S Bayat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
S Bayat has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A R A Sovijärvi
Department of Clinical Physiology and Nuclear Medicine, Helsinki University Central Hospital, POB 340, FIN-00029 HUS, Helsinki, Finland
1 shared publicationC G Standertskjöld-Nordenstam
Department of Radiology, University of Helsinki Central Hospital, POB 340, FIN-00029 HUS, Helsinki, Finland
1 shared publicationC Nemoz
European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble, France
1 shared publicationG Berruyer
European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble, France
1 shared publicationG Le Duc
European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble, France
1 shared publication- Liisa Porra
Comprehensive Cancer Center, Helsinki University Hospital (HUS) and University of Helsinki, Helsinki, Finland
1 shared publication
Latest Publications
- 14 November 2001
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (12) , 3287-3299
Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent
Small airways play a key role in the distribution of ventilation and in the matching of ventilation to perfusion. The purpose of this study was to introduce an imaging method that allows measurement of regional lung ventilation and evaluation of the function of airways with a small diameter. The experiments were performed at the Medical Beamline of the European Synchrotron Radiation Facility. Monochromatic synchrotron radiation beams were used to obtain quantitative respiration-gated images of lungs and airways in two anaesthetized and mechanically ventilated rabbits using inhaled stable xenon (Xe) gas as a contrast agent. Two simultaneous images were acquired at two different energies, above and below the K-edge of Xe. Logarithmic subtraction of the two images yields absolute Xe concentrations. This technique is known as K-edge subtraction (KES) radiography. Two-dimensional planar and CT images were obtained showing spatial distribution of Xe concentrations within the airspaces, as well as the dynamics of filling with Xe. Bronchi down to 1 mm in diameter were visible both in the subtraction radiographs and in tomographic images. Absolute concentrations of Xe gas were calculated within the tube carrying the inhaled gas mixture, small and large bronchi, and lung tissue. Local time constants of ventilation with Xe were obtained by following the evolution of gas concentration in sequential computed tomography images. The results of this first animal study indicate that KES imaging of lungs with Xe gas as a contrast agent has great potential in studies of the distribution of ventilation within the lungs and of airway function, including airways with a small diameter.
- 14 November 2001
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (12) , 3287-3299
Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent
Small airways play a key role in the distribution of ventilation and in the matching of ventilation to perfusion. The purpose of this study was to introduce an imaging method that allows measurement of regional lung ventilation and evaluation of the function of airways with a small diameter. The experiments were performed at the Medical Beamline of the European Synchrotron Radiation Facility. Monochromatic synchrotron radiation beams were used to obtain quantitative respiration-gated images of lungs and airways in two anaesthetized and mechanically ventilated rabbits using inhaled stable xenon (Xe) gas as a contrast agent. Two simultaneous images were acquired at two different energies, above and below the K-edge of Xe. Logarithmic subtraction of the two images yields absolute Xe concentrations. This technique is known as K-edge subtraction (KES) radiography. Two-dimensional planar and CT images were obtained showing spatial distribution of Xe concentrations within the airspaces, as well as the dynamics of filling with Xe. Bronchi down to 1 mm in diameter were visible both in the subtraction radiographs and in tomographic images. Absolute concentrations of Xe gas were calculated within the tube carrying the inhaled gas mixture, small and large bronchi, and lung tissue. Local time constants of ventilation with Xe were obtained by following the evolution of gas concentration in sequential computed tomography images. The results of this first animal study indicate that KES imaging of lungs with Xe gas as a contrast agent has great potential in studies of the distribution of ventilation within the lungs and of airway function, including airways with a small diameter.