Neda Rastegarfard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Neda Rastegarfard has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Oranous Moradi
Dental Faculty Hamadan University of Medical Sciences Hamadan IR Iran
3 shared publicationsErfan Abbasi
Department of Periodontology Dental Faculty Hamadan University of Medical Sciences Hamadan IR Iran
2 shared publications- Fariborz Vafaee
Department of Prosthodontics, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
2 shared publications Janet Moradi Haghgoo
Department of Periodontics, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
2 shared publicationsMassoumeh Khoshhal
Department of Periodontology Dental Faculty Hamadan University of Medical Sciences Hamadan IR Iran
2 shared publicationsShahram Sharifi
Department of Periodontology Dental Faculty Hamadan University of Medical Sciences Hamadan IR Iran
2 shared publications
Latest Publications
- Open Access
- 21 June 2017
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 11 (2) , 73-77
Comparison of the effect of three autogenous bone harvesting methods on cell viability in rabbits
Background. This study was designed to compare the viability of autogenous bone grafts, harvested using different methods, in order to determine the best harvesting technique with respect to more viable cells. Methods. In this animal experimental study, three harvesting methods, including manual instrument (chisel), rotary device and piezosurgery, were used for harvesting bone grafts from the lateral body of the mandible on the left and right sides of 10 rabbits. In each group, 20 bone samples were collected and their viability was assessed using MTS kit. Statistical analyses, including ANOVA and post hoc Tukey tests, were used for evaluating significant differences between the groups. Results. One-way ANOVA showed significant differences between all the groups (P=0.000). Data analysis using post hoc Tukey tests indicated that manual instrument and piezosurgery had no significant differences with regard to cell viability (P=0.749) and the cell viability in both groups was higher than that with the use of a rotary instrument (P=0.000). Conclusion. Autogenous bone grafts harvested with a manual instrument and piezosurgery had more viable cells in comparison to the bone chips harvested with a rotary device.
- 21 June 2017
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 11 (2) , 73-77
Open AccessComparison of the effect of three autogenous bone harvesting methods on cell viability in rabbits
Background. This study was designed to compare the viability of autogenous bone grafts, harvested using different methods, in order to determine the best harvesting technique with respect to more viable cells. Methods. In this animal experimental study, three harvesting methods, including manual instrument (chisel), rotary device and piezosurgery, were used for harvesting bone grafts from the lateral body of the mandible on the left and right sides of 10 rabbits. In each group, 20 bone samples were collected and their viability was assessed using MTS kit. Statistical analyses, including ANOVA and post hoc Tukey tests, were used for evaluating significant differences between the groups. Results. One-way ANOVA showed significant differences between all the groups (P=0.000). Data analysis using post hoc Tukey tests indicated that manual instrument and piezosurgery had no significant differences with regard to cell viability (P=0.749) and the cell viability in both groups was higher than that with the use of a rotary instrument (P=0.000). Conclusion. Autogenous bone grafts harvested with a manual instrument and piezosurgery had more viable cells in comparison to the bone chips harvested with a rotary device.
- Open Access
- 17 September 2016
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 8 (4)
Comparison of Whole Salivary Lactate Dehydrogenase Level in Patients With and Without Periodontal Disease
Background: Tracking various biomarkers in serum, gingival crevicular fluid (GCF), and saliva has been introduced as a diagnostic tool for periodontal disease detection. Objectives: The aim of this study was to compare salivary lactate dehydrogenase (LDH) levels in subjects with periodontal disease and levels in subjects without periodontal disease. Materials and Methods: In this case-control study, 170 patients at Hamadan faculty of Dentistry, including patients with periodontal disease and patients with normal periodontium, were selected and divided into test and control groups. Unstimulated saliva was collected in the same situation from the test and control groups. Each saliva sample was analyzed to measure salivary LDH level on the day of collection, by using commercially available kits according to the manufacturers’ instructions. A statistical T-test was employed to evaluate significant differences among groups. Results: The mean LDH levels in the test and control groups were 1071.67 ± 731.004 and 550.91 ± 217.215, respectively. As the level of statistical significance was set at P < 0.05, data analysis showed a significant difference between the LDH enzymatic level in the test and control groups (P = 0.000). Comparison of the LDH enzymatic level in subjects with different genders in the test and control groups showed no significant differences (P = 0.340). Conclusions: Salivary LDH levels can be used as marker of periodontal disease for screening periodontitis in large populations. Keywords: Periodontal Disease Biomarkers; Lactate Dehydrogenase; Diagnostic Indicator; Periodontal Diagnosis; Periodontal Diseases; Periodontitis; Saliva
- 17 September 2016
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 8 (4)
Open AccessComparison of Whole Salivary Lactate Dehydrogenase Level in Patients With and Without Periodontal Disease
Background: Tracking various biomarkers in serum, gingival crevicular fluid (GCF), and saliva has been introduced as a diagnostic tool for periodontal disease detection. Objectives: The aim of this study was to compare salivary lactate dehydrogenase (LDH) levels in subjects with periodontal disease and levels in subjects without periodontal disease. Materials and Methods: In this case-control study, 170 patients at Hamadan faculty of Dentistry, including patients with periodontal disease and patients with normal periodontium, were selected and divided into test and control groups. Unstimulated saliva was collected in the same situation from the test and control groups. Each saliva sample was analyzed to measure salivary LDH level on the day of collection, by using commercially available kits according to the manufacturers’ instructions. A statistical T-test was employed to evaluate significant differences among groups. Results: The mean LDH levels in the test and control groups were 1071.67 ± 731.004 and 550.91 ± 217.215, respectively. As the level of statistical significance was set at P < 0.05, data analysis showed a significant difference between the LDH enzymatic level in the test and control groups (P = 0.000). Comparison of the LDH enzymatic level in subjects with different genders in the test and control groups showed no significant differences (P = 0.340). Conclusions: Salivary LDH levels can be used as marker of periodontal disease for screening periodontitis in large populations. Keywords: Periodontal Disease Biomarkers; Lactate Dehydrogenase; Diagnostic Indicator; Periodontal Diagnosis; Periodontal Diseases; Periodontitis; Saliva
- Open Access
- 25 June 2016
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. In Press (In Press)
Evaluation of Clinical and Radiographic Signs of Implants in Patients With Implant Retained Mandibular Overdentures
Background: The minimum standard treatment plan for the reconstruction of an edentulous mandible, according to York, is an overdenture supported by two implants. Objectives: The aims of this study were to evaluate and compare the clinical outcomes and peri-implant marginal bone loss around implants in patients treated with mandibular overdentures supported by 1, 2, 3, 4, and 5 implants. Materials and Methods: A total of 25 patients with a mean age of 62.7 years old, who were treated with implant supported mandibular overdentures at Hamedan’s faculty of dentistry, were enrolled in this cross-sectional study. Among these patients, 6 had overdentures supported by one implant, 9 had overdentures supported by two implants, 2 had overdentures supported by three implants, 5 had overdentures supported by 4 implants, and 3 had overdentures supported by 5 implants. The clinical and radiographic parameters around the implants were assessed, including: probing depth, width of keratinized gingiva, bleeding on probing, peri-implant inflammation, calculus formation, implant mobility, adverse events, and radiographic signs of peri-implant bone loss (distance between the implant shoulder and the level of the mesial and distal proximal bone). The ANOVA and the Fisher’s Exact test were used to evaluate the significant differences among the groups. Results: None of the implants had loosened and no adverse events were seen around the implants. Additionally, the clinical variables did not show significant correlation with the number of implants. Overall, the bone resorption showed an inverse and significant relationship with the number of implants (P = 0.001). Conclusions: With mandibular overdentures supported by 1, 2, 3, 4, and 5 implants, favorable clinical outcomes can be achieved. However, when increasing the number of implants, marginal bone loss decreases. For example, the patients with five implants showed less marginal bone loss than those with a lesser number of implants. Keywords: Bleeding on Probing; Calculus; Keratinized Gingiva; Mandibular Overdenture; Probing Depth
- 25 June 2016
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. In Press (In Press)
Open AccessEvaluation of Clinical and Radiographic Signs of Implants in Patients With Implant Retained Mandibular Overdentures
Background: The minimum standard treatment plan for the reconstruction of an edentulous mandible, according to York, is an overdenture supported by two implants. Objectives: The aims of this study were to evaluate and compare the clinical outcomes and peri-implant marginal bone loss around implants in patients treated with mandibular overdentures supported by 1, 2, 3, 4, and 5 implants. Materials and Methods: A total of 25 patients with a mean age of 62.7 years old, who were treated with implant supported mandibular overdentures at Hamedan’s faculty of dentistry, were enrolled in this cross-sectional study. Among these patients, 6 had overdentures supported by one implant, 9 had overdentures supported by two implants, 2 had overdentures supported by three implants, 5 had overdentures supported by 4 implants, and 3 had overdentures supported by 5 implants. The clinical and radiographic parameters around the implants were assessed, including: probing depth, width of keratinized gingiva, bleeding on probing, peri-implant inflammation, calculus formation, implant mobility, adverse events, and radiographic signs of peri-implant bone loss (distance between the implant shoulder and the level of the mesial and distal proximal bone). The ANOVA and the Fisher’s Exact test were used to evaluate the significant differences among the groups. Results: None of the implants had loosened and no adverse events were seen around the implants. Additionally, the clinical variables did not show significant correlation with the number of implants. Overall, the bone resorption showed an inverse and significant relationship with the number of implants (P = 0.001). Conclusions: With mandibular overdentures supported by 1, 2, 3, 4, and 5 implants, favorable clinical outcomes can be achieved. However, when increasing the number of implants, marginal bone loss decreases. For example, the patients with five implants showed less marginal bone loss than those with a lesser number of implants. Keywords: Bleeding on Probing; Calculus; Keratinized Gingiva; Mandibular Overdenture; Probing Depth
- Open Access
- 25 June 2016
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 9 (2) , e29360
Evaluation of Clinical and Radiographic Signs of Implants in Patients With Implant Retained Mandibular Overdentures
Background: The minimum standard treatment plan for the reconstruction of an edentulous mandible, according to York, is an overdenture supported by two implants. Objectives: The aims of this study were to evaluate and compare the clinical outcomes and peri-implant marginal bone loss around implants in patients treated with mandibular overdentures supported by 1, 2, 3, 4, and 5 implants. Materials and Methods: A total of 25 patients with a mean age of 62.7 years old, who were treated with implant supported mandibular overdentures at Hamedan’s faculty of dentistry, were enrolled in this cross-sectional study. Among these patients, 6 had overdentures supported by one implant, 9 had overdentures supported by two implants, 2 had overdentures supported by three implants, 5 had overdentures supported by 4 implants, and 3 had overdentures supported by 5 implants. The clinical and radiographic parameters around the implants were assessed, including: probing depth, width of keratinized gingiva, bleeding on probing, peri-implant inflammation, calculus formation, implant mobility, adverse events, and radiographic signs of peri-implant bone loss (distance between the implant shoulder and the level of the mesial and distal proximal bone). The ANOVA and the Fisher’s Exact test were used to evaluate the significant differences among the groups. Results: None of the implants had loosened and no adverse events were seen around the implants. Additionally, the clinical variables did not show significant correlation with the number of implants. Overall, the bone resorption showed an inverse and significant relationship with the number of implants (P = 0.001). Conclusions: With mandibular overdentures supported by 1, 2, 3, 4, and 5 implants, favorable clinical outcomes can be achieved. However, when increasing the number of implants, marginal bone loss decreases. For example, the patients with five implants showed less marginal bone loss than those with a lesser number of implants. Keywords: Bleeding on Probing; Calculus; Keratinized Gingiva; Mandibular Overdenture; Probing Depth
- 25 June 2016
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 9 (2) , e29360
Open AccessEvaluation of Clinical and Radiographic Signs of Implants in Patients With Implant Retained Mandibular Overdentures
Background: The minimum standard treatment plan for the reconstruction of an edentulous mandible, according to York, is an overdenture supported by two implants. Objectives: The aims of this study were to evaluate and compare the clinical outcomes and peri-implant marginal bone loss around implants in patients treated with mandibular overdentures supported by 1, 2, 3, 4, and 5 implants. Materials and Methods: A total of 25 patients with a mean age of 62.7 years old, who were treated with implant supported mandibular overdentures at Hamedan’s faculty of dentistry, were enrolled in this cross-sectional study. Among these patients, 6 had overdentures supported by one implant, 9 had overdentures supported by two implants, 2 had overdentures supported by three implants, 5 had overdentures supported by 4 implants, and 3 had overdentures supported by 5 implants. The clinical and radiographic parameters around the implants were assessed, including: probing depth, width of keratinized gingiva, bleeding on probing, peri-implant inflammation, calculus formation, implant mobility, adverse events, and radiographic signs of peri-implant bone loss (distance between the implant shoulder and the level of the mesial and distal proximal bone). The ANOVA and the Fisher’s Exact test were used to evaluate the significant differences among the groups. Results: None of the implants had loosened and no adverse events were seen around the implants. Additionally, the clinical variables did not show significant correlation with the number of implants. Overall, the bone resorption showed an inverse and significant relationship with the number of implants (P = 0.001). Conclusions: With mandibular overdentures supported by 1, 2, 3, 4, and 5 implants, favorable clinical outcomes can be achieved. However, when increasing the number of implants, marginal bone loss decreases. For example, the patients with five implants showed less marginal bone loss than those with a lesser number of implants. Keywords: Bleeding on Probing; Calculus; Keratinized Gingiva; Mandibular Overdenture; Probing Depth
- Open Access
- 20 January 2016
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 8 (4)
Evaluation of Satisfaction Level in Patients With Mandibular Implant Supported Overdentures
Background: Implant-supported overdentures could have many benefits for patients, especially in the lower jaws. As a matter of fact, the most common reason for prescribing mandibular overdenture is dissatisfaction of patients with mandibular dentures usually because of a lack of retention, stability and function and speech difficulties. On the other hand, patients' expectations of overdenture treatments are their main disadvantage. Objectives: The aim of this study was to evaluate the satisfaction of patients who had received mandibular implant supported overdenture treatment with different number of implants. Patients and Methods: This study was a descriptive cross-sectional study. Twenty-five patients with a mean age of 62.7 years who had received mandibular implant supported overdenture treatment at the dental school of Hamadan University of Medical Sciences were enrolled. Among these patients, six had overdentures supported by one implant, nine had overdentures supported by two implants, two had overdentures supported by three implants, five had overdentures supported by four implants and three had overdentures supported by five implants. The visual analogue scale (VAS) questionnaire was used to evaluate the general satisfaction, comfort, esthetic, fitness, satisfaction of chewing and social communication, and the data was analyzed by the analysis of variance (ANOVA) test. Results: All patients in all five groups were satisfied with their overdentures; however there was no significant relationship between the number of implants and fitness (P = 0.446), esthetic (P = 0.843), comfort (P = 0.805), satisfaction of chewing (P = 0.133), social communication (P = 0.322) and general satisfaction (P = 0.493). Conclusions: There was no difference in satisfaction level of patients who had received mandibular overdentures with different number of implants. Keywords: Implant; Mandible; Overdenture; Satisfaction
- 20 January 2016
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 8 (4)
Open AccessEvaluation of Satisfaction Level in Patients With Mandibular Implant Supported Overdentures
Background: Implant-supported overdentures could have many benefits for patients, especially in the lower jaws. As a matter of fact, the most common reason for prescribing mandibular overdenture is dissatisfaction of patients with mandibular dentures usually because of a lack of retention, stability and function and speech difficulties. On the other hand, patients' expectations of overdenture treatments are their main disadvantage. Objectives: The aim of this study was to evaluate the satisfaction of patients who had received mandibular implant supported overdenture treatment with different number of implants. Patients and Methods: This study was a descriptive cross-sectional study. Twenty-five patients with a mean age of 62.7 years who had received mandibular implant supported overdenture treatment at the dental school of Hamadan University of Medical Sciences were enrolled. Among these patients, six had overdentures supported by one implant, nine had overdentures supported by two implants, two had overdentures supported by three implants, five had overdentures supported by four implants and three had overdentures supported by five implants. The visual analogue scale (VAS) questionnaire was used to evaluate the general satisfaction, comfort, esthetic, fitness, satisfaction of chewing and social communication, and the data was analyzed by the analysis of variance (ANOVA) test. Results: All patients in all five groups were satisfied with their overdentures; however there was no significant relationship between the number of implants and fitness (P = 0.446), esthetic (P = 0.843), comfort (P = 0.805), satisfaction of chewing (P = 0.133), social communication (P = 0.322) and general satisfaction (P = 0.493). Conclusions: There was no difference in satisfaction level of patients who had received mandibular overdentures with different number of implants. Keywords: Implant; Mandible; Overdenture; Satisfaction
- Open Access
- 1 September 2012
- Vol. 6 (3) , 89-93
Comparison of the Effect of Three Cements on Prevention of Enamel Demineralization Adjacent to Orthodontic Bands
This in vitro study was designed to compare enamel demineralization depths adjacent to bands cemented with zinc polycarboxylate, glass ionomer (GI) and resin-modified glass ionomer (RMGI), in order to achieve minimal enamel demineralization during orthodontic treatment. Sixty fully developed extracted third molars were randomly divided into three testgroups each containing 20 samples, used to cement orthodontic bands with zinc polycarboxylate, GI and RMGI. All samples were demineralized using White method using hydroxyapatite, latic acid and Carbapol for in vitro caries simulation, and then, immersed in 10% solution of methylene blue. The mean depth of dye penetration was assessed up to 0.1 millimeter, reflect-ing the depth of enamel demineralization. One way ANOVA and LSD statistical tests were employed to evaluate significant differences among groups. The highest dye penetration depth was seen in zinc polycarboxylate group, followed by GI, and RMGI groups, respectively, with significant differences among each two groups (P < 0.05). The use of RMGI cement seems to present significantly better prevention of enamel demineralization adja-cent to orthodontics bands.
- 1 September 2012
- Vol. 6 (3) , 89-93
Open AccessComparison of the Effect of Three Cements on Prevention of Enamel Demineralization Adjacent to Orthodontic Bands
This in vitro study was designed to compare enamel demineralization depths adjacent to bands cemented with zinc polycarboxylate, glass ionomer (GI) and resin-modified glass ionomer (RMGI), in order to achieve minimal enamel demineralization during orthodontic treatment. Sixty fully developed extracted third molars were randomly divided into three testgroups each containing 20 samples, used to cement orthodontic bands with zinc polycarboxylate, GI and RMGI. All samples were demineralized using White method using hydroxyapatite, latic acid and Carbapol for in vitro caries simulation, and then, immersed in 10% solution of methylene blue. The mean depth of dye penetration was assessed up to 0.1 millimeter, reflect-ing the depth of enamel demineralization. One way ANOVA and LSD statistical tests were employed to evaluate significant differences among groups. The highest dye penetration depth was seen in zinc polycarboxylate group, followed by GI, and RMGI groups, respectively, with significant differences among each two groups (P < 0.05). The use of RMGI cement seems to present significantly better prevention of enamel demineralization adja-cent to orthodontics bands.