SBS Bayat

S Bayat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


S Bayat has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • A R A Sovijärvi

    Department of Clinical Physiology and Nuclear Medicine, Helsinki University Central Hospital, POB 340, FIN-00029 HUS, Helsinki, Finland

    1 shared publication
  • C G Standertskjöld-Nordenstam

    Department of Radiology, University of Helsinki Central Hospital, POB 340, FIN-00029 HUS, Helsinki, Finland

    1 shared publication
  • C Nemoz

    European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble, France

    1 shared publication
  • G Berruyer

    European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble, France

    1 shared publication
  • G Le Duc

    European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble, France

    1 shared publication
  • Liisa Porra

    Comprehensive Cancer Center, Helsinki University Hospital (HUS) and University of Helsinki, Helsinki, Finland

    1 shared publication

Latest Publications

  • Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent

    by S Bayat, G Le Duc, L Porra, G Berruyer, C Nemoz, S Monfraix, S Fiedler, W Thomlinson, P Suortti, C G Standertskjöld-Nordenstam, et al.

    Small airways play a key role in the distribution of ventilation and in the matching of ventilation to perfusion. The purpose of this study was to introduce an imaging method that allows measurement of regional lung ventilation and evaluation of the function of airways with a small diameter. The experiments were performed at the Medical Beamline of the European Synchrotron Radiation Facility. Monochromatic synchrotron radiation beams were used to obtain quantitative respiration-gated images of lungs and airways in two anaesthetized and mechanically ventilated rabbits using inhaled stable xenon (Xe) gas as a contrast agent. Two simultaneous images were acquired at two different energies, above and below the K-edge of Xe. Logarithmic subtraction of the two images yields absolute Xe concentrations. This technique is known as K-edge subtraction (KES) radiography. Two-dimensional planar and CT images were obtained showing spatial distribution of Xe concentrations within the airspaces, as well as the dynamics of filling with Xe. Bronchi down to 1 mm in diameter were visible both in the subtraction radiographs and in tomographic images. Absolute concentrations of Xe gas were calculated within the tube carrying the inhaled gas mixture, small and large bronchi, and lung tissue. Local time constants of ventilation with Xe were obtained by following the evolution of gas concentration in sequential computed tomography images. The results of this first animal study indicate that KES imaging of lungs with Xe gas as a contrast agent has great potential in studies of the distribution of ventilation within the lungs and of airway function, including airways with a small diameter.