Karla Zancopé
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Karla Zancopé has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Flávio Domingues das Neves
Federal University of Uberlândia
18 shared publications - Gustavo Mendonça
Virginia Commonwealth University, USA
9 shared publications - Carlos José Soares
Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Brazil
8 shared publications Flávio Domingues das Neves
Department of Occlusion, Fixed Prosthodontics, and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
6 shared publicationsCaio César Dias Resende
PhD student, Department of Occlusion, Fixed Prosthesis and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
4 shared publications- Flávio Domingues das Neves
Federal University of Uberlândia
4 shared publications
Latest Publications
- Open Access
- 20 April 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (8) , 1527-1533
Load‐To‐Failure of Cantilevered Provisional Implant‐Supported Prostheses: Conventional Versus 3D ‐Printed Resins
Objective: Cantilever extensions in full‐arch implant‐supported provisional prostheses represent a clinical challenge frequently associated with biomechanical complications. This study aimed to evaluate the load‐to‐failure and deflection of acrylic and 3D‐printed resins used in the cantilever region of implant‐supported provisional prostheses fabricated over mini‐abutment cylinders. Materials and Methods: Forty standardized specimens with 15‐mm cantilever were allocated into four groups ( n = 10): auto‐polymerized resin (RA), high‐impact thermo‐polymerized resin (RD), 3D‐printed resin (RI) and thermo‐polymerized denture resin reinforced with metallic infrastructure (RT, control). Load‐to‐failure and displacement were measured using a universal testing machine and deflectometer (Instron). Data were analyzed using one‐way ANOVA and Tukey's post hoc test ( α = 0.05). Results: Significant differences were observed among all materials ( p < 0.001). The control group showed the highest load‐to‐failure (553 N), followed by RI (506 N), RD (440 N), and RA (396 N). The 3D‐printed resin group exhibited the lowest deflection value (2.33 mm) and the high‐impact resin the greatest (5.07 mm). Conclusion: Material selection critically influences the biomechanical stability of cantilevered provisional implant prostheses. The high‐impact resin showed higher degree of flexibility; and the RI group greater load bearing capacity, time efficiency, and predictability, therefore both are suitable alternatives for full‐arch temporary implant‐supported rehabilitations.
- 20 April 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (8) , 1527-1533
Open AccessLoad‐To‐Failure of Cantilevered Provisional Implant‐Supported Prostheses: Conventional Versus 3D ‐Printed Resins
Objective: Cantilever extensions in full‐arch implant‐supported provisional prostheses represent a clinical challenge frequently associated with biomechanical complications. This study aimed to evaluate the load‐to‐failure and deflection of acrylic and 3D‐printed resins used in the cantilever region of implant‐supported provisional prostheses fabricated over mini‐abutment cylinders. Materials and Methods: Forty standardized specimens with 15‐mm cantilever were allocated into four groups ( n = 10): auto‐polymerized resin (RA), high‐impact thermo‐polymerized resin (RD), 3D‐printed resin (RI) and thermo‐polymerized denture resin reinforced with metallic infrastructure (RT, control). Load‐to‐failure and displacement were measured using a universal testing machine and deflectometer (Instron). Data were analyzed using one‐way ANOVA and Tukey's post hoc test ( α = 0.05). Results: Significant differences were observed among all materials ( p < 0.001). The control group showed the highest load‐to‐failure (553 N), followed by RI (506 N), RD (440 N), and RA (396 N). The 3D‐printed resin group exhibited the lowest deflection value (2.33 mm) and the high‐impact resin the greatest (5.07 mm). Conclusion: Material selection critically influences the biomechanical stability of cantilevered provisional implant prostheses. The high‐impact resin showed higher degree of flexibility; and the RI group greater load bearing capacity, time efficiency, and predictability, therefore both are suitable alternatives for full‐arch temporary implant‐supported rehabilitations.
- Open Access
- 28 January 2026
- Published by Universidade Estadual de Campinas in Brazilian Journal of Oral Sciences
- Vol. 25, e268394
Three-dimensional positioning analysis of dental implants in printed casts – in vitro study
The purpose of this in vitro study was to evaluate the three-dimensional positioning of dental implants in casts obtained using conventional and digital impressions. A printed typodont with three digital mini-abutment analogues (Neodent, Curitiba, Brazil) and a scan body for mini-abutments (EFF – Dental Components, São Paulo, Brazil) was scanned five times (n=5) with two different scanners (Omnicam, CEREC, Dentsply Sirona and TRIOS 3, 3Shape) Five stone casts were fabricated from conventional impressions of the primary cast and then scanned using a laboratory scanner. Dental implant angulation and displacement were calculated. One cobalt-chrome metal framework was fabricated over the primary cast and seated over each obtained cast, and the misfit was assessed using scanning electron microscopy (SEM) For precision and trueness, data distribution and variance equality were analyzed using the Shapiro-Wilk and Levene’s tests, respectively. Precision was assessed using one-way ANOVA; trueness was assessed using two-way ANOVA. Both analyses were followed by Tukey’s test (α=0.05).The buccal-lingual angle showed no statistically significant differences, and the mesio-distal angle also showed no significant differences between cast types, although worse results were found for the distal implant. Implant displacement showed better results (lower values) for stone casts in all directions (P=.001). The prosthetic interface region showed better outcomes compared to the bevel feature of the scan body in all directions (P=.001). SEM evaluation showed no statistically significant differences in vertical misfit when all implant prosthetic screws were tightened in all groups. Printed casts present greater variability in 3D positioning and misfit of dental implants compared to conventional casts.
- 28 January 2026
- Published by Universidade Estadual de Campinas in Brazilian Journal of Oral Sciences
- Vol. 25, e268394
Open AccessThree-dimensional positioning analysis of dental implants in printed casts – in vitro study
The purpose of this in vitro study was to evaluate the three-dimensional positioning of dental implants in casts obtained using conventional and digital impressions. A printed typodont with three digital mini-abutment analogues (Neodent, Curitiba, Brazil) and a scan body for mini-abutments (EFF – Dental Components, São Paulo, Brazil) was scanned five times (n=5) with two different scanners (Omnicam, CEREC, Dentsply Sirona and TRIOS 3, 3Shape) Five stone casts were fabricated from conventional impressions of the primary cast and then scanned using a laboratory scanner. Dental implant angulation and displacement were calculated. One cobalt-chrome metal framework was fabricated over the primary cast and seated over each obtained cast, and the misfit was assessed using scanning electron microscopy (SEM) For precision and trueness, data distribution and variance equality were analyzed using the Shapiro-Wilk and Levene’s tests, respectively. Precision was assessed using one-way ANOVA; trueness was assessed using two-way ANOVA. Both analyses were followed by Tukey’s test (α=0.05).The buccal-lingual angle showed no statistically significant differences, and the mesio-distal angle also showed no significant differences between cast types, although worse results were found for the distal implant. Implant displacement showed better results (lower values) for stone casts in all directions (P=.001). The prosthetic interface region showed better outcomes compared to the bevel feature of the scan body in all directions (P=.001). SEM evaluation showed no statistically significant differences in vertical misfit when all implant prosthetic screws were tightened in all groups. Printed casts present greater variability in 3D positioning and misfit of dental implants compared to conventional casts.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 37
Impact of material, number, and bevel alignment on scan body trueness
This study investigated the influence of material, number, and bevel alignment of intraoral scan bodies (ISBs) on the trueness of digital impressions. A mandibular typodont missing the left first and second premolars and first molar was used. ISBs for Mini Conical Abutments varied according to material (polyetheretherketone [PEEK] or Titanium), number (2 or 3), and bevel alignment (buccal-aligned, lingual-aligned, or misaligned). Each group was scanned once with a laboratory scanner to obtain the reference model and ten times with an intraoral scanner (N=10). STL files were aligned and compared using 3D overlay software to assess trueness. Statistical analysis was performed at a 5% significance level. Since assumptions of normality and homogeneity of variance were violated, a Generalized Linear Model (GLM) with 1,000 bootstrap resamples was applied. The dependent variable was discrepancy (µm), and the independent variables included material, number, and bevel alignment. Holm's post hoc test was used for pairwise comparisons, with effect sizes calculated using adjusted omega squared (ω²) for main effects and Cohen’s d for interactions. All factors significantly influenced trueness, with the strongest effect observed when variables interacted simultaneously. Titanium demonstrated superior performance compared with PEEK, although the effect size was small. Two ISBs showed lower mean discrepancy and variability than three, indicating a moderate effect. Regarding bevel alignment, buccal and misaligned orientations performed better than lingual alignment, which presented the least favorable outcomes. These findings indicate that the trueness of digital impressions is multifactorial, with material, number, and alignment of ISBs interacting to play a crucial role.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 37
Open AccessImpact of material, number, and bevel alignment on scan body trueness
This study investigated the influence of material, number, and bevel alignment of intraoral scan bodies (ISBs) on the trueness of digital impressions. A mandibular typodont missing the left first and second premolars and first molar was used. ISBs for Mini Conical Abutments varied according to material (polyetheretherketone [PEEK] or Titanium), number (2 or 3), and bevel alignment (buccal-aligned, lingual-aligned, or misaligned). Each group was scanned once with a laboratory scanner to obtain the reference model and ten times with an intraoral scanner (N=10). STL files were aligned and compared using 3D overlay software to assess trueness. Statistical analysis was performed at a 5% significance level. Since assumptions of normality and homogeneity of variance were violated, a Generalized Linear Model (GLM) with 1,000 bootstrap resamples was applied. The dependent variable was discrepancy (µm), and the independent variables included material, number, and bevel alignment. Holm's post hoc test was used for pairwise comparisons, with effect sizes calculated using adjusted omega squared (ω²) for main effects and Cohen’s d for interactions. All factors significantly influenced trueness, with the strongest effect observed when variables interacted simultaneously. Titanium demonstrated superior performance compared with PEEK, although the effect size was small. Two ISBs showed lower mean discrepancy and variability than three, indicating a moderate effect. Regarding bevel alignment, buccal and misaligned orientations performed better than lingual alignment, which presented the least favorable outcomes. These findings indicate that the trueness of digital impressions is multifactorial, with material, number, and alignment of ISBs interacting to play a crucial role.
- Open Access
- 23 June 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (6) , e0325068
Effect of autoclaving process on trueness and qualitative marginal fit of intraoral scan body manufactured from two materials: An in vitro study
Statement of the problem: It is not clear the effect of multiple autoclaving processes on the accuracy of scan bodies. Autoclaving dental disposables enables reuse, reducing the environmental impact of raw materials and waste. Purpose: This in vitro laboratory study evaluated the effect of the autoclaving process on the intraoral scan body (SB) manufactured from different materials (Titanium and PEEK), positioned at the implant and abutment levels. Methods: Two models, each with 10 implants, were created to evaluate scan body trueness made of two materials (Titanium and PEEK), and implant junction positioned at two levels (implant and abutment levels). Analyses were conducted at five distinct time points: T0 (control group with new SB), T1 (after one autoclaving cycle), T2 (10 cycles), T3 (50 cycles), and T4 (100 cycles). Forty SBs were divided into four groups (n = 10), fixed on the models according to the initial positioning, using the recommended torque, and scanned 10 times using an intraoral Sccaner (InEOS X5 scanner, Dentsply Sirona). The surface deviation was evaluated by .STL mesh overlay using an image software (Geomagic Control X software). Microscopic analyses of marginal adaptation were performed simultaneously with the digital analysis using an optical microscope (Mitutoyo™-500 Optical Microscope) with 40x magnification at four places (mesial, distal, buccal, and lingual). Statistical analysis was performed using statistical software (SPSS 29.0 software), with α = 0,05. Data were subjected to the Shapiro-Wilk normality test. To assess spatial variation after the cycles, Repeated Measures ANOVA with Bonferroni correction was used. For microscopic qualitative analysis, percentile was used to check the prevalence of clinically adapted and misfitting faces. Results: Statistically significant differences in mesh deformation were detected, with PEEK SB showing greater deformation compared to Titanium, especially at the abutment level, after 100 cycles (P < 0.01). Microscopic analysis revealed that 100% of the faces were classified as “Clinically Adapted” by the three calibrated evaluators (KAPPA > 0.08). Conclusions: Titanium scan bodies showed less surface deviation than PEEK but both remained below 50 µm. Internal-junction scan bodies were more affected than abutment-level ones. All scan bodies stayed within acceptable limits and viable after 100 autoclaving cycles.
- 23 June 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (6) , e0325068
Open AccessEffect of autoclaving process on trueness and qualitative marginal fit of intraoral scan body manufactured from two materials: An in vitro study
Statement of the problem: It is not clear the effect of multiple autoclaving processes on the accuracy of scan bodies. Autoclaving dental disposables enables reuse, reducing the environmental impact of raw materials and waste. Purpose: This in vitro laboratory study evaluated the effect of the autoclaving process on the intraoral scan body (SB) manufactured from different materials (Titanium and PEEK), positioned at the implant and abutment levels. Methods: Two models, each with 10 implants, were created to evaluate scan body trueness made of two materials (Titanium and PEEK), and implant junction positioned at two levels (implant and abutment levels). Analyses were conducted at five distinct time points: T0 (control group with new SB), T1 (after one autoclaving cycle), T2 (10 cycles), T3 (50 cycles), and T4 (100 cycles). Forty SBs were divided into four groups (n = 10), fixed on the models according to the initial positioning, using the recommended torque, and scanned 10 times using an intraoral Sccaner (InEOS X5 scanner, Dentsply Sirona). The surface deviation was evaluated by .STL mesh overlay using an image software (Geomagic Control X software). Microscopic analyses of marginal adaptation were performed simultaneously with the digital analysis using an optical microscope (Mitutoyo™-500 Optical Microscope) with 40x magnification at four places (mesial, distal, buccal, and lingual). Statistical analysis was performed using statistical software (SPSS 29.0 software), with α = 0,05. Data were subjected to the Shapiro-Wilk normality test. To assess spatial variation after the cycles, Repeated Measures ANOVA with Bonferroni correction was used. For microscopic qualitative analysis, percentile was used to check the prevalence of clinically adapted and misfitting faces. Results: Statistically significant differences in mesh deformation were detected, with PEEK SB showing greater deformation compared to Titanium, especially at the abutment level, after 100 cycles (P < 0.01). Microscopic analysis revealed that 100% of the faces were classified as “Clinically Adapted” by the three calibrated evaluators (KAPPA > 0.08). Conclusions: Titanium scan bodies showed less surface deviation than PEEK but both remained below 50 µm. Internal-junction scan bodies were more affected than abutment-level ones. All scan bodies stayed within acceptable limits and viable after 100 autoclaving cycles.
- Open Access
- 4 February 2025
- Published by Brazilian Journals in Revista Caribeña de Ciencias Sociales
- Vol. 14 (2) , e4455
Instalação de implante estreito (2.9mm) para reabilitação unitária em área de incisivo central inferior: relato de caso
Apesar das vantagens da instalação de implantes de diâmetro regular para reabilitações totais, parciais ou unitárias, em algumas situações seu uso está limitado. O implante Facility de 2.9mm de diâmetro é um implante com conexão protética puramente Morse, sem parafusos internos. O presente trabalho tem como objetivo o relato de um caso clínico com a utilização do implante Facility. Paciente de 21 anos, gênero masculino, apresentava agenesia do elemento 32. No exame clínico podia ser observado espaço para a instalação de implante de diâmetro estreito. O tratamento proposto foi instalação de implante 2.9mm de diâmetro (Facility, Curitiba, Brasil) cuja indicação é compatível com o caso apresentado. A instalação do implante foi feita de acordo com a sequência de brocas sugerida pelo fabricante. Foi instalado o implante de 14mm de comprimento, posicionado 1.5mm infra ósseo com um cicatrizador de 2.5mm de altura. Uma prótese provisória adesiva direta foi instalada ao final do procedimento cirúrgico. Após o período de cicatrização de 6 meses foi instalado o munhão anatômico de 1.5mm altura e confeccionado provisório. Todas as etapas clínicas e laboratoriais foram feitas para a confecção da coroa metalocerâmica. Implantes estreitos apresentam boas taxas de sobrevida e sucesso quando instalados em áreas de pouco esforço mastigatório. Além do mais, estes implantes são excelentes opções para situações em que o espaço mésio-distal é reduzido, impedindo a instalação de implantes de diâmetro padrão.
- 4 February 2025
- Published by Brazilian Journals in Revista Caribeña de Ciencias Sociales
- Vol. 14 (2) , e4455
Open AccessInstalação de implante estreito (2.9mm) para reabilitação unitária em área de incisivo central inferior: relato de caso
Apesar das vantagens da instalação de implantes de diâmetro regular para reabilitações totais, parciais ou unitárias, em algumas situações seu uso está limitado. O implante Facility de 2.9mm de diâmetro é um implante com conexão protética puramente Morse, sem parafusos internos. O presente trabalho tem como objetivo o relato de um caso clínico com a utilização do implante Facility. Paciente de 21 anos, gênero masculino, apresentava agenesia do elemento 32. No exame clínico podia ser observado espaço para a instalação de implante de diâmetro estreito. O tratamento proposto foi instalação de implante 2.9mm de diâmetro (Facility, Curitiba, Brasil) cuja indicação é compatível com o caso apresentado. A instalação do implante foi feita de acordo com a sequência de brocas sugerida pelo fabricante. Foi instalado o implante de 14mm de comprimento, posicionado 1.5mm infra ósseo com um cicatrizador de 2.5mm de altura. Uma prótese provisória adesiva direta foi instalada ao final do procedimento cirúrgico. Após o período de cicatrização de 6 meses foi instalado o munhão anatômico de 1.5mm altura e confeccionado provisório. Todas as etapas clínicas e laboratoriais foram feitas para a confecção da coroa metalocerâmica. Implantes estreitos apresentam boas taxas de sobrevida e sucesso quando instalados em áreas de pouco esforço mastigatório. Além do mais, estes implantes são excelentes opções para situações em que o espaço mésio-distal é reduzido, impedindo a instalação de implantes de diâmetro padrão.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 36, e236422
Influence of Inter-Implant Distance on the Marginal Fit of Milled Structures and Virtual Model Trueness: In Vitro Study
Resumo Este estudo in vitro avaliou o impacto de três distâncias entre implantes (7,14 e21 mm) na veracidade e distorção superficial de modelos gerados por meio de escaneamento intraorais, bem como a desadaptação de estruturas fresadas, analisada por microscopia eletrônica de varredura (MEV). A desadaptação na interface entre as estruturas e os intermediários protéticos também foi mensurada por meio de radiografia digital e MEV. Três modelos com diferentes distâncias entre implantes foram escaneados (n = 10), e um escaneamento de referência para cada modelo foi obtido com scanner de bancada. A veracidade foi avaliada por meio de comparações tridimensionais (3D) das imagens. Cinco estruturas em cobalto-cromo foram fresadas para cada grupo, e as desadaptações nas faces mesial e distal de ambos os implantes foram avaliadas por MEV e radiografia digital. A análise estatística foi realizada com α = 0,05. Não foram encontradas diferenças significativas na veracidade 3D entre as diferentes distâncias entre os implantes (p = 0,373), nem nos valores de desadaptação mesial (p = 0,075) e distal (p = 0,720) do implante anterior. Da mesma forma, não houve diferenças significativas nos valores de desadaptação mesial (p = 0,103) ou distal (p = 0,426) do implante mais posterior. Foi identificada uma forte correlação entre as análises de desadaptação realizadas por radiografia e MEV (r de Pearson = 0,819; p = 0,045). A distância entre os implantes não influenciou significativamente a veracidade ou a adaptação das estruturas fresadas. Todas as estruturas apresentaram boa adaptação aos intermediários protéticos. A forte correlação entre as análises radiográficas e por MEV sugere que a radiografia digital é uma ferramenta confiável para detectar desadaptações entre estruturas fresadas e implantes.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 36, e236422
Open AccessInfluence of Inter-Implant Distance on the Marginal Fit of Milled Structures and Virtual Model Trueness: In Vitro Study
Resumo Este estudo in vitro avaliou o impacto de três distâncias entre implantes (7,14 e21 mm) na veracidade e distorção superficial de modelos gerados por meio de escaneamento intraorais, bem como a desadaptação de estruturas fresadas, analisada por microscopia eletrônica de varredura (MEV). A desadaptação na interface entre as estruturas e os intermediários protéticos também foi mensurada por meio de radiografia digital e MEV. Três modelos com diferentes distâncias entre implantes foram escaneados (n = 10), e um escaneamento de referência para cada modelo foi obtido com scanner de bancada. A veracidade foi avaliada por meio de comparações tridimensionais (3D) das imagens. Cinco estruturas em cobalto-cromo foram fresadas para cada grupo, e as desadaptações nas faces mesial e distal de ambos os implantes foram avaliadas por MEV e radiografia digital. A análise estatística foi realizada com α = 0,05. Não foram encontradas diferenças significativas na veracidade 3D entre as diferentes distâncias entre os implantes (p = 0,373), nem nos valores de desadaptação mesial (p = 0,075) e distal (p = 0,720) do implante anterior. Da mesma forma, não houve diferenças significativas nos valores de desadaptação mesial (p = 0,103) ou distal (p = 0,426) do implante mais posterior. Foi identificada uma forte correlação entre as análises de desadaptação realizadas por radiografia e MEV (r de Pearson = 0,819; p = 0,045). A distância entre os implantes não influenciou significativamente a veracidade ou a adaptação das estruturas fresadas. Todas as estruturas apresentaram boa adaptação aos intermediários protéticos. A forte correlação entre as análises radiográficas e por MEV sugere que a radiografia digital é uma ferramenta confiável para detectar desadaptações entre estruturas fresadas e implantes.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 39, e060
Effect of preservation on the mechanical properties of 3D printing resins for occlusal splints
This study aims to evaluate the mechanical properties of 3D printing resins for occlusal splints (OS) under different preservation conditions based on sleep duration. The study factors (n = 10) included material types: PriZma 3D Bio Splint (PZ), Cosmos Splint (CS), NightGuard Firm (NGF), and self-polymerizing acrylic resin (control group - CG); preservation: artificial saliva (S), natural water (W), 0.12% chlorhexidine (C), and Corega tabs (CTs); and evaluation times: T0 (24 h after fabrication) and 30 d after exposure. Further, the surface roughness (Ra), Knoop microhardness (KH), three-point flexural strength (FS), and flexural modulus (FM) were analyzed. In terms of the time and material, Tukey’s test revealed no significant differences in Ra between the groups at 24 h. After 30 d, PZ showed significantly lower values than the other groups (p < 0.05). For the KH, NGF was significantly higher than that in all groups at 24 h (p < 0.05); after 30 d, the NGF decreased in W and C (p < 0.05), and the NGF and PZ exhibited elevated values in S and CT, respectively. The Kruskal–Wallis test and multiple comparisons showed that the PZ had a higher value at 24 h (p < 0.05). Post 30 d, all 3D-printing resins increased values in CT and S (p < 0.05), and the PZ decreased in the C and W (P < 0.05). Finally, the FM increased under all conditions. The preservation of S and CT partially enhanced the mechanical properties of the OS.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 39, e060
Open AccessEffect of preservation on the mechanical properties of 3D printing resins for occlusal splints
This study aims to evaluate the mechanical properties of 3D printing resins for occlusal splints (OS) under different preservation conditions based on sleep duration. The study factors (n = 10) included material types: PriZma 3D Bio Splint (PZ), Cosmos Splint (CS), NightGuard Firm (NGF), and self-polymerizing acrylic resin (control group - CG); preservation: artificial saliva (S), natural water (W), 0.12% chlorhexidine (C), and Corega tabs (CTs); and evaluation times: T0 (24 h after fabrication) and 30 d after exposure. Further, the surface roughness (Ra), Knoop microhardness (KH), three-point flexural strength (FS), and flexural modulus (FM) were analyzed. In terms of the time and material, Tukey’s test revealed no significant differences in Ra between the groups at 24 h. After 30 d, PZ showed significantly lower values than the other groups (p < 0.05). For the KH, NGF was significantly higher than that in all groups at 24 h (p < 0.05); after 30 d, the NGF decreased in W and C (p < 0.05), and the NGF and PZ exhibited elevated values in S and CT, respectively. The Kruskal–Wallis test and multiple comparisons showed that the PZ had a higher value at 24 h (p < 0.05). Post 30 d, all 3D-printing resins increased values in CT and S (p < 0.05), and the PZ decreased in the C and W (P < 0.05). Finally, the FM increased under all conditions. The preservation of S and CT partially enhanced the mechanical properties of the OS.
- Open Access
- 2 September 2024
- Published by Brazilian Journals in Contribuciones A Las Ciencias Sociales
- Vol. 17 (9) , e11021
Atuação da Liga Acadêmica de Reabilitação Oral (LiARO) como projeto de extensão na propagação de ensino e pesquisa: relato de experiência
A Liga Acadêmica (LA) é um projeto idealizado e organizado pelos próprios alunos de graduação, sob a tutela de professores coordenadores, auxiliando e orientando as atividades realizadas, objetivando estudar e se aprofundar em um determinado tema, atendendo as demandas em saúde da população. Os alunos assumem papel ativo no processo de aprendizado, contemplando uma formação generalista, crítica e condizente com a atual realidade social. A Área de Oclusão, Prótese Fixa e Materiais Odontológicos está presente na vida acadêmica dos discentes da Faculdade de Odontologia da Universidade Federal de Uberlândia (FO-UFU) do segundo ao décimo período do curso, o que demonstra a importância do tema na formação de um cirurgião dentista. Dessa forma, a proposta da Liga Acadêmica de Reabilitação Oral - LiARO-UFU é promover integração entre as diversas áreas clínicas da Odontologia. Proporcionando discussões e produção de material voltados para a comunidade que visem complementar as lacunas e/ou as dificuldades apresentadas durante o curso de Odontologia. Além de buscar ampliar a divulgação científica pelos membros da liga e possibilidade de promover atendimento clínico aos casos de alta complexidade. Com a atuação LiARO, espera-se contribuir para o currículo dos discentes, ampliando as discussões e divulgação científica na área de Reabilitação Oral.
- 2 September 2024
- Published by Brazilian Journals in Contribuciones A Las Ciencias Sociales
- Vol. 17 (9) , e11021
Open AccessAtuação da Liga Acadêmica de Reabilitação Oral (LiARO) como projeto de extensão na propagação de ensino e pesquisa: relato de experiência
A Liga Acadêmica (LA) é um projeto idealizado e organizado pelos próprios alunos de graduação, sob a tutela de professores coordenadores, auxiliando e orientando as atividades realizadas, objetivando estudar e se aprofundar em um determinado tema, atendendo as demandas em saúde da população. Os alunos assumem papel ativo no processo de aprendizado, contemplando uma formação generalista, crítica e condizente com a atual realidade social. A Área de Oclusão, Prótese Fixa e Materiais Odontológicos está presente na vida acadêmica dos discentes da Faculdade de Odontologia da Universidade Federal de Uberlândia (FO-UFU) do segundo ao décimo período do curso, o que demonstra a importância do tema na formação de um cirurgião dentista. Dessa forma, a proposta da Liga Acadêmica de Reabilitação Oral - LiARO-UFU é promover integração entre as diversas áreas clínicas da Odontologia. Proporcionando discussões e produção de material voltados para a comunidade que visem complementar as lacunas e/ou as dificuldades apresentadas durante o curso de Odontologia. Além de buscar ampliar a divulgação científica pelos membros da liga e possibilidade de promover atendimento clínico aos casos de alta complexidade. Com a atuação LiARO, espera-se contribuir para o currículo dos discentes, ampliando as discussões e divulgação científica na área de Reabilitação Oral.
- Open Access
- 25 January 2024
- Published by Conselho Regional De Odontologia De Minas Gerais in Revista Do Cromg
- Vol. 22 (Supl.2)
Planejamento Virtual aplicado a Cirurgia Guiada em caso de reabilitação total com próteses implanto suportadas - relato de caso.
INTRODUÇÃO: A cirurgia guiada revolucionou as reabilitações na Implantodontia devido a tanto ao grande avanço tecnológico nos sistemas de aquisição de imagens quanto a melhora contínua dos softwares de planejamento e das impressoras 3D. As principais vantagens desta técnica são a redução do tempo cirúrgico, aumento da previsibilidade de sucesso, manobras cirúrgicas de alta precisão e confiabilidade e o fato de todo o procedimento se dar em condições flapless, ou seja, sem abertura de retalhos gengivais. O conforto do paciente durante o procedimento é superior à técnica convencional, bem como o pós operatório, devido a diminuição do edema, da dor e da porcentagem de insucesso. Neste trabalho é descrito um caso de reabilitação total superior e inferior com próteses do tipo protocolo com planejamento virtual e cirurgia em maxila por meio de Cirurgia Guiada utilizando o Kit Cirúrgico Grand Morse Neodent Guided Surgery (NEODENT). RELATO DE CASO: Paciente do gênero feminino, 79 anos de idade apresentou-se com queixa estética e funcional, devido a dificuldade mastigatória. Anamnese e história médica pregressa não revelaram restrições. Ao exame clínico intrabucal, observou-se ausência total de elementos dentários em maxila e presença dos elementos 31, 32, 41, 42 e 43, com mobilidade grau 1 devido a considerável perda de inserção e a presença de uma lesão periapical associada aos dentes 31 e 32. De acordo com a possibilidade e pretensão da paciente, no arco inferior ficou definida a confecção de uma prótese tipo protocolo sobre 4 implantes e no arco superior optou pela Cirurgia Guiada e prótese tipo protocolo sobre 6 implantes. O tratamento iniciou-se pelo arco superior. O exame tomográfico da maxila foi realizado e a própria prótese da paciente foi utilizada como guia para o exame. As imagens tomográficas adquiridas foram trabalhadas no programa coDiagnostiXTM. Obtidas as imagens tridimensionais, simulou-se, por meio do software coDiagnostiXTM a distribuição dos implantes, posicionados com relação à anatomia do paciente e o resultado protético desejado. Feito o planejamento virtual, os dados foram exportados e o Guia Cirúrgico foi impresso na impressora Anycubic Photon Mono com a resina Resina priZma 3D Bio Guide. Neste passo, foram instaladas as anilhas Neodent para cirurgia guiada. Após a prova e a fixação do guia na posição, o procedimento de fresagem iniciou-se normalmente. O uso de um Punch (Extrator Mucoso) permitiu acessar o tecido ósseo com menor dano ao tecido gengival. O diâmetro das aberturas presentes no Guia Cirúrgico foi ajustado pelos Guias de Broca GM NGS, que corresponderam ao diâmetro dos implantes escolhidos para cada região. As brocas utilizadas para ampliar o diâmetro da fresagem têm um batente próprio que deve ser tocado na borda do Guia de Broca, que esteve devidamente em posição durante o procedimento. Este batente, presente na broca associado à posição da borda do Guia de Broca aos comprimentos pré-determinados no Guia, dá a profundidade exata de perfuração. Finalizadas as fresagens e instalações dos implantes, removeu-se o Guia Cirúrgico e pôde-se observar quão conservador foi o procedimento, quão benéfico aos tecidos ósseos e gengivais e por fim, quão menos agressivo foi ao paciente. O procedimento cirúrgico ocorreu sem intercorrências, porém devido ao torque insuficiente nos seis implantes, optou-se pela técnica convencional e não pela carga imediata, com a instalação da prótese total superior convencional aliviada e reembasada com material resiliente, a qual permanecerá nesta condição durante o período de cicatrização. Em posterior sessão, foi realizada a reabilitação do arco inferior. A definição do local, diâmetro e comprimento dos implantes foi realizada com auxílio dos traçados realizados por sobreposição na tomografia computadorizada. Conforme planejamento os dentes inferiores presentes foram extraídos seguindo-se com a remoção da lesão, curetagem do local e regularização do rebordo alveolar com alveolótomo biarticulado, visando a uniformização do rebordo e consequentemente aumento da distância vestíbulo lingual, possibilitando a instalação de implantes de maior diâmetro. Foram instalados 4 implantes (GM HELIX IMPLANT 3.75x10mm, Neodent) na região interforaminal. O procedimento cirúrgico ocorreu sem intercorrências, houve torque suficiente (45Ncm) nos quatro implantes e optou-se pela carga imediata. Os pilares foram selecionados e instalados, seguidos dos transferentes, os quais foram transferidos por meio de moldagem. Os componentes foram envolvidos com resina acrílica e hastes metálicas rígidas para criar um index. Removido o index após a cura da resina acrílica, ele foi parafusado nos análogos dos implantes e posicionado em uma caixa com gesso. Os cilindros provisórios foram instalados nos implantes e conectados à base da prótese usando resina acrílica, com o paciente em oclusão. Após a cura da resina, a prótese foi removida e posicionada sobre o modelo. A captura das barras distais foi feita sem preocupações adicionais com a posição, fora da boca, usando o index. As superfícies palatinas e áreas de flange foram removidas, a prótese foi finalizada, polida, instalada e foram realizados os ajustes oclusais. CONCLUSÃO: Podemos concluir que com critérios bem definidos com base no diagnóstico e planejamento reverso, associados a técnicas cirúrgicas e protéticas, torna-se possível ter previsibilidade e sucesso nos tratamentos de reabilitação de pacientes. A técnica da Cirurgia Guiada possibilitou a obtenção de excelentes resultados, com uma diminuição no tempo da cirurgia, redução das lesões nos tecidos gengivais normalmente provocadas e uma instalação dos implantes tridimensionalmente precisa. Nossas conclusões apontam para a eficácia e replicabilidade dessa abordagem, capaz de melhorar a função mastigatória, estética e o aspecto da autoestima do paciente.
- 25 January 2024
- Published by Conselho Regional De Odontologia De Minas Gerais in Revista Do Cromg
- Vol. 22 (Supl.2)
Open AccessPlanejamento Virtual aplicado a Cirurgia Guiada em caso de reabilitação total com próteses implanto suportadas - relato de caso.
INTRODUÇÃO: A cirurgia guiada revolucionou as reabilitações na Implantodontia devido a tanto ao grande avanço tecnológico nos sistemas de aquisição de imagens quanto a melhora contínua dos softwares de planejamento e das impressoras 3D. As principais vantagens desta técnica são a redução do tempo cirúrgico, aumento da previsibilidade de sucesso, manobras cirúrgicas de alta precisão e confiabilidade e o fato de todo o procedimento se dar em condições flapless, ou seja, sem abertura de retalhos gengivais. O conforto do paciente durante o procedimento é superior à técnica convencional, bem como o pós operatório, devido a diminuição do edema, da dor e da porcentagem de insucesso. Neste trabalho é descrito um caso de reabilitação total superior e inferior com próteses do tipo protocolo com planejamento virtual e cirurgia em maxila por meio de Cirurgia Guiada utilizando o Kit Cirúrgico Grand Morse Neodent Guided Surgery (NEODENT). RELATO DE CASO: Paciente do gênero feminino, 79 anos de idade apresentou-se com queixa estética e funcional, devido a dificuldade mastigatória. Anamnese e história médica pregressa não revelaram restrições. Ao exame clínico intrabucal, observou-se ausência total de elementos dentários em maxila e presença dos elementos 31, 32, 41, 42 e 43, com mobilidade grau 1 devido a considerável perda de inserção e a presença de uma lesão periapical associada aos dentes 31 e 32. De acordo com a possibilidade e pretensão da paciente, no arco inferior ficou definida a confecção de uma prótese tipo protocolo sobre 4 implantes e no arco superior optou pela Cirurgia Guiada e prótese tipo protocolo sobre 6 implantes. O tratamento iniciou-se pelo arco superior. O exame tomográfico da maxila foi realizado e a própria prótese da paciente foi utilizada como guia para o exame. As imagens tomográficas adquiridas foram trabalhadas no programa coDiagnostiXTM. Obtidas as imagens tridimensionais, simulou-se, por meio do software coDiagnostiXTM a distribuição dos implantes, posicionados com relação à anatomia do paciente e o resultado protético desejado. Feito o planejamento virtual, os dados foram exportados e o Guia Cirúrgico foi impresso na impressora Anycubic Photon Mono com a resina Resina priZma 3D Bio Guide. Neste passo, foram instaladas as anilhas Neodent para cirurgia guiada. Após a prova e a fixação do guia na posição, o procedimento de fresagem iniciou-se normalmente. O uso de um Punch (Extrator Mucoso) permitiu acessar o tecido ósseo com menor dano ao tecido gengival. O diâmetro das aberturas presentes no Guia Cirúrgico foi ajustado pelos Guias de Broca GM NGS, que corresponderam ao diâmetro dos implantes escolhidos para cada região. As brocas utilizadas para ampliar o diâmetro da fresagem têm um batente próprio que deve ser tocado na borda do Guia de Broca, que esteve devidamente em posição durante o procedimento. Este batente, presente na broca associado à posição da borda do Guia de Broca aos comprimentos pré-determinados no Guia, dá a profundidade exata de perfuração. Finalizadas as fresagens e instalações dos implantes, removeu-se o Guia Cirúrgico e pôde-se observar quão conservador foi o procedimento, quão benéfico aos tecidos ósseos e gengivais e por fim, quão menos agressivo foi ao paciente. O procedimento cirúrgico ocorreu sem intercorrências, porém devido ao torque insuficiente nos seis implantes, optou-se pela técnica convencional e não pela carga imediata, com a instalação da prótese total superior convencional aliviada e reembasada com material resiliente, a qual permanecerá nesta condição durante o período de cicatrização. Em posterior sessão, foi realizada a reabilitação do arco inferior. A definição do local, diâmetro e comprimento dos implantes foi realizada com auxílio dos traçados realizados por sobreposição na tomografia computadorizada. Conforme planejamento os dentes inferiores presentes foram extraídos seguindo-se com a remoção da lesão, curetagem do local e regularização do rebordo alveolar com alveolótomo biarticulado, visando a uniformização do rebordo e consequentemente aumento da distância vestíbulo lingual, possibilitando a instalação de implantes de maior diâmetro. Foram instalados 4 implantes (GM HELIX IMPLANT 3.75x10mm, Neodent) na região interforaminal. O procedimento cirúrgico ocorreu sem intercorrências, houve torque suficiente (45Ncm) nos quatro implantes e optou-se pela carga imediata. Os pilares foram selecionados e instalados, seguidos dos transferentes, os quais foram transferidos por meio de moldagem. Os componentes foram envolvidos com resina acrílica e hastes metálicas rígidas para criar um index. Removido o index após a cura da resina acrílica, ele foi parafusado nos análogos dos implantes e posicionado em uma caixa com gesso. Os cilindros provisórios foram instalados nos implantes e conectados à base da prótese usando resina acrílica, com o paciente em oclusão. Após a cura da resina, a prótese foi removida e posicionada sobre o modelo. A captura das barras distais foi feita sem preocupações adicionais com a posição, fora da boca, usando o index. As superfícies palatinas e áreas de flange foram removidas, a prótese foi finalizada, polida, instalada e foram realizados os ajustes oclusais. CONCLUSÃO: Podemos concluir que com critérios bem definidos com base no diagnóstico e planejamento reverso, associados a técnicas cirúrgicas e protéticas, torna-se possível ter previsibilidade e sucesso nos tratamentos de reabilitação de pacientes. A técnica da Cirurgia Guiada possibilitou a obtenção de excelentes resultados, com uma diminuição no tempo da cirurgia, redução das lesões nos tecidos gengivais normalmente provocadas e uma instalação dos implantes tridimensionalmente precisa. Nossas conclusões apontam para a eficácia e replicabilidade dessa abordagem, capaz de melhorar a função mastigatória, estética e o aspecto da autoestima do paciente.
- Open Access
- 25 January 2024
- Published by Conselho Regional De Odontologia De Minas Gerais in Revista Do Cromg
- Vol. 22 (Supl.2)
Coroas Totais em Resinas Impressas Obtidas por Sistema CAD/CAM – relato de caso.
Introdução: A Odontologia digital está cada vez mais presente na realidade dos consultórios, principalmente pela implementação da tecnologia CAI/CAD/CAM – onde, até alguns anos atrás, o fresamento era o principal método usado para se obter restaurações indiretas. Porém, visando que o fresamento resulta em perda significativa de material durante a fabricação de peças por meio de subtração, bem como desgaste de ferramentas como pontas de diamante e brocas, o que pode afetar a adaptabilidade marginal das restaurações, têm se buscado alternativas para utilização desse sistema. Com isso, as novas tecnologias vêm aprimorando as impressoras 3D para uso odontológico, possibilitando a impressão de estruturas com materiais biocompatíveis e resistentes, como os compostos resinosos. O objetivo deste relato de caso é demonstrar uma reabilitação por meio de coroas totais de resinas impressas em impressora 3D, em fluxo totalmente digital CAD/CAM. Descrição do caso: Foi planejado ao paciente, após exame clínico e radiográfico, coroas totais nos dentes 44 e 45 – os quais foram preparados seguindo a técnica da silhueta modificada. Em seguida, com a técnica do duplo fio, os dentes foram escaneados utilizando o scanner intraoral Virtuo Vivo (Straumann) e os arquivos STL (Standard Tessellation Language) enviados ao laboratório para impressão das coroas definitivas. Foi confeccionada uma coroa provisória de resina acrílica (Dencrilay Speed, Dencryl), e o paciente liberado. Em um segundo momento, as coroas foram impressas e tratadas de acordo com recomendação do fabricante das resinas. Uma semana após o preparo, o paciente retornou para prova, ajuste e cimentação das coroas definitivas, o qual foi feito com cimento resinoso Allcem (FGM). Por fim, todos os ajustes foram realizados e o acabamento dado com as brocas para tal finalidade. Foram utilizadas as resinas VarseoSmile Crown (Wilcos, Alemanha) e PriZma 3D Biocrown (Maquira, Brasil) de maneira randomizada e cega. Resultados: Ao final do atendimento, por meio de exame clínico e radiográfico, foi possível observar que as coroas ficaram bem-adaptadas e com uma anatomia satisfatória, o que era o ponto principal deste relato de caso. Essa alternativa representa ainda uma diminuição dos custos, já que em média, um litro de resina pode ser utilizado na impressão de aproximadamente 300 coroas unitárias, enquanto seria necessário um bloco para cada coroa nos sistemas de fresagem. Conclusão/ Considerações finais: O uso da impressora 3D alinhada ao CAD/CAM é uma excelente alternativa para resolução de casos como o relatado. É importante relatar que, a ideia do caso relatado originou uma pesquisa de mestrado na Universidade Federal de Uberlândia, onde será avaliado os benefícios de inserir essa alternativa no serviço público, visando mais rapidez na resolução dos casos, menor desconforto ao paciente e redução de custos públicos.
- 25 January 2024
- Published by Conselho Regional De Odontologia De Minas Gerais in Revista Do Cromg
- Vol. 22 (Supl.2)
Open AccessCoroas Totais em Resinas Impressas Obtidas por Sistema CAD/CAM – relato de caso.
Introdução: A Odontologia digital está cada vez mais presente na realidade dos consultórios, principalmente pela implementação da tecnologia CAI/CAD/CAM – onde, até alguns anos atrás, o fresamento era o principal método usado para se obter restaurações indiretas. Porém, visando que o fresamento resulta em perda significativa de material durante a fabricação de peças por meio de subtração, bem como desgaste de ferramentas como pontas de diamante e brocas, o que pode afetar a adaptabilidade marginal das restaurações, têm se buscado alternativas para utilização desse sistema. Com isso, as novas tecnologias vêm aprimorando as impressoras 3D para uso odontológico, possibilitando a impressão de estruturas com materiais biocompatíveis e resistentes, como os compostos resinosos. O objetivo deste relato de caso é demonstrar uma reabilitação por meio de coroas totais de resinas impressas em impressora 3D, em fluxo totalmente digital CAD/CAM. Descrição do caso: Foi planejado ao paciente, após exame clínico e radiográfico, coroas totais nos dentes 44 e 45 – os quais foram preparados seguindo a técnica da silhueta modificada. Em seguida, com a técnica do duplo fio, os dentes foram escaneados utilizando o scanner intraoral Virtuo Vivo (Straumann) e os arquivos STL (Standard Tessellation Language) enviados ao laboratório para impressão das coroas definitivas. Foi confeccionada uma coroa provisória de resina acrílica (Dencrilay Speed, Dencryl), e o paciente liberado. Em um segundo momento, as coroas foram impressas e tratadas de acordo com recomendação do fabricante das resinas. Uma semana após o preparo, o paciente retornou para prova, ajuste e cimentação das coroas definitivas, o qual foi feito com cimento resinoso Allcem (FGM). Por fim, todos os ajustes foram realizados e o acabamento dado com as brocas para tal finalidade. Foram utilizadas as resinas VarseoSmile Crown (Wilcos, Alemanha) e PriZma 3D Biocrown (Maquira, Brasil) de maneira randomizada e cega. Resultados: Ao final do atendimento, por meio de exame clínico e radiográfico, foi possível observar que as coroas ficaram bem-adaptadas e com uma anatomia satisfatória, o que era o ponto principal deste relato de caso. Essa alternativa representa ainda uma diminuição dos custos, já que em média, um litro de resina pode ser utilizado na impressão de aproximadamente 300 coroas unitárias, enquanto seria necessário um bloco para cada coroa nos sistemas de fresagem. Conclusão/ Considerações finais: O uso da impressora 3D alinhada ao CAD/CAM é uma excelente alternativa para resolução de casos como o relatado. É importante relatar que, a ideia do caso relatado originou uma pesquisa de mestrado na Universidade Federal de Uberlândia, onde será avaliado os benefícios de inserir essa alternativa no serviço público, visando mais rapidez na resolução dos casos, menor desconforto ao paciente e redução de custos públicos.