Kazuta Yamashita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kazuta Yamashita has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
Koichi Sairyo
Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School
11 shared publicationsKosaku Higashino
Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School
7 shared publicationsFumitake Tezuka
Department of Orthopedics, Tokushima University, Tokushima, Tokushima, Japan
6 shared publicationsHiroaki Hayashi
Department of Pharmaceutical and Health Sciences, Kanazawa University Graduate School
5 shared publicationsToshinori Sakai
Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
5 shared publicationsYoichiro Takata
Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
5 shared publications
Latest Publications
- 17 October 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 224,p. e69059
Transforaminal Full-Endoscopic Lumbar Foraminotomy Under Local Anesthesia for L5/S1 Adjacent Segment Foraminal Stenosis
Foraminal stenosis in patients with L5/S1 adjacent segment disease (ASD) presents a significant clinical challenge, as conventional treatment often requires fusion extension surgery. This approach sacrifices spinal mobility and is associated with considerable surgical morbidity. This video article describes a motion-preserving surgical alternative, namely, transforaminal full-endoscopic foraminotomy performed under local anesthesia, detailing a step-by-step protocol to navigate the challenges of these revision cases. The technique utilizes a posterolateral corridor, avoiding prior surgical scarring. Key procedural steps include meticulous preoperative trajectory planning, foraminoplasty via resection of the superior articular process (SAP), and partial resection of the inferior articular process to fully expose the ligamentum flavum (LF). A specific "detach" technique is then demonstrated, involving undercutting the ventral rim of the S1 SAP to release the LF before its removal. Representative results demonstrate successful osseous decompression confirmed by postoperative computed tomography. The procedure resulted in immediate improvement in radicular pain and motor weakness, with the patient's visual analog scale score decreasing from 9/10 to 1/10 at the one-month follow-up. This minimally invasive technique provides effective neural decompression and facilitates rapid recovery, offering a valuable alternative to more extensive surgery for this challenging patient population.
- 17 October 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 224,p. e69059
Transforaminal Full-Endoscopic Lumbar Foraminotomy Under Local Anesthesia for L5/S1 Adjacent Segment Foraminal Stenosis
Foraminal stenosis in patients with L5/S1 adjacent segment disease (ASD) presents a significant clinical challenge, as conventional treatment often requires fusion extension surgery. This approach sacrifices spinal mobility and is associated with considerable surgical morbidity. This video article describes a motion-preserving surgical alternative, namely, transforaminal full-endoscopic foraminotomy performed under local anesthesia, detailing a step-by-step protocol to navigate the challenges of these revision cases. The technique utilizes a posterolateral corridor, avoiding prior surgical scarring. Key procedural steps include meticulous preoperative trajectory planning, foraminoplasty via resection of the superior articular process (SAP), and partial resection of the inferior articular process to fully expose the ligamentum flavum (LF). A specific "detach" technique is then demonstrated, involving undercutting the ventral rim of the S1 SAP to release the LF before its removal. Representative results demonstrate successful osseous decompression confirmed by postoperative computed tomography. The procedure resulted in immediate improvement in radicular pain and motor weakness, with the patient's visual analog scale score decreasing from 9/10 to 1/10 at the one-month follow-up. This minimally invasive technique provides effective neural decompression and facilitates rapid recovery, offering a valuable alternative to more extensive surgery for this challenging patient population.
- 17 October 2025
- Published by MyJove Corporation
- No. 224,p. e69059
JoVE Video Dataset
Foraminal stenosis in patients with L5/S1 adjacent segment disease (ASD) presents a significant clinical challenge, as conventional treatment often requires fusion extension surgery. This approach sacrifices spinal mobility and is associated with considerable surgical morbidity. This video article describes a motion-preserving surgical alternative, namely, transforaminal full-endoscopic foraminotomy performed under local anesthesia, detailing a step-by-step protocol to navigate the challenges of these revision cases. The technique utilizes a posterolateral corridor, avoiding prior surgical scarring. Key procedural steps include meticulous preoperative trajectory planning, foraminoplasty via resection of the superior articular process (SAP), and partial resection of the inferior articular process to fully expose the ligamentum flavum (LF). A specific "detach" technique is then demonstrated, involving undercutting the ventral rim of the S1 SAP to release the LF before its removal. Representative results demonstrate successful osseous decompression confirmed by postoperative computed tomography. The procedure resulted in immediate improvement in radicular pain and motor weakness, with the patient's visual analog scale score decreasing from 9/10 to 1/10 at the one-month follow-up. This minimally invasive technique provides effective neural decompression and facilitates rapid recovery, offering a valuable alternative to more extensive surgery for this challenging patient population.
- 17 October 2025
- Published by MyJove Corporation
- No. 224,p. e69059
JoVE Video Dataset
Foraminal stenosis in patients with L5/S1 adjacent segment disease (ASD) presents a significant clinical challenge, as conventional treatment often requires fusion extension surgery. This approach sacrifices spinal mobility and is associated with considerable surgical morbidity. This video article describes a motion-preserving surgical alternative, namely, transforaminal full-endoscopic foraminotomy performed under local anesthesia, detailing a step-by-step protocol to navigate the challenges of these revision cases. The technique utilizes a posterolateral corridor, avoiding prior surgical scarring. Key procedural steps include meticulous preoperative trajectory planning, foraminoplasty via resection of the superior articular process (SAP), and partial resection of the inferior articular process to fully expose the ligamentum flavum (LF). A specific "detach" technique is then demonstrated, involving undercutting the ventral rim of the S1 SAP to release the LF before its removal. Representative results demonstrate successful osseous decompression confirmed by postoperative computed tomography. The procedure resulted in immediate improvement in radicular pain and motor weakness, with the patient's visual analog scale score decreasing from 9/10 to 1/10 at the one-month follow-up. This minimally invasive technique provides effective neural decompression and facilitates rapid recovery, offering a valuable alternative to more extensive surgery for this challenging patient population.
- Open Access
- 27 September 2025
- Published by Japanese Society for Spine Surgery and Related Research in Spine Surgery and Related Research
- Vol. 9 (5) , 588-595
Occupational Radiation Exposure for a Spinal Interventionalist Performing Fluoroscopic Selective Nerve Root Block: A Cadaveric Study
Introduction: Awareness of the harmful effects of long-term low-dose radiation is increasing. There are few comprehensive reports that accurately evaluate the radiation exposure dose to spinal interventionalists during selective nerve root block (SNRB). The purpose of this study was to evaluate the radiation exposure doses from C-arm fluoroscopy to different body areas of the interventionalist and to assess the effectiveness of lead-equivalent protective gear in reducing radiation exposure during SNRB.Methods: Seven fresh cadavers were irradiated for 1 and 3 minutes using C-arm fluoroscopy to stimulate the real clinical setting of SNRB. The X-ray source was positioned both under and over the table. Radiation exposure doses were measured using real-time dosimeters. Lead-equivalent protective gear was placed on each body part (crystalline lens, thyroid gland, chest, non-dominant hand, dominant hand, gonads, and foot).Results: Scatter radiation exposure doses to the upper body of the interventionalist were much higher when the X-ray source was positioned over the table compared to when it was positioned under the table. Use of X-ray protective gear reduced radiation exposure to the interventionalist regardless of the X-ray source position. The direct radiation dose to the hand in the irradiated field was extremely high when the X-ray source was positioned over the table—approximately 85 times higher than when under the table. Notably, hand doses remained extremely high even when the interventionalist wore protective gloves, although X-ray-protective-gear reduced overall radiation exposure.Conclusion: This is the first report to quantify both scattered and direct radiation doses to each body part, as well as the reduction effect of using X-ray protective gear, in detail using fresh cadavers instead of patients. Spinal interventionalists should preferentially use an under-table X-ray source during SNRB and should consistently wear adequate X-ray-protective gear to minimize occupational radiation exposure.
- 27 September 2025
- Published by Japanese Society for Spine Surgery and Related Research in Spine Surgery and Related Research
- Vol. 9 (5) , 588-595
Open AccessOccupational Radiation Exposure for a Spinal Interventionalist Performing Fluoroscopic Selective Nerve Root Block: A Cadaveric Study
Introduction: Awareness of the harmful effects of long-term low-dose radiation is increasing. There are few comprehensive reports that accurately evaluate the radiation exposure dose to spinal interventionalists during selective nerve root block (SNRB). The purpose of this study was to evaluate the radiation exposure doses from C-arm fluoroscopy to different body areas of the interventionalist and to assess the effectiveness of lead-equivalent protective gear in reducing radiation exposure during SNRB.Methods: Seven fresh cadavers were irradiated for 1 and 3 minutes using C-arm fluoroscopy to stimulate the real clinical setting of SNRB. The X-ray source was positioned both under and over the table. Radiation exposure doses were measured using real-time dosimeters. Lead-equivalent protective gear was placed on each body part (crystalline lens, thyroid gland, chest, non-dominant hand, dominant hand, gonads, and foot).Results: Scatter radiation exposure doses to the upper body of the interventionalist were much higher when the X-ray source was positioned over the table compared to when it was positioned under the table. Use of X-ray protective gear reduced radiation exposure to the interventionalist regardless of the X-ray source position. The direct radiation dose to the hand in the irradiated field was extremely high when the X-ray source was positioned over the table—approximately 85 times higher than when under the table. Notably, hand doses remained extremely high even when the interventionalist wore protective gloves, although X-ray-protective-gear reduced overall radiation exposure.Conclusion: This is the first report to quantify both scattered and direct radiation doses to each body part, as well as the reduction effect of using X-ray protective gear, in detail using fresh cadavers instead of patients. Spinal interventionalists should preferentially use an under-table X-ray source during SNRB and should consistently wear adequate X-ray-protective gear to minimize occupational radiation exposure.
- 5 September 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (12) , 5765-5772
Approach-related safety considerations for transforaminal full-endoscopic lumbar spine surgery
- 5 September 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (12) , 5765-5772
Approach-related safety considerations for transforaminal full-endoscopic lumbar spine surgery
- Open Access
- 20 March 2024
- Published by Springer Nature in Research Square
Occupational radiation protection for the medical staff during the fluoroscopic spinal procedure: Are we protected adequately?; A cadaveric simulation study
Background Fluoroscopy is crucial in spine surgery, but exposes medical staff to scattered radiation, raising concerns about health risks. The effectiveness of using protective equipment to reduce occupational exposure remains uncertain. Objective The purpose of this study was to evaluate actual radiation exposure doses and shielding effectiveness during simulated spine surgery. Methods Using seven fresh cadavers and mannequins, radiation exposure was measured with and without protective equipment. The X-ray source was positioned under the table, over the table, and laterally. Radiation exposure doses were measured at different simulated areas such as the optic lens, thyroid gland, and hand of the medical staff. Results There were significant differences in the radiation exposure dose under different conditions and for different irradiated areas. The protective equipment significantly reduced radiation exposure. However, exposure remained relatively high, especially to the surgeon's lens and hand when the radiation source was positioned over and laterally. Exposure to scrub nurses and anesthesiologists was relatively low. Conclusions Shielding is critical, but the complete elimination of radiation exposure is challenging. Overall, protective equipment is effective in reducing occupational radiation exposure, but additional measures may be necessary, especially when the radiation source is positioned over the table and laterally. Our results provide a guide for medical staff to understand the risk of radiation exposure.
- 20 March 2024
- Published by Springer Nature in Research Square
Open AccessOccupational radiation protection for the medical staff during the fluoroscopic spinal procedure: Are we protected adequately?; A cadaveric simulation study
Background Fluoroscopy is crucial in spine surgery, but exposes medical staff to scattered radiation, raising concerns about health risks. The effectiveness of using protective equipment to reduce occupational exposure remains uncertain. Objective The purpose of this study was to evaluate actual radiation exposure doses and shielding effectiveness during simulated spine surgery. Methods Using seven fresh cadavers and mannequins, radiation exposure was measured with and without protective equipment. The X-ray source was positioned under the table, over the table, and laterally. Radiation exposure doses were measured at different simulated areas such as the optic lens, thyroid gland, and hand of the medical staff. Results There were significant differences in the radiation exposure dose under different conditions and for different irradiated areas. The protective equipment significantly reduced radiation exposure. However, exposure remained relatively high, especially to the surgeon's lens and hand when the radiation source was positioned over and laterally. Exposure to scrub nurses and anesthesiologists was relatively low. Conclusions Shielding is critical, but the complete elimination of radiation exposure is challenging. Overall, protective equipment is effective in reducing occupational radiation exposure, but additional measures may be necessary, especially when the radiation source is positioned over the table and laterally. Our results provide a guide for medical staff to understand the risk of radiation exposure.
- Open Access
- 30 November 2023
- Published by Springer Nature in Journal of Occupational Medicine and Toxicology
- Vol. 18 (1) , 1-6
Radiation exposure doses to the surgical team during hip surgery is significantly higher during lateral imaging than posteroanterior imaging: a cadaveric simulation study
Background: Fluoroscopy is indispensable when determining appropriate and effective interventions in orthopedic surgery. On the other hand, there is growing concern about the health hazards of occupational radiation exposure. The aim of this cadaveric simulation study was to measure radiation exposure doses to the surgical team during hip surgery. Methods: We reproduced the intraoperative setting of hip surgery using 7 fresh frozen cadavers (5 male, 2 female) to simulate patients and mannequins to simulate the surgeon, scrub nurse, and anesthesiologist. Six real-time dosimeters were mounted at sites corresponding to the optic lens, thyroid gland, chest, gonads, foot, and hand on each mannequin. The radiation exposure dose to each team member was measured during posteroanterior and lateral fluoroscopic imaging. Results: Radiation exposure doses to the surgeon were significantly higher during 3 min of lateral imaging than during 3 min of posteroanterior imaging at the optic lens (8.1 times higher), thyroid gland (10.3 times), chest (10.8 times), and hand (19.8 times) (p = 0.018, p = 0.018, p = 0.018, and p = 0.018, respectively). During lateral imaging, the radiation doses to the nurse were 0.16, 0.12, 0.09, 0.72, and 0.38 times those to the surgeon at the optic lens, thyroid, chest, gonads, and foot, respectively. The radiation dose to the anesthesiologist was zero at all anatomic sites during posteroanterior imaging and very small during lateral imaging. Conclusions: Radiation exposure dose was significantly higher during lateral imaging up to 19.8 times comparing to the posteroanterior imaging. It is effective to reduce the lateral imaging time for reducing the intraoperative radiation exposure. In addition, appropriate distance from fluoroscopy resulted in very low exposure for nurses and anesthesiologists. Surgeon should pay attention that surgical staff do not get closer than necessary to the irradiation field.
- 30 November 2023
- Published by Springer Nature in Journal of Occupational Medicine and Toxicology
- Vol. 18 (1) , 1-6
Open AccessRadiation exposure doses to the surgical team during hip surgery is significantly higher during lateral imaging than posteroanterior imaging: a cadaveric simulation study
Background: Fluoroscopy is indispensable when determining appropriate and effective interventions in orthopedic surgery. On the other hand, there is growing concern about the health hazards of occupational radiation exposure. The aim of this cadaveric simulation study was to measure radiation exposure doses to the surgical team during hip surgery. Methods: We reproduced the intraoperative setting of hip surgery using 7 fresh frozen cadavers (5 male, 2 female) to simulate patients and mannequins to simulate the surgeon, scrub nurse, and anesthesiologist. Six real-time dosimeters were mounted at sites corresponding to the optic lens, thyroid gland, chest, gonads, foot, and hand on each mannequin. The radiation exposure dose to each team member was measured during posteroanterior and lateral fluoroscopic imaging. Results: Radiation exposure doses to the surgeon were significantly higher during 3 min of lateral imaging than during 3 min of posteroanterior imaging at the optic lens (8.1 times higher), thyroid gland (10.3 times), chest (10.8 times), and hand (19.8 times) (p = 0.018, p = 0.018, p = 0.018, and p = 0.018, respectively). During lateral imaging, the radiation doses to the nurse were 0.16, 0.12, 0.09, 0.72, and 0.38 times those to the surgeon at the optic lens, thyroid, chest, gonads, and foot, respectively. The radiation dose to the anesthesiologist was zero at all anatomic sites during posteroanterior imaging and very small during lateral imaging. Conclusions: Radiation exposure dose was significantly higher during lateral imaging up to 19.8 times comparing to the posteroanterior imaging. It is effective to reduce the lateral imaging time for reducing the intraoperative radiation exposure. In addition, appropriate distance from fluoroscopy resulted in very low exposure for nurses and anesthesiologists. Surgeon should pay attention that surgical staff do not get closer than necessary to the irradiation field.
- Open Access
- 23 March 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-3
Author Correction: Direct measurement of radiation exposure dose to individual organs during diagnostic computed tomography examination
- 23 March 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-3
Open AccessAuthor Correction: Direct measurement of radiation exposure dose to individual organs during diagnostic computed tomography examination
- Open Access
- 8 March 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-10
Direct measurement of radiation exposure dose to individual organs during diagnostic computed tomography examination
Ionizing radiation from Computed tomography (CT) examinations and the associated health risks are growing concerns. The purpose of this study was to directly measure individual organ doses during routine clinical CT scanning protocols and to evaluate how these measurements vary with scanning conditions. Optically stimulated luminescence (OSL) dosimeters were surgically implanted into individual organs of fresh non-embalmed whole-body cadavers. Whole-body, head, chest, and abdomen CT scans were taken of 6 cadavers by simulating common clinical methods. The dosimeters were extracted and the radiation exposure doses for each organ were calculated. Average values were used for analysis. Measured individual organ doses for whole-body routine CT protocol were less than 20 mGy for all organs. The measured doses of surface/shallow organs were higher than those of deep organs under the same irradiation conditions. At the same tube voltage and tube current, all internal organ doses were significantly higher for whole-body scans compared with abdominal scans. This study could provide valuable information on individual organ doses and their trends under various scanning conditions. These data could be referenced and used when considering CT examination in daily clinical situations.
- 8 March 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-10
Open AccessDirect measurement of radiation exposure dose to individual organs during diagnostic computed tomography examination
Ionizing radiation from Computed tomography (CT) examinations and the associated health risks are growing concerns. The purpose of this study was to directly measure individual organ doses during routine clinical CT scanning protocols and to evaluate how these measurements vary with scanning conditions. Optically stimulated luminescence (OSL) dosimeters were surgically implanted into individual organs of fresh non-embalmed whole-body cadavers. Whole-body, head, chest, and abdomen CT scans were taken of 6 cadavers by simulating common clinical methods. The dosimeters were extracted and the radiation exposure doses for each organ were calculated. Average values were used for analysis. Measured individual organ doses for whole-body routine CT protocol were less than 20 mGy for all organs. The measured doses of surface/shallow organs were higher than those of deep organs under the same irradiation conditions. At the same tube voltage and tube current, all internal organ doses were significantly higher for whole-body scans compared with abdominal scans. This study could provide valuable information on individual organ doses and their trends under various scanning conditions. These data could be referenced and used when considering CT examination in daily clinical situations.
- Open Access
- 1 January 2021
- Published by Japan Neurosurgical Society in NMC Case Report Journal
- Vol. 8 (1) , 587-593
Full-endoscopic Spine Surgery for Discogenic Low Back Pain with High-intensity Zones and Modic Type 1 Change in a Professional Baseball Player
Non-specific low back pain in athletes can be caused by discogenic back pain, Modic type 1 change, and facet joint arthritis. In this report, we describe a full-endoscopic surgical strategy that we have used to treat a patient with both discogenic pain and Modic type 1 change. The patient was a 32-year-old professional baseball player who played an infield position and had a 2-year history of low back pain. Three years earlier, he had undergone micro-endoscopic discectomy for left herniated nucleus pulposus at L5/S1. His leg symptoms resolved postoperatively, and he returned to playing baseball the following season. However, his low back pain gradually increased. Two years after the initial surgery, he was experiencing low back pain in daily life and found it very difficult to play baseball. Short T1 inversion recovery (STIR) magnetic resonance imaging (MRI) revealed Modic type 1 change and high-signal intensity zones in degenerated discs at L4/5 and L5/S1. Injection of xylocaine 1% reduced the pain temporarily, confirming that the pain generator was at L4/5 and L5/S1. The pathological diagnosis was discogenic pain with Modic type 1 change. We performed full-endoscopic disc cleaning (FEDC) surgery for the Modic type 1 change and thermal annuloplasty (TA) for the discogenic pain at these levels. The patient’s low back pain decreased steadily thereafter. Six months after surgery, he returned to baseball, playing for a full season without pain. We have successfully treated a professional baseball player with discogenic pain and Modic type 1 change by full-endoscopic surgery.
- 1 January 2021
- Published by Japan Neurosurgical Society in NMC Case Report Journal
- Vol. 8 (1) , 587-593
Open AccessFull-endoscopic Spine Surgery for Discogenic Low Back Pain with High-intensity Zones and Modic Type 1 Change in a Professional Baseball Player
Non-specific low back pain in athletes can be caused by discogenic back pain, Modic type 1 change, and facet joint arthritis. In this report, we describe a full-endoscopic surgical strategy that we have used to treat a patient with both discogenic pain and Modic type 1 change. The patient was a 32-year-old professional baseball player who played an infield position and had a 2-year history of low back pain. Three years earlier, he had undergone micro-endoscopic discectomy for left herniated nucleus pulposus at L5/S1. His leg symptoms resolved postoperatively, and he returned to playing baseball the following season. However, his low back pain gradually increased. Two years after the initial surgery, he was experiencing low back pain in daily life and found it very difficult to play baseball. Short T1 inversion recovery (STIR) magnetic resonance imaging (MRI) revealed Modic type 1 change and high-signal intensity zones in degenerated discs at L4/5 and L5/S1. Injection of xylocaine 1% reduced the pain temporarily, confirming that the pain generator was at L4/5 and L5/S1. The pathological diagnosis was discogenic pain with Modic type 1 change. We performed full-endoscopic disc cleaning (FEDC) surgery for the Modic type 1 change and thermal annuloplasty (TA) for the discogenic pain at these levels. The patient’s low back pain decreased steadily thereafter. Six months after surgery, he returned to baseball, playing for a full season without pain. We have successfully treated a professional baseball player with discogenic pain and Modic type 1 change by full-endoscopic surgery.
- Open Access
- 1 January 2020
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 6 (S1) , S294-S299
Early return to activity after minimally invasive full endoscopic decompression surgery in medical doctors
Full endoscopic surgery including discectomy (FED) and ventral facetectomy (FEVF) is a minimally invasive lumbar decompression surgery that only requires an 8 mm skin incision and can be done under the local anesthesia and sedation. Six male medical doctors underwent the endoscopic decompression (FED/FEVF) for common degenerative lumbar spine problems. Their age ranged from 27 to 63 years of age with a mean of 40 years. Five doctors underwent FED surgery for herniated nucleus pulposus (HNP), and the remaining one physician had FEVF for lumbar lateral recess stenosis. There were no surgery related complications. Postoperatively, 5 out of the 6 physician patients returned the original job within a week because they had clinical duties. The shortest duration to return to work was reported by a 63-year-old orthopedic surgeon resumed working in his clinic 2 days after the FEVF surgery. The longest duration to return to work occurred in general medicine resident who took almost 2 weeks for the sick leave because he did not have clinical duties. The mean duration for the returning to work was 5.8 days after the surgery. At final follow-up ranging from 6 to 30 months, all physician patients were working without any residual pain. In the hands of the authors, the full endoscopic transforaminal decompression surgery is the preferred surgical option and allowed early return to work—an observation that is not the norm in Japan.
- 1 January 2020
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 6 (S1) , S294-S299
Open AccessEarly return to activity after minimally invasive full endoscopic decompression surgery in medical doctors
Full endoscopic surgery including discectomy (FED) and ventral facetectomy (FEVF) is a minimally invasive lumbar decompression surgery that only requires an 8 mm skin incision and can be done under the local anesthesia and sedation. Six male medical doctors underwent the endoscopic decompression (FED/FEVF) for common degenerative lumbar spine problems. Their age ranged from 27 to 63 years of age with a mean of 40 years. Five doctors underwent FED surgery for herniated nucleus pulposus (HNP), and the remaining one physician had FEVF for lumbar lateral recess stenosis. There were no surgery related complications. Postoperatively, 5 out of the 6 physician patients returned the original job within a week because they had clinical duties. The shortest duration to return to work was reported by a 63-year-old orthopedic surgeon resumed working in his clinic 2 days after the FEVF surgery. The longest duration to return to work occurred in general medicine resident who took almost 2 weeks for the sick leave because he did not have clinical duties. The mean duration for the returning to work was 5.8 days after the surgery. At final follow-up ranging from 6 to 30 months, all physician patients were working without any residual pain. In the hands of the authors, the full endoscopic transforaminal decompression surgery is the preferred surgical option and allowed early return to work—an observation that is not the norm in Japan.