Johan M. Bosmans
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Johan M. Bosmans has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Christiaan J. Vrints
2 shared publications- Hidde Bult
Laboratory of Physiopharmacology; University of Antwerp; Antwerp, Belgium
2 shared publications - Anne Vorlat
Department of Cardiology, Antwerp University Hospital, Edegem, Belgium
1 shared publication Chris J. Vrints
Department of Cardiology, University Hospital Antwerp, Antwerp, Belgium
1 shared publication- Christiaan J. Vrints
Cardiovascular Diseases, Department of Translational Pathophysiological Research, University of Antwerp, Campus Drie Eiken, Universiteitsplein 1, 2610 Wilrijk, Belgium; Laboratory of Cellular and Molecular Cardiology, Department of Cardiology, Antwerp University Hospital, Wilrijkstraat 10, 2650 Edegem, Belgium
1 shared publication Christophe J. Van Dyck
Department of Cardiology, Laboratory for Cellular and Molecular Cardiology, Antwerp University Hospital, Antwerp, Belgium
1 shared publication
Latest Publications
- 24 September 2012
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 81 (7) , E259-E268
Resolute® and xience V® polymer‐based drug‐eluting stents compared in an atherosclerotic rabbit double injury model
Aim To evaluate differences in strut coverage, inflammation and endothelialization between two second‐generation polymer‐based drug‐eluting stents (DES) in an atherosclerotic rabbit double‐injury iliac artery model at 28 days follow‐up. Methods and results: Rabbits with induced atheroma received bilateral iliac artery stents: everolimus‐eluting stent (Xience V EES; Abbott Vascular), zotarolimus‐eluting stent (Resolute ZES; Medtronic CardioVascular), or bare‐metal stent (BMS; MultiLink Vision; Abbott Vascular). After 28 days, total neointimal coverage examined by scanning electron microscopy was >98% for all three stent types. Neointimal thickness above stent struts was decreased by 50% in Xience V EES (0.06 ± 0.01 mm; P = 0.00001) compared with BMS (0.15 ± 0.03 mm) and Resolute ZES (0.12 ± 0.04 mm). Luminal area was largest for Xience V EES (3.79 ± 0.33 mm2; P = 0.0003 for Xience V EES vs. BMS), followed by Resolute ZES (3.46 ± 0.45 mm2; P = 0.083 for Resolute ZES vs. BMS) and BMS (3.07 ± 0.53 mm2). Percentage area stenosis was smallest for Xience V EES (17.23 ± 3.64%; P = 0.00001), while BMS (30.25 ± 7.48%) and Resolute ZES (30.79 ± 7.15%) did not differ. Endothelial monolayer regrowth was significantly lower in Resolute ZES (65 ± 13%) versus BMS (79 ± 11%; P = 0.004). There was no difference between Xience V EES (74 ± 10%) and BMS. Xience V EES was further associated with a lower number of inflammatory cells surrounding the stent struts (7 ± 2 per strut) in comparison to Resolute ZES (15 ± 6; P = 0.0001) and BMS (17 ± 9; P = 0.0005). Conclusion In this atherosclerotic rabbit model, Xience V EES suppressed neointimal thickening better, with normal endothelial regrowth as compared with BMS, and less strut‐induced inflammation.
- 24 September 2012
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 81 (7) , E259-E268
Resolute® and xience V® polymer‐based drug‐eluting stents compared in an atherosclerotic rabbit double injury model
Aim To evaluate differences in strut coverage, inflammation and endothelialization between two second‐generation polymer‐based drug‐eluting stents (DES) in an atherosclerotic rabbit double‐injury iliac artery model at 28 days follow‐up. Methods and results: Rabbits with induced atheroma received bilateral iliac artery stents: everolimus‐eluting stent (Xience V EES; Abbott Vascular), zotarolimus‐eluting stent (Resolute ZES; Medtronic CardioVascular), or bare‐metal stent (BMS; MultiLink Vision; Abbott Vascular). After 28 days, total neointimal coverage examined by scanning electron microscopy was >98% for all three stent types. Neointimal thickness above stent struts was decreased by 50% in Xience V EES (0.06 ± 0.01 mm; P = 0.00001) compared with BMS (0.15 ± 0.03 mm) and Resolute ZES (0.12 ± 0.04 mm). Luminal area was largest for Xience V EES (3.79 ± 0.33 mm2; P = 0.0003 for Xience V EES vs. BMS), followed by Resolute ZES (3.46 ± 0.45 mm2; P = 0.083 for Resolute ZES vs. BMS) and BMS (3.07 ± 0.53 mm2). Percentage area stenosis was smallest for Xience V EES (17.23 ± 3.64%; P = 0.00001), while BMS (30.25 ± 7.48%) and Resolute ZES (30.79 ± 7.15%) did not differ. Endothelial monolayer regrowth was significantly lower in Resolute ZES (65 ± 13%) versus BMS (79 ± 11%; P = 0.004). There was no difference between Xience V EES (74 ± 10%) and BMS. Xience V EES was further associated with a lower number of inflammatory cells surrounding the stent struts (7 ± 2 per strut) in comparison to Resolute ZES (15 ± 6; P = 0.0001) and BMS (17 ± 9; P = 0.0005). Conclusion In this atherosclerotic rabbit model, Xience V EES suppressed neointimal thickening better, with normal endothelial regrowth as compared with BMS, and less strut‐induced inflammation.
- 2 January 2007
- Published by Elsevier in International Journal of Cardiology
- Vol. 114 (1) , 46-49
B-type natriuretic peptide and assessment of jeopardised myocardium in acute myocardial infarction
- 2 January 2007
- Published by Elsevier in International Journal of Cardiology
- Vol. 114 (1) , 46-49
B-type natriuretic peptide and assessment of jeopardised myocardium in acute myocardial infarction
- 1 January 2007
- Published by Elsevier in Cardiovascular Pathology
- Vol. 16 (1) , 43-50
Stereology: a simplified and more time-efficient method than planimetry for the quantitative analysis of vascular structures in different models of intimal thickening
- 1 January 2007
- Published by Elsevier in Cardiovascular Pathology
- Vol. 16 (1) , 43-50
Stereology: a simplified and more time-efficient method than planimetry for the quantitative analysis of vascular structures in different models of intimal thickening
- 12 May 2000
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 50 (1) , 105-108
Unsuccessful long-term outcome after treatment of a vein graft false aneurysm with a polytetrafluoethylene-coated Jostent
We describe a case in which a stented ulcerated plaque in an old vein graft ruptured to a huge false aneurysm. By the use of a PTFE‐coated Jostent, the false aneurysm could be percutaneously closed. However, 6 months later, a new false aneurysm, probably due to focal perforation of the covered Jostent, developed. Cathet. Cardiovasc. Intervent. 50:105–108, 2000.
- 12 May 2000
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 50 (1) , 105-108
Unsuccessful long-term outcome after treatment of a vein graft false aneurysm with a polytetrafluoethylene-coated Jostent
We describe a case in which a stented ulcerated plaque in an old vein graft ruptured to a huge false aneurysm. By the use of a PTFE‐coated Jostent, the false aneurysm could be percutaneously closed. However, 6 months later, a new false aneurysm, probably due to focal perforation of the covered Jostent, developed. Cathet. Cardiovasc. Intervent. 50:105–108, 2000.