RCRémy Couderc

Rémy Couderc

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rémy Couderc has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 31 July 2002
      • Vol. 60  (4) , 421-8

    [Comparison of plasma total homocysteine determinations in 9 French hospital laboratories by using 6 different methods].

    by V Ducros, M Candito, E Caussé, R Couderc, K Demuth, M E Diop, J Drai, M F Gerhardt, M Quillard, M H Read, et al.

    A lot of methods are now available for total plasma homocysteine (tHcy) determination. Commercial kits using immunoassay, easier to use, begin to supplant in-house laboratory methods. Our aim is to evaluate the interchangeability of tHcy measurements in 9 French hospital laboratories. Six different method types were used: 2 gas chromatography-mass spectrometry (GC-MS), 2 HPLC with fluorescence detection subdivided in one in-house method and one commercial kit (Bio-Rad ), 3 fluorescence polarization immunoassays (FPIA), 1 enzyme immunoassay, 1 amino acid analyser, 1 capillary electrophoresis coupled with laser-induced fluorescence detection (EC-LIF). Each laboratory analysed 41 patient's plasma samples in which 8 samples contained added homocystine. Results were analysed for imprecision, recovery, and methodological differences. The mean among-laboratory imprecision (CV) ranged from 12.5 to 18% in function of plasma sample type and was identical to the mean among-method variation. In terms of recovery, we obtained underestimated results with immunoassays. The bias relative to the GC-MS method was less than 12.5% except for two laboratories, one using FPIA assay and the other EC-LIF. In conclusion, the interchangeability of tHcy results between laboratories is not satisfactory and does not allow us to evaluate cardiovascular risk linked to moderate increases of tHcy.

    • 1 December 2001
      • Vol. 41  (4) , 513-20

    Oxidative stress in hemodialyzed patients during exhausting exercise.

    by L Jiménez, G Lefèvre, R Richard, R Couderc, M Saint George, A Duvallet, M Rieu

    This study was designed to study the effect of an exhausting exercise test on plasma lipid peroxidation marker (malondialdehyde, MDA) and on vitamin E levels in hemodialyzed patients (HD) compared to healthy control subjects (HC). Eight sedentary chronically HD, (39.0+/-10.8 years) and eight sedentary HC (38.4+/-12.4 years) were studied. Before exercise, the activity of scavenger enzymes [plasma and erythrocyte glutathione peroxidase (GPX), and erythrocyte superoxide dismutase (SOD)] was determined. All subjects performed a symptom-limited exercise test; respiratory gas exchanges were collected on-line and blood was sampled five min before exercise, at exhaustion and after 30 min of recovery. At rest, the activity of plasma and erythrocyte GPX and erythrocyte SOD was significantly lower in HD than in HC. Exercise provoked an increase of plasma MDA concentration after recovery in HD patients, whereas our HC group show a decrease in MDA plasma level immediately after exercise, returning to the rest values during recovery. Exercise induced no change of vitamin E concentration in HD whereas in HC it increased during recovery. Our results indicate that: 1) at rest: although hemodialyzed patients showed lower scavenger enzymes activity than HC subjects, there was no difference in MDA plasma level between groups; 2) there is some evidence that physical exercise contribute to oxidative stress during recovery in HD patients, and 3) exercise induced an increase in plasma vitamin E concentration in healthy subjects.


    • 15 February 2001
      • Vol. 59  (1) , 33-9

    [Plasma homocysteine measurement: a study of pre-analytical variation factors for conditions for total plasma homocysteine concentration].

    by V Ducros, M Candito, E Caussé, R Couderc, K Demuth, M E Diop, J Drai, A M Gachon, I Garcia, M F Gerhardt, et al.

    An increase in homocysteine, a sulphur amino acid, is nowdays considered as a risk factor for cardiovascular diseases, and is independent of other risk factors. Reference range for total plasma homocysteine level in adults is usually 5-15 mmol/l. Hyperhomocysteinemia is defined as a fasting total plasma homocysteine level > 15 mmol/l. There may be also graded increased risks for subjects with homocysteinemia from 10 to 15 mmol/l. However, no threshold has been defined, partly because of the lack of standardization in pre-analytical and analytical steps. The aim of the present work was to evaluate three pre-analytical parameters on plasma homocysteine levels: i) the influence of three anticoagulants (EDTA, sodium citrate and lithium heparin); ii) the delay period of blood sample on ice before centrifugation; and iii) the advantages of strong acidic citrate at room temperature. The mean concentrations of total plasma homocysteine were different in function of the anticoagulant. These differences (EDTA minus lithium heparin or EDTA minus sodium citrate) were less than 10% however the used methods and could explain the good correlation between the results. However we recommend to keep the anticoagulant constant in the same study. When EDTA blood samples were immediately put on crushed ice, the maximum delay period before centrifugation could reach 4 hours. If ice is unavailable, strong acidic citrate at room temperature is a good alternative until for 4 hours.


    • 1 September 2000
      • Vol. 54  (3) , 210-7

    Lp(a) is increased in hemodialysis patients according to the type of dialysis membrane: a 2-year follow-up study.

    by M E Diop, B Viron, S Bailleul, G Lefevre, H Fessi, J Maury, J Etienne, R Couderc

    Patients with chronic renal failure treated by hemodialysis develop lipoprotein abnormalities that may contribute to their increased risk ofatherosclerosis. This study shows lipid parameter follow-up procedure according to the type of dialysis membrane in an unselected population of 33 hemodialysis patients. The study included 33 patients with end-stage renal disease and 110 healthy blood bank donors of Tenon Hospital. Cholesterol and triglycerides were determined by enzymatic methods, apoA-I, apoB by immunoturbidimetry and Lp(a) by immunonephelemetry. Apo(a) phenotyping was performed by agarose gel electrophoresis followed by immunoblotting. Patients and controls subjects were estimated by Student's t- and chi2-tests. Patients dialyzed with low-flux membranes had Lp(a) concentrations higher than patients dialyzed with high-flux membranes. Patients dialyzed with polyacrylonitrile membranes (AN 69) had an apoA-I concentration significantly lower than patients dialyzed with hemophane or polysulfone membranes. We also confirmed some of the lipid abnormalities and high Lp(a) concentrations in ESRD patients. These results may contribute to a more rational choice of the dialysis membrane in hemodialysis patients.


    • 1 September 1999
      • Vol. 25  (4) , 350-5

    [Evaluation of the quality of blood glucose meters using the HemoCue B glucose system].

    by G Lefèvre, S Girardot-Dubois, G Chevallier, C Cohen, R Couderc, J Etienne

    Analytical evaluation three models of blood glucose meters (Glucometer IV (Bayer), Glucotrend (Roche Diagnostics) and One touch (Life Scan, Johnson & Johnson)) were compared within a central laboratory to an analyzer (Hitachi 747, Boehringer-Mannheim, Grenoble, France) and to a photometric device (HemoCue B-glucose). Each glucose meters met the criteria of within-run precision defined by the Association Française d'Etudes du Diabète et des Maladies Métaboliques (ALFEDIAM). Furthermore, HemoCue B-glucose met criteria defined by the French Society of Biological Chemistry (SFBC). In the study realized within laboratory, 28 to 66% of glucose tests realized with meters differed by more than 10% from plasma values and 43% of glucose assays realized with different meters differed by more than 10% from HemoCue B-glucose value. Within clinical departments, 46 glucose meters from 5 different models were evaluated. Answers to a questionnaire stored in HemoCue B-glucose underlined the weak development of glucose meters quality assurance. Within clinical departments, 65% of glucose values realized with meters differed by more than 10% from reference values. Development in clinical departments of glucose meters quality assurance programs can be monitored by HemoCue B-glucose, and must allowed improvement of glucose meter quality.


    • 16 December 1998
      • Vol. 56  (6) , 651-9

    [Apolipoprotein E and its alleles in healthy subjects and in atherosclerosis].

    by R Couderc, S Bailleul

    Apolipoprotein E (apo E) plays a central role in lipoprotein metabolism as a ligand for LDL-, VLDL- and remnant receptors. It is mainly synthesized by hepatocytes and also by monocytes-macrophages. There are three common codominant isoforms E2, E3 and E4. Apo E2 binds defectively to LDL- and to remnant-receptors. Apo E alleles frequency varies from population to population around the world. In Europe, E4 allele frequency increases from south to north along the cardiovascular disease frequency gradient. On the other hand, the association between E2 allele and these diseases remains to be proved except for type III hyperlipoproteinemia. Apo E4 role in atherosclerosis could be explained, at least in part, by its high solubility in apo B lipoproteins. The average cholesterolemia of E4/E3 subjects is higher than E3/E3 subjects and E3/E3 subjects' cholesterolemia is higher than in E3/E2 subjects, probably because of a faster uptake of chylomicrons and VLDL remnants in E4/E3 subjects. The E4 allele also seems to play a role not only in diet response in combination with other genetic factors such as the Eco RI polymorphism of apo B but also in hypolipemic treatment. Apo E plays also a role in triglyceridemia control in association with other genetic and environmental factors such as lipoprotein lipase, apo B, LDL receptor and diet. Models of apo E knockout mice suggest a protective effect of monocyte-macrophageapo E in the vessel wall and HDL-apo E probably induces a high cholesterol efflux from macrophages. This effect counteracts the proatherogenic effect of VLDL- and IDL-apo E. The balance between these effects could be influenced by apo E phenotype.


  • Effects of postprandial hyperlipemia on the vitamin E content of lipoproteins

    by Rémy Couderc, Jacqueline Peynet, Michèle Cambillaud, Frank Tallet, Claudine Cosson, Guillaume Lefèvre, Véronique Atger


  • Open Access

    A Simple Electrophoretic Method for Phenotyping Apo(a): Phenotype Frequency in Healthy Subjects from Paris, France

    by R Couderc, K Peoc’h, K Valenti, M-E Diop, S Bailleul, L KiénOu, F FerrièrE, J Etienne

    Lipoprotein(a) [Lp(a)] is an LDL-like particle whose apo B100 is disulfide-linked to an apolipoprotein A [apo(a)]. Apo(a) is a glycoprotein containing 23% carbohydrate by weight (1). Apo(a) possesses a high degree of polymorphism because of a variable number (11–52) of the repetitive structural unit called “kringle” IV (K IV; Mr ≈ 17 kDa), which leads to a wide range of molecular weights, from almost 200 kDa to 800 kDa (2). The apo(a) K IV shares a strong sequence homology with plasminogen K IV, and apo(a) has been shown to inhibit fibrinolysis in vitro. (3)


    • 1 July 1997
      • Vol. 55  (4) , 343-7

    [Evaluation and control of quality of bedside blood glucose analyzers in clinical services].

    by R Couderc, G Lefèvre, N Cachin, L Sebban, J Etienne

    • 1 April 1995
      • Vol. 151  (4) , 231-9

    [Isoform 4 of apolipoprotein E and Alzheimer disease. Specificity and clinical study].

    by F Mahieux, R Couderc, A Moulignier, S Bailleul, N Podrabinek, J Laudet

    We studied apolipoprotein E (apoE) phenotype in 113 patients with possible and probable Alzheimer's disease (AD), 49 patients with Parkinson's disease (including 11 patients with dementia) and 23 patients with mixed and vascular dementia. Normal controls were 498 young, healthy blood donors previously recorded. All patients were assayed for blood lipid parameters. All AD patients underwent a neuropsychological evaluation (including a mini-mental status and 5 subtests of Cole and Dastoor hierarchic dementia scale) and a detailed interrogation of them and their caregivers about their familial and personal medical history. The recorded data included age at onset, clinical subtype (i.e. amnesic or aphaso-apraxic), occurrence of fits, cases of probable dementia in relatives, and ages of their parents at death. There was a significant association between the fourth isoform of apoE and AD, as in previous works. We did not found such an association for PD patients (even with dementia) nor mixed and vascular demented patients. We failed to find any association between any clinical characteristic of the patients and the biological subgroups defined by the number of epsilon 4 alleles, except with regard for the age of onset. Surprisingly, the mothers of epsilon 4 bearers had a significantly longer life than mothers of other patients. We failed to found any significant difference of apoE2 isoform frequency between AD patients and controls. AD patients had higher levels of cholesterol and apoAl than did MP and mixed and vascular demented patients. ApoAl level is known to constitute a protective factor against coronary heart disease, which is usually increased by the presence of apoE-epsilon 4.(ABSTRACT TRUNCATED AT 250 WORDS)