performance heterodyne laser interferometer system.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 908-911
Development of a metrological scanning probe microscope incorporating a quartz tuning fork sensor and heterodyne laser interferometry
We present an overview of the design of the metrological scanning probe microscope (mSPM) currently under development at the National Measurement Institute Australia (NMIA) and report on preliminary results on the characterization of key components. The mSPM is being developed as part of the nanometrology program at NMIA and will provide dimensional measurements made at the nanometer scale that are traceable to the realization of the SI meter at NMIA. The instrument will provide an addressable measurement volume of 100 μm × 100 μm × 25 μm with a target uncertainty of 1 nm for the position measurement. It incorporates a quartz tuning fork (QTF) detector and a high-performance heterodyne laser interferometer system.
- 13 May 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8036
A metrological scanning probe microscope based on a quartz tuning fork detector
We give an overview of the design of a metrological Scanning Probe Microscope (mSPM) currently under development at the National Measurement Institute Australia (NMIA) and report on preliminary results on the implementation of key components. The mSPM is being developed as part of the nanometrology program at NMIA and will provide the link in the traceability chain between dimensional measurements made at the nanometre scale and the realization of the SI metre at NMIA. The instrument is based on a quartz tuning fork (QTF) detector and will provide a measurement volume of 100 μm × 100 μm × 25 μm with a target uncertainty of 1 nm for the position measurement. Characterization results of the nanopositioning stage and the QTF detector are presented along with an outline of the method for tip mounting on the QTFs. Initial imaging results are also presented.
- 13 May 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8036
A metrological scanning probe microscope based on a quartz tuning fork detector
We give an overview of the design of a metrological Scanning Probe Microscope (mSPM) currently under development at the National Measurement Institute Australia (NMIA) and report on preliminary results on the implementation of key components. The mSPM is being developed as part of the nanometrology program at NMIA and will provide the link in the traceability chain between dimensional measurements made at the nanometre scale and the realization of the SI metre at NMIA. The instrument is based on a quartz tuning fork (QTF) detector and will provide a measurement volume of 100 μm × 100 μm × 25 μm with a target uncertainty of 1 nm for the position measurement. Characterization results of the nanopositioning stage and the QTF detector are presented along with an outline of the method for tip mounting on the QTFs. Initial imaging results are also presented.
- Open Access
- 1 December 2009
- Published by American Scientific Publishers in Journal of Bionanoscience
- Vol. 3 (2) , 73-79
Synthesis and Characterization of DNA-Based Micro- and Nanodumbbell Structures
- 1 December 2009
- Published by American Scientific Publishers in Journal of Bionanoscience
- Vol. 3 (2) , 73-79
Open AccessSynthesis and Characterization of DNA-Based Micro- and Nanodumbbell Structures
- 4 February 2008
- Published by AIP Publishing in Applied Physics Letters
- Vol. 92 (5) , 053901
Magnetophoresis of flexible DNA-based dumbbell structures
Controlled movement and manipulation of magnetic micro- and nanostructures using magnetic forces can give rise to important applications in biomedecine, diagnostics, and immunology. We report controlled magnetophoresis and stretching, in aqueous solution, of a DNA-based dumbbell structure containing magnetic and diamagnetic microspheres. The velocity and stretching of the dumbbell were experimentally measured and correlated with a theoretical model based on the forces acting on individual magnetic beads or the entire dumbbell structures. The results show that precise and predictable manipulation of dumbbell structures is achievable and can potentially be applied to immunomagnetic cell separators.
- 4 February 2008
- Published by AIP Publishing in Applied Physics Letters
- Vol. 92 (5) , 053901
Magnetophoresis of flexible DNA-based dumbbell structures
Controlled movement and manipulation of magnetic micro- and nanostructures using magnetic forces can give rise to important applications in biomedecine, diagnostics, and immunology. We report controlled magnetophoresis and stretching, in aqueous solution, of a DNA-based dumbbell structure containing magnetic and diamagnetic microspheres. The velocity and stretching of the dumbbell were experimentally measured and correlated with a theoretical model based on the forces acting on individual magnetic beads or the entire dumbbell structures. The results show that precise and predictable manipulation of dumbbell structures is achievable and can potentially be applied to immunomagnetic cell separators.
- 12 May 2005
- Published by American Physical Society (APS) in Physical Review B
- Vol. 71 (20) , 209901
Publisher's Note: Observation of Fano resonances in single-wall carbon nanotubes [Phys. Rev. B70, 195408 (2004)]
DOI:https://doi.org/10.1103/PhysRevB.71.209901
- 12 May 2005
- Published by American Physical Society (APS) in Physical Review B
- Vol. 71 (20) , 209901
Publisher's Note: Observation of Fano resonances in single-wall carbon nanotubes [Phys. Rev. B70, 195408 (2004)]
DOI:https://doi.org/10.1103/PhysRevB.71.209901