Alessandro Pesatori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alessandro Pesatori has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Michele Norgia
Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Via Ponzio 34/5, 20133 Milano, Italy
12 shared publications - Federico Cavedo
Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy
3 shared publications - Parisa Esmaili
Department of Electronics, Information and Bioengineering, Politecnico di Milano, I-20133 Milan, Italy
2 shared publications - Alessandro Palludo
Politecnico di Milano, Dipartimento di Elettronica Informazione e Bioingegneria Piazza Leonardo da Vinci 32, 20131, Milano Italia
1 shared publication Alexey Pniov
Bauman Moscow State Technical University, Centre of Photonic and Infrared Techniques, 2nd Baumanskaya Street, 105005, Moscow
1 shared publication- Andrey A. Zhirnov
Laser and Optoelectronic Systems Department, Radio Electronics and Laser Technology Faculty, Bauman Moscow State Technical University, 2-nd Baumanskaya 5-1, 105005 Moscow, Russia
1 shared publication
Latest Publications
- Open Access
- 1 February 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3179 (1)
Benchmarking of a Cost-effective Micro-Interferometer for Remote Vibration Monitoring
A low-cost and low-size interferometer, based on self-mixing interferometry, has been developed for replacing standard accelerometers. The structure of the micro-interferometer is described in detail, and its measurement performances are evaluated with particular reference to preventive diagnosis of mechanical systems. For this purpose, a test bench equipped with accelerometers was used, on which intact or damaged ball bearings can be mounted. In the experimental tests carried out, the micro-interferometer showed signiAicantly superior performance to accelerometers in reporting faulty behaviour of the mechanical structure.
- 1 February 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3179 (1)
Open AccessBenchmarking of a Cost-effective Micro-Interferometer for Remote Vibration Monitoring
A low-cost and low-size interferometer, based on self-mixing interferometry, has been developed for replacing standard accelerometers. The structure of the micro-interferometer is described in detail, and its measurement performances are evaluated with particular reference to preventive diagnosis of mechanical systems. For this purpose, a test bench equipped with accelerometers was used, on which intact or damaged ball bearings can be mounted. In the experimental tests carried out, the micro-interferometer showed signiAicantly superior performance to accelerometers in reporting faulty behaviour of the mechanical structure.
- Open Access
- 1 February 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3179 (1)
FM Self-mixing Interferometer Measurement Performance
Self-mixing interferometry achieves remarkable performance thanks to the frequency modulation reading. In this case the noise floor is no longer due to shot noise, as for amplitude modulation, but to the laser’s frequency noise. This work experimentally compares the noise floor of this particular kind of interferometer for different laser types, DFB and VCSEL, which exhibit different line broadenings. Experimental measurement of the FM noise spectrum confirms the theoretical treatment that it is determined by the laser’s linewidth. In the particular case of a VCSEL laser, the 1/f noise in frequency modulation clearly indicate a gaussian broadening of the laser linewidth.
- 1 February 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3179 (1)
Open AccessFM Self-mixing Interferometer Measurement Performance
Self-mixing interferometry achieves remarkable performance thanks to the frequency modulation reading. In this case the noise floor is no longer due to shot noise, as for amplitude modulation, but to the laser’s frequency noise. This work experimentally compares the noise floor of this particular kind of interferometer for different laser types, DFB and VCSEL, which exhibit different line broadenings. Experimental measurement of the FM noise spectrum confirms the theoretical treatment that it is determined by the laser’s linewidth. In the particular case of a VCSEL laser, the 1/f noise in frequency modulation clearly indicate a gaussian broadening of the laser linewidth.
- Open Access
Multi-Sensor Laser System for Electric Guitar Pitch-Detection
To attain a direct MIDI output from an electric guitar, we devised and implemented a sophisticated laser sensor system capable of measuring finger positions. This sensor operates on the principle of optical triangulation, employing six lasers and seven position-sensing detectors that are time-multiplexed. The speed and precision of this sensor system meet the necessary criteria for creating an electric guitar with a direct digital output, perfectly satisfying the application’s requirements.
Open AccessMulti-Sensor Laser System for Electric Guitar Pitch-Detection
To attain a direct MIDI output from an electric guitar, we devised and implemented a sophisticated laser sensor system capable of measuring finger positions. This sensor operates on the principle of optical triangulation, employing six lasers and seven position-sensing detectors that are time-multiplexed. The speed and precision of this sensor system meet the necessary criteria for creating an electric guitar with a direct digital output, perfectly satisfying the application’s requirements.
- Open Access
Interferometric Instrument for Thickness Measurement on Blown Films
Real-time measurement of plastic film thickness during production is extremely important to guarantee planarity of the final film. Standard techniques are based on capacitive measurements, in close contact with the film. These techniques require continuous calibration and temperature compensation, while their contact can damage the film. Different optical contactless techniques are described in literature, but none has found application to real production, due to the strong vibration of the films. We propose a new structure of low-coherence fiber interferometer able to measure blown film thickness during productions. The novel fiber-optic setup is a cross between an autocorrelator and a white light interferometer, taking the advantages of both approaches.
Open AccessInterferometric Instrument for Thickness Measurement on Blown Films
Real-time measurement of plastic film thickness during production is extremely important to guarantee planarity of the final film. Standard techniques are based on capacitive measurements, in close contact with the film. These techniques require continuous calibration and temperature compensation, while their contact can damage the film. Different optical contactless techniques are described in literature, but none has found application to real production, due to the strong vibration of the films. We propose a new structure of low-coherence fiber interferometer able to measure blown film thickness during productions. The novel fiber-optic setup is a cross between an autocorrelator and a white light interferometer, taking the advantages of both approaches.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Causes of Error for Turbine Radial Palette Measurement
This paper describes the project of an optical measurement system, an evolution of the system currently installed on the lathe for turbine palettes refinement in Ansaldo Energie, developed by the Politecnico di Milano. This article analyzes the most significant causes of errors found in designing an optical measurement system, proposing improvements that can optimize the system, both in terms of performance and reliability. The idea behind this work is to develop a system that can measure with an accuracy of $10\ \mu\mathrm{m}$ the difference of length of palettes of a turbine stadium in real time, while the turbine is turning on a refinement lathe.- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Causes of Error for Turbine Radial Palette Measurement
This paper describes the project of an optical measurement system, an evolution of the system currently installed on the lathe for turbine palettes refinement in Ansaldo Energie, developed by the Politecnico di Milano. This article analyzes the most significant causes of errors found in designing an optical measurement system, proposing improvements that can optimize the system, both in terms of performance and reliability. The idea behind this work is to develop a system that can measure with an accuracy of $10\ \mu\mathrm{m}$ the difference of length of palettes of a turbine stadium in real time, while the turbine is turning on a refinement lathe.- 5 March 2018
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 57 (05) , 051507-5
Optical proximity sensor based on self-mixing interferometry
A proximity detector based on self-mixing technique, well suited for different industrial applications, is demonstrated. Instead of using a light-source plus a detector, the proposed sensor is realized by a single laser source. Two different physical effects in the laser diode allow for a continuous detecting range, from 10 mm up to 80 mm. The main advantages of the sensor are target detection from just one point of view; multiple sensors configuration does not need optical filters; separation of source and detector is eliminated; and background rejection is intrinsically given by the self-mixing effect, which shows a sharp cut-off after the focus.
- 5 March 2018
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 57 (05) , 051507-5
Optical proximity sensor based on self-mixing interferometry
A proximity detector based on self-mixing technique, well suited for different industrial applications, is demonstrated. Instead of using a light-source plus a detector, the proposed sensor is realized by a single laser source. Two different physical effects in the laser diode allow for a continuous detecting range, from 10 mm up to 80 mm. The main advantages of the sensor are target detection from just one point of view; multiple sensors configuration does not need optical filters; separation of source and detector is eliminated; and background rejection is intrinsically given by the self-mixing effect, which shows a sharp cut-off after the focus.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Simple optical method for measuring oil-mist lubrication
Oil-mist is often used for minimum quantity lubrication of mechanical tools. For the measurement of the oil flow, inside compressed air, we propose a simple optical sensor, realized by a led source and a photodiode. The scattering spectrum, due to the oil particles, provides information about oil percentage and flow speed. The system is described by simulations and experimentally verified. The implemented algorithm allows for real-time measurements, with a low-cost microcontroller. The sensor characterization demonstrates performances and reliability adequate for industrial applications.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Simple optical method for measuring oil-mist lubrication
Oil-mist is often used for minimum quantity lubrication of mechanical tools. For the measurement of the oil flow, inside compressed air, we propose a simple optical sensor, realized by a led source and a photodiode. The scattering spectrum, due to the oil particles, provides information about oil percentage and flow speed. The system is described by simulations and experimentally verified. The implemented algorithm allows for real-time measurements, with a low-cost microcontroller. The sensor characterization demonstrates performances and reliability adequate for industrial applications.
- Open Access
- 30 December 2016
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 5 (4) , 24-28
Yb,Er:glass Microlaser at 1.5 µm for optical fiber sensing: development, characterization and noise reduction
A fiber-pumped single-frequency microchip erbium laser was developed and characterized with the aim of using it in coherent Optical Time Domain Reflectometry (OTDR) measurements and sensing. The laser is pumped by a fiber-coupled 976 nm laser diode and provides 8 mW TEM00 single frequency output power at 1.54 µm wavelength, suitable for efficient coupling to optical fibers. The amplitude and phase noise of this 200 THz oscillator were experimentally investigated and a Relative Intensity Noise (RIN) control loop was developed providing 27 dB RIN peak reduction at the relaxation oscillation frequency of 800 kHz
- 30 December 2016
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 5 (4) , 24-28
Open AccessYb,Er:glass Microlaser at 1.5 µm for optical fiber sensing: development, characterization and noise reduction
A fiber-pumped single-frequency microchip erbium laser was developed and characterized with the aim of using it in coherent Optical Time Domain Reflectometry (OTDR) measurements and sensing. The laser is pumped by a fiber-coupled 976 nm laser diode and provides 8 mW TEM00 single frequency output power at 1.54 µm wavelength, suitable for efficient coupling to optical fibers. The amplitude and phase noise of this 200 THz oscillator were experimentally investigated and a Relative Intensity Noise (RIN) control loop was developed providing 27 dB RIN peak reduction at the relaxation oscillation frequency of 800 kHz
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1740 (1) , 100002
Self-mixing laser sensor for short-distances measurement
This work describes the development of a laser instrument for measuring very-short distances with a minimum sensor size. The absolute distance measurement is obtained through a modulated self-mixing interferometer, realized with a lens-less red VCSEL laser. In a range between 2 mm and 5 mm the sensor shows a resolution of 10 µm at 6.6 kHz of acquisition rate. The sensor size is limited to the laser chip and the contacts; therefore, it is applicable also in very demanding applications, such as the diameter measurement of a hole.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1740 (1) , 100002
Self-mixing laser sensor for short-distances measurement
This work describes the development of a laser instrument for measuring very-short distances with a minimum sensor size. The absolute distance measurement is obtained through a modulated self-mixing interferometer, realized with a lens-less red VCSEL laser. In a range between 2 mm and 5 mm the sensor shows a resolution of 10 µm at 6.6 kHz of acquisition rate. The sensor size is limited to the laser chip and the contacts; therefore, it is applicable also in very demanding applications, such as the diameter measurement of a hole.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1740 (1) , 060002
High-speed rangefinder for industrial application
The proposed work aims to improve one of the most used telemetry techniques to make absolute measurements of distance: the time of flight telemetry. The main limitation of the low-cost implementation of this technique is the low accuracy (some mm) and measurement rate (few measurements per second). In order to overcome these limits we modified the typical setup of this rangefinder exploiting low-cost telecommunication transceivers and radiofrequency synthesizers. The obtained performances are very encouraging, reaching a standard deviation of a few micrometers over the range of some meters.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1740 (1) , 060002
High-speed rangefinder for industrial application
The proposed work aims to improve one of the most used telemetry techniques to make absolute measurements of distance: the time of flight telemetry. The main limitation of the low-cost implementation of this technique is the low accuracy (some mm) and measurement rate (few measurements per second). In order to overcome these limits we modified the typical setup of this rangefinder exploiting low-cost telecommunication transceivers and radiofrequency synthesizers. The obtained performances are very encouraging, reaching a standard deviation of a few micrometers over the range of some meters.