Dongli Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dongli Chen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Chunying Lin
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China
3 shared publicationsSilin Chen
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China
3 shared publicationsYuanhong Liang
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China
3 shared publicationsJiaojiao Tang
Department of Cardiology, Second Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China
2 shared publications- Lie Liu
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510000, Guangdong, China.
2 shared publications Qianhuan Zhang
Department of Echocardiography, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China
2 shared publications
Latest Publications
- 1 February 2019
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 45 (2) , 385-394
Assessment of Permanent Selective His Bundle Pacing in Left Ventricular Synchronization Using 3-D Speckle Tracking Echocardiography
- 1 February 2019
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 45 (2) , 385-394
Assessment of Permanent Selective His Bundle Pacing in Left Ventricular Synchronization Using 3-D Speckle Tracking Echocardiography
- 1 October 2014
- Vol. 34 (10) , 1551-4
[Right ventricular apical versus right ventricular outflow tract pacing: impact on left ventricular synchronization].
Objective To compare the impact of right ventricular apical (RVA) versus right ventricular outflow tract (RVOT) pacing on left ventricular systolic synchronization. Sixty patients were prospectively recruited and randomized into RVA group (n=30) with the right ventricle leads placed in the RVA and RVOT group (n=30) with right ventricle leads placed in the septum of the RVOT. Speckle tracking imaging was performed with 100% ventricle pacing to measure the differences in the time to maximum left ventricle (LV) radial strain. In RVA group, the difference in the time to 6-segment maximum LV radial strain after pacing was 105.27 ± 19.74 ms, significantly greater than that in RVOT group (41.65 ± 12.17 ms, P<0.001). The standard difference of time to 6-segment maximum LV radial strain was also significantly greater in RVA group than in RVOT group (42.71 ± 17.63 vs 17.63 ± 5.62 ms, P<0.001). Left ventricle systolic synchronizaition after RVOT pacing is superior to RVA pacing.
- 1 October 2014
- Vol. 34 (10) , 1551-4
[Right ventricular apical versus right ventricular outflow tract pacing: impact on left ventricular synchronization].
Objective To compare the impact of right ventricular apical (RVA) versus right ventricular outflow tract (RVOT) pacing on left ventricular systolic synchronization. Sixty patients were prospectively recruited and randomized into RVA group (n=30) with the right ventricle leads placed in the RVA and RVOT group (n=30) with right ventricle leads placed in the septum of the RVOT. Speckle tracking imaging was performed with 100% ventricle pacing to measure the differences in the time to maximum left ventricle (LV) radial strain. In RVA group, the difference in the time to 6-segment maximum LV radial strain after pacing was 105.27 ± 19.74 ms, significantly greater than that in RVOT group (41.65 ± 12.17 ms, P<0.001). The standard difference of time to 6-segment maximum LV radial strain was also significantly greater in RVA group than in RVOT group (42.71 ± 17.63 vs 17.63 ± 5.62 ms, P<0.001). Left ventricle systolic synchronizaition after RVOT pacing is superior to RVA pacing.
- 1 August 2013
- Vol. 33 (8) , 1229-31
[Evaluation of implanted cardioverter-defibrillators for primary prevention of sudden cardiac death].
To evaluate the clinical effect of implanted cardioverter-defibrillators (ICD) for primary prevention of sudden cardiac death. According to ACC/AHA Guideline of ICD implantation (2005), 35 patients successfully received ICD/CRT-D implantation for primary prevention of sudden cardiac death in our hospital from January 2006 to December 2009. All the patients were followed up for a mean of 2 years. During the follow up, 11 (31.43%) patients experienced ventricular arrhythmic episodes, for which 16 defibrillation therapies and 75 anti-tachycardia pacing (ATP) therapies were delivered without mistaken shock or death. The incidence rate of NVM was 100%, that of PVT was 66.67%, Brugada syndrome 50%, HCM 25% and DCM 16.67%. Of these episodes, the incidence of VF episodes among PVC patients was 87.5% (14 beats), ventricular tachycardia PVC was 82.28% (65 times), 5 beats in NVM patients, 4 beats in HCM and Brugada syndrome patients, and 1 beat in DCM patients. No ICD implantation-related complication was detected, and no ventricular tachycardia induced syncope occurred in these cases. All patients showed improved quality of life after the implantation. ICD implantation can prevent malignant ventricular arrhythmia episodes, especially for PVT, NVM and Brugada syndrome in high risk SCD patients, demonstrating the value of implantation of ICD as a primary prevention in high-risk SCD patients.
- 1 August 2013
- Vol. 33 (8) , 1229-31
[Evaluation of implanted cardioverter-defibrillators for primary prevention of sudden cardiac death].
To evaluate the clinical effect of implanted cardioverter-defibrillators (ICD) for primary prevention of sudden cardiac death. According to ACC/AHA Guideline of ICD implantation (2005), 35 patients successfully received ICD/CRT-D implantation for primary prevention of sudden cardiac death in our hospital from January 2006 to December 2009. All the patients were followed up for a mean of 2 years. During the follow up, 11 (31.43%) patients experienced ventricular arrhythmic episodes, for which 16 defibrillation therapies and 75 anti-tachycardia pacing (ATP) therapies were delivered without mistaken shock or death. The incidence rate of NVM was 100%, that of PVT was 66.67%, Brugada syndrome 50%, HCM 25% and DCM 16.67%. Of these episodes, the incidence of VF episodes among PVC patients was 87.5% (14 beats), ventricular tachycardia PVC was 82.28% (65 times), 5 beats in NVM patients, 4 beats in HCM and Brugada syndrome patients, and 1 beat in DCM patients. No ICD implantation-related complication was detected, and no ventricular tachycardia induced syncope occurred in these cases. All patients showed improved quality of life after the implantation. ICD implantation can prevent malignant ventricular arrhythmia episodes, especially for PVT, NVM and Brugada syndrome in high risk SCD patients, demonstrating the value of implantation of ICD as a primary prevention in high-risk SCD patients.