Lie Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lie Liu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Chunying Lin
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510000, Guangdong, China
3 shared publicationsSilin Chen
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510000, Guangdong, China
3 shared publicationsYuanhong Liang
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510000, Guangdong, China
3 shared publications- Dongli Chen
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China
2 shared publications Qianhuan Zhang
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510000, Guangdong, China
2 shared publicationsChun-Ying Lin
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medicine Science, Guangzhou, 510100, China
1 shared publication
Latest Publications
- Open Access
- 21 January 2016
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (5) , 721-728
A randomized comparison of fluoroscopic techniques for implanting pacemaker lead on the right ventricular outflow tract septum
Right ventricular outflow tract (RVOT) septal pacing is commonly performed under the standard fluoroscopic positions during procedure. The aim of the prospective, randomized study was to evaluate the accuracy of the combination of standard fluoroscopic and left lateral (LL) fluoroscopic views for determination of RVOT septal position compared with standard fluoroscopic views alone. We prospectively enrolled patients who had indications for implantation of a permanent pacemaker. Patients were randomly assigned into two groups based on intraoperative fluoroscopic views as follows: LL group (three standard fluoroscopic views + LL fluoroscopic view) or standard group (three standard fluoroscopic views). Transthoracic echocardiography (TTE) determination of pacing sites was applied in all patients 3 days after pacemaker implantation. The implantation success rate of RVOT septal pacing was compared between groups. A total of 143 patients (59 males, mean age 57.6 ± 16.3 years) with symptomatic bradyarrhythmia were studied, of whom, 72 patients were randomized to LL group and 71 to standard group. TTE determination of pacing sites was compared with two groups. In the LL group, 60 patients (83 %) were achieved in RVOT septal position. In the standard group, however, the position of RVOT septum was only observed in 48 patients (68 %). The success rate of RVOT septal position in LL group was significantly higher than standard group (p = 0.029). Comparing to traditional views, combining LL view in the procedure will approve the accuracy of RVOT septal pacing site.
- 21 January 2016
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (5) , 721-728
Open AccessA randomized comparison of fluoroscopic techniques for implanting pacemaker lead on the right ventricular outflow tract septum
Right ventricular outflow tract (RVOT) septal pacing is commonly performed under the standard fluoroscopic positions during procedure. The aim of the prospective, randomized study was to evaluate the accuracy of the combination of standard fluoroscopic and left lateral (LL) fluoroscopic views for determination of RVOT septal position compared with standard fluoroscopic views alone. We prospectively enrolled patients who had indications for implantation of a permanent pacemaker. Patients were randomly assigned into two groups based on intraoperative fluoroscopic views as follows: LL group (three standard fluoroscopic views + LL fluoroscopic view) or standard group (three standard fluoroscopic views). Transthoracic echocardiography (TTE) determination of pacing sites was applied in all patients 3 days after pacemaker implantation. The implantation success rate of RVOT septal pacing was compared between groups. A total of 143 patients (59 males, mean age 57.6 ± 16.3 years) with symptomatic bradyarrhythmia were studied, of whom, 72 patients were randomized to LL group and 71 to standard group. TTE determination of pacing sites was compared with two groups. In the LL group, 60 patients (83 %) were achieved in RVOT septal position. In the standard group, however, the position of RVOT septum was only observed in 48 patients (68 %). The success rate of RVOT septal position in LL group was significantly higher than standard group (p = 0.029). Comparing to traditional views, combining LL view in the procedure will approve the accuracy of RVOT septal pacing site.
- 16 December 2015
- Published by Springer Nature in Current Medical Science
- Vol. 35 (6) , 858-861
Right ventricular outflow tract septal pacing versus apical pacing: A prospective, randomized, single-blind 5-years follow-up study of ventricular lead performance and safety
Lead placement for ventricular pacing variably impacts the physiological benefit of the patient. This study evaluated the ventricular lead performance and safety of right ventricular outflow tract septal pacing in patients with bradyarrhythmia in South China over 60-month follow-up. Totally, 192 patients (108 males, and 84 females, 63±21 years old) with bradyarrhythmia were randomly divided into two groups. The right ventricular outflow tract septum (RVOTs) group had lead placement near the septum (n=97), while the right ventricular apex (RVA) group had a traditional apical placement (n=95). RV septal lead positioning was achieved with a specialized stylet and confirmed using fluoroscopic projection. All patients were followed up for 60 months. Follow-up assessment included stimulation threshold, R-wave sensing, lead impedance and lead complications. The time of electrode implantation in both the ROVTs and RVA groups were significantly different (4.29±0.61 vs. 2.16±0.22 min; P=0.009). No differences were identified in threshold, impedance or R-wave sensing between the two groups at 1st, 12th, 36th and 60th month during the follow-up period. No occurrence of electrode displacement, increased pacing threshold or inadequate sensing was found. The long-term active fixation ventricular electrode performance in RVOTs group was similar to that in RVA group. RVOTs pacing near the septum using active fixation electrodes may provide stability during long-term follow-up period.
- 16 December 2015
- Published by Springer Nature in Current Medical Science
- Vol. 35 (6) , 858-861
Right ventricular outflow tract septal pacing versus apical pacing: A prospective, randomized, single-blind 5-years follow-up study of ventricular lead performance and safety
Lead placement for ventricular pacing variably impacts the physiological benefit of the patient. This study evaluated the ventricular lead performance and safety of right ventricular outflow tract septal pacing in patients with bradyarrhythmia in South China over 60-month follow-up. Totally, 192 patients (108 males, and 84 females, 63±21 years old) with bradyarrhythmia were randomly divided into two groups. The right ventricular outflow tract septum (RVOTs) group had lead placement near the septum (n=97), while the right ventricular apex (RVA) group had a traditional apical placement (n=95). RV septal lead positioning was achieved with a specialized stylet and confirmed using fluoroscopic projection. All patients were followed up for 60 months. Follow-up assessment included stimulation threshold, R-wave sensing, lead impedance and lead complications. The time of electrode implantation in both the ROVTs and RVA groups were significantly different (4.29±0.61 vs. 2.16±0.22 min; P=0.009). No differences were identified in threshold, impedance or R-wave sensing between the two groups at 1st, 12th, 36th and 60th month during the follow-up period. No occurrence of electrode displacement, increased pacing threshold or inadequate sensing was found. The long-term active fixation ventricular electrode performance in RVOTs group was similar to that in RVA group. RVOTs pacing near the septum using active fixation electrodes may provide stability during long-term follow-up period.
- 1 October 2014
- Vol. 34 (10) , 1551-4
[Right ventricular apical versus right ventricular outflow tract pacing: impact on left ventricular synchronization].
Objective To compare the impact of right ventricular apical (RVA) versus right ventricular outflow tract (RVOT) pacing on left ventricular systolic synchronization. Sixty patients were prospectively recruited and randomized into RVA group (n=30) with the right ventricle leads placed in the RVA and RVOT group (n=30) with right ventricle leads placed in the septum of the RVOT. Speckle tracking imaging was performed with 100% ventricle pacing to measure the differences in the time to maximum left ventricle (LV) radial strain. In RVA group, the difference in the time to 6-segment maximum LV radial strain after pacing was 105.27 ± 19.74 ms, significantly greater than that in RVOT group (41.65 ± 12.17 ms, P<0.001). The standard difference of time to 6-segment maximum LV radial strain was also significantly greater in RVA group than in RVOT group (42.71 ± 17.63 vs 17.63 ± 5.62 ms, P<0.001). Left ventricle systolic synchronizaition after RVOT pacing is superior to RVA pacing.
- 1 October 2014
- Vol. 34 (10) , 1551-4
[Right ventricular apical versus right ventricular outflow tract pacing: impact on left ventricular synchronization].
Objective To compare the impact of right ventricular apical (RVA) versus right ventricular outflow tract (RVOT) pacing on left ventricular systolic synchronization. Sixty patients were prospectively recruited and randomized into RVA group (n=30) with the right ventricle leads placed in the RVA and RVOT group (n=30) with right ventricle leads placed in the septum of the RVOT. Speckle tracking imaging was performed with 100% ventricle pacing to measure the differences in the time to maximum left ventricle (LV) radial strain. In RVA group, the difference in the time to 6-segment maximum LV radial strain after pacing was 105.27 ± 19.74 ms, significantly greater than that in RVOT group (41.65 ± 12.17 ms, P<0.001). The standard difference of time to 6-segment maximum LV radial strain was also significantly greater in RVA group than in RVOT group (42.71 ± 17.63 vs 17.63 ± 5.62 ms, P<0.001). Left ventricle systolic synchronizaition after RVOT pacing is superior to RVA pacing.
- 1 August 2013
- Vol. 33 (8) , 1229-31
[Evaluation of implanted cardioverter-defibrillators for primary prevention of sudden cardiac death].
To evaluate the clinical effect of implanted cardioverter-defibrillators (ICD) for primary prevention of sudden cardiac death. According to ACC/AHA Guideline of ICD implantation (2005), 35 patients successfully received ICD/CRT-D implantation for primary prevention of sudden cardiac death in our hospital from January 2006 to December 2009. All the patients were followed up for a mean of 2 years. During the follow up, 11 (31.43%) patients experienced ventricular arrhythmic episodes, for which 16 defibrillation therapies and 75 anti-tachycardia pacing (ATP) therapies were delivered without mistaken shock or death. The incidence rate of NVM was 100%, that of PVT was 66.67%, Brugada syndrome 50%, HCM 25% and DCM 16.67%. Of these episodes, the incidence of VF episodes among PVC patients was 87.5% (14 beats), ventricular tachycardia PVC was 82.28% (65 times), 5 beats in NVM patients, 4 beats in HCM and Brugada syndrome patients, and 1 beat in DCM patients. No ICD implantation-related complication was detected, and no ventricular tachycardia induced syncope occurred in these cases. All patients showed improved quality of life after the implantation. ICD implantation can prevent malignant ventricular arrhythmia episodes, especially for PVT, NVM and Brugada syndrome in high risk SCD patients, demonstrating the value of implantation of ICD as a primary prevention in high-risk SCD patients.
- 1 August 2013
- Vol. 33 (8) , 1229-31
[Evaluation of implanted cardioverter-defibrillators for primary prevention of sudden cardiac death].
To evaluate the clinical effect of implanted cardioverter-defibrillators (ICD) for primary prevention of sudden cardiac death. According to ACC/AHA Guideline of ICD implantation (2005), 35 patients successfully received ICD/CRT-D implantation for primary prevention of sudden cardiac death in our hospital from January 2006 to December 2009. All the patients were followed up for a mean of 2 years. During the follow up, 11 (31.43%) patients experienced ventricular arrhythmic episodes, for which 16 defibrillation therapies and 75 anti-tachycardia pacing (ATP) therapies were delivered without mistaken shock or death. The incidence rate of NVM was 100%, that of PVT was 66.67%, Brugada syndrome 50%, HCM 25% and DCM 16.67%. Of these episodes, the incidence of VF episodes among PVC patients was 87.5% (14 beats), ventricular tachycardia PVC was 82.28% (65 times), 5 beats in NVM patients, 4 beats in HCM and Brugada syndrome patients, and 1 beat in DCM patients. No ICD implantation-related complication was detected, and no ventricular tachycardia induced syncope occurred in these cases. All patients showed improved quality of life after the implantation. ICD implantation can prevent malignant ventricular arrhythmia episodes, especially for PVT, NVM and Brugada syndrome in high risk SCD patients, demonstrating the value of implantation of ICD as a primary prevention in high-risk SCD patients.