Christian Kargel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christian Kargel has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Eder
Division of Medical Information Technology, Carinthia Tech Institute, University of Applied Sciences, Primoschgasse 10, 9020 Klagenfurt, Austria. Phone: +43-463-90500-3216, Fax: +43-463-90500-83216
1 shared publication B. Trummer
Department of Biomedical Engineering, University of California, Davis
1 shared publicationG. Hobenreich
Department of Biomedical Engineering, University of California, Davis, USA
1 shared publicationMartin Kafer
Division of Medical Information Technology, Carinthia Tech Institute, University of Applied Sciences, Primoschgasse 10, 9020 Klagenfurt, Austria. Phone: +43-463-90500-3216, Fax: +43-463-90500-83216
1 shared publication- Michael Blank
Division of Medical Information Technology, Carinthia Tech Institute, University of Applied Sciences, Primoschgasse 10, 9020 Klagenfurt, Austria. Phone: +43-463-90500-3216, Fax: +43-463-90500-83216
1 shared publication - Michael F. Insana
Univ. of Kansas Medical Ctr. (United States)
1 shared publication
Latest Publications
- 1 April 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 800-805
Displacement Estimators for Real-Time Ultrasonic Strain and Blood Flow Imaging with Improved Spatial Resolution
Ultrasonic strain and blood flow imaging have great potential to improve early tumor detection. Both methods share the same task of estimating echo signal displacements. To be able to resolve tissue stiffness and vascularity of tumors while still small in size, spatial resolution must be improved. In clinical practice ultrasonic real-time imaging is vital. In this paper we evaluate the performance of several displacement estimators with real-time capability and compare these with results from standard estimators when using echo signals that are typically available with a commercial ultrasound scanner set to yield the highest spatial resolution. Results are from simulations and tissue mimicking phantom experiments using a Voluson 730 scanner (GE Medical Systems Kretztechnik) equipped with a digital research interface and enabling the export of beam-formed radiofrequency (RF) echo data
- 1 April 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 800-805
Displacement Estimators for Real-Time Ultrasonic Strain and Blood Flow Imaging with Improved Spatial Resolution
Ultrasonic strain and blood flow imaging have great potential to improve early tumor detection. Both methods share the same task of estimating echo signal displacements. To be able to resolve tissue stiffness and vascularity of tumors while still small in size, spatial resolution must be improved. In clinical practice ultrasonic real-time imaging is vital. In this paper we evaluate the performance of several displacement estimators with real-time capability and compare these with results from standard estimators when using echo signals that are typically available with a commercial ultrasound scanner set to yield the highest spatial resolution. Results are from simulations and tissue mimicking phantom experiments using a Voluson 730 scanner (GE Medical Systems Kretztechnik) equipped with a digital research interface and enabling the export of beam-formed radiofrequency (RF) echo data
- 1 April 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 794-799
Infrared Imaging to Measure Temperature Changes of the Extremities caused by Cigarette Smoke and Nicotine Gums
Infrared (IR) image sequences and physiological data (heart rate, blood pressure, blood oxygenation) were acquired in a well-controlled environment adhering to stringent experimental protocols from several test persons who chewed nicotine gums or smoked cigarettes. Task-optimized digital image processing techniques (registration, segmentation, morphological operations) were implemented in a MATLABtrade-based graphical user interface developed for automatic analysis of the acquired infrared images and automatic generation of finger and palm temperature time plots. We found significant temperature decreases due to vasoconstriction mainly in smokers, and temperature increases due to vasodilation mainly in non-smokers. However, the effects of nicotine on vasomotor control, skin vascularization and temperature via the sympathetic nervous system are difficult to assess and also depend on a subject's baseline temperature
- 1 April 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 794-799
Infrared Imaging to Measure Temperature Changes of the Extremities caused by Cigarette Smoke and Nicotine Gums
Infrared (IR) image sequences and physiological data (heart rate, blood pressure, blood oxygenation) were acquired in a well-controlled environment adhering to stringent experimental protocols from several test persons who chewed nicotine gums or smoked cigarettes. Task-optimized digital image processing techniques (registration, segmentation, morphological operations) were implemented in a MATLABtrade-based graphical user interface developed for automatic analysis of the acquired infrared images and automatic generation of finger and palm temperature time plots. We found significant temperature decreases due to vasoconstriction mainly in smokers, and temperature increases due to vasodilation mainly in non-smokers. However, the effects of nicotine on vasomotor control, skin vascularization and temperature via the sympathetic nervous system are difficult to assess and also depend on a subject's baseline temperature
- 22 July 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (7) , 824-835
Adaptive clutter rejection filtering in ultrasonic strain-flow imaging
This paper introduces strain-flow imaging as a potential new technique for investigating vascular dynamics and tumor biology. The deformation of tissues surrounding pulsatile vessels and the velocity of fluid in the vessel are estimated from the same data set. The success of the approach depends on the performance of a digital filter that must separate echo signal components caused by flow from tissue motion components that vary spatially and temporally. Eigenfilters, which are an important tool for naturally separating signal components adaptively throughout the image, perform very well for this task. The method is examined using two tissue-mimicking flow phantoms that provide stationary and moving clutter associated with pulsatile flow.
- 22 July 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (7) , 824-835
Adaptive clutter rejection filtering in ultrasonic strain-flow imaging
This paper introduces strain-flow imaging as a potential new technique for investigating vascular dynamics and tumor biology. The deformation of tissues surrounding pulsatile vessels and the velocity of fluid in the vessel are estimated from the same data set. The success of the approach depends on the performance of a digital filter that must separate echo signal components caused by flow from tissue motion components that vary spatially and temporally. Eigenfilters, which are an important tool for naturally separating signal components adaptively throughout the image, perform very well for this task. The method is examined using two tissue-mimicking flow phantoms that provide stationary and moving clutter associated with pulsatile flow.