Flávio Domingues das Neves
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Flávio Domingues das Neves has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Karla Zancopé
Federal University of Uberlândia
4 shared publications - Paulo Cézar Simamoto Júnior
Universidade Federal de Uberlândia, Brasil
3 shared publications Frederick Khalil Karam
2 shared publications- João Paulo da Silva-Neto
Universidade Estadual da Paraiba
2 shared publications Letícia Resende Davi
2 shared publicationsLucas Zago Naves
2 shared publications
Latest Publications
- 1 January 2018
- Published by Editora e Livrarias Plena Ltd. in Prosthesis and Esthetics in Science
- Vol. 7 (28) , 55-60
Avaliação da higiene oral em prótese fixa múltipla sobre implantes expostos após necrose óssea – relato de caso
Avaliação da higiene oral em prótese fixa múltipla sobre implantes expostos após necrose óssea – relato de caso - editoraplena.com.br
- 1 January 2018
- Published by Editora e Livrarias Plena Ltd. in Prosthesis and Esthetics in Science
- Vol. 7 (28) , 55-60
Avaliação da higiene oral em prótese fixa múltipla sobre implantes expostos após necrose óssea – relato de caso
Avaliação da higiene oral em prótese fixa múltipla sobre implantes expostos após necrose óssea – relato de caso - editoraplena.com.br
- Open Access
- 15 December 2017
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 16, 1-9
Comparative analysis of Optical Microscopy, Scanning Electron Microscopy, and Micro-Computed Tomography on measurements
Microscopic measurements are widely used in scientific research and the correct equipment to realize these evaluations could be critical to determine study results. Regarding microscopic measurements, three of the most used methods are: Optical Microscopy (OM), Scanning Electron Microscopy (SEM), and Micro-computed Tomography (MCT). It is important to select the best method for assessing diverse parameters, considering operational characteristics of the method, the equipment efficiency, and the machinery cost. Therefore, the main objective of this study was to define which is the most useful measurement method for assessing magnitudes below 0.4 mm. Ten dental implants, with known dimensions as defined by the manufacturer were randomly distributed. Two blinded observers assessed the distance between the second and the third screw vortex of the implants using three suggested methods. The true distance was defined to be 0.5 mm. The assessed distances were: 0.597±0.007mm for OM, 0.578±0.017mm for SEM, and 0.613±0.006mm for MCT. The assessed distances were significantly different when the methods were compared (P>0.01). All measurements were into the CAD tolerances. It was possible to conclude that linear measurements between 595 and 605 μm could be performed by any of the described technologies.
- 15 December 2017
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 16, 1-9
Open AccessComparative analysis of Optical Microscopy, Scanning Electron Microscopy, and Micro-Computed Tomography on measurements
Microscopic measurements are widely used in scientific research and the correct equipment to realize these evaluations could be critical to determine study results. Regarding microscopic measurements, three of the most used methods are: Optical Microscopy (OM), Scanning Electron Microscopy (SEM), and Micro-computed Tomography (MCT). It is important to select the best method for assessing diverse parameters, considering operational characteristics of the method, the equipment efficiency, and the machinery cost. Therefore, the main objective of this study was to define which is the most useful measurement method for assessing magnitudes below 0.4 mm. Ten dental implants, with known dimensions as defined by the manufacturer were randomly distributed. Two blinded observers assessed the distance between the second and the third screw vortex of the implants using three suggested methods. The true distance was defined to be 0.5 mm. The assessed distances were: 0.597±0.007mm for OM, 0.578±0.017mm for SEM, and 0.613±0.006mm for MCT. The assessed distances were significantly different when the methods were compared (P>0.01). All measurements were into the CAD tolerances. It was possible to conclude that linear measurements between 595 and 605 μm could be performed by any of the described technologies.
- 1 January 2017
- Published by Editora e Livrarias Plena Ltd. in Full Dentistry in Science
- Vol. 30 (8) , 22-26
Avaliação da eficiência antibacteriana de géis e pomadas utilizados no interior de implantes
- 1 January 2017
- Published by Editora e Livrarias Plena Ltd. in Full Dentistry in Science
- Vol. 30 (8) , 22-26
Avaliação da eficiência antibacteriana de géis e pomadas utilizados no interior de implantes
- 11 February 2016
- Published by Editora Napoleao Ltda ME in The International Journal of Oral and Maxillofacial Implants
- Vol. 1 (1) , 56
Técnica de Recuperação para Protocolo Novum Branemark: Reposição de Implante Perdido
- 11 February 2016
- Published by Editora Napoleao Ltda ME in The International Journal of Oral and Maxillofacial Implants
- Vol. 1 (1) , 56
Técnica de Recuperação para Protocolo Novum Branemark: Reposição de Implante Perdido
- 7 May 2015
- Vol. 63 (3) , 39-42
Microcomputed tomography marginal fit evaluation of computer-aided design/computer-aided manufacturing crowns with different methods of virtual model acquisition.
This in vitro study used microcomputed tomography to evaluate the marginal fit of crowns fabricated using a chairside computer-aided design/computer-aided manufacturing (CAD/CAM) system with different methods of virtual model acquisition. Crowns were fabricated to fit in a cast containing a single human premolar. Four methods of virtual model acquisition were used: Group 1 (control), digital impressioning of a typodont; Group 2, digital impressioning of a powdered typodont; Group 3, digital impressioning of a regular impression; and Group 4, digital impressioning of a master cast. Statistically significant differences were found between the marginal gap of Group 2 and the other groups (P < 0.05); no differences were found among Groups 1, 3, and 4. The results showed that crowns fabricated using the chairside CAD/CAM system exhibited significantly smaller vertical misfit when a thin layer of powder was applied over the typodont before digital impressioning.
- 7 May 2015
- Vol. 63 (3) , 39-42
Microcomputed tomography marginal fit evaluation of computer-aided design/computer-aided manufacturing crowns with different methods of virtual model acquisition.
This in vitro study used microcomputed tomography to evaluate the marginal fit of crowns fabricated using a chairside computer-aided design/computer-aided manufacturing (CAD/CAM) system with different methods of virtual model acquisition. Crowns were fabricated to fit in a cast containing a single human premolar. Four methods of virtual model acquisition were used: Group 1 (control), digital impressioning of a typodont; Group 2, digital impressioning of a powdered typodont; Group 3, digital impressioning of a regular impression; and Group 4, digital impressioning of a master cast. Statistically significant differences were found between the marginal gap of Group 2 and the other groups (P < 0.05); no differences were found among Groups 1, 3, and 4. The results showed that crowns fabricated using the chairside CAD/CAM system exhibited significantly smaller vertical misfit when a thin layer of powder was applied over the typodont before digital impressioning.
- 6 October 2014
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. Publish Ah (6) , 704-709
Photoelastic Stress Analysis of Mandibular Fixed Prostheses Supported by 3 Dental Implants
To observe the photoelastic stress patterns generated around implants in relation to variations in the diameter and total number of implants supporting fixed complete-arch mandibular frameworks. Three different implant configurations were analyzed (n = 3): 5 standard implants with diameters of 3.75 mm (C), 3 standard implants with diameters of 3.75 mm (3S), and 3 wide implants with diameters of 5.0 mm (3W). The samples were subjected to a vertical compressive load (1.33 kgf) applied at the end of the distal cantilever of the framework. The shear stresses were calculated around the implants, and the data were analyzed using one-way analysis of variance. The implants nearest to the loading showed higher stress values regardless of the group. The C group showed lower shear stress when compared with the other groups (P = 0.001). No significant difference was observed between the 3W and 3S groups (P = 0.785). A reduction in the number of implants, regardless of the implant diameter, showed higher stress concentration around the implants. Five-implant configuration showed lower stress concentration and seems to be more biomechanically predictable.
- 6 October 2014
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. Publish Ah (6) , 704-709
Photoelastic Stress Analysis of Mandibular Fixed Prostheses Supported by 3 Dental Implants
To observe the photoelastic stress patterns generated around implants in relation to variations in the diameter and total number of implants supporting fixed complete-arch mandibular frameworks. Three different implant configurations were analyzed (n = 3): 5 standard implants with diameters of 3.75 mm (C), 3 standard implants with diameters of 3.75 mm (3S), and 3 wide implants with diameters of 5.0 mm (3W). The samples were subjected to a vertical compressive load (1.33 kgf) applied at the end of the distal cantilever of the framework. The shear stresses were calculated around the implants, and the data were analyzed using one-way analysis of variance. The implants nearest to the loading showed higher stress values regardless of the group. The C group showed lower shear stress when compared with the other groups (P = 0.001). No significant difference was observed between the 3W and 3S groups (P = 0.785). A reduction in the number of implants, regardless of the implant diameter, showed higher stress concentration around the implants. Five-implant configuration showed lower stress concentration and seems to be more biomechanically predictable.
- Open Access
- 18 August 2014
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 28 (1) , 1-6
Immediate loading implants with mandibular overdenture: a 48-month prospective follow-up study
The aim of this prospective clinical study was to evaluate patient rehabilitation with two immediately loaded implants and bar-retained mandibular overdentures after 48 months of follow-up. Twenty patients were treated with two implants each; of these, 17 patients were re-evaluated for comparison. Gender, age, plaque index, gingival inflammation, keratinized mucosa, probing depth, bleeding, and implant loss data were recorded, and periapical radiographs were obtained for measurement of marginal bone loss. The results were statistically analyzed with one-way analysis of variance (ANOVA) followed by Student’s t-test and Pearson’s correlation test. To compare the data at baseline and after 48 months, a Wilcoxon Signed Rank Test was performed (α = 0.05). One implant failed (2.9%) during the first year and was replaced. A total of 35 implants were evaluated. Bone loss values were 0.52–2.89 mm (mean, 1.46 mm). Probing depth was 1.75–3.75 mm (mean, 2.22 mm). Correlations were found between bone loss and plaque index and between bone loss and gender, but bone loss did not correlate with gingival inflammation, keratinized mucosa, probing depth, or age. The overall survival rate of the implants was 97.1%. Based on these results, the use of two immediately loaded splinted interforaminal implants to retain an overdenture with a bar attachment is a clinically viable option with a high survival rate.
- 18 August 2014
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 28 (1) , 1-6
Open AccessImmediate loading implants with mandibular overdenture: a 48-month prospective follow-up study
The aim of this prospective clinical study was to evaluate patient rehabilitation with two immediately loaded implants and bar-retained mandibular overdentures after 48 months of follow-up. Twenty patients were treated with two implants each; of these, 17 patients were re-evaluated for comparison. Gender, age, plaque index, gingival inflammation, keratinized mucosa, probing depth, bleeding, and implant loss data were recorded, and periapical radiographs were obtained for measurement of marginal bone loss. The results were statistically analyzed with one-way analysis of variance (ANOVA) followed by Student’s t-test and Pearson’s correlation test. To compare the data at baseline and after 48 months, a Wilcoxon Signed Rank Test was performed (α = 0.05). One implant failed (2.9%) during the first year and was replaced. A total of 35 implants were evaluated. Bone loss values were 0.52–2.89 mm (mean, 1.46 mm). Probing depth was 1.75–3.75 mm (mean, 2.22 mm). Correlations were found between bone loss and plaque index and between bone loss and gender, but bone loss did not correlate with gingival inflammation, keratinized mucosa, probing depth, or age. The overall survival rate of the implants was 97.1%. Based on these results, the use of two immediately loaded splinted interforaminal implants to retain an overdenture with a bar attachment is a clinically viable option with a high survival rate.
- 1 March 2014
- Vol. 33 (3) , 108, 110-1
Nonconventional rehabilitation for anterior single tooth loss: clinical follow-up at 12 years.
- 1 March 2014
- Vol. 33 (3) , 108, 110-1
Nonconventional rehabilitation for anterior single tooth loss: clinical follow-up at 12 years.
- 12 October 2012
- Vol. 27 (5) , e86-9
Retrieval technique for the Branemark Novum protocol: replacement of a lost implant.
In the past, the Branemark Novum protocol for the immediate functional loading of a mandibular fixed implant supported prosthesis provided an effective alternative for select patients. However, the manufacturer has discontinued this design, and only a few selected prosthetic-related replacement components are currently available. This clinical report presents the loss of an implant associated with a discontinued system. To take advantage of all of the preexisting components, it proposes a rescue procedure that allows continuous use of the original fixed restoration during the restoration of the tripod support at the implant level.
- 12 October 2012
- Vol. 27 (5) , e86-9
Retrieval technique for the Branemark Novum protocol: replacement of a lost implant.
In the past, the Branemark Novum protocol for the immediate functional loading of a mandibular fixed implant supported prosthesis provided an effective alternative for select patients. However, the manufacturer has discontinued this design, and only a few selected prosthetic-related replacement components are currently available. This clinical report presents the loss of an implant associated with a discontinued system. To take advantage of all of the preexisting components, it proposes a rescue procedure that allows continuous use of the original fixed restoration during the restoration of the tripod support at the implant level.