G Lefevre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
G Lefevre has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
J Etienne
5 shared publications- Rémy Couderc
Service de biochimie, hôpital Tenon, Paris
4 shared publications A Duvallet
1 shared publicationB Viron
1 shared publicationC Cohen
1 shared publicationD Boutolleau
Service de biochimie, hôpital Tenon, Paris
1 shared publication
Latest Publications
- 1 December 2001
- Vol. 41 (4) , 513-20
Oxidative stress in hemodialyzed patients during exhausting exercise.
This study was designed to study the effect of an exhausting exercise test on plasma lipid peroxidation marker (malondialdehyde, MDA) and on vitamin E levels in hemodialyzed patients (HD) compared to healthy control subjects (HC). Eight sedentary chronically HD, (39.0+/-10.8 years) and eight sedentary HC (38.4+/-12.4 years) were studied. Before exercise, the activity of scavenger enzymes [plasma and erythrocyte glutathione peroxidase (GPX), and erythrocyte superoxide dismutase (SOD)] was determined. All subjects performed a symptom-limited exercise test; respiratory gas exchanges were collected on-line and blood was sampled five min before exercise, at exhaustion and after 30 min of recovery. At rest, the activity of plasma and erythrocyte GPX and erythrocyte SOD was significantly lower in HD than in HC. Exercise provoked an increase of plasma MDA concentration after recovery in HD patients, whereas our HC group show a decrease in MDA plasma level immediately after exercise, returning to the rest values during recovery. Exercise induced no change of vitamin E concentration in HD whereas in HC it increased during recovery. Our results indicate that: 1) at rest: although hemodialyzed patients showed lower scavenger enzymes activity than HC subjects, there was no difference in MDA plasma level between groups; 2) there is some evidence that physical exercise contribute to oxidative stress during recovery in HD patients, and 3) exercise induced an increase in plasma vitamin E concentration in healthy subjects.
- 1 December 2001
- Vol. 41 (4) , 513-20
Oxidative stress in hemodialyzed patients during exhausting exercise.
This study was designed to study the effect of an exhausting exercise test on plasma lipid peroxidation marker (malondialdehyde, MDA) and on vitamin E levels in hemodialyzed patients (HD) compared to healthy control subjects (HC). Eight sedentary chronically HD, (39.0+/-10.8 years) and eight sedentary HC (38.4+/-12.4 years) were studied. Before exercise, the activity of scavenger enzymes [plasma and erythrocyte glutathione peroxidase (GPX), and erythrocyte superoxide dismutase (SOD)] was determined. All subjects performed a symptom-limited exercise test; respiratory gas exchanges were collected on-line and blood was sampled five min before exercise, at exhaustion and after 30 min of recovery. At rest, the activity of plasma and erythrocyte GPX and erythrocyte SOD was significantly lower in HD than in HC. Exercise provoked an increase of plasma MDA concentration after recovery in HD patients, whereas our HC group show a decrease in MDA plasma level immediately after exercise, returning to the rest values during recovery. Exercise induced no change of vitamin E concentration in HD whereas in HC it increased during recovery. Our results indicate that: 1) at rest: although hemodialyzed patients showed lower scavenger enzymes activity than HC subjects, there was no difference in MDA plasma level between groups; 2) there is some evidence that physical exercise contribute to oxidative stress during recovery in HD patients, and 3) exercise induced an increase in plasma vitamin E concentration in healthy subjects.
- 1 September 2000
- Vol. 54 (3) , 210-7
Lp(a) is increased in hemodialysis patients according to the type of dialysis membrane: a 2-year follow-up study.
Patients with chronic renal failure treated by hemodialysis develop lipoprotein abnormalities that may contribute to their increased risk ofatherosclerosis. This study shows lipid parameter follow-up procedure according to the type of dialysis membrane in an unselected population of 33 hemodialysis patients. The study included 33 patients with end-stage renal disease and 110 healthy blood bank donors of Tenon Hospital. Cholesterol and triglycerides were determined by enzymatic methods, apoA-I, apoB by immunoturbidimetry and Lp(a) by immunonephelemetry. Apo(a) phenotyping was performed by agarose gel electrophoresis followed by immunoblotting. Patients and controls subjects were estimated by Student's t- and chi2-tests. Patients dialyzed with low-flux membranes had Lp(a) concentrations higher than patients dialyzed with high-flux membranes. Patients dialyzed with polyacrylonitrile membranes (AN 69) had an apoA-I concentration significantly lower than patients dialyzed with hemophane or polysulfone membranes. We also confirmed some of the lipid abnormalities and high Lp(a) concentrations in ESRD patients. These results may contribute to a more rational choice of the dialysis membrane in hemodialysis patients.
- 1 September 2000
- Vol. 54 (3) , 210-7
Lp(a) is increased in hemodialysis patients according to the type of dialysis membrane: a 2-year follow-up study.
Patients with chronic renal failure treated by hemodialysis develop lipoprotein abnormalities that may contribute to their increased risk ofatherosclerosis. This study shows lipid parameter follow-up procedure according to the type of dialysis membrane in an unselected population of 33 hemodialysis patients. The study included 33 patients with end-stage renal disease and 110 healthy blood bank donors of Tenon Hospital. Cholesterol and triglycerides were determined by enzymatic methods, apoA-I, apoB by immunoturbidimetry and Lp(a) by immunonephelemetry. Apo(a) phenotyping was performed by agarose gel electrophoresis followed by immunoblotting. Patients and controls subjects were estimated by Student's t- and chi2-tests. Patients dialyzed with low-flux membranes had Lp(a) concentrations higher than patients dialyzed with high-flux membranes. Patients dialyzed with polyacrylonitrile membranes (AN 69) had an apoA-I concentration significantly lower than patients dialyzed with hemophane or polysulfone membranes. We also confirmed some of the lipid abnormalities and high Lp(a) concentrations in ESRD patients. These results may contribute to a more rational choice of the dialysis membrane in hemodialysis patients.
- 1 September 1999
- Vol. 25 (4) , 350-5
[Evaluation of the quality of blood glucose meters using the HemoCue B glucose system].
Analytical evaluation three models of blood glucose meters (Glucometer IV (Bayer), Glucotrend (Roche Diagnostics) and One touch (Life Scan, Johnson & Johnson)) were compared within a central laboratory to an analyzer (Hitachi 747, Boehringer-Mannheim, Grenoble, France) and to a photometric device (HemoCue B-glucose). Each glucose meters met the criteria of within-run precision defined by the Association Française d'Etudes du Diabète et des Maladies Métaboliques (ALFEDIAM). Furthermore, HemoCue B-glucose met criteria defined by the French Society of Biological Chemistry (SFBC). In the study realized within laboratory, 28 to 66% of glucose tests realized with meters differed by more than 10% from plasma values and 43% of glucose assays realized with different meters differed by more than 10% from HemoCue B-glucose value. Within clinical departments, 46 glucose meters from 5 different models were evaluated. Answers to a questionnaire stored in HemoCue B-glucose underlined the weak development of glucose meters quality assurance. Within clinical departments, 65% of glucose values realized with meters differed by more than 10% from reference values. Development in clinical departments of glucose meters quality assurance programs can be monitored by HemoCue B-glucose, and must allowed improvement of glucose meter quality.
- 1 September 1999
- Vol. 25 (4) , 350-5
[Evaluation of the quality of blood glucose meters using the HemoCue B glucose system].
Analytical evaluation three models of blood glucose meters (Glucometer IV (Bayer), Glucotrend (Roche Diagnostics) and One touch (Life Scan, Johnson & Johnson)) were compared within a central laboratory to an analyzer (Hitachi 747, Boehringer-Mannheim, Grenoble, France) and to a photometric device (HemoCue B-glucose). Each glucose meters met the criteria of within-run precision defined by the Association Française d'Etudes du Diabète et des Maladies Métaboliques (ALFEDIAM). Furthermore, HemoCue B-glucose met criteria defined by the French Society of Biological Chemistry (SFBC). In the study realized within laboratory, 28 to 66% of glucose tests realized with meters differed by more than 10% from plasma values and 43% of glucose assays realized with different meters differed by more than 10% from HemoCue B-glucose value. Within clinical departments, 46 glucose meters from 5 different models were evaluated. Answers to a questionnaire stored in HemoCue B-glucose underlined the weak development of glucose meters quality assurance. Within clinical departments, 65% of glucose values realized with meters differed by more than 10% from reference values. Development in clinical departments of glucose meters quality assurance programs can be monitored by HemoCue B-glucose, and must allowed improvement of glucose meter quality.
- 21 March 1998
- Vol. 55 (6) , 592-6
[Determination of glutathione with the GSH-400 method: value of derivative spectrophotometry].
The GSH-400 method (Oxis International SA) performed in acid supernatant, provides an assay of reduced glutathione (L-gamma-glutamyl-L-cysteinylglycine) (GSH) in biological samples by a two step chemical reaction followed by a spectrophotometric detection. We improved the analytical performances of the assay by using derivative spectrophotometry (delta). The second order derivative (delta 2) spectrophotometry gave identical signals with either a GSH standard solution or a erythrocyte lysate containing the same amount of GSH, whereas the corresponding absorbances (Abs.) were different. The linearity range of the method was 20 to 2,000 mumol/l. Detection limit (DL) was not modified with derivative spectrophotometry (DL Abs. = 7 mumol/l; DL delta 2 = 12 mumol/l). The GSH-400 method was not suitable for plasma GSH determination. Erythrocyte GSH concentrations (M +/- SD) in 23 healthy subjects (8 men, 15 women, median age 36) obtained with absorbance measurements (2.66 +/- 0.60 mmol/l) were significantly higher than those obtained with delta 2 (2.30 +/- 0.41 mmol/l) (p < 0.001). Erythrocyte lysate storage at -20 degrees C did not lead to satisfactory conservation (65% decrease of the GSH concentration in erythrocytes after 15 days freezing). The derivative spectrophotometric detection improved analytical performances of GSH-400 method, when compared to the absorbance measurement at 400 nm.
- 21 March 1998
- Vol. 55 (6) , 592-6
[Determination of glutathione with the GSH-400 method: value of derivative spectrophotometry].
The GSH-400 method (Oxis International SA) performed in acid supernatant, provides an assay of reduced glutathione (L-gamma-glutamyl-L-cysteinylglycine) (GSH) in biological samples by a two step chemical reaction followed by a spectrophotometric detection. We improved the analytical performances of the assay by using derivative spectrophotometry (delta). The second order derivative (delta 2) spectrophotometry gave identical signals with either a GSH standard solution or a erythrocyte lysate containing the same amount of GSH, whereas the corresponding absorbances (Abs.) were different. The linearity range of the method was 20 to 2,000 mumol/l. Detection limit (DL) was not modified with derivative spectrophotometry (DL Abs. = 7 mumol/l; DL delta 2 = 12 mumol/l). The GSH-400 method was not suitable for plasma GSH determination. Erythrocyte GSH concentrations (M +/- SD) in 23 healthy subjects (8 men, 15 women, median age 36) obtained with absorbance measurements (2.66 +/- 0.60 mmol/l) were significantly higher than those obtained with delta 2 (2.30 +/- 0.41 mmol/l) (p < 0.001). Erythrocyte lysate storage at -20 degrees C did not lead to satisfactory conservation (65% decrease of the GSH concentration in erythrocytes after 15 days freezing). The derivative spectrophotometric detection improved analytical performances of GSH-400 method, when compared to the absorbance measurement at 400 nm.
- 5 November 1997
- Vol. 55 (5) , 443-50
[Pre-eclampsia and oxygenated free radicals].
Preeclampsia, clinically defined by arterial hypertension, oedema and proteinuria is a frequently occurred complication of pregnancy. This disease seems to be linked to oxidative stress within placenta. The local accumulation of lipid peroxides, resulting from free radicals production increase altered prostacyclin/thromboxane synthesis. Increased production of lipid peroxides, thromboxane and/or cytokines triggered vascular and organic dysfunctions observed in preeclampsia. Changes in lipoprotein metabolism, namely increase in plasma very low density lipoproteins concentrations (VLDL) and oxidized low density lipoproteins (LDL) concentrations could participate to endothelial dysfunctions observed during preeclampsia.
- 5 November 1997
- Vol. 55 (5) , 443-50
[Pre-eclampsia and oxygenated free radicals].
Preeclampsia, clinically defined by arterial hypertension, oedema and proteinuria is a frequently occurred complication of pregnancy. This disease seems to be linked to oxidative stress within placenta. The local accumulation of lipid peroxides, resulting from free radicals production increase altered prostacyclin/thromboxane synthesis. Increased production of lipid peroxides, thromboxane and/or cytokines triggered vascular and organic dysfunctions observed in preeclampsia. Changes in lipoprotein metabolism, namely increase in plasma very low density lipoproteins concentrations (VLDL) and oxidized low density lipoproteins (LDL) concentrations could participate to endothelial dysfunctions observed during preeclampsia.
- 1 July 1997
- Vol. 55 (4) , 343-7
[Evaluation and control of quality of bedside blood glucose analyzers in clinical services].
- 1 July 1997
- Vol. 55 (4) , 343-7
[Evaluation and control of quality of bedside blood glucose analyzers in clinical services].