Ömer Suat Yaluğ
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ömer Suat Yaluğ has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Dilan Gizem Doğan
Department of Prosthodontics, Faculty of Dentistry, Gazi University, 06490 Ankara, Türkiye
2 shared publications Fatih Mehmet Korkmaz
1 shared publicationHüseyin Yazicioglu
Department of Prosthodontics, Faculty of Dentistry, Gazi University
1 shared publicationHüseyin Yazicioğlu
1 shared publication- Mustafa Kocacikli
GAZİ ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ
1 shared publication
Latest Publications
- Open Access
- 24 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12440
Marginal and Internal Fit of Zirconia Crowns with Varying Yttria Content and Finish Line Configurations: An In Vitro Study
Aim: This in vitro study aimed to evaluate the marginal and internal fit of three monolithic CAD/CAM zirconia ceramics with different Y-TZP contents, prepared with chamfer and rounded shoulder finish lines. Methods. Sixty monolithic zirconia crowns were fabricated and divided into three groups (n = 20) based on their yttria content: (1) multilayer zirconia consisting of a dentin layer of 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) and an incisal layer of 5 mol% partially stabilized zirconia (5Y-PSZ), (2) shade-gradient zirconia fully composed of 3Y-TZP, and (3) shade-gradient zirconia containing 4 mol% partially stabilized zirconia (4Y-PSZ). Each group was further divided into two finish line configurations (chamfer and rounded shoulder). Marginal and internal gaps were measured using the silicone replica technique under a stereomicroscope by a single operator. Data were analyzed using three-way ANOVA followed by Tukey’s post hoc test (α = 0.05). Marginal and internal gaps were assessed using the silicone replica technique under a stereomicroscope by a single operator. Statistical analysis was performed with three-way ANOVA and Tukey’s post hoc test (p < 0.05). Results: The occlusal region exhibited the largest gap values, while the axial region showed the smallest across all groups. Mean marginal and internal gaps were 33.79 µm for chamfer and 43.37 µm for rounded shoulder finish lines. Zirconia with higher Y-TZP content demonstrated significantly greater gap values than those with lower percentages (p < 0.05). Significant interactions were found among finish line design, material type, and measurement region (p < 0.05), with rounded shoulder margins showing larger gaps (p = 0.001). Conclusions: Y-TZP content significantly affects marginal and internal adaptation, with higher percentages associated with increased gap values. Both finish line types produced clinically acceptable fits, although chamfer margins provided superior adaptation.
- 24 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12440
Open AccessMarginal and Internal Fit of Zirconia Crowns with Varying Yttria Content and Finish Line Configurations: An In Vitro Study
Aim: This in vitro study aimed to evaluate the marginal and internal fit of three monolithic CAD/CAM zirconia ceramics with different Y-TZP contents, prepared with chamfer and rounded shoulder finish lines. Methods. Sixty monolithic zirconia crowns were fabricated and divided into three groups (n = 20) based on their yttria content: (1) multilayer zirconia consisting of a dentin layer of 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) and an incisal layer of 5 mol% partially stabilized zirconia (5Y-PSZ), (2) shade-gradient zirconia fully composed of 3Y-TZP, and (3) shade-gradient zirconia containing 4 mol% partially stabilized zirconia (4Y-PSZ). Each group was further divided into two finish line configurations (chamfer and rounded shoulder). Marginal and internal gaps were measured using the silicone replica technique under a stereomicroscope by a single operator. Data were analyzed using three-way ANOVA followed by Tukey’s post hoc test (α = 0.05). Marginal and internal gaps were assessed using the silicone replica technique under a stereomicroscope by a single operator. Statistical analysis was performed with three-way ANOVA and Tukey’s post hoc test (p < 0.05). Results: The occlusal region exhibited the largest gap values, while the axial region showed the smallest across all groups. Mean marginal and internal gaps were 33.79 µm for chamfer and 43.37 µm for rounded shoulder finish lines. Zirconia with higher Y-TZP content demonstrated significantly greater gap values than those with lower percentages (p < 0.05). Significant interactions were found among finish line design, material type, and measurement region (p < 0.05), with rounded shoulder margins showing larger gaps (p = 0.001). Conclusions: Y-TZP content significantly affects marginal and internal adaptation, with higher percentages associated with increased gap values. Both finish line types produced clinically acceptable fits, although chamfer margins provided superior adaptation.
- Open Access
- 20 October 2025
- Published by MDPI AG in Preprints.org
Marginal and Internal Fit of Zirconia Crowns with Varying Yttria Content and Finish Line Configurations: An In Vitro Study
Aim: This in vitro study aimed to evaluate the marginal and internal fit of three monolithic CAD/CAM zirconia ceramics with different Y-TZP contents, prepared with chamfer and rounded shoulder finish lines. Methods. Sixty zirconia crowns were fabricated and equally divided into three material groups, each further subdivided into chamfer and rounded shoulder designs. Marginal and internal gaps were assessed using the silicone replica technique under a stereomicroscope by a single operator. Statistical analysis was performed with three-way ANOVA and Tukey’s post hoc test (p < 0.05). Results: The occlusal region exhibited the largest gap values, while the axial region showed the smallest across all groups. Mean marginal and internal gaps were 33.79 µm for chamfer and 43.37 µm for rounded shoulder finish lines. Zirconia with higher Y-TZP content demonstrated significantly greater gap values than those with lower percentages (p < 0.05). Significant interactions were found among finish line design, material type, and measurement region (P < 0.05), with rounded shoulder margins showing larger gaps (p = 0.001). Conclusions: Y-TZP content significantly affects marginal and internal adaptation, with higher percentages associated with increased gap values. Both finish line types produced clinically acceptable fits, although chamfer margins provided superior adaptation.
- 20 October 2025
- Published by MDPI AG in Preprints.org
Open AccessMarginal and Internal Fit of Zirconia Crowns with Varying Yttria Content and Finish Line Configurations: An In Vitro Study
Aim: This in vitro study aimed to evaluate the marginal and internal fit of three monolithic CAD/CAM zirconia ceramics with different Y-TZP contents, prepared with chamfer and rounded shoulder finish lines. Methods. Sixty zirconia crowns were fabricated and equally divided into three material groups, each further subdivided into chamfer and rounded shoulder designs. Marginal and internal gaps were assessed using the silicone replica technique under a stereomicroscope by a single operator. Statistical analysis was performed with three-way ANOVA and Tukey’s post hoc test (p < 0.05). Results: The occlusal region exhibited the largest gap values, while the axial region showed the smallest across all groups. Mean marginal and internal gaps were 33.79 µm for chamfer and 43.37 µm for rounded shoulder finish lines. Zirconia with higher Y-TZP content demonstrated significantly greater gap values than those with lower percentages (p < 0.05). Significant interactions were found among finish line design, material type, and measurement region (P < 0.05), with rounded shoulder margins showing larger gaps (p = 0.001). Conclusions: Y-TZP content significantly affects marginal and internal adaptation, with higher percentages associated with increased gap values. Both finish line types produced clinically acceptable fits, although chamfer margins provided superior adaptation.
- Open Access
- 1 January 2010
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Medical Sciences
- Vol. 30 (5) , 1750-1755
Fabricating Toe Prostheses Using 3-D Modeling Technique: Case Report
This article describes a technique for making toe prostheses using CAD-CAM technology and a rapid prototyping machine. A laser scanner was used to develop an integrated 3D digital image of the existing toe of a patient subjected to toe ablative surgery. The image was mirrored and used to manufacture the solid toe cast by means of a rapid prototyping machine. Subsequently, the definitive prosthesis was obtained through conventional procedures. Recent studies have focused on computer-assisted rapid prototyping machines to sculpture facial prostheses. Several techniques have been reported to fabricate a mirror-image wax cast for maxillofacial prostheses; however these techniques are costly and may require more time than manual fabrication. Several research protocols have proposed technical computer assisted solutions, however this article describes a simple, inexpensive, and repeatable method of obtaining a definitive wax cast of toe prosthesis.
- 1 January 2010
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Medical Sciences
- Vol. 30 (5) , 1750-1755
Open AccessFabricating Toe Prostheses Using 3-D Modeling Technique: Case Report
This article describes a technique for making toe prostheses using CAD-CAM technology and a rapid prototyping machine. A laser scanner was used to develop an integrated 3D digital image of the existing toe of a patient subjected to toe ablative surgery. The image was mirrored and used to manufacture the solid toe cast by means of a rapid prototyping machine. Subsequently, the definitive prosthesis was obtained through conventional procedures. Recent studies have focused on computer-assisted rapid prototyping machines to sculpture facial prostheses. Several techniques have been reported to fabricate a mirror-image wax cast for maxillofacial prostheses; however these techniques are costly and may require more time than manual fabrication. Several research protocols have proposed technical computer assisted solutions, however this article describes a simple, inexpensive, and repeatable method of obtaining a definitive wax cast of toe prosthesis.
- Open Access
- 1 January 2003
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 45 (1) , 43-45
An alternative approach to fabricating a meatus obturator prosthesis
We describe the fabrication of a meatus obturator prosthesis made with visible light-cured (VLC) resin. The fabrication technique is relatively easy and saves time by eliminating some laboratory procedures for both the patient and the practitioner. The meatus obturator results in a more stable maxillary prosthesis and permits acceptable speech for patients using it.
- 1 January 2003
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 45 (1) , 43-45
Open AccessAn alternative approach to fabricating a meatus obturator prosthesis
We describe the fabrication of a meatus obturator prosthesis made with visible light-cured (VLC) resin. The fabrication technique is relatively easy and saves time by eliminating some laboratory procedures for both the patient and the practitioner. The meatus obturator results in a more stable maxillary prosthesis and permits acceptable speech for patients using it.