DBDietrich Banzer

Dietrich Banzer

*This is an algorithmically generated author record based on publicly available information.

Dietrich Banzer has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Shape model-based semi-automatic morphometric assessment of vertebral deformities in clinical practice

    by R. Andresen, D. Banzer, G. Möller

    The accurate and clear reporting of vertebral fractures in routine clinical practice is essential to ensure that patients with osteoporosis receive appropriate treatment to prevent the occurrence of further fractures. A statistical shape model-based vision system for semi-automated morphometry called MorphoXpress® has been developed and needs to be tested in routine clinical practice. This multi-centre medical practice evaluation pilot study compared the degree of agreement between two methods to detect vertebral body deformities in routine clinical practice: qualitative visual evaluation of conventional lateral thoracic and lumbar spine radiographs as a “gold standard” and the MorphoXpress® semi-automatic software system for vertebral morphometry. This pilot study was performed in seven participating osteo-centers in Germany. The analysis included 223 ambulatory patients with 446 conventional lateral thoracic (n = 223) and lumbar (n = 223) spine radiographs showing 2676 vertebrae from T5 to L4. Qualitative visual radiograph evaluation was performed by clinician experts, who classified vertebral shape as fractured or not fractured. MorphoXpress® was used for quantitative assessment of vertebral height in digitized radiographs by localising all morphometric points within the set range of vertebrae based on a statistical model-based vision system. Using the interactive tools in Morpho Xpress→, clinicians could refine the positions of morphometric points to their satisfaction. Agreement between the two methods was analyzed. Using qualitative visual radiograph evaluation, clinicians recognised fractures in 92 (41.3 %) patients while quantitative evaluation with MorphoXpress®with interactive manual corrections detected fractures in 85 (38.1 %) patients. Distribution of fractures was comparable using the two methods. The Morpho Xpress→ system alone identified 76 % of the fractured vertebrae correctly. This result was improved to 98 % using additional manual corrections by the clinician once. The overall mean time needed for MorphoXpress® fracture morphometric assessment of vertebral fractures in clinical practice took 13 minutes and 36 seconds. Quantitative measurement using the current version of the MorphoXpress® software system for vertebral morphometry in combination with qualitative interactive corrections by clinicians seems to be a valuable tool for assessment and follow-up documentation of osteoporotic vertebral deformities in patients without severe scoliosis in epidemiological studies and clinical drug trials only. Currently the technique is too timeconsuming and only after significant improvement of the procedure time and following appropriate training for physicians, MorphoXpress® vertebral morphometry could be a valuable tool in daily routine clinical use for osteoporotic patients. Die akkurate Befundung von Wirbelkörperfrakturen in der klinischen Routine Praxis ist essenziell, damit Patienten mit Osteoporose die notwendige Behandlung zur Vermeidung von weiteren Frakturen erhalten. MorphoXpress®, ein statistisches Form modell-gestütztes Visions-System zur halbautomatischen Wirbelkörper-Morphometrie, wurde entwickelt und soll in der klinischen Anwendung getestet werden. Diese erste deutsche multizentrische Anwendungsbeobachtung vergleicht den Grad der Übereinstimmung zweier Methoden zur Erkennung von Wirbelkörperdeformitäten: Qualitative visuelle Auswertung von konventionellen lateralen Brust und Lendenwirbelsäulen Röntgenaufnahmen als „Goldstandard” versus MorphoXpress®, einem halbautomatischen Software-System zur Wirbelkörper Morphometrie. Die Pilotstudie wurde in sieben osteologischen Zentren in Deutschland durchgeführt. Die Analyse schloss 223 ambulante Patienten mit 446 konventionellen lateralen Brust (n = 223) und Lendenwirbelsäulen Röntgenaufnahmen (n = 223) mit 2676 Wirbelkörpern von BWK 5 bis LWK 4 ein. Die qualitative visuelle Auswertung der Röntgenbilder wurde von klinisch tätigen Ärzten durchgeführt, die Wirbelkörper als frakturiert oder nicht frakturiert klassifizierten. MorphoXpress® wurde zur quantitativen Evaluation der Wirbelkörperhöhe in digitalisierten Röntgenaufnahmen genutzt, indem morphometrische Punkte innerhalb der ausgewählten Wirbelkörper in einem statistischen Formmodell gestützten Visionssystem gesetzt wurden. Beim Gebrauch des interaktiven MorphoXpress®-Systems konnten die klinischen Anwender die Positionen der morphometrischen Punkte revidieren. Die Übereinstimmung zwischen beiden Methoden wurde analysiert. Bei der qualitativen visuellen Auswertung der Röntgenaufnahmen entdeckten die klinischen Untersucher Frakturen bei 92 (41,3 %) Patienten während bei der Evaluation mittels MorphoXpress® kombiniert mit interaktiven manuellen Korrekturen bei 85 (38,1 %) Patienten Frakturen festgestellt wurden. Die Verteilung der Frakturen war vergleichbar bei beiden Methoden. Das MorphoXpress®-System alleine identifizierte 76 % der frakturierten Wirbelkörper richtig. Dieses Ergebnis wurde durch zusätzliche einmalige manuelle Korrekturen durch die klinischen Untersucher auf 98 % verbessert. Der zeitliche Mittelwert in der klinischen Anwendung für die morphometrische Erfassung der Wirbelkörperfrakturen mittels Morpho Xpress→ betrug 13 Minuten und 36 Sekunden. Die quantitative Auswertung mit der aktuellen Version des Morpho Xpress→-Software-Systems zur Wirbelkörper Morphometrie in Verbindung mit qualitativen interaktiven Korrekturen der klinischen Untersucher scheint nur ein nützliches Instrument zur Erfassung und zur Followup Dokumentation von osteoporotischen Wirbelkörperdeformationen bei Patienten ohne ausgeprägte Skoliose in epidemiologischen und klinischen Therapiestudien zu sein....


    • 1 January 2001
      • Vol. 54  (3) , 114-9

    [Imaging and therapy of hamulus-ossis-hamati fracture].

    by R Andresen, S Radmer, O Scheufler, D Banzer

    The relatively rare fractures of the hamate bone are the most common osseous injuries of the distal carpal row, whereby fractures of both the body and the hook of the hamate occur. We present a hamulus ossis hamate fracture that was caused by direct trauma in a high-level game of underwater rugby. Although this was diagnosed by conventional x-ray, the precise position of the fracture was clearly imaged using thin-layer CT, while additional multiplanar MRT revealed further sequelae of the trauma. A CT follow-up after 10 weeks of conservative therapy did not show any osseous consolidation, which indicated the need for surgical revision with extirpation of the hamulus.


    • 1 January 2000
      • Vol. 125  (1) , 56-9

    [Catheter ablation of the inferior epigastric artery. An conservative method for conditioning the pedicled TRAM flap].

    by D Banzer, R Andresen, A Kirsch, E Vaubel

    The pedicled transverse rectus abdominis musculocutaneous (TRAM) flap is a recognized, reliable method of autogenous tissue breast reconstruction after mastectomy. However, the blood supply to the distal part of the flap is often precarious after ligation of the the main feeder, the inferior epigastric artery (AEI), at time of the operation. We describe our clinical experience with a new technique to augment the superior blood stream (superior epigastric artery, AES) by selective embolization of the inferior epigastric artery some weeks prior to plastic surgery. One hundred and eleven embolization procedures were performed until now. Technique of crossover and ipsilateral epigastric spiral embolization is described, requiring minimal time and material as an in- or outpatient procedure. The anatomical situation of the m. rectus abdominis blood supply is discussed as well as possible complications of the procedure.

    • 1 January 2000
      • Vol. 125  (1) , 60-7

    [Clinical results and color-coded duplex ultrasound findings 4 years after conditioned TRAM flap-plasty].

    by O Scheufler, R Andresen, A Kirsch, D Banzer, E Vaubel

    Presented is a new technique in preoperative conditioning of the pedicled TRAM-flap employing an interventional-radiologic procedure, selective embolization of the deep inferior epigastric artery (DIEA). During a four year period in 40 patients with a mean age of 48.4 (31-66) years breast reconstruction was performed by a superiorly pedicled TRAM-flap following preoperative conditioning. 30 of 40 patients were eligible for follow-up one to five years postoperatively. The mean interval between embolization and surgery amounted to 3.6 months. In 25 of 30 cases embolization of the DIEA was performed bilaterally, in 5 of 30 cases unilaterally. 14 of 30 patients underwent preoperative radiotherapy for breast cancer. Applying CCDS the peak flow values were determined in the superior epigastric arteries (TRAM/contralateral side). Pre-embolization values (54.9 cm/s/55.8 cm/s), post-embolization values (57.2 cm/s/57.9 cm/s) and late postoperative values (61.0 cm/s/61.6 cm/s) proved a statistically significant effect of selective embolization on peak flow without relevant difference between TRAM and contralateral side (p < 0.05). Postoperative flap complications consisted of partial necrosis in 2 of 30, fat necrosis in 1 of 30, impaired would healing in 5 of 30 and postoperative bleeding in 2 of 30 cases. Abdominal would healing complications occurred in 5 of 30 cases, abdominal wall weakness was found in 8 of 30 and hernia formation in 4 of 30 cases. Corrective surgery was performed at the breast (TRAM-flap) in 22 of 30 and at the abdomen (donor site) in 9 of 30 cases. Patient acceptance concerning selective embolization and TRAM-flap surgery was very high. 29 of 30 patients confirmed that they would again choose this type of breast reconstruction. The pedicled TRAM-flap following preoperative conditioning by selective embolization of the DIEA constitutes a safe and reliable method of breast reconstruction with autogenous tissue. It is superior to the pedicled TRAM-flap without delay and offers definite advantages compared to alternative techniques of enhanced flap vascularization.


    • 1 January 1999
      • Vol. 52, 206-9

    [Tracheobronchial amyloidosis as the cause of a middle lobe syndrome].

    by T Rehbock, R Andresen, B Rehbock, C Ruettgard, D Banzer

  • Darstellung von Os hamatum-Frakturen im konventionellen Röntgenbild und CT: Experimentelle Ergebnisse sowie klinische Erfahrungen

    by R. Andresen, S. Radmer, J. Brossmann, D. Sartoris, M. Sparmann, G. Bogusch, D. Banzer

    Examination of the ability to image fractures of the body and hook of the hamate bone in conventional X-rays and HR-CT. In an in vitro experiment on 18 cadaver hands, the hamate bone was fractured at different localisations. Before and after fracture, conventional x-rays were taken in different projectional planes: a.-p., lateral, oblique and carpal tunnel view, as well as an HR-CT with 2 mm layer thickness in the axial, sagittal and coronal plane. In addition, 15 clinically verified hamate bone fractures (two body and 13 hook of hamate fractures) were reviewed retrospectively to assess the value of the imaging procedures that led to diagnosis. Taking into account all conventional x-ray projections applied, the in vitro experiment yielded a sensitivity of 72.2%, a specificity of 88.8% and an accuracy of 80.5%. For CT, the sensitivity was 100%, the specificity 94.4% and the accuracy 97.2%. In retrospective clinical evaluation, 60% of the existing fractures were identified in the conventional x-ray images. The remaining fractures were detected by additional procedures like scintigraphy, conventional tomography and CT. For the diagnosis of fractures of the body and hook of the hamate HR-CT is the imaging procedure of choice, in which case an axial or sagittal plane should be chosen.


  • Knochendichte von Spongiosa und Kortikalis der Lendenwirbelsäule

    by Dietrich Banzer, Caius Fabian, Reimer Andresen, Jens -Peter Banzer, Dieter Felsenberg, Walter Reisinger, Karl -Mathias Neher

    □Background and Method: In an additional bone density measurement protocol to the European Vertebral Osteoporosis Study (EVOS) separate spongious and cortical density measurements (sQCT) were carried out at the first 3 lumbar vertebrae in 293 volunteers (92 men and 201 women) in 3 Berlin regional centers. □Results: The spongious mineral density decreases from proximal to distal (L1 to L3), the cortical density increases from proximal to distal, mainly in men. Men showed no significant decrease of cortical density and a lower decrease of spongious density with age compared to women. A comparison of bone mineral density with vertebral height indices of McCloskey/Kanis, Eastell/Melton and Felsenberg showed significant differences of spongious density between a group with normal vertebral height and a group with at least one pathologically degraded vertebra. Individuals with osteoporosis according to the WHO-definition showed a higher prevalence of vertebral deformities. No significant loss of cortical density was observed in these people.


    • 1 September 1997
      • Vol. 7  (5) , 264-9

    [Development of a CT data-based score for prediction of fracture risk in osteoporosis].

    by R Andresen, S Radmer, D Banzer

    It should be examined how far BMD semiquantitative (profile analysis) and qualitative datas (architecture of spongy bone, age of patient) can be combined in one score in order to improve the assessment of fracture risk. SE-QCT was performed in 220 patients with a mean age of 55.8 (33-84) years from whom conventional X-ray images of the thoracic and lumbar spine were available. In the axial scans spongiosa architecture was classified and a density profile analysis was carried out. This was followed by gradation of BMD values, different types of spongiosa architecture, profile analysis and age of patient to a numerical score. This was compared to the number of fractures, whereby the patients were separated into three groups: group I = no fracture, group II = one fracture, group III = more than one fracture. The BMD values, types of spongiosa architecture, semiquantitative profile analysis can be significantly assigned to the groups I and II (p < 0.02), groups I and III (p < 0.001), and the groups II and III (p < 0.05). By combining BMD values, architecture of spongy bone, density profile analysis, and age of patients without fracture, scale 8-12 = patients with or without fracture, scale 13-16 = patients with at least one fracture [corrected].