William L. Roberts
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
William L. Roberts has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Linda Moulton
5 shared publicationsElizabeth L Frank
University of Utah, Department of Pathology, Salt Lake City 84108, USA
2 shared publicationsAnthony Spencer
Departments of Laboratory Medicine and Pathology, Children’s Hospital and Harvard Medical School, Boston, MA 02115
1 shared publicationBarun K De
Department of Pathology, University of Mississippi Medical Center, Jackson, MS 39216
1 shared publicationBarun K. De
1 shared publicationChing-Nan Ou
Department of Pathology, Texas Children’s Hospital and Baylor College of Medicine, Houston, TX 77030
1 shared publication
Latest Publications
- 1 April 2001
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 23 (2) , 148-154
Performance Characteristics of Four Free Phenytoin Immunoassays
The measurement of the unbound or free phenytoin concentration is indicated in several situations, including uremia. In patients with uremia, metabolites of phenytoin and other substances accumulate and can displace phenytoin from its protein binding sites, with a consequent increase in the free fraction of drug. Some of the phenytoin metabolites that accumulate in uremia can cross-react with phenytoin immunoassays. In this study the authors evaluated four free phenytoin immunoassays compared with a high-performance liquid chromatography (HPLC) method: the Roche COBAS Integra, the Syva EMIT 2000, the Opus INNOFLUOR, and the Abbott TDx. All four methods demonstrated good precision, with interday coefficients of variation of ≤5% and comparable recoveries using quality control material. Two of the methods, the EMIT 2000 and COBAS Integra, showed excellent agreement with the HPLC method using samples from patients both with normal renal function and with renal insufficiency. The other two methods, the INNOFLUOR and TDx, showed average positive biases for the therapeutic range of 3–7% and 21–22%, respectively, compared with the HPLC method for samples from patients with normal renal function, and average positive biases of 24–32% and 75–81%, respectively, with samples from patients with uremia.
- 1 April 2001
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 23 (2) , 148-154
Performance Characteristics of Four Free Phenytoin Immunoassays
The measurement of the unbound or free phenytoin concentration is indicated in several situations, including uremia. In patients with uremia, metabolites of phenytoin and other substances accumulate and can displace phenytoin from its protein binding sites, with a consequent increase in the free fraction of drug. Some of the phenytoin metabolites that accumulate in uremia can cross-react with phenytoin immunoassays. In this study the authors evaluated four free phenytoin immunoassays compared with a high-performance liquid chromatography (HPLC) method: the Roche COBAS Integra, the Syva EMIT 2000, the Opus INNOFLUOR, and the Abbott TDx. All four methods demonstrated good precision, with interday coefficients of variation of ≤5% and comparable recoveries using quality control material. Two of the methods, the EMIT 2000 and COBAS Integra, showed excellent agreement with the HPLC method using samples from patients both with normal renal function and with renal insufficiency. The other two methods, the INNOFLUOR and TDx, showed average positive biases for the therapeutic range of 3–7% and 21–22%, respectively, compared with the HPLC method for samples from patients with normal renal function, and average positive biases of 24–32% and 75–81%, respectively, with samples from patients with uremia.
- Open Access
- 1 June 2000
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 46 (6) , 864-867
Effects of Hemoglobin C and S Traits on Seven Glycohemoglobin Methods
Glycohemoglobin (gHb) is a marker of long-term glycemic control that has been shown to correlate with complications of diabetes mellitus (1). The National Glycohemoglobin Standardization Program (NGSP) was established to standardize gHb results so that clinical laboratory results are comparable to those reported by the Diabetes Control and Complications Trial (2)(3). Previous studies have shown that some gHb methods yield inaccurate results with samples heterozygous for hemoglobin (Hb) C or Hb S (4)(5)(6). At least 10% of black Americans have either Hb C or S trait, and there were 19 million black Americans over age 19 in 1990 (7)(8)(9)(10). The prevalence of diabetes is estimated to be 5.1% of the adult population, with the rate for non-Hispanic blacks being 1.6-fold higher than that of non-Hispanic whites (11). It is therefore probable that at least 150 000 Americans with diabetes have Hb C or S trait. Here, we investigate the measurement of gHb in specimens containing Hb C or S trait using eight gHb methods currently in clinical use.
- 1 June 2000
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 46 (6) , 864-867
Open AccessEffects of Hemoglobin C and S Traits on Seven Glycohemoglobin Methods
Glycohemoglobin (gHb) is a marker of long-term glycemic control that has been shown to correlate with complications of diabetes mellitus (1). The National Glycohemoglobin Standardization Program (NGSP) was established to standardize gHb results so that clinical laboratory results are comparable to those reported by the Diabetes Control and Complications Trial (2)(3). Previous studies have shown that some gHb methods yield inaccurate results with samples heterozygous for hemoglobin (Hb) C or Hb S (4)(5)(6). At least 10% of black Americans have either Hb C or S trait, and there were 19 million black Americans over age 19 in 1990 (7)(8)(9)(10). The prevalence of diabetes is estimated to be 5.1% of the adult population, with the rate for non-Hispanic blacks being 1.6-fold higher than that of non-Hispanic whites (11). It is therefore probable that at least 150 000 Americans with diabetes have Hb C or S trait. Here, we investigate the measurement of gHb in specimens containing Hb C or S trait using eight gHb methods currently in clinical use.
- Open Access
- 1 April 2000
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 46 (4) , 461-468
Evaluation of Four Automated High-Sensitivity C-Reactive Protein Methods: Implications for Clinical and Epidemiological Applications
Background: C-reactive protein (CRP) can provide prognostic information about the risk of developing atherosclerotic complications in apparently healthy patients. This new clinical application requires quantification of CRP concentrations below those traditionally measured in the clinical laboratory. Methods: The Dade Behring BN II, the Abbott IMx, the Diagnostic Products Corporation IMMULITE, and the Beckman Coulter IMMAGE are four automated analyzers with high-sensitivity CRP (hs-CRP) methods. We evaluated these assays for precision, linearity, and comparability with samples from 322 apparently healthy blood donors. Results: The imprecision (CV) of the BN II, IMx, IMMULITE, and IMMAGE methods was ≤7.6%, ≤12%, ≤9.8%, and ≤9.7% at 3.5 mg/L, respectively. The BN II, IMx, IMMULITE, and IMMAGE methods were linear down to ≤0.30, ≤0.32, ≤0.85, and 2.26 mg/L, respectively. CRP concentrations demarcating each quartile in a healthy population were method dependent. The IMx method gave results comparable to the BN II method for values in the reference interval. The IMMULITE method had a positive intercept compared with the BN II method. The IMMAGE method demonstrated more scatter and a positive intercept compared with the BN II method, which may reflect the fact that it is a less sensitive assay. Conclusions: The four hs-CRP methods exhibited differences in results for a healthy population. Additional standardization efforts are required to ensure that hs-CRP results can be related to large-scale epidemiologic studies.
- 1 April 2000
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 46 (4) , 461-468
Open AccessEvaluation of Four Automated High-Sensitivity C-Reactive Protein Methods: Implications for Clinical and Epidemiological Applications
Background: C-reactive protein (CRP) can provide prognostic information about the risk of developing atherosclerotic complications in apparently healthy patients. This new clinical application requires quantification of CRP concentrations below those traditionally measured in the clinical laboratory. Methods: The Dade Behring BN II, the Abbott IMx, the Diagnostic Products Corporation IMMULITE, and the Beckman Coulter IMMAGE are four automated analyzers with high-sensitivity CRP (hs-CRP) methods. We evaluated these assays for precision, linearity, and comparability with samples from 322 apparently healthy blood donors. Results: The imprecision (CV) of the BN II, IMx, IMMULITE, and IMMAGE methods was ≤7.6%, ≤12%, ≤9.8%, and ≤9.7% at 3.5 mg/L, respectively. The BN II, IMx, IMMULITE, and IMMAGE methods were linear down to ≤0.30, ≤0.32, ≤0.85, and 2.26 mg/L, respectively. CRP concentrations demarcating each quartile in a healthy population were method dependent. The IMx method gave results comparable to the BN II method for values in the reference interval. The IMMULITE method had a positive intercept compared with the BN II method. The IMMAGE method demonstrated more scatter and a positive intercept compared with the BN II method, which may reflect the fact that it is a less sensitive assay. Conclusions: The four hs-CRP methods exhibited differences in results for a healthy population. Additional standardization efforts are required to ensure that hs-CRP results can be related to large-scale epidemiologic studies.
- Open Access
- 1 April 2000
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 46 (4) , 560-576
Effects of Nine Hemoglobin Variants on Five Glycohemoglobin Methods
Most studies of the effects of variant hemoglobins (Hbs) on specific glycohemoglobin (gHb) methods have been case reports of a single variant Hb and one or two analytical methods ( 1)( 2)( 3)( 4). Few studies have systematically examined multiple Hb variants with several widely used analytical methods. In this report, we describe the effects of nine heterozygous Hb variants on five gHb methods. A boronate affinity method was chosen as the comparative method because it has high specificity for glycated Hb and negligible interference by variant Hbs ( 5).
- 1 April 2000
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 46 (4) , 560-576
Open AccessEffects of Nine Hemoglobin Variants on Five Glycohemoglobin Methods
Most studies of the effects of variant hemoglobins (Hbs) on specific glycohemoglobin (gHb) methods have been case reports of a single variant Hb and one or two analytical methods ( 1)( 2)( 3)( 4). Few studies have systematically examined multiple Hb variants with several widely used analytical methods. In this report, we describe the effects of nine heterozygous Hb variants on five gHb methods. A boronate affinity method was chosen as the comparative method because it has high specificity for glycated Hb and negligible interference by variant Hbs ( 5).
- Open Access
- 1 April 2000
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 46 (4) , 560-576
Falsely Low Direct HDL-Cholesterol Results in a Patient with Dysbetalipoproteinemia
Direct methods for measuring HDL-cholesterol (HDL-C) are becoming more widely used because of their labor savings and favorable performance characteristics. We investigated three methodologies for direct HDL-C measurements. All three contain an initial reagent to block measurement of cholesterol in lipoproteins other than HDL, followed by a second reagent to measure HDL-C. The performance of each of these assays has been evaluated previously ( 1)( 2)( 3)( 4)( 5)( 6)( 7)( 8). All of these direct assays appear to be relatively free of common interferences; however, triglycerides >10 g/L may affect recoveries. There are minimal published data on these new direct methods with patients who have a dyslipidemia or are receiving lipid-modifying drugs. In this report, we describe a patient with type III hyperlipidemia for whom three direct HDL-C assays yielded erroneously low results compared with traditional HDL-C methods.
- 1 April 2000
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 46 (4) , 560-576
Open AccessFalsely Low Direct HDL-Cholesterol Results in a Patient with Dysbetalipoproteinemia
Direct methods for measuring HDL-cholesterol (HDL-C) are becoming more widely used because of their labor savings and favorable performance characteristics. We investigated three methodologies for direct HDL-C measurements. All three contain an initial reagent to block measurement of cholesterol in lipoproteins other than HDL, followed by a second reagent to measure HDL-C. The performance of each of these assays has been evaluated previously ( 1)( 2)( 3)( 4)( 5)( 6)( 7)( 8). All of these direct assays appear to be relatively free of common interferences; however, triglycerides >10 g/L may affect recoveries. There are minimal published data on these new direct methods with patients who have a dyslipidemia or are receiving lipid-modifying drugs. In this report, we describe a patient with type III hyperlipidemia for whom three direct HDL-C assays yielded erroneously low results compared with traditional HDL-C methods.
- Open Access
- 1 June 1999
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 45 (6) , 829-837
Falsely Increased Immunoassay Measurements of Total and Unbound Phenytoin in Critically Ill Uremic Patients Receiving Fosphenytoin
Background: Fosphenytoin, a phosphate ester prodrug of phenytoin, is metabolized to phenytoin in vivo. Phenytoin metabolites accumulate in renal insufficiency and cross-react in some phenytoin immunoassays. Our aim was to determine the accuracy of phenytoin immunoassays in renal patients treated with fosphenytoin. Methods: We measured phenytoin with HPLC and with the aca, ACS:180, TDx phenytoin II, Vitros, and AxSYM methods. Specimens were collected 2–120 h after fosphenytoin administration from 17 patients with renal insufficiency. Results: The AxSYM, TDx phenytoin II, ACS:180, and Vitros assays displayed falsely increased phenytoin results up to 20 times higher than the HPLC results. The aca Star results for these specimens were comparable to the HPLC results. Although fosphenytoin can cross-react with phenytoin immunoassays, no fosphenytoin was detected by a sensitive HPLC method in any sample that was tested for its presence. Conclusion: These results are consistent with the formation of one or more novel metabolites or adducts of fosphenytoin that accumulate in some critically ill patients with renal insufficiency and that display significant cross-reactivity with some, but not all, phenytoin immunoassay methods.
- 1 June 1999
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 45 (6) , 829-837
Open AccessFalsely Increased Immunoassay Measurements of Total and Unbound Phenytoin in Critically Ill Uremic Patients Receiving Fosphenytoin
Background: Fosphenytoin, a phosphate ester prodrug of phenytoin, is metabolized to phenytoin in vivo. Phenytoin metabolites accumulate in renal insufficiency and cross-react in some phenytoin immunoassays. Our aim was to determine the accuracy of phenytoin immunoassays in renal patients treated with fosphenytoin. Methods: We measured phenytoin with HPLC and with the aca, ACS:180, TDx phenytoin II, Vitros, and AxSYM methods. Specimens were collected 2–120 h after fosphenytoin administration from 17 patients with renal insufficiency. Results: The AxSYM, TDx phenytoin II, ACS:180, and Vitros assays displayed falsely increased phenytoin results up to 20 times higher than the HPLC results. The aca Star results for these specimens were comparable to the HPLC results. Although fosphenytoin can cross-react with phenytoin immunoassays, no fosphenytoin was detected by a sensitive HPLC method in any sample that was tested for its presence. Conclusion: These results are consistent with the formation of one or more novel metabolites or adducts of fosphenytoin that accumulate in some critically ill patients with renal insufficiency and that display significant cross-reactivity with some, but not all, phenytoin immunoassay methods.