Aleksander A. Zheravin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aleksander A. Zheravin has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Evgeniia S. Vikulova
Nikolaev Institute of Inorganic Chemistry, Siberian Branch, Russian Academy of Sciences, Ac. Lavrentiev Ave. 3, 630090 Novosibirsk, Russia
2 shared publications - Natalya B. Morozova
Nikolaev Institute of Inorganic Chemistry, Siberian Branch, Russian Academy of Sciences, Ac. Lavrentiev Ave. 3, 630090 Novosibirsk, Russia
2 shared publications - Svetlana I. Dorovskikh
Nikolaev Institute of Inorganic Chemistry, Siberian Branch, Russian Academy of Sciences, Ac. Lavrentiev Ave. 3, 630090 Novosibirsk, Russia
2 shared publications A. S. Kudryavtsev
1 shared publication- Aleksei Nikitich Kolodin
Nikolaev Institute of Inorganic Chemistry, Siberian Branch, Russian Academy of Sciences, Novosibirsk, Russia
1 shared publication - Anastasiya D. Fedorenko
Nikolaev Institute of Inorganic Chemistry, Siberian Branch, Russian Academy of Sciences, Ac. Lavrentiev Ave. 3, 630090 Novosibirsk, Russia
1 shared publication
Latest Publications
- Open Access
- 27 October 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (11) , 547
Ti-Containing Mesh Implants Modified by Heterostructures Based on Noble Metal: Fabrication and Study of Biological Activity
Ti-based mesh implants (“titanium silk” TiS and NiTi alloy) offer excellent tissue integration for oncologic surgery but lack intrinsic antibacterial activity. To address this, we fabricated Ag nanoparticles and Ag/M (M = Pt, Au) heterostructures on mesh surfaces via vapor-phase deposition, with noble metal sublayers functionalized by Ag nanofilms and nanoclusters. The modified implants were comprehensively characterized using SEM, AFM, XPS, and ICP-AES and evaluated through in vitro biocompatibility and antibacterial assays. The functional performance of the heterostructures is governed by two key phenomena: a chemical sublayer effect and a geometry-dependent substrate effect, which together dictate ion release kinetics. The Ag/Au interface sustains Ag+ release, whereas Ag/Pt drives rapid Ag+ dissolution. All heterostructures demonstrated effective antibacterial activity against planktonic S. aureus within 24 h. Key factors responsible for reduction in the more resilient P. aeruginosa on the Ag/M heterostructures were hypothesized. Cytotoxicity was dictated by the released ion cocktail: Ag/Pt/NiTi exhibited elevated toxicity which may be associated with the combined release of Ag+, Ni2+ and Pt2+, whereas all Ag/Au-based heterostructures showed excellent biocompatibility (viability 75–108%). Notably, gold sublayers were associated with elevated IL-10 secretion by 72 h. Based on overall biological performance, Ag/Au heterostructures offering sustained antibacterial activity against planktonic bacteria, low cytotoxicity, and a cytokine profile that may be favorable for long-term integration are promising candidates for mesh implants. Also, h-Ag/Pt/TiS showed an optimal balance between rapid antibacterial action and biocompatibility and therefore appears to be a suitable candidate for further in vivo investigation.
- 27 October 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (11) , 547
Open AccessTi-Containing Mesh Implants Modified by Heterostructures Based on Noble Metal: Fabrication and Study of Biological Activity
Ti-based mesh implants (“titanium silk” TiS and NiTi alloy) offer excellent tissue integration for oncologic surgery but lack intrinsic antibacterial activity. To address this, we fabricated Ag nanoparticles and Ag/M (M = Pt, Au) heterostructures on mesh surfaces via vapor-phase deposition, with noble metal sublayers functionalized by Ag nanofilms and nanoclusters. The modified implants were comprehensively characterized using SEM, AFM, XPS, and ICP-AES and evaluated through in vitro biocompatibility and antibacterial assays. The functional performance of the heterostructures is governed by two key phenomena: a chemical sublayer effect and a geometry-dependent substrate effect, which together dictate ion release kinetics. The Ag/Au interface sustains Ag+ release, whereas Ag/Pt drives rapid Ag+ dissolution. All heterostructures demonstrated effective antibacterial activity against planktonic S. aureus within 24 h. Key factors responsible for reduction in the more resilient P. aeruginosa on the Ag/M heterostructures were hypothesized. Cytotoxicity was dictated by the released ion cocktail: Ag/Pt/NiTi exhibited elevated toxicity which may be associated with the combined release of Ag+, Ni2+ and Pt2+, whereas all Ag/Au-based heterostructures showed excellent biocompatibility (viability 75–108%). Notably, gold sublayers were associated with elevated IL-10 secretion by 72 h. Based on overall biological performance, Ag/Au heterostructures offering sustained antibacterial activity against planktonic bacteria, low cytotoxicity, and a cytokine profile that may be favorable for long-term integration are promising candidates for mesh implants. Also, h-Ag/Pt/TiS showed an optimal balance between rapid antibacterial action and biocompatibility and therefore appears to be a suitable candidate for further in vivo investigation.
- Open Access
Silver CVD and ALD Precursors: Synthesis, Properties, and Application in Deposition Processes
This review summarized the developments in the field of volatile silver complexes, which can serve as precursors in gas-transport reactions for the production of thin films and metal nanoparticles via chemical vapor deposition (CVD) and atomic layer deposition (ALD). Silver-based films and nanoparticles are widely used in various high-tech fields, including medicine. For effective use in CVD and ALD processes, the properties of silver precursors must be balanced in terms of volatility, thermal stability, and reactivity. In this review, we focus on the synthesis and comprehensive analysis of structural and thermal characteristics for the most promising classes of volatile silver complexes, as well as organometallic compounds. Following the specifics of silver chemistry, some features of the use of precursors and their selection, as well as several key directions to improving the efficiency of silver material deposition processes, are also discussed.
Open AccessSilver CVD and ALD Precursors: Synthesis, Properties, and Application in Deposition Processes
This review summarized the developments in the field of volatile silver complexes, which can serve as precursors in gas-transport reactions for the production of thin films and metal nanoparticles via chemical vapor deposition (CVD) and atomic layer deposition (ALD). Silver-based films and nanoparticles are widely used in various high-tech fields, including medicine. For effective use in CVD and ALD processes, the properties of silver precursors must be balanced in terms of volatility, thermal stability, and reactivity. In this review, we focus on the synthesis and comprehensive analysis of structural and thermal characteristics for the most promising classes of volatile silver complexes, as well as organometallic compounds. Following the specifics of silver chemistry, some features of the use of precursors and their selection, as well as several key directions to improving the efficiency of silver material deposition processes, are also discussed.
- 1 January 2018
- Published by Media Sphere Publishing Group in Endoscopic Surgery
- Vol. 24 (4) , 45-48
Complications of application of metal self-expandable stents for esophageal tumors and tumors of esophageal anastomoses
- 1 January 2018
- Published by Media Sphere Publishing Group in Endoscopic Surgery
- Vol. 24 (4) , 45-48
Complications of application of metal self-expandable stents for esophageal tumors and tumors of esophageal anastomoses
- Open Access
- 17 July 2017
- Published by Knowledge E DMCC in KnE Materials Science
- Vol. 2 (1) , 200-204
Long-Term Results of Chest Wall Reconstruction After Tumor Resection Using TiNi Implants
Long-Term Results of Chest Wall Reconstruction After Tumor Resection Using TiNi Implants
- 17 July 2017
- Published by Knowledge E DMCC in KnE Materials Science
- Vol. 2 (1) , 200-204
Open AccessLong-Term Results of Chest Wall Reconstruction After Tumor Resection Using TiNi Implants
Long-Term Results of Chest Wall Reconstruction After Tumor Resection Using TiNi Implants
- Open Access
- 17 July 2017
- Published by Knowledge E DMCC in KnE Materials Science
- Vol. 2 (1) , 480-485
Surgical Correction of Child Pectus Excavatum by TiNi-based Materials
This article describes the serious and urgent issue of surgical treatment of congenital child pectus excavatum and the approaches in the surgical correction of this children pathology. The authors propose an original surgical treatment method in applying TiNi-based materials possessing shape memory in OP treatment of pectus excavatum. Plain integral TiNi-based plasty creates supplemental correction force due to the material isoelastic properties, providing stable fixation of corrected chest section throughout the immobilization period.
- 17 July 2017
- Published by Knowledge E DMCC in KnE Materials Science
- Vol. 2 (1) , 480-485
Open AccessSurgical Correction of Child Pectus Excavatum by TiNi-based Materials
This article describes the serious and urgent issue of surgical treatment of congenital child pectus excavatum and the approaches in the surgical correction of this children pathology. The authors propose an original surgical treatment method in applying TiNi-based materials possessing shape memory in OP treatment of pectus excavatum. Plain integral TiNi-based plasty creates supplemental correction force due to the material isoelastic properties, providing stable fixation of corrected chest section throughout the immobilization period.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1760 (1) , 020006
Calcium phosphate coatings produced by radiofrequency magnetron sputtering method
Calcium phosphate coatings on titanium implants surface, produced by radio frequency (RF) magnetron sputtering method with hydroxyapatite solid target were investigated. It was found that produced coatings are calcium deficient compared to stoichiometric hydroxyapatite. The surface of the coatings is highly rough at the nanoscale and highly elastic. In vivo experiments on rats revealed that titanium implants with the calcium phosphate coatings do not cause negative tissue reaction after 6 months incubation period.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1760 (1) , 020006
Calcium phosphate coatings produced by radiofrequency magnetron sputtering method
Calcium phosphate coatings on titanium implants surface, produced by radio frequency (RF) magnetron sputtering method with hydroxyapatite solid target were investigated. It was found that produced coatings are calcium deficient compared to stoichiometric hydroxyapatite. The surface of the coatings is highly rough at the nanoscale and highly elastic. In vivo experiments on rats revealed that titanium implants with the calcium phosphate coatings do not cause negative tissue reaction after 6 months incubation period.